872 resultados para Power system stabilizer
Resumo:
The increasing power demand and emerging applications drive the design of electrical power converters into modularization. Despite the wide use of modularized power stage structures, the control schemes that are used are often traditional, in other words, centralized. The flexibility and re-usability of these controllers are typically poor. With a dedicated distributed control scheme, the flexibility and re-usability of the system parts, building blocks, can be increased. Only a few distributed control schemes have been introduced for this purpose, but their breakthrough has not yet taken place. A demand for the further development offlexible control schemes for building-block-based applications clearly exists. The control topology, communication, synchronization, and functionality allocationaspects of building-block-based converters are studied in this doctoral thesis. A distributed control scheme that can be easily adapted to building-block-based power converter designs is developed. The example applications are a parallel and series connection of building blocks. The building block that is used in the implementations of both the applications is a commercial off-the-shelf two-level three-phase frequency converter with a custom-designed controller card. The major challenge with the parallel connection of power stages is the synchronization of the building blocks. The effect of synchronization accuracy on the system performance is studied. The functionality allocation and control scheme design are challenging in the seriesconnected multilevel converters, mainly because of the large number of modules. Various multilevel modulation schemes are analyzed with respect to the implementation, and this information is used to develop a flexible control scheme for modular multilevel inverters.
Resumo:
In recent years, the network vulnerability to natural hazards has been noticed. Moreover, operating on the limits of the network transmission capabilities have resulted in major outages during the past decade. One of the reasons for operating on these limits is that the network has become outdated. Therefore, new technical solutions are studied that could provide more reliable and more energy efficient power distributionand also a better profitability for the network owner. It is the development and price of power electronics that have made the DC distribution an attractive alternative again. In this doctoral thesis, one type of a low-voltage DC distribution system is investigated. Morespecifically, it is studied which current technological solutions, used at the customer-end, could provide better power quality for the customer when compared with the current system. To study the effect of a DC network on the customer-end power quality, a bipolar DC network model is derived. The model can also be used to identify the supply parameters when the V/kW ratio is approximately known. Although the model provides knowledge of the average behavior, it is shown that the instantaneous DC voltage ripple should be limited. The guidelines to choose an appropriate capacitance value for the capacitor located at the input DC terminals of the customer-end are given. Also the structure of the customer-end is considered. A comparison between the most common solutions is made based on their cost, energy efficiency, and reliability. In the comparison, special attention is paid to the passive filtering solutions since the filter is considered a crucial element when the lifetime expenses are determined. It is found out that the filter topology most commonly used today, namely the LC filter, does not provide economical advantage over the hybrid filter structure. Finally, some of the typical control system solutions are introduced and their shortcomings are presented. As a solution to the customer-end voltage regulation problem, an observer-based control scheme is proposed. It is shown how different control system structures affect the performance. The performance meeting the requirements is achieved by using only one output measurement, when operating in a rigid network. Similar performance can be achieved in a weak grid by DC voltage measurement. An additional improvement can be achieved when an adaptive gain scheduling-based control is introduced. As a conclusion, the final power quality is determined by a sum of various factors, and the thesis provides the guidelines for designing the system that improves the power quality experienced by the customer.
Resumo:
The objective of this master's thesis is to compare two different generator systems for wind turbines. It is the doubly fed induction generator system with three stage gearbox and the direct drive permanent magnet generator system. The comparison of generator systems is based on annual energy production for a given wind climate. For comparison a 3 MW, 15 rpm wind turbine is used. Modelling of a turbine rotor, gearbox and converters were done. Design of two generators was done and their performance was examined.
Resumo:
The objective of this dissertation is to improve the dynamic simulation of fluid power circuits. A fluid power circuit is a typical way to implement power transmission in mobile working machines, e.g. cranes, excavators etc. Dynamic simulation is an essential tool in developing controllability and energy-efficient solutions for mobile machines. Efficient dynamic simulation is the basic requirement for the real-time simulation. In the real-time simulation of fluid power circuits there exist numerical problems due to the software and methods used for modelling and integration. A simulation model of a fluid power circuit is typically created using differential and algebraic equations. Efficient numerical methods are required since differential equations must be solved in real time. Unfortunately, simulation software packages offer only a limited selection of numerical solvers. Numerical problems cause noise to the results, which in many cases leads the simulation run to fail. Mathematically the fluid power circuit models are stiff systems of ordinary differential equations. Numerical solution of the stiff systems can be improved by two alternative approaches. The first is to develop numerical solvers suitable for solving stiff systems. The second is to decrease the model stiffness itself by introducing models and algorithms that either decrease the highest eigenvalues or neglect them by introducing steady-state solutions of the stiff parts of the models. The thesis proposes novel methods using the latter approach. The study aims to develop practical methods usable in dynamic simulation of fluid power circuits using explicit fixed-step integration algorithms. In this thesis, twomechanisms whichmake the systemstiff are studied. These are the pressure drop approaching zero in the turbulent orifice model and the volume approaching zero in the equation of pressure build-up. These are the critical areas to which alternative methods for modelling and numerical simulation are proposed. Generally, in hydraulic power transmission systems the orifice flow is clearly in the turbulent area. The flow becomes laminar as the pressure drop over the orifice approaches zero only in rare situations. These are e.g. when a valve is closed, or an actuator is driven against an end stopper, or external force makes actuator to switch its direction during operation. This means that in terms of accuracy, the description of laminar flow is not necessary. But, unfortunately, when a purely turbulent description of the orifice is used, numerical problems occur when the pressure drop comes close to zero since the first derivative of flow with respect to the pressure drop approaches infinity when the pressure drop approaches zero. Furthermore, the second derivative becomes discontinuous, which causes numerical noise and an infinitely small integration step when a variable step integrator is used. A numerically efficient model for the orifice flow is proposed using a cubic spline function to describe the flow in the laminar and transition areas. Parameters for the cubic spline function are selected such that its first derivative is equal to the first derivative of the pure turbulent orifice flow model in the boundary condition. In the dynamic simulation of fluid power circuits, a tradeoff exists between accuracy and calculation speed. This investigation is made for the two-regime flow orifice model. Especially inside of many types of valves, as well as between them, there exist very small volumes. The integration of pressures in small fluid volumes causes numerical problems in fluid power circuit simulation. Particularly in realtime simulation, these numerical problems are a great weakness. The system stiffness approaches infinity as the fluid volume approaches zero. If fixed step explicit algorithms for solving ordinary differential equations (ODE) are used, the system stability would easily be lost when integrating pressures in small volumes. To solve the problem caused by small fluid volumes, a pseudo-dynamic solver is proposed. Instead of integration of the pressure in a small volume, the pressure is solved as a steady-state pressure created in a separate cascade loop by numerical integration. The hydraulic capacitance V/Be of the parts of the circuit whose pressures are solved by the pseudo-dynamic method should be orders of magnitude smaller than that of those partswhose pressures are integrated. The key advantage of this novel method is that the numerical problems caused by the small volumes are completely avoided. Also, the method is freely applicable regardless of the integration routine applied. The superiority of both above-mentioned methods is that they are suited for use together with the semi-empirical modelling method which necessarily does not require any geometrical data of the valves and actuators to be modelled. In this modelling method, most of the needed component information can be taken from the manufacturer’s nominal graphs. This thesis introduces the methods and shows several numerical examples to demonstrate how the proposed methods improve the dynamic simulation of various hydraulic circuits.
Resumo:
Over the recent years, development in mobile working machines has concentrated on reducing emissions owing to the tightening rules and needs to improve energy utilization and reduce power losses. This study focuses on energy utilization and regeneration in an electro-hydraulic forklift, which is a lifting equipment application. The study starts from the modelling and simulation of a hydraulic forklift. The energy regeneration from the potential energy of the load was studied. Also a flow-based electric motor speed control was suggested in this thesis instead of the throttle control method or the variable displacement pump control. Topics related to further development in the future are discussed. Finally, a summary and conclusions are presented.
Resumo:
Diplomityön tarkoituksena oli tutkia vaatimusten hallintaa suunnittelu- ja konsultointiyrityksen kannalta Suomen ydinvoimaprojekteissa keskittyen ydinturvallisuus- ja laatuvaatimuksiin. Ydinvoimaprojekteissa toimiminen on edellyttänyt menettelyohjeiden ja laatujärjestelmän uudelleen organisointia yrityksessä ja esiin on noussut haasteita liittyen muun muassa vaatimusten tunnistamiseen ja todentamiseen erityyppisissä ja erilaajuisissa projekteissa. Työ toteutettiin perehtymällä ydinvoimaan liittyvään lainsäädäntöön Suomessa, ohjeisiin ja standardeihin sekä haastattelemalla yrityksen omia asiantuntijoita. Viimeaikaisista sekä meneillään olevista projekteista kerättiin kokemuksia sekä arvioitiin ydinvoima projekteja varten laaditun projektin toteutusohjeen toimivuutta ja käytettävyyttä esimerkkiprojektin avulla. Suurimmiksi haasteiksi tunnistettiin lainsäädännöllisten vaatimusten, kuten ydinvoima- laitosohjeiden (YVL) muuttuminen ja tulkinnanvaraisuus sekä asiakkaiden perehtymät- tömyys Suomen lainsäädäntöön ja vaatimustasoon liittyen ydinturvallisuuteen. Työn tuloksena tunnistettiin hyviä vaatimusten hallintaan liittyviä projektinhallintaa ja ydin- turvallisuutta edistäviä asioita, kuten vaatimusten täsmentäminen jo sopimustasolla sekä niiden täyttymisen seuranta projektin aikana. Erillisen vaatimustietokannan luomista ydinvoimaprojekteja varten tutkittiin, mutta siitä luovuttiin teknisten vaatimusten osalta kannattamattomana, sillä standardien ja vaatimusten määrä kasvoi niin suureksi, että niiden hallitseminen vaatisi enemmän työtä kuin mitä projektien taso yleensä sallisi.
Resumo:
The purpose of this work was evaluating the energetic demand of a seeder-fertilizer machine as a function of the type and handling of vegetal covering culture and of the fertilizer deposition shank depth. A Valtra BM100 tractor was used implemented to pull a high precision seeder-fertilizer machine with four ranks of seeding, spaced 0.9 m for maize culture. Experiment was conducted with design in randomized blocks in factorial plots, in the Laboratory of Machines and Agricultural Mechanization experimental area (LAMMA) of UNESP-Jaboticabal, using two covering cultures (black-mucuna and crotalaria), three handlings of this covering, two mechanical (straw crusher and roller knife) and one chemical (pulverization of herbicide), performed 120 days after seeding of covering cultures and three depths of fertilizer deposition shank, completing 18 treatments, with four repetitions, totaling 72 observations. Parameters of displacement speed, gliding, force on traction bar, peak force, power on pulling bar and fuel consumption were evaluated. It was possible to conclude that force on traction bar was less for depths of 0.11 and 0.14 m of fertilizer plough shank, the same occurring for peak force, power on traction bar and volumetric consumption. The specific consumption was lower at a depth of 0.17 m of fertilizer plough shank. Covering cultures and their handlings did not interfere in the performance of machines under inquiry.
Resumo:
This work is a study of the implementation of a classical controller using a tuning method referred to as IMC (Internal Model Control) and aimed at the reduction of electrical energy consumption by the appropriate relation between energy consumption and the cooling time with forced air. The supervisory system installed was able to manipulate the variable of frequency of the signal power of the exhaust fan engine (forced air module), to accelerate or decelerate the loss of heat from the product to be cooled by airflow variation that passes through the mass of the produce. The results demonstrated a reduction in energy consumption from 64% and an increase of only 8% in the cooling time to the system using PI/IMC (Proportional - Integral with IMC) tuning method compared with the system in its operating nominal condition. This PI/IMC control may be implemented directly in a frequency converter, without the need to purchase a computer or PLC (programmable logic controller) to run the dedicated application, increasing its economical viability.
Resumo:
The process of cold storage chambers contributes largely to the quality and longevity of stored products. In recent years, it has been intensified the study of control strategies in order to decrease the temperature change inside the storage chamber and to reduce the electric power consumption. This study has developed a system for data acquisition and process control, in LabVIEW language, to be applied in the cooling system of a refrigerating chamber of 30m³. The use of instrumentation and the application developed fostered the development of scientific experiments, which aimed to study the dynamic behavior of the refrigeration system, compare the performance of control strategies and the heat engine, even due to the controlled temperature, or to the electricity consumption. This system tested the strategies for on-off control, PID and fuzzy. Regarding power consumption, the fuzzy controller showed the best result, saving 10% when compared with other tested strategies.
Resumo:
The rural electrification is characterized by geographical dispersion of the population, low consumption, high investment by consumers and high cost. Moreover, solar radiation constitutes an inexhaustible source of energy and in its conversion into electricity photovoltaic panels are used. In this study, equations were adjusted to field conditions presented by the manufacturer for current and power of small photovoltaic systems. The mathematical analysis was performed on the photovoltaic rural system I-100 from ISOFOTON, with power 300 Wp, located at the Experimental Farm Lageado of FCA/UNESP. For the development of such equations, the circuitry of photovoltaic cells has been studied to apply iterative numerical methods for the determination of electrical parameters and possible errors in the appropriate equations in the literature to reality. Therefore, a simulation of a photovoltaic panel was proposed through mathematical equations that were adjusted according to the data of local radiation. The results have presented equations that provide real answers to the user and may assist in the design of these systems, once calculated that the maximum power limit ensures a supply of energy generated. This real sizing helps establishing the possible applications of solar energy to the rural producer and informing the real possibilities of generating electricity from the sun.
Resumo:
The use of no tillage system associated with the crop-livestock integration is an alternate managing that promotes the accumulation of dry matter in the soil, an essential fact to make the system sustainable and profitable. The aim of this study was to evaluate the operational performance of a planter-tractor set on maize straws intercropped with Urochloa, in different seeding modes. The soybean crop was seed on the intercropping of two forage species (Urochloa brizantha and Urochloa ruziziensis) in five cropping systems: MBL (Maize with Urochloa in the maize seeding row, mixed with base fertilizer and deposited at 0.10 m), MBE (Maize with Urochloa seeded between rows at the same day of seeding maize), MBC (Urochloa between rows of maize seeded with the covering fertilizer at the V4 stage), MBLA (Maize with Urochloa by broadcast seeding at the V4 stage ) and MS (Single Maize: control). The following variables were evaluated: dry mass of maize straw, dry mass of forages and total dry mass of straw; and for the operational parameters the speed of seeding, wheel slippage, traction force and average power at the drawbar. The results showed that the amount of straw produced by maize intercropping with Urochloa, interferes in the operational performance of the tractor-planter at the operation of soybean seeding, i.e., areas with higher amount of straw promote greater energy demand, as well as higher wheel slippage.
Resumo:
The furrow openers for no-till system should be easy to penetrate the soil, generate low levels of soil mobilization and require a little traction force. Thus, the aim of this research was to compare six hoe-type furrow openers, four of industrial manufacturing and two handcrafted models, which were used in planters in the region of Pelotas, Brazil. The parameters for comparison among these furrow openers were the horizontal (Fh) and vertical (Fv) forces acting on the tip of the hoe and the cross-sectional area mobilized in the furrow. The experimental design was randomized, with six treatments (furrow openers) from T1 to T6, with four repetitions, constituted by their passage through plots of 20 x 3 m. The force data were collected by load cells and a signal conditioner. The determination of the mobilized area in the furrow was done by a micro soil profilometer. It was concluded that the furrow openers T1, T4 and T6 presented the lowest values of horizontal force (statistically equal and ranging between 1,034 and 1,230 N) and that T1 and T2 produced the highest vertical forces downwards (statistically identical and varying between 749 and 845 N). The furrow openers T1, T2, T4, T5 and T6 generated soil mobilization statistically equal and between 0.006993 and 0.008933 m².
Resumo:
Object-oriented programming is a widely adopted paradigm for desktop software development. This paradigm partitions software into separate entities, objects, which consist of data and related procedures used to modify and inspect it. The paradigm has evolved during the last few decades to emphasize decoupling between object implementations, via means such as explicit interface inheritance and event-based implicit invocation. Inter-process communication (IPC) technologies allow applications to interact with each other. This enables making software distributed across multiple processes, resulting in a modular architecture with benefits in resource sharing, robustness, code reuse and security. The support for object-oriented programming concepts varies between IPC systems. This thesis is focused on the D-Bus system, which has recently gained a lot of users, but is still scantily researched. D-Bus has support for asynchronous remote procedure calls with return values and a content-based publish/subscribe event delivery mechanism. In this thesis, several patterns for method invocation in D-Bus and similar systems are compared. The patterns that simulate synchronous local calls are shown to be dangerous. Later, we present a state-caching proxy construct, which avoids the complexity of properly asynchronous calls for object inspection. The proxy and certain supplementary constructs are presented conceptually as generic object-oriented design patterns. The e ect of these patterns on non-functional qualities of software, such as complexity, performance and power consumption, is reasoned about based on the properties of the D-Bus system. The use of the patterns reduces complexity, but maintains the other qualities at a good level. Finally, we present currently existing means of specifying D-Bus object interfaces for the purposes of code and documentation generation. The interface description language used by the Telepathy modular IM/VoIP framework is found to be an useful extension of the basic D-Bus introspection format.
Resumo:
Reliable detection of intrapartum fetal acidosis is crucial for preventing morbidity. Hypoxia-related changes of fetal heart rate variability (FHRV) are controlled by the autonomic nervous system. Subtle changes in FHRV that cannot be identified by inspection can be detected and quantified by power spectral analysis. Sympathetic activity relates to low-frequency FHRV and parasympathetic activity to both low- and high-frequency FHRV. The aim was to study whether intra partum fetal acidosis can be detected by analyzing spectral powers of FHRV, and whether spectral powers associate with hypoxia-induced changes in the fetal electrocardiogram and with the pH of fetal blood samples taken intrapartum. The FHRV of 817 R-R interval recordings, collected as a part of European multicenter studies, were analyzed. Acidosis was defined as cord pH ≤ 7.05 or scalp pH ≤ 7.20, and metabolic acidosis as cord pH ≤ 7.05 and base deficit ≥ 12 mmol/l. Intrapartum hypoxia increased the spectral powers of FHRV. As fetal acidosis deepened, FHRV decreased: fetuses with significant birth acidosis had, after an initial increase, a drop in spectral powers near delivery, suggesting a breakdown of fetal compensation. Furthermore, a change in excess of 30% of the low-to-high frequency ratio of FHRV was associated with fetal metabolic acidosis. The results suggest that a decrease in the spectral powers of FHRV signals concern for fetal wellbeing. A single measure alone cannot be used to reveal fetal hypoxia since the spectral powers vary widely intra-individually. With technical developments, continuous assessment of intra-individual changes in spectral powers of FHRV might aid in the detection of fetal compromise due to hypoxia.