943 resultados para Postwar Reconstruction
Resumo:
The aim of this study was to validate the accuracy and reproducibility of a statistical shape model-based 2D/3D reconstruction method for determining cup orientation after total hip arthroplasty. With a statistical shape model, this method allows reconstructing a patient-specific 3D-model of the pelvis from a standard AP X-ray radiograph. Cup orientation (inclination and anteversion) is then calculated with respect to the anterior pelvic plane that is derived from the reconstructed model.
Resumo:
Cranioplasty is a common neurosurgical procedure. Free-hand molding of polymethyl methacrylate (PMMA) cement into complex three-dimensional shapes is often time-consuming and may result in disappointing cosmetic outcomes. Computer-assisted patient-specific implants address these disadvantages but are associated with long production times and high costs. In this study, we evaluated the clinical, radiological, and cosmetic outcomes of a time-saving and inexpensive intraoperative method to mold custom-made implants for immediate single-stage or delayed cranioplasty. Data were collected from patients in whom cranioplasty became necessary after removal of bone flaps affected by intracranial infection, tumor invasion, or trauma. A PMMA replica was cast between a negative form of the patient's own bone flap and the original bone flap with exactly the same shape, thickness, and dimensions. Clinical and radiological follow-up was performed 2 months post-surgery. Patient satisfaction (Odom criteria) and cosmesis (visual analogue scale for cosmesis) were evaluated 1 to 3 years after cranioplasty. Twenty-seven patients underwent intraoperative template-molded patient-specific cranioplasty with PMMA. The indications for cranioplasty included bone flap infection (56%, n = 15), calvarian tumor resection (37%, n = 10), and defect after trauma (7%, n = 2). The mean duration of the molding procedure was 19 ± 7 min. Excellent radiological implant alignment was achieved in 94% of the cases. All (n = 23) but one patient rated the cosmetic outcome (mean 1.4 years after cranioplasty) as excellent (70%, n = 16) or good (26%, n = 6). Intraoperative cast-molded reconstructive cranioplasty is a feasible, accurate, fast, and cost-efficient technique that results in excellent cosmetic outcomes, even with large and complex skull defects.
Resumo:
The classical DIEP-flap is considered state-of-the-art in microsurgical autologous breast reconstruction. Some patients may require additional volume to match the contralateral breast. This quality control study prospectively evaluates the feasibility and outcome of a surgical technique, which pursues the volumetric augmentation of the DIEP-flap by harvesting of additional subscarpal fat tissue cranial to the classical flap border.
Resumo:
A main field in biomedical optics research is diffuse optical tomography, where intensity variations of the transmitted light traversing through tissue are detected. Mathematical models and reconstruction algorithms based on finite element methods and Monte Carlo simulations describe the light transport inside the tissue and determine differences in absorption and scattering coefficients. Precise knowledge of the sample's surface shape and orientation is required to provide boundary conditions for these techniques. We propose an integrated method based on structured light three-dimensional (3-D) scanning that provides detailed surface information of the object, which is usable for volume mesh creation and allows the normalization of the intensity dispersion between surface and camera. The experimental setup is complemented by polarization difference imaging to avoid overlaying byproducts caused by inter-reflections and multiple scattering in semitransparent tissue.
Resumo:
Producing a rich, personalized Web-based consultation tool for plastic surgeons and patients is challenging.
Resumo:
This report describes the authors' currently favored method of nipple reconstruction in cases of a pre-existing scar on the breast mound that passes through the intended site of nipple reconstruction.
Resumo:
To reconstruct a forehead defect, a plastic surgeon must be knowledgeable about the neural, vascular, and muscular anatomy. The position of fixed structures such as eyebrows and hairline should be respected. For the past 5 years, we have used double hatchet flaps for reconstruction of relatively large supra-eyebrow and forehead defects. Because this flap does not appear to be among the techniques used by young plastic surgeons, we thought that it would be valuable to report our experience.
Resumo:
OBJECTIVE To assess trends in the frequency of concomitant vascular reconstructions (VRs) from 2000 through 2009 among patients who underwent pancreatectomy, as well as to compare the short-term outcomes between patients who underwent pancreatic resection with and without VR. DESIGN Single-center series have been conducted to evaluate the short-term and long-term outcomes of VR during pancreatic resection. However, its effectiveness from a population-based perspective is still unknown. Unadjusted, multivariable, and propensity score-adjusted generalized linear models were performed. SETTING Nationwide Inpatient Sample from 2000 through 2009. PATIENTS A total of 10 206 patients were involved. MAIN OUTCOME MEASURES Incidence of VR during pancreatic resection, perioperative in-hospital complications, and length of hospital stay. RESULTS Overall, 10 206 patients were included in this analysis. Of these, 412 patients (4.0%) underwent VR, with the rate increasing from 0.7% in 2000 to 6.0% in 2009 (P < .001). Patients who underwent pancreatic resection with VR were at a higher risk for intraoperative (propensity score-adjusted odds ratio, 1.94; P = .001) and postoperative (propensity score-adjusted odds ratio, 1.36; P = .008) complications, while the mortality and median length of hospital stay were similar to those of patients without VR. Among the 25% of hospitals with the highest surgical volume, patients who underwent pancreatic surgery with VR had significantly higher rates of postoperative complications and mortality than patients without VR. CONCLUSIONS The frequency of VR during pancreatic surgery is increasing in the United States. In contrast with most single-center analyses, this population-based study demonstrated that patients who underwent VR during pancreatic surgery had higher rates of adverse postoperative outcomes than their counterparts who underwent pancreatic resection only. Prospective studies incorporating long-term outcomes are warranted to further define which patients benefit from VR.