770 resultados para Polymer Optical Fibers
Resumo:
AIMS Patients with ST-segment elevation myocardial infarction (STEMI) feature thrombus-rich lesions with large necrotic core, which are usually associated with delayed arterial healing and impaired stent-related outcomes. The use of bioresorbable vascular scaffolds (Absorb) has the potential to overcome these limitations owing to restoration of native vessel lumen and physiology at long term. The purpose of this randomized trial was to compare the arterial healing response at short term, as a surrogate for safety and efficacy, between the Absorb and the metallic everolimus-eluting stent (EES) in patients with STEMI. METHODS AND RESULTS ABSORB-STEMI TROFI II was a multicentre, single-blind, non-inferiority, randomized controlled trial. Patients with STEMI who underwent primary percutaneous coronary intervention were randomly allocated 1:1 to treatment with the Absorb or EES. The primary endpoint was the 6-month optical frequency domain imaging healing score (HS) based on the presence of uncovered and/or malapposed stent struts and intraluminal filling defects. Main secondary endpoint included the device-oriented composite endpoint (DOCE) according to the Academic Research Consortium definition. Between 06 January 2014 and 21 September 2014, 191 patients (Absorb [n = 95] or EES [n = 96]; mean age 58.6 years old; 17.8% females) were enrolled at eight centres. At 6 months, HS was lower in the Absorb arm when compared with EES arm [1.74 (2.39) vs. 2.80 (4.44); difference (90% CI) -1.06 (-1.96, -0.16); Pnon-inferiority <0.001]. Device-oriented composite endpoint was also comparably low between groups (1.1% Absorb vs. 0% EES). One case of definite subacute stent thrombosis occurred in the Absorb arm (1.1% vs. 0% EES; P = ns). CONCLUSION Stenting of culprit lesions with Absorb in the setting of STEMI resulted in a nearly complete arterial healing which was comparable with that of metallic EES at 6 months. These findings provide the basis for further exploration in clinically oriented outcome trials.
Resumo:
AIMS The Absorb bioresorbable vascular scaffold (Absorb BVS) provides similar clinical outcomes compared with a durable polymer-based everolimus-eluting metallic stent (EES) in stable coronary artery disease patients. ST-elevation myocardial infarction (STEMI) lesions have been associated with delayed arterial healing and impaired stent-related outcomes. The purpose of the present study is to compare directly the arterial healing response, angiographic efficacy and clinical outcomes between the Absorb BVS and metallic EES. METHODS AND RESULTS A total of 191 patients with acute STEMI were randomly allocated to treatment with the Absorb BVS or a metallic EES 1:1. The primary endpoint is the neointimal healing (NIH) score, which is calculated based on a score taking into consideration the presence of uncovered and malapposed stent struts, intraluminal filling defects and excessive neointimal proliferation, as detected by optical frequency domain imaging (OFDI) six months after the index procedure. The study will provide 90% power to show non-inferiority of the Absorb BVS compared with the EES. CONCLUSIONS This will be the first randomised study investigating the arterial healing response following implantation of the Absorb BVS compared with the EES. The healing response assessed by a novel NIH score in conjunction with results on angiographic efficacy parameters and device-oriented events will elucidate disease-specific applications of bioresorbable scaffolds.
Resumo:
OBJECTIVES The aim of this study was to compare the efficacy of amphilimus-eluting stents (AES) with that of everolimus-eluting stents (EES) in patients with diabetes mellitus (DM). BACKGROUND The AES is a polymer-free drug-eluting stent that elutes sirolimus formulated with an amphiphilic carrier from laser-dug wells. This technology could be associated with a high efficacy in patients with DM. METHODS This was a multicenter, randomized, noninferiority trial. Patients with DM medically treated with oral glucose-lowering agents or insulin and de novo coronary lesions were randomized in a 1:1 fashion to AES or EES. The primary endpoint was the neointimal (NI) volume obstruction assessed by optical coherence tomography at 9-month follow-up. RESULTS A total of 116 lesions in 112 patients were randomized. Overall, 40% were insulin-treated patients, with a median HbA1c of 7.3% (interquartile range: 6.7% to 8.0%). The primary endpoint, NI volume obstruction, was 11.97 ± 5.94% for AES versus 16.11 ± 18.18% for EES, meeting the noninferiority criteria (p = 0.0003). Pre-specified subgroup analyses showed a significant interaction between stent type and glycemic control (p = 0.02), with a significant reduction in NI hyperplasia in the AES group in patients with the higher HbA1c (p = 0.03). By quantitative coronary angiography, in-stent late loss was 0.14 ± 0.24 for AES versus 0.24 ± 0.57 mm for EES (p = 0.27), with a larger minimal lumen diameter at follow-up for AES (p = 0.02), mainly driven by 2 cases of occlusive restenosis in the EES group. CONCLUSIONS AES are noninferior to EES for the coronary revascularization of patients with DM. These results suggest a high efficacy of the AES and may support the potential benefit of this stent in patients with DM. (A Randomized Comparison of Reservoir-Based Polymer-Free Amphilimus-Eluting Stents Versus Everolimus-Eluting Stents With Durable Polymer in Patients With Diabetes Mellitus [RESERVOIR]; NCT01710748).
Resumo:
This project assessed the effectiveness of polymer gel dosimeters as tools for measuring the dose deposited by and LET of a proton beam. A total of three BANG® dosimeter formulations were evaluated: BANG®-3-Pro-2 BANGkits™ for dose measurement and two BANG®-3 variants, the LET-Baseline and LET-Meter dosimeters, for LET measurement. All dosimeters were read out using an OCT scanner. The basic characteristics of the BANGkits™ were assessed in a series of photon and electron irradiations. The dose-response relationship was found to be sigmoidal with a threshold for response of approximately 15 cGy. The active region of the dosimeter, the volume in which dosimeter response is not inhibited by oxygen, was found to make up roughly one fourth of the total dosimeter volume. Delivering a dose across multiple fractions was found to yield a greater response than delivering the same dose in a single irradiation. The dosimeter was found to accurately measure a dose distribution produced by overlapping photon fields, yielding gamma pass rates of 95.4% and 93.1% from two planar gamma analyses. Proton irradiations were performed for measurements of proton dose and LET. Initial irradiations performed through the side of a dosimeter led to OCT artifacts. Gamma pass rates of 85.7% and 89.9% were observed in two planar gamma analyses. In irradiations performed through the base of a dosimeter, gel response was found to increase with height in the dosimeter, even in areas of constant dose. After a correction was applied, gamma pass rates of 94.6% and 99.3% were observed in two planar gamma analyses. Absolute dose measurements were substantially higher (33%-100%) than the delivered doses for proton irradiations. Issues encountered while calibrating the LET-Meter gel restricted analysis of the LET measurement data to the SOBP of a proton beam. LET-Meter overresponse was found to increase linearly with track-average LET across the LET range that could be investigated (1.5 keV/micron – 3.5 keV/micron).
Resumo:
Incorporation of fiber in cereals may lead to quality issues, thus decreasing consumer acceptance. This is partially due to deterioration of the microstructure, one of the primary quality attributes of cereals. The objective of this study was to better understand the mechanisms by which dietary fibers affect the quality of cereal products during extrusioncooking. The study quantified the effect of amount and type of fiber and whole grain on (i) texture, (ii) structure, and (iii) rehydration properties of extruded cereals. New innovative methods were applied and combined with traditional techniques to characterize both the structure and the rehydration properties. Extruded cereals were produced using a starch-based recipe (whole and wheat flours) and two sources of fibers (oat bran concentrate and wheat bran). The oat and wheat bran levels used in this study were 0, 10, and 20%. The different mixtures were extruded in a pilot twinscrew extruder BC21 (Clextral) and then sugar coated after drying. Mechanical properties of extruded cereals were investigated by compression test. The cellular structure was observed by X-ray tomography. The quality of coating (thickness, homogeneity) was analyzed by optical coherence tomography. The rehydration properties of such cereals in milk were evaluated by magnetic resonance imaging and optical coherence tomography. This work revealed that structure assessment of extruded cereals may lead to a better understanding of the effect of fiber addition on texture and rehydration properties. The application of innovative methods, such as optical coherence tomography and magnetic resonance imaging, was found to be useful to quantify the structural properties.