936 resultados para Parametric sensitivity analysis


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Concrete solar collectors offer a type of solar collector with structural, aesthetic and economic advantages over current populartechnologies. This study examines the influential parameters of concrete solar collectors. In addition to the external conditions,the performance of a concrete solar collector is influenced by the thermal properties of the concrete matrix, piping network andfluid. Geometric and fluid flow parameters also influence the performance of the concrete solar collector. A literature review ofconcrete solar collectors is conducted in order to define the benchmark parameters from which individual parameters are thencompared. The numerical model consists of a 1D pipe flow network coupled with the heat transfer in a 3D concrete domain. Thispaper is concerned with the physical parameters that define the concrete solar collector, thus a constant surface temperature isused as the exposed surface boundary condition with all other surfaces being insulated. Results show that, of the parametersinvestigated, the pipe spacing, ps, concrete conductivity, kc, and the pipe embedment depth, demb, are among those parameterswhich have greatest effect on the collector’s performance. The optimum balance between these parameters is presented withrespect to the thermal performance and discussed with reference to practical development issues.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We explore the recently developed snapshot-based dynamic mode decomposition (DMD) technique, a matrix-free Arnoldi type method, to predict 3D linear global flow instabilities. We apply the DMD technique to flows confined in an L-shaped cavity and compare the resulting modes to their counterparts issued from classic, matrix forming, linear instability analysis (i.e. BiGlobal approach) and direct numerical simulations. Results show that the DMD technique, which uses snapshots generated by a 3D non-linear incompressible discontinuous Galerkin Navier?Stokes solver, provides very similar results to classical linear instability analysis techniques. In addition, we compare DMD results issued from non-linear and linearised Navier?Stokes solvers, showing that linearisation is not necessary (i.e. base flow not required) to obtain linear modes, as long as the analysis is restricted to the exponential growth regime, that is, flow regime governed by the linearised Navier?Stokes equations, and showing the potential of this type of analysis based on snapshots to general purpose CFD codes, without need of modifications. Finally, this work shows that the DMD technique can provide three-dimensional direct and adjoint modes through snapshots provided by the linearised and adjoint linearised Navier?Stokes equations advanced in time. Subsequently, these modes are used to provide structural sensitivity maps and sensitivity to base flow modification information for 3D flows and complex geometries, at an affordable computational cost. The information provided by the sensitivity study is used to modify the L-shaped geometry and control the most unstable 3D mode.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, the experimental results of an unconventional joined-wing aircraft configuration are presented. The test model uses two different wings, forward and rear, both joined in tandem and forming diamond shapes both in plant and front views. The wings are joined in such a way that it is possible to change the rear wing dihedral angle values and the rear wing sweep angle values in 25 different positions that modify the relative distance and the relative height between the wings. To measure the system aerodynamic coefficients itis necessary to perform wind tunnel tests. The datapresented corresponds to the lift, drag and induced drag aerodynamic coefficients, as well as the aerodynamic efficiency and the parameter for minimum required power, from the calculated values of the lift and drag time series measured by a 6-axis force and torque sensor. The results show the influence on the aerodynamic coefficients of the rear wing sweep and dihedral angles parameters. As a main result, it can be concluded that, in general terms, the lift and induced drag aerodynamic coefficients values decrease as both the distance and height between the wings increase, on the other hand, the total drag aerodynamic coefficient decreases if the distance between the wings increases, but nevertheless shows a slight tendency to increase if the height of the rear wing increases, whereas the aerodynamic efficiency and the parameter for minimum required power increase if the distance between the wings increases

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Interest rate sensitivity assessment framework based on fixed income yield indexes is developed and applied to two types of emerging market corporate debt: investment grade and high yield exposures. Our research advances beyond the correlation analyses focused on co- movements in yields and/or spreads of risky and risk-free assets. We show that correlation- based analyses of interest rate sensitivity could appear rather inconclusive and, hence, we investigate the bottom line profit and loss of a hypothetical model portfolio of corporates. We consider historical data covering the period 2002 – 2015, which enable us to assess interest rate sensitivity of assets during the development, the apogee, and the aftermath of the global financial crisis. Based on empirical evidence, both for investment and speculative grades securities, we find that the emerging market corporates exhibit two different regimes of sensitivity to interest rate changes. We observe switching from a positive sensitivity under the normal market conditions to a negative one during distressed phases of business cycles. This research sheds light on how financial institutions may approach interest rate risk management, evidencing that even plain vanilla portfolios of emerging market corporates, which on average could appear rather insensitive to the interest rate risk in fact present a binary behavior of their interest rate sensitivities. Our findings allow banks and financial institutions for optimizing economic capital under Basel III regulatory capital rules.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A rapid and efficient Dispersive Liquid–Liquid Microextraction (DLLME) followed by Laser-Induced Breakdown Spectroscopy detection (LIBS) was evaluated for simultaneous determination of Cr, Cu, Mn, Ni and Zn in water samples. Metals in the samples were extracted with tetrachloromethane as pyrrolidinedithiocarbamate (APDC) complexes, using vortex agitation to achieve dispersion of the extractant solvent. Several DLLME experimental factors affecting extraction efficiency were optimized with a multivariate approach. Under optimum DLLME conditions, DLLME-LIBS method was found to be of about 4.0–5.5 times more sensitive than LIBS, achieving limits of detection of about 3.7–5.6 times lower. To assess accuracy of the proposed DLLME-LIBS procedure, a certified reference material of estuarine water was analyzed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study presents a computational parametric analysis of DME steam reforming in a large scale Circulating Fluidized Bed (CFB) reactor. The Computational Fluid Dynamic (CFD) model used, which is based on Eulerian-Eulerian dispersed flow, has been developed and validated in Part I of this study [1]. The effect of the reactor inlet configuration, gas residence time, inlet temperature and steam to DME ratio on the overall reactor performance and products have all been investigated. The results have shown that the use of double sided solid feeding system remarkable improvement in the flow uniformity, but with limited effect on the reactions and products. The temperature has been found to play a dominant role in increasing the DME conversion and the hydrogen yield. According to the parametric analysis, it is recommended to run the CFB reactor at around 300 °C inlet temperature, 5.5 steam to DME molar ratio, 4 s gas residence time and 37,104 ml gcat -1 h-1 space velocity. At these conditions, the DME conversion and hydrogen molar concentration in the product gas were both found to be around 80%.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Historic vaulted masonry structures often need strengthening interventions that can effectively improve their structural performance, especially during seismic events, and at the same time respect the existing setting and the modern conservation requirements. In this context, the use of innovative materials such as fiber-reinforced composite materials has been shown as an effective solution that can satisfy both aspects. This work aims to provide insight into the computational modeling of a full-scale masonry vault strengthened by fiber-reinforced composite materials and analyze the influence of the arrangement of the reinforcement on the efficiency of the intervention. At first, a parametric model of a cross vault focusing on a realistic representation of its micro-geometry is proposed. Then numerical modeling, simulating the pushover analyses, of several barrel vaults reinforced with different reinforcement configurations is performed. Finally, the results are collected and discussed in terms of force-displacement curves obtained for each proposed configuration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The efficacy of the human papillomavirus type 16 (HPV-16)/HPV-18 AS04-adjuvanted vaccine against cervical infections with HPV in the Papilloma Trial against Cancer in Young Adults (PATRICIA) was evaluated using a combination of the broad-spectrum L1-based SPF10 PCR-DNA enzyme immunoassay (DEIA)/line probe assay (LiPA25) system with type-specific PCRs for HPV-16 and -18. Broad-spectrum PCR assays may underestimate the presence of HPV genotypes present at relatively low concentrations in multiple infections, due to competition between genotypes. Therefore, samples were retrospectively reanalyzed using a testing algorithm incorporating the SPF10 PCR-DEIA/LiPA25 plus a novel E6-based multiplex type-specific PCR and reverse hybridization assay (MPTS12 RHA), which permits detection of a panel of nine oncogenic HPV genotypes (types 16, 18, 31, 33, 35, 45, 52, 58, and 59). For the vaccine against HPV types 16 and 18, there was no major impact on estimates of vaccine efficacy (VE) for incident or 6-month or 12-month persistent infections when the MPTS12 RHA was included in the testing algorithm versus estimates with the protocol-specified algorithm. However, the alternative testing algorithm showed greater sensitivity than the protocol-specified algorithm for detection of some nonvaccine oncogenic HPV types. More cases were gained in the control group than in the vaccine group, leading to higher point estimates of VE for 6-month and 12-month persistent infections for the nonvaccine oncogenic types included in the MPTS12 RHA assay (types 31, 33, 35, 45, 52, 58, and 59). This post hoc analysis indicates that the per-protocol testing algorithm used in PATRICIA underestimated the VE against some nonvaccine oncogenic HPV types and that the choice of the HPV DNA testing methodology is important for the evaluation of VE in clinical trials. (This study has been registered at ClinicalTrials.gov under registration no. NCT00122681.).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Chemical cross-linking has emerged as a powerful approach for the structural characterization of proteins and protein complexes. However, the correct identification of covalently linked (cross-linked or XL) peptides analyzed by tandem mass spectrometry is still an open challenge. Here we present SIM-XL, a software tool that can analyze data generated through commonly used cross-linkers (e.g., BS3/DSS). Our software introduces a new paradigm for search-space reduction, which ultimately accounts for its increase in speed and sensitivity. Moreover, our search engine is the first to capitalize on reporter ions for selecting tandem mass spectra derived from cross-linked peptides. It also makes available a 2D interaction map and a spectrum-annotation tool unmatched by any of its kind. We show SIM-XL to be more sensitive and faster than a competing tool when analyzing a data set obtained from the human HSP90. The software is freely available for academic use at http://patternlabforproteomics.org/sim-xl. A video demonstrating the tool is available at http://patternlabforproteomics.org/sim-xl/video. SIM-XL is the first tool to support XL data in the mzIdentML format; all data are thus available from the ProteomeXchange consortium (identifier PXD001677).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to compare different treatments for dentin hypersensitivity in a 6-month follow-up. One hundred and one teeth exhibiting non carious cervical lesions were selected. The assessment method used to quantify sensitivity was the cold air syringe, recorded by the visual analogue scale (VAS), prior to treatment (baseline), immediately after topical treatment, after 1 week, 1, 3 and 6 months. Teeth were randomly assigned to five groups (n = 20): G1: Gluma Desensitizer (GD); G2: Seal&Protect (SP); G3: Oxa-gel (OG); G4: Fluoride (F); G5: Low intensity laser-LILT (660 nm/3.8 J/cm²/15 mW). Analysis was based on the non-parametric Kruskal-Wallis test that demonstrated statistical differences immediately after the treatment (p = 0.0165). To observe the individual effects of each treatment, data was submitted to Friedman test. It was observed that GD and SP showed immediate effect after application. Reduction in the pain level throughout the six-month follow-up was also observed. In contrast, LILT presented a gradual reduction of hypersensitivity. OG and F showed effects as of the first and third month respectively. It can be concluded that, after the 6-month clinical evaluation, all therapies showed lower VAS sensitivity values compared with baseline, independently of their different modes of action.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We measured the effects of epilepsy on visual contrast sensitivity to linear and vertical sine-wave gratings. Sixteen female adults, aged 21 to 50 years, comprised the sample in this study, including eight adults with generalized tonic-clonic seizure-type epilepsy and eight age-matched controls without epilepsy. Contrast threshold was measured using a temporal two-alternative forced-choice binocular psychophysical method at a distance of 150 cm from the stimuli, with a mean luminance of 40.1 cd/m². A one-way analysis of variance (ANOVA) applied to the linear contrast threshold showed significant differences between groups (F[3,188] = 14.829; p < .05). Adults with epilepsy had higher contrast thresholds (1.45, 1.04, and 1.18 times for frequencies of 0.25, 2.0, and 8.0 cycles per degree of visual angle, respectively). The Tukey Honestly Significant Difference post hoc test showed significant differences (p < .05) for all of the tested spatial frequencies. The largest difference between groups was in the lowest spatial frequency. Therefore, epilepsy may cause more damage to the neural pathways that process low spatial frequencies. However, epilepsy probably alters both the magnocellular visual pathway, which processes low spatial frequencies, and the parvocellular visual pathway, which processes high spatial frequencies. The experimental group had lower visual contrast sensitivity to all tested spatial frequencies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Small angle X-ray scattering (SAXS) images of normal breast tissue and benign and malignant breast tumour tissues, fixed in formalin, were measured at the momentum transfer range of 0.063 nm(-1) <= q (=4 pi sin(theta/2)/lambda) <= 2.720 nm(-1). Four intrinsic parameters were extracted from the scattering profiles (1D SAXS image reduced) and, from the combination of these parameters, another three parameters were also created. All parameters, intrinsic and derived, were subject to discriminant analysis, and it was verified that parameters such as the area of diffuse scatter at the momentum transfer range 0.50 <= q <= 0.56 nm(-1), the ratio between areas of fifth-order axial and third-order lateral peaks and third-order axial spacing provide the most significant information for diagnosis (p < 0.001). Thus, in this work it was verified that by combining these three parameters it was possible to classify human breast tissues as normal, benign lesion or malignant lesion with a sensitivity of 83% and a specificity of 100%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The aim of this work was to verify the differentiation between normal and pathological human carotid artery tissues by using fluorescence and reflectance spectroscopy in the 400- to 700-nm range and the spectral characterization by means of principal components analysis. Background Data: Atherosclerosis is the most common and serious pathology of the cardiovascular system. Principal components represent the main spectral characteristics that occur within the spectral data and could be used for tissue classification. Materials and Methods: Sixty postmortem carotid artery fragments (26 non-atherosclerotic and 34 atherosclerotic with non-calcified plaques) were studied. The excitation radiation consisted of a 488-nm argon laser. Two 600-mu m core optical fibers were used, one for excitation and one to collect the fluorescence radiation from the samples. The reflectance system was composed of a halogen lamp coupled to an excitation fiber positioned in one of the ports of an integrating sphere that delivered 5 mW to the sample. The photo-reflectance signal was coupled to a 1/4-m spectrograph via an optical fiber. Euclidean distance was then used to classify each principal component score into one of two classes, normal and atherosclerotic tissue, for both fluorescence and reflectance. Results: The principal components analysis allowed classification of the samples with 81% sensitivity and 88% specificity for fluorescence, and 81% sensitivity and 91% specificity for reflectance. Conclusions: Our results showed that principal components analysis could be applied to differentiate between normal and atherosclerotic tissue with high sensitivity and specificity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To evaluate the intratumoral reliability of color Doppler parameters and the contribution of Doppler sonography to the gray-scale differential diagnosis of ovarian masses. Methods: An observational study was performed including 67 patients, 15 (22.4%) with malignant ovarian neoplasm and 52 (77.6%) with benign ovarian diseases. We performed the Doppler evaluation in two distinct vessels selected after decreasing the Doppler gain to sample only vessels with higher velocity flow. Doppler measurements were obtained from each identified vessel, and resistive index (RI), pulsatility index (PI), peak systolic velocity (PSV), and end-diastolic velocity (EDV) were measured. Intraclass coefficient of correlation (ICC), sensitivity, specificity, and potential improvement in gray-scale ultrasound performance were calculated. Results: The general ICC were 0.60 (95% CI 0.42- 0.73) for RI, 0.65 (95% CI 0.49- 0.77) for PI, 0.07 (95% CI- 0.17-0.30) for PSV, and 0.19 (95% CI -0.05-0.41) for EDV. The sensitivity and specificity were respectively 84.6% and 86.7% for RI, 69.2% and 93.3% for PI, 80.0% and 65.4% for gray-scale sonography, and 93.3% and 65.4% for gray-scale plus RI (p = 0.013). Conclusions: Gynecologists must be careful in interpreting results from Doppler evaluation of ovarian masses because PSV and EDV present poor intratumoral reliability. The lower RI value, evaluated in at least two distinct sites of the tumor, was able to improve the performance of gray-scale ultrasound in differential diagnosis of ovarian masses.