896 resultados para PROGRESSIVE EXTERNAL OPHTHALMOPLEGIA
Resumo:
This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.
Resumo:
The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.
Resumo:
The aim of this study was to evaluate the putative influence of diabetes without metabolic control in the loss of tooth structure as well as histological changes in dentin and pulp tissue in rats. Diabetes was induced in Wistar rats (n=25) by intravenous administration of alloxan (42mg/kg). Diabetic and non-diabetic control rats were evaluated at 1, 3, 6, 9 and 12 months of follow-up. In order to evaluate the presence and progression of dental caries and periapical lesions, hemimandibles were removed and submitted to radiographical, histological, and morphometrical procedures. Dental caries were detected after radiographical and histological evaluations in diabetic group from the third month of diabetes onset, increasing gradually in frequency and severity in periods. Diabetic rats dental pulps also presented significant reduction in volume density of collagen fibers and fibroblasts at third month, parallel with a trend towards the increase in inflammatory cells volume density. Diabetic rats presented a generalized pulp tissue necrosis after 6 months of diabetes induction. Moreover, periapical lesions were not detected in control group, while these lesions were observed in all rats after 3, 6, 9, and 12 months of diabetes induction. Uncontrolled diabetes seems to trigger the loss of tooth structure, associated to histological dental changes and mediates its evolution to progressive severe pulp and periapical lesions in rats. Therefore, diabetes may be considered a very important risk factor regarding alterations in dental pulp, development of dental caries, and periapical lesions.
Resumo:
This systematic review aimed to evaluate if the internal connection is more efficient than the external connection and its associated influencing factors. A specific question was formulated according to the Population, Intervention, Control, and Outcome (PICO): Is internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? An electronic search of the MEDLINE and the Web of Knowledge databases was performed for relevant studies published in English up to November 2013 by two independent reviewers. The keywords used in the search included a combination of dental implant and internal connection or Morse connection or external connection. Selected studies were randomized clinical trials, prospective or retrospective studies, and in vitro studies with a clear aim of investigating the internal and/or external implant connection use. From an initial screening yield of 674 articles, 64 potentially relevant articles were selected after an evaluation of their titles and abstracts. Full texts of these articles were obtained with 29 articles fulfilling the inclusion criteria. Morse taper connection has the best sealing ability. Concerning crestal bone loss, internal connections presented better results than external connections. The limitation of the present study was the absence of randomized clinical trials that investigated if the internal connection was more efficient than the external connection. The external and internal connections have different mechanical, biological, and esthetical characteristics. Besides all systems that show proper success rates and effectiveness, crestal bone level maintenance is more important around internal connections than external connections. The Morse taper connection seems to be more efficient concerning biological aspects, allowing lower bacterial leakage and bone loss in single implants, including aesthetic regions. Additionally, this connection type can be successfully indicated for fixed partial prostheses and overdenture planning, since it exhibits high mechanical stability.
Resumo:
Adolescents are seeking new references and experiences, which may involve attitudes of risk and exposure to accidents and violence from external causes. These events constitute a serious Public Health problem. The scope of this study was to analyze the occurrence of accidents by external causes in adolescents from 10 to 19 years of age attended at sentinel urgency and emergency services in Brazil. Data from the 2009 Surveillance System for Violence and Accidents (VIVA 2009) was analyzed in 74 emergency units in 23 state capitals and the Federal District. The findings revealed that 6,434 adolescents (89.8%) were victims of accidents and 730 (10.2 %) were victims of violence. The main causes of the accidents were falls and traffic accidents, and assaults were predominant in violence. For both accidents and violence, non-white male adolescents were predominant and the events occurred most frequently on the public highways. A marked increase was detected, with hospitalization of victims of violence between 15 and 19 years of age. Understanding the epidemiological reality of external causes among adolescents represents an important tool for health prevention and promotion policies and the culture of peace seeking to reduce morbidity and mortality.
Resumo:
This article estimates the impact of mortality from external causes on the human development index (HDI) along the Brazilian borderland from 2000 to 2005. Data obtained from Brazilian government agencies were combined using the methodology defined by the United Nations Development Program, revealing the HDI according to actual conditions. Subsequently, deaths from external causes were excluded in order to estimate their impact on the index, recalculating life expectancy using the technique of competing causes. HDI showed a gradual increase from North to South, with the most developed regions concentrated in the South, consistent with studies using other sets of economic indicators. By excluding mortality from external causes, the highest gains appeared in regions where the HDI (under actual conditions) were lower, and the magnitude of gains declined towards the South.
Resumo:
We find the first nonlinear correction to the field produced by a static charge at rest in a background constant magnetic field. It is quadratic in the charge and purely magnetic. The third-rank polarization tensor-the nonlinear response function-is written within the local approximation of the effective action in an otherwise model-and approximation-independent way within any P-invariant nonlinear electrodynamics, QED included. DOI: 10.1103/PhysRevD.86.125028
Resumo:
The immatures of Polybia paulista Ihering were described using light and scanning electron microscopy and the results are compared with previous descriptions within the same or related wasps. This study is based on 2 whole nests collected in the municipality of Rio Claro, Sao Paulo, in Brazil. We have detected the existence of 5 larval instars. The main morphological alterations over development occur in the relative size of structures, yet certain structures appear with subsequent instars and become more evident later in development: increasing density in the number of body spines and papillae; the appearance of body setae in fifth-instar larvae; opening of spiracles upon second-instar larvae; 2 body shapes in fifth-instar larvae; the appearance of a lateral tooth on the mandibles of fourth instar; presence of spines on the maxillae of fifth-instar larvae; altered shape of galea and palps upon third-instar larvae from a cluster of sensilla to a conical elevation; and the appearance of spines on postmentum upon fourth-instar larvae. This way, the present study presents a detailed description of the immatures of P. paulista, and we hope the presented information can be useful to morphological, taxonomic, and phylogenetic studies.
Resumo:
Twelve participants ran (9 km . h(-1)) to test two types of running shoes: replica and original shoes. Ground reaction force, plantar pressure and electromyographic activity were recorded. The shoes were tested randomly and on different days. Comparisons between the two experimental conditions were made by analysis of variance (ANOVA) test (P <= 0.05). The time to first peak, loading rate of the first peak and impulse of the first 75 ms of stance were significantly different between the shoes (P <= 0.05), revealing an increase of impact forces for the replica shoes. The peak plantar pressure values were significantly higher (P <= 0.05) when wearing replica shoes. During running, the contact area was significantly smaller (P <= 0.05) for the replica shoe. The electromyographic activity of the analysed muscles did not show changes between the two shoes in running. These findings suggest that the use of replica running shoes can increase the external load applied to the human body, but may not change the muscle activity pattern during locomotion. This new mechanical situation may increase the risk of injuries in these movements.
Resumo:
Tamoxifen, a selective estrogen receptor modulator, has antifibrotic properties; however, whether it can attenuate renal fibrosis is unknown. In this study, we tested the effects of tamoxifen in a model of hypertensive nephrosclerosis (chronic inhibition of nitric oxide synthesis with L-NAME). After 30 days, treated rats had significantly lower levels of albuminuria as well as lower histologic scores for glomerulosclerosis and interstitial fibrosis than untreated controls. Tamoxifen was renoprotective despite having no effect on the sustained, severe hypertension induced by L-NAME. Tamoxifen prevented the accumulation of extracellular matrix by decreasing the expression of collagen I, collagen III, and fibronectin mRNA and protein. These renoprotective effects associated with inhibition of TGF-beta 1 and plasminogen activator inhibitor-1, and with a significant reduction in a-smooth muscle actin-positive cells in the renal interstitium. Furthermore, tamoxifen abrogated IL-1 beta- and angiotensin-II-induced proliferation of fibroblasts from both kidney explants and from the NRK-49F cell line. Tamoxifen also inhibited the expression of extracellular matrix components and the production and release of TGF-beta 1 into the supernatant of these cells. In summary, tamoxifen exhibits antifibrotic effects in the L-NAME model of hypertensive nephrosclerosis, likely through the inhibition of TGF-beta 1, suggesting that it may have therapeutic use in CKD treatment.
Resumo:
Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns. Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05). Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05). Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50)
Resumo:
Background: Early progressive nonfluent aphasia (PNFA) may be difficult to differentiate from semantic dementia (SD) in a nonspecialist setting. There are descriptions of the clinical and neuropsychological profiles of patients with PNFA and SD but few systematic comparisons. Method: We compared the performance of groups with SD (n = 27) and PNFA (n = 16) with comparable ages, education, disease duration, and severity of dementia as measured by the Clinical Dementia Rating Scale on a comprehensive neuropsychological battery. Principal components analysis and intergroup comparisons were used. Results: A 5-factor solution accounted for 78.4% of the total variance with good separation of neuropsychological variables. As expected, both groups were anomic with preserved visuospatial function and mental speed. Patients with SD had lower scores on comprehension-based semantic tests and better performance on verbal working memory and phonological processing tasks. The opposite pattern was found in the PNFA group. Conclusions: Neuropsychological tests that examine verbal and nonverbal semantic associations, verbal working memory, and phonological processing are the most helpful for distinguishing between PNFA and SD.
Resumo:
This paper is intended as a proposition of a new concept in the field of chronobiology, External Temporal Organization, a notion complementary to that of the Internal Temporal Organization. We will try to explain the possibility that a set of external elements, that occur in a particular order, can act together as a single synchronizing element of the circadian system. We will see that this is not a zeitgeber, in the classic sense, but a much more complex factor, consisting of several elements that appear in the real environment at different times ( phases), constituting as a whole a powerful temporal frame, closer to the way the stimuli occur in the natural environment, in which the entrainment does not take place just in a specific time of the day.
Resumo:
Introduction: Vitamin D is responsible for the regulation of certain genes at the transcription level, via interaction with the vitamin D receptor, and influences host immune responses and aspects of bone development, growth, and homeostasis. Our aim was to investigate the association of TaqI vitamin D receptor gene polymorphism with external apical root resorption during orthodontic treatment. Methods: Our subjects were 377 patients with Class II Division 1 malocclusion, divided into 3 groups: (1) 160 with external apical root resorption <= 1.43 mm, (2) 179 with external apical root resorption >1.43 mm), and (3) 38 untreated subjects. External apical root resorption of the maxillary incisors was evaluated on periapical radiographs taken before and after 6 months of treatment. After DNA collection and purification, vitamin D receptor TaqI polymorphism analysis was performed by polymerase chain reaction-restriction fragment length polymorphism. Univariate and multivariate analyses were performed to verify the association of clinical and genetic variables with external apical root resorption (P <0.05). Results: There was a higher proportion of external apical root resorption in orthodontically treated patients compared with the untreated subjects. In patients orthodontically treated, age higher than 14 years old, initial size of the maxillary incisor root superior to 30 mm, and premolar extraction were associated with increased external apical root resorption. Genotypes containing the C allele were weakly associated with protection against external apical root resorption (CC + CT x TT [odds ratio, 0.29; 95% confidence interval, 0.07-1.23; P = 0.091]) when treated orthodontic patients were compared to untreated individuals. Conclusions: Clinical factors and vitamin D receptor TaqI polymorphism were associated with external apical root resorption in orthodontic patients. (Am J Orthod Dentofacial Orthop 2012; 142: 339-47)
Resumo:
One drawback of in vitro cell culturing is the dedifferentiation process that cells experience. Smooth muscle cells (SMC) also change molecularly and morphologically with long term culture. The main objective of this study was to evaluate if culture passages interfere in vascular SMC mechanical behavior. SMC were obtained from five different porcine arterial beds. Optical magnetic twisting cytometry (OMTC) was used to characterize mechanically vascular SMC from different cultures in distinct passages and confocal microscopy/western blotting, to evaluate cytoskeleton and extracellular matrix proteins. We found that vascular SMC rigidity or viscoelastic complex modulus (G) decreases with progression of passages. A statistically significant negative correlation between G and passage was found in four of our five cultures studied. Phalloidin-stained SMC from higher passages exhibited lower mean signal intensity per cell (confocal microscopy) and quantitative western blotting analysis showed a decrease in collagen I content throughout passages. We concluded that vascular SMC progressively lose their stiffness with serial culture passaging. Thus, limiting the number of passages is essential for any experiment measuring viscoelastic properties of SMC in culture.