946 resultados para PERCUTANEOUS-ABSORPTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Renewable energy is growing in demand, and thus the the manufacture of solar cells and photovoltaic arrays has advanced dramatically in recent years. This is proved by the fact that the photovoltaic production has doubled every 2 years, increasing by an average of 48% each year since 2002. Covering the general overview of solar cell working, and its model, this thesis will start with the three generations of photovoltaic solar cell technology, and move to the motivation of dedicating research to nanostructured solar cell. For the current generation solar cells, among several factors, like photon capture, photon reflection, carrier generation by photons, carrier transport and collection, the efficiency also depends on the absorption of photons. The absorption coefficient,α, and its dependence on the wavelength, λ, is of major concern to improve the efficiency. Nano-silicon structures (quantum wells and quantum dots) have a unique advantage compared to bulk and thin film crystalline silicon that multiple direct and indirect band gaps can be realized by appropriate size control of the quantum wells. This enables multiple wavelength photons of the solar spectrum to be absorbed efficiently. There is limited research on the calculation of absorption coefficient in nano structures of silicon. We present a theoretical approach to calculate the absorption coefficient using quantum mechanical calculations on the interaction of photons with the electrons of the valence band. One model is that the oscillator strength of the direct optical transitions is enhanced by the quantumconfinement effect in Si nanocrystallites. These kinds of quantum wells can be realized in practice in porous silicon. The absorption coefficient shows a peak of 64638.2 cm-1 at = 343 nm at photon energy of ξ = 3.49 eV ( = 355.532 nm). I have shown that a large value of absorption coefficient α comparable to that of bulk silicon is possible in silicon QDs because of carrier confinement. Our results have shown that we can enhance the absorption coefficient by an order of 10, and at the same time a nearly constant absorption coefficient curve over the visible spectrum. The validity of plots is verified by the correlation with experimental photoluminescence plots. A very generic comparison for the efficiency of p-i-n junction solar cell is given for a cell incorporating QDs and sans QDs. The design and fabrication technique is discussed in brief. I have shown that by using QDs in the intrinsic region of a cell, we can improve the efficiency by a factor of 1.865 times. Thus for a solar cell of efficiency of 26% for first generation solar cell, we can improve the efficiency to nearly 48.5% on using QDs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The demands in production and associate costs at power generation through non renewable resources are increasing at an alarming rate. Solar energy is one of the renewable resource that has the potential to minimize this increase. Utilization of solar energy have been concentrated mainly on heating application. The use of solar energy in cooling systems in building would benefit greatly achieving the goal of non-renewable energy minimization. The approaches of solar energy heating system research done by initiation such as University of Wisconsin at Madison and building heat flow model research conducted by Oklahoma State University can be used to develop and optimize solar cooling building system. The research uses two approaches to develop a Graphical User Interface (GUI) software for an integrated solar absorption cooling building model, which is capable of simulating and optimizing the absorption cooling system using solar energy as the main energy source to drive the cycle. The software was then put through a number of litmus test to verify its integrity. The litmus test was conducted on various building cooling system data sets of similar applications around the world. The output obtained from the software developed were identical with established experimental results from the data sets used. Software developed by other research are catered for advanced users. The software developed by this research is not only reliable in its code integrity but also through its integrated approach which is catered for new entry users. Hence, this dissertation aims to correctly model a complete building with the absorption cooling system in appropriate climate as a cost effective alternative to conventional vapor compression system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traditional methods of measuring sound absorption coefficient and sound transmission loss of a material are time consuming. To overcome this limitation, normal incidence sound absorption and transmission loss measurement technique was developed. Unfortunately the equipment required for this task is equally expensive. Hence efforts are taken to develop a cost-effective equipment for measuring normal incidence sound absorption coefficient and transmission loss. An impedance tube capable of measure absorption coefficient and transmission loss is designed and built under a budget of $1500 for educational institutes. A background study is performed to gain knowledge and understanding of the normal incidence measurements technique. Based on the literature review, parameters involved such as tube material, source and microphone properties, sample holders, etc. are discussed in depth. Based on these parameters, design options are generated to meet the cost and functionality targets pre-assigned. After selection of materials and components, an impedance tube is built and tested using three fibrous absorption materials for absorption and a barrier for transmission loss performance. These measured results then compared with those obtained with the help of industry recognized Brüel & Kjær impedance tube. The results show performances are comparable, hence validation the new built tube.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is practically only one method of gas analysis. This was worked out many years ago by Bunsen, Hempel, and Winkler and consists in the successive absorption with different chemicals of the various constituents of the gas. The only improvement to this method is the oxidation and combustion of different components of a mixture followed by absorption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The major goal of acute ischemic stroke treatment is fast and sufficient recanalization. Percutaneous transluminal balloon angioplasty (PTA) and/or placement of a stent might achieve both by compressing the thrombus at the occlusion site. This study assesses the feasibility, recanalization rate, and complications of the 2 techniques in an animal model. MATERIALS AND METHODS: Thirty cranial vessels of 7 swine were occluded by injection of radiopaque thrombi. Fifteen vessel occlusions were treated by PTA alone and 15, by placement of a stent and postdilation. Recanalization was documented immediately after treatment and after 1, 2, and 3 hours. Thromboembolic events and dissections were documented. RESULTS: PTA was significantly faster to perform (mean, 16.6 minutes versus 33.0 minutes for stent placement; P < .001), but the mean recanalization rate after 1 hour was significantly better after stent placement compared with PTA alone (67.5% versus 14.6%, P < .001). Due to the self-expanding force of the stent, vessel diameter further increased with time, whereas the recanalization result after PTA was prone to reocclusion. Besides thromboembolic events related to the passing maneuvers at the occlusion site, no thrombus fragmentation and embolization occurred during balloon inflation or stent deployment. Flow to side branches could also be restored at the occlusion site because it was possible to direct thrombus compression. CONCLUSIONS: Stent placement and postdilation proved to be much more efficient in terms of acute and short-term vessel recanalization compared with PTA alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our purpose was to perform a systematic review and meta-analysis of randomized trials comparing percutaneous coronary intervention (PCI) of the infarct-related artery (IRA) with medical therapy in patients randomized >12 h after acute myocardial infarction (AMI).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Powder metallurgy, the most recent innovation in met­allurgical process, is not a new art; although not until recently did it become a matter of general interest, this being due not only to the products formed but also to the possibilities of future developments. The manufacture and application of metal powders is now beginning to take a position as a recognized part of the science of metallurgy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: No-reflow after a primary percutaneous coronary intervention (PCI) is associated with a high incidence of left ventricular (LV) failure and a poor prognosis. Endothelin-1 (ET-1) is a potent endothelium-derived vasoconstrictor peptide and an important modulator of neutrophil function. Elevated systemic ET-1 levels have recently been reported to predict a poor prognosis in patients with acute myocardial infarction (AMI) treated by primary PCI. We aimed to investigate the relationship between systemic ET-1 plasma levels and no-reflow in a group of AMI patients treated by primary PCI. METHODS AND RESULTS: A group of 51 patients (age 59+/-9.9 years, 44 males) with a first AMI, undergoing successful primary or rescue PCI, were included in the study. Angiographic no-reflow was defined as coronary TIMI flow grade < or =2 or TIMI flow 3 with a final myocardial blush grade < or =2. Blood samples were obtained from all patients on admission for ET-1 levels measurement. No reflow was observed in 31 patients (61%). Variables associated with no-reflow at univariate analysis included culprit lesion of the left anterior coronary descending artery (LAD) (67 vs. 29%, P=0.006) and ET-1 plasma levels (3.95+/-0.7 vs. 3.3+/-0.8 pg/mL, P=0.004). At multivariable logistic regression analysis, ET-1 was the only significant predictor of no-reflow (P=0.03) together with LAD as the culprit vessel (P=0.04). CONCLUSION: ET-1 plasma levels predict angiographic no-reflow after successful primary or rescue PCI. These findings suggest that ET-1 antagonists might be beneficial in the management of no-reflow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The objective of this study was to assess predictors of residual shunts after percutaneous patent foramen ovale (PFO) closure with Amplatzer PFO occluder (AGA Medical Corporation, Golden Valley, MN, USA). METHODS: All percutaneous PFO closures, using Amplatzer PFO occluder performed at a tertiary center between May 2002 and August 2006, were reviewed. Follow-up, including saline contrast transesophageal echocardiography, was performed in all patients 6 months after the intervention. PATIENTS: A total of 135 procedures were performed. Mean age of the patients was 51 years. The indication for PFO closure was an ischemic cerebrovascular event in 92%, paradoxical systemic embolism in 4%, and a diving accident in 4%. Recurrent events prior to PFO closure were noted in 34%. A concomitant atrial septal aneurysm was present in 61%. RESULTS: At 6 months follow-up, a residual shunt was detected in 26 patients (19%). Residual shunts were more common in patients with an atrial septal aneurysm (27 vs. 8%, P= .01) and in patients treated with a 35-mm compared with a 25-mm device (39 vs. 15%, P= .01). A concomitant atrial septal aneurysm remained independently associated with residual shunts when controlled for body mass index, gender, age, atrial dimensions, and presence of a Chiari network (odds ratio 4.1, 95% confidence intervals 1.1-15.0). CONCLUSION: The presence of atrial septal aneurysms in patients undergoing percutaneous PFO closure with an Amplatzer PFO occluder significantly increases the rate of residual shunts at 6 months follow-up, even if 35-mm devices are used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We sought to assess the safety and clinical efficacy of patent foramen ovale (PFO) closure under fluoroscopic guidance only, without intraprocedural echocardiography. BACKGROUND: Percutaneous PFO closure has been shown to be safe and feasible using several devices. It is generally performed using simultaneously fluoroscopic and transesophageal or intracardiac echocardiographic guidance. Transesophageal echocardiography requires sedation or general anesthesia and intubation to avoid aspiration. Intracardiac echocardiography is costly and has inherent risks. Both lengthen the procedure. The Amplatzer PFO Occluder (AGA Medical Corporation, Golden Valley, Minnesota) can be safely implanted without echocardiographic guidance. METHODS: A total of 620 patients (51 +/- 12 years; 66% male) underwent PFO closure using the Amplatzer PFO Occluder for secondary prevention of presumed paradoxical embolism. Based on size and mobility of the PFO and the interatrial septum, an 18-mm device was used in 50 patients, a 25-mm device in 492, and a 35-mm device in 78. RESULTS: All procedures were successful, with 5 procedural complications (0.8%): 4 arteriovenous fistulae requiring elective surgical correction, and 1 transient ischemic attack. Contrast transesophageal echocardiography at 6 months showed complete closure in 91% of patients, whereas a minimal, moderate, or large residual shunt persisted in 6%, 2%, and 1%, respectively. During a mean follow-up period of 3.0 +/- 1.9 years (median: 2.6 years; total patient-years: 1,871), 5 ischemic strokes, 8 transient ischemic attacks, and no peripheral emboli were reported. Freedom from recurrent ischemic stroke, transient ischemic attack, or peripheral embolism was 99% at 1 year, 99% at 2 years, and 97% at 5 years. CONCLUSIONS: The Amplatzer PFO Occluder affords excellent safety and long-term clinical efficacy of percutaneous PFO closure without intraprocedural echocardiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 83-year-old woman underwent percutaneous closure of postinfarction ventricular septal defect following anteroseptal myocardial infarction and percutaneous coronary intervention with stent implantation of the left anterior descending coronary artery. Postinfarction percutaneous ventricular septal defect closure was initially complicated by an iatrogenic left ventricular free-wall perforation. Both defects were closed using two Amplatzer muscular VSD occluders during the same session.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The association between aortic valve disease and coronary atherosclerosis is common. In the recent era of percutaneous aortic valve replacement (PAVR), there is little experience with coronary artery intervention after valve implantation. CASE REPORT: To our knowledge, this is the first case of successful percutaneous coronary intervention after implantation of a CoreValve percutaneous aortic valve. We report a case of a 79-year-old female patient who underwent successful coronary artery intervention few months after a CoreValve's percutaneous implantation for severe aortic valve stenosis. Verifying the position of the used wires (crossing from inside the self expanding frame) is of utmost importance before proceeding to coronary intervention. In this case, crossing the aortic valve, coronary angiography, and multivessel stenting were successfully performed. CONCLUSION: Percutaneous coronary intervention in patients with previous CoreValve is feasible and safe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Patients with refractory angina pectoris in end-stage coronary artery disease represent a severe condition with a higher reduction of life-expectancy and quality of life as compared to patients with stable coronary artery disease. It was the purpose of this study to invasively re-evaluate highly symptomatic patients with formerly diagnosed refractory angina pectoris in end-stage coronary artery disease for feasible options of myocardial revascularization. METHODS: Thirty-four patients formerly characterized as having end stage coronary artery disease with refractory angina pectoris were retrospectively followed for coronary interventions. RESULTS: Of those 34 patients 21 (61.8%) were eventually revascularized with percutaneous interventional revascularization (PCI). Due to complex coronary morphology (angulation, chronic total occlusion) PCI demanded an above-average amount of time (66 +/- 42 minutes, range 25-206 minutes) and materials (contrast media 247 +/- 209 ml, range 50-750 ml; PCI guiding wires 2.0 +/- 1.4, range 1-6 wires). Of PCI patients 7 (33.3%) showed a new lesion as a sign of progression of atherosclerosis. Clinical success rate with a reduction to angina class II or lower was 71.4% at 30 days. Surgery was performed in a total of8 (23.5%) patients with a clinical success rate of 62.5%. Based on an intention-to-treat 2 patients of originally 8 (25%) demonstrated clinical success. Mortality during follow-up (1-18 months) was 4.8% in patients who underwent PCI, 25% in patients treated surgically and 25% in those only treated medically. CONCLUSION: The majority of patients with end-stage coronary artery disease can be treated effectively with conventional invasive treatment modalities. Therefore even though it is challenging and demanding PCI should be considered as a first choice before experimental interventions are considered.