990 resultados para PAIN MEASUREMENT
Resumo:
Purpose: To examine the possible role of H+-activated acid-sensing ion channels (ASICs) in pain perception we characterized their expression in bladder dome biopsies of Bladder Pain Syndrome (BPS) patients and controls, in cultured human urothelium and in urothelial TEU-2 cells.Materials and Methods: Cold cut biopsies from the bladder dome were obtained in 8 asymptomatic controls and 28 patients with symptoms of BPS. ASIC expression was analyzed by QPCR and immunofluorescence. The channel function was measured by electrophysiology.Results: ASIC1a, ASIC2a and ASIC3 mRNAs were detected in human bladder. Similar amounts of ASIC1a and -3 were detected in detrusor smooth muscle, whereas in urothelium ASIC3 levels were higher than -1a. ASIC2a mRNA levels were lower than either -1a or -3 in both layers. ASIC currents were measured in TEU-2 cells and in primary cultures of human urothelium, and ASIC expression was confirmed by QPCR. Differentiation of TEU-2 cells caused an up-regulation of ASIC2a and ASIC3, and a down-regulation of ASIC1a mRNAs. BPS patients showed an up-regulation of ASIC2a and -3 mRNA, whereas ASIC1a remained unchanged. In contrast, the mRNA levels of TRPV1 were down-regulated during BPS. All differences were statistically significant (p<0.05)Conclusions: Several different ASIC subunits are expressed in human bladder and TEU-2 cells, where their levels are regulated during urothelial differentiation. An up-regulation of ASIC2a and -3 in BPS suggests their involvement in increased pain and hyperalgesia. A down-regulation of TRPV1 mRNA levels might indicate a different regulatory mechanism, controlling its expression in human bladder.
Resumo:
BACKGROUND: Microvascular decompression (MVD) is the reference technique for pharmacoresistant trigeminal neuralgia (TN). OBJECTIVE: To establish whether the safety and efficacy of Gamma Knife surgery for recurrent TN are influenced by prior MVD. METHODS: Between July 1992 and November 2010, 54 of 737 patients (45 of 497 with >1 year of follow-up) had a history of MVD (approximately half also with previous ablative procedure) and were operated on with Gamma Knife surgery for TN in the Timone University Hospital. A single 4-mm isocenter was positioned in the cisternal portion of the trigeminal nerve at a median distance of 7.6 mm (range, 3.9-11.9 mm) anterior to the emergence of the nerve. A median maximum dose of 85 Gy (range, 70-90 Gy) was delivered. RESULTS: The median follow-up time was 39.5 months (range, 14.1-144.6 months). Thirty-five patients (77.8%) were initially pain free in a median time of 14 days (range, 0-180 days), much lower compared with our global population of classic TN (P = .01). Their actuarial probabilities of remaining pain-free without medication at 3, 5, 7, and 10 years were 66.5%, 59.1%, 59.1%, and 44.3%. The hypoesthesia actuarial rate at 1 year was 9.1% and remained stable until 12 years (median, 8 months). CONCLUSION: Patients with previous MVD showed a significantly lower probability of initial pain cessation compared with our global population with classic TN (P = .01). The toxicity was low (only 9.1% hypoesthesia); furthermore, no patient reported bothersome hypoesthesia. However, the probability of maintaining pain relief without medication was 44.3% at 10 years, similar to our global series of classic TN (P = .85). ABBREVIATIONS: BNI, Barrow Neurological InstituteCI, confidence intervalCTN, classic trigeminal neuralgiaGKS, Gamma Knife surgeryHR, hazard ratioMVD, microvascular decompressionTN, trigeminal neuralgia.
Measurement of cell microrheology by magnetic twisting cytometry with frequency domain demodulation.
Resumo:
This paper presents a new respiratory impedance estimator to minimize the error due to breathing. Its practical reliability was evaluated in a simulation using realistic signals. These signals were generated by superposing pressure and flow records obtained in two conditions: 1) when applying forced oscillation to a resistance- inertance- elastance (RIE) mechanical model; 2) when healthy subjects breathed through the unexcited forced oscillation generator. Impedances computed (4-32 Hz) from the simulated signals with the new estimator resulted in a mean value which was scarcely biased by the added breathing (errors less than 1 percent in the mean R, I , and E ) and had a small variability (coefficients of variation of R, I, and E of 1.3, 3.5, and 9.6 percent, respectively). Our results suggest that the proposed estimator reduces the error in measurement of respiratory impedance without appreciable extracomputational cost.
Resumo:
Background: The NDI, COM and NPQ are evaluation instruments for disability due to NP. There was no Spanish version of NDI or COM for which psychometric characteristics were known. The objectives of this study were to translate and culturally adapt the Spanish version of the Neck Disability Index Questionnaire (NDI), and the Core Outcome Measure (COM), to validate its use in Spanish speaking patients with non-specific neck pain (NP), and to compare their psychometric characteristics with those of the Spanish version of the Northwick Pain Questionnaire (NPQ).Methods: Translation/re-translation of the English versions of the NDI and the COM was done blindly and independently by a multidisciplinary team. The study was done in 9 primary care Centers and 12 specialty services from 9 regions in Spain, with 221 acute, subacute and chronic patients who visited their physician for NP: 54 in the pilot phase and 167 in the validation phase. Neck pain (VAS), referred pain (VAS), disability (NDI, COM and NPQ), catastrophizing (CSQ) and quality of life (SF-12) were measured on their first visit and 14 days later. Patients' self-assessment was used as the external criterion for pain and disability. In the pilot phase, patients' understanding of each item in the NDI and COM was assessed, and on day 1 test-retest reliability was estimated by giving a second NDI and COM in which the name of the questionnaires and the order of the items had been changed.Results: Comprehensibility of NDI and COM were good. Minutes needed to fill out the questionnaires [median, (P25, P75)]: NDI. 4 (2.2, 10.0), COM: 2.1 (1.0, 4.9). Reliability: [ICC, (95%CI)]: NDI: 0.88 (0.80, 0.93). COM: 0.85 (0.75,0.91). Sensitivity to change: Effect size for patients having worsened, not changed and improved between days 1 and 15, according to the external criterion for disability: NDI: -0.24, 0.15, 0.66; NPQ: -0.14, 0.06, 0.67; COM: 0.05, 0.19, 0.92. Validity: Results of NDI, NPQ and COM were consistent with the external criterion for disability, whereas only those from NDI were consistent with the one for pain. Correlations with VAS, CSQ and SF-12 were similar for NDI and NPQ (absolute values between 0.36 and 0.50 on day 1, between 0.38 and 0.70 on day 15), and slightly lower for COM (between 0.36 and 0.48 on day 1, and between 0.33 and 0.61 on day 15). Correlation between NDI and NPQ: r = 0.84 on day 1, r = 0.91 on day 15. Correlation between COM and NPQ: r = 0.63 on day 1, r = 0.71 on day 15.Conclusion: Although most psychometric characteristics of NDI, NPQ and COM are similar, those from the latter one are worse and its use may lead to patients' evolution seeming more positive than it actually is. NDI seems to be the best instrument for measuring NP-related disability, since its results are the most consistent with patient's assessment of their own clinical status and evolution. It takes two more minutes to answer the NDI than to answer the COM, but it can be reliably filled out by the patient without assistance.
Resumo:
INTRODUCTION: The International Neuromodulation Society (INS) has determined that there is a need for guidance regarding safety and risk reduction for implantable neurostimulation devices. The INS convened an international committee of experts in the field to explore the evidence and clinical experience regarding safety, risks, and steps to risk reduction to improve outcomes. METHODS: The Neuromodulation Appropriateness Consensus Committee (NACC) reviewed the world literature in English by searching MEDLINE, PubMed, and Google Scholar to evaluate the evidence for ways to reduce risks of neurostimulation therapies. This evidence, obtained from the relevant literature, and clinical experience obtained from the convened consensus panel were used to make final recommendations on improving safety and reducing risks. RESULTS: The NACC determined that the ability to reduce risk associated with the use of neurostimulation devices is a valuable goal and possible with best practice. The NACC has recommended several practice modifications that will lead to improved care. The NACC also sets out the minimum training standards necessary to become an implanting physician. CONCLUSIONS: The NACC has identified the possibility of improving patient care and safety through practice modification. We recommend that all implanting physicians review this guidance and consider adapting their practice accordingly.
Resumo:
ABSTRACT. A dual-wavelength digital holographic microscope to measure absolute volume of living cells is proposed. The optical setup allows us to reconstruct two quantitative phase contrast images at two different wavelengths from a single hologram acquisition. When adding the absorbing dye fast green FCF as a dispersive agent to the extracellular medium, cellular thickness can be univocally determined in the full field of view. In addition to the absolute cell volume, the method can be applied to derive important biophysical parameters of living cells including osmotic membrane water permeability coefficient and the integral intracellular refractive index (RI). Further, the RI of transmembrane flux can be determined giving an indication about the nature of transported solutes. The proposed method is applied to cultured human embryonic kidney cells, Chinese hamster ovary cells, human red blood cells, mouse cortical astrocytes, and neurons.
Resumo:
STUDY DESIGN: Randomized controlled trial with 1-year follow-up. OBJECTIVE: To analyze the effects of an exercise program or routine follow-up on patients with chronic low back pain who have completed functional multidisciplinary rehabilitation. The short- and long-term outcome in terms of symptoms and physical and social functioning was compared. SUMMARY OF BACKGROUND DATA: Systematic reviews have shown that functional multidisciplinary rehabilitation improves physical function and reduces pain in patients with chronic low back pain. However, long-term maintenance of these improvements is inconsistent and the role of exercise in achieving this goal is unclear. METHODS: One hundred five chronic patients with low back pain who had completed a 3-week functional multidisciplinary rehabilitation program were randomized to either a 3-month exercise program (n = 56) or routine follow-up (n = 49). The exercise program consisted of 24 training sessions during 12 weeks. Patients underwent evaluations of trunk muscle endurance, cardiovascular endurance, lumbar spine mobility (flexion and extension range-of-motion, fingertip-to-floor distance), pain and perceived functional ability at the beginning and the end of functional multidisciplinary rehabilitation, at the end of the exercise program (3 months) and at 1-year follow-up. Disability was also assessed at the same time points except at the beginning of functional multidisciplinary rehabilitation. RESULTS: At the end of the functional multidisciplinary rehabilitation, both groups improved significantly in all physical parameters except flexion and extension range-of-motion. At the 3 month and 1 year follow-up, both groups maintained improvements in all parameters except for cardiovascular endurance. Only the exercise program group improved in disability score and trunk muscle endurance. No differences between groups were found. CONCLUSION: A favorable long-term outcome was observed after functional multidisciplinary rehabilitation in both patient groups. Patients who participated in an exercise program obtained some additional benefits. The relevance of these benefits to overall health status need to be further investigated.
Resumo:
OBJECTIVE: The estimation of blood pressure is dependent on the accuracy of the measurement devices. We compared blood pressure readings obtained with an automated oscillometric arm-cuff device and with an automated oscillometric wrist-cuff device and then assessed the prevalence of defined blood pressure categories. METHODS: Within a population-based survey in Dar es Salaam (Tanzania), we selected all participants with a blood pressure >/= 160/95 mmHg (n=653) and a random sample of participants with blood pressure <160/95 mmHg (n=662), based on the first blood pressure reading. Blood pressure was reassessed 2 years later for 464 and 410 of the participants, respectively. In these 874 subjects, we compared the prevalence of blood pressure categories as estimated with each device. RESULTS: Overall, the wrist device gave higher blood pressure readings than the arm device (difference in systolic/diastolic blood pressure: 6.3 +/- 17.3/3.7 +/- 11.8 mmHg, P<0.001). However, the arm device tended to give lower readings than the wrist device for high blood pressure values. The prevalence of blood pressure categories differed substantially depending on which device was used, 29% and 14% for blood pressure <120/80 mmHg (arm device versus wrist device, respectively), 30% and 33% for blood pressure 120-139/80-89 mmHg, 17% and 26% for blood pressure 140-159/90-99 mmHg, 12% and 13% for blood pressure 160-179/100-109 mmHg and 13% and 14% for blood pressure >/= 180/110 mmHg. CONCLUSIONS: A large discrepancy in the estimated prevalence of blood pressure categories was observed using two different automatic measurement devices. This emphasizes that prevalence estimates based on automatic devices should be considered with caution.
Resumo:
This article summarizes the available evidence on the management of patients with subacute or chronic low back pain. The largest part is devoted to nonspecific low back pain but the models of spinal stenosis and disk herniation/sciatica are also specifically addressed. The authors point out the limited evidence available and the importance of a tailored approach for the individual patient. As the effect sizes of most therapies are rather small (close to that of a placebo), patients' preferences and other variables important for individualized management are highlighted. The task for the practitioner is difficult and awareness of this is important. Some speculation regarding potential future ways of improving patient care are presented.
Resumo:
Neuronal hyperexcitability following peripheral nerve lesions may stem from altered activity of voltage-gated sodium channels (VGSCs), which gives rise to allodynia or hyperalgesia. In vitro, the ubiquitin ligase Nedd4-2 is a negative regulator of VGSC α-subunits (Na(v)), in particular Na(v)1.7, a key actor in nociceptor excitability. We therefore studied Nedd4-2 in rat nociceptors, its co-expression with Na(v)1.7 and Na(v)1.8, and its regulation in pathology. Adult rats were submitted to the spared nerve injury (SNI) model of neuropathic pain or injected with complete Freund's adjuvant (CFA), a model of inflammatory pain. L4 dorsal root ganglia (DRG) were analyzed in sham-operated animals, seven days after SNI and 48h after CFA with immunofluorescence and Western blot. We observed Nedd4-2 expression in almost 50% of DRG neurons, mostly small and medium-sized. A preponderant localization is found in the non-peptidergic sub-population. Additionally, 55.7±2.7% and 55.0±3.6% of Nedd4-2-positive cells are co-labeled with Na(v)1.7 and Na(v)1.8 respectively. SNI significantly decreases the proportion of Nedd4-2-positive neurons from 45.9±1.9% to 33.5±0.7% (p<0.01) and the total Nedd4-2 protein to 44%±0.13% of its basal level (p<0.01, n=4 animals in each group, mean±SEM). In contrast, no change in Nedd4-2 was found after peripheral inflammation induced by CFA. These results indicate that Nedd4-2 is present in nociceptive neurons, is downregulated after peripheral nerve injury, and might therefore contribute to the dysregulation of Na(v)s involved in the hyperexcitability associated with peripheral nerve injuries.
Resumo:
The advances of the semiconductor industry enable microelectromechanical systems sensors, signal conditioning logic and network access to be integrated into a smart sensor node. In this framework, a mixed-mode interface circuit for monolithically integrated gas sensor arrays was developed with high-level design techniques. This interface system includes analog electronics for inspection of up to four sensor arrays and digital logic for smart control and data communication. Although different design methodologies were used in the conception of the complete circuit, high-level synthesis tools and methodologies were crucial in speeding up the whole design cycle, enhancing reusability for future applications and producing a flexible and robust component.