905 resultados para Output fluctuations
Resumo:
BACKGROUND: Control of breathing, heart rate, and body temperature are interdependent in infants, where instabilities in thermoregulation can contribute to apneas or even life-threatening events. Identifying abnormalities in thermoregulation is particularly important in the first 6 months of life, where autonomic regulation undergoes critical development. Fluctuations in body temperature have been shown to be sensitive to maturational stage as well as system failure in critically ill patients. We thus aimed to investigate the existence of fractal-like long-range correlations, indicative of temperature control, in night time rectal temperature (T(rec)) patterns in maturing infants. METHODOLOGY/PRINCIPAL FINDINGS: We measured T(rec) fluctuations in infants every 4 weeks from 4 to 20 weeks of age and before and after immunization. Long-range correlations in the temperature series were quantified by the correlation exponent, alpha using detrended fluctuation analysis. The effects of maturation, room temperature, and immunization on the strength of correlation were investigated. We found that T(rec) fluctuations exhibit fractal long-range correlations with a mean (SD) alpha of 1.51 (0.11), indicating that T(rec) is regulated in a highly correlated and hence deterministic manner. A significant increase in alpha with age from 1.42 (0.07) at 4 weeks to 1.58 (0.04) at 20 weeks reflects a change in long-range correlation behavior with maturation towards a smoother and more deterministic temperature regulation, potentially due to the decrease in surface area to body weight ratio in the maturing infant. alpha was not associated with mean room temperature or influenced by immunization CONCLUSIONS: This study shows that the quantification of long-range correlations using alpha derived from detrended fluctuation analysis is an observer-independent tool which can distinguish developmental stages of night time T(rec) pattern in young infants, reflective of maturation of the autonomic system. Detrended fluctuation analysis may prove useful for characterizing thermoregulation in premature and other infants at risk for life-threatening events.
Resumo:
The purpose of this study was to compare the validity and output of the biaxial ActiGraph GT1M and the triaxial GT3X (ActiGraph, LLC, Pensacola, FL, USA)accelerometer in 5- to 9-year-old children. Thirty-two children wore the two monitors while their energy expenditure was measured with indirect calorimetry. They performed four locomotor and four play activities in an exercise laboratory and were further measured during 12 minutes of a sports lesson. Validity evidence in relation to indirect calorimetry was examined with linear regression equations applied to the laboratory data. During the sports lessons predicted energy expenditure according to the regression equations was compared to measured energy expenditure with the Wilcoxon-signed rank test and the Spearman correlation. To compare the output, agreement between counts of the two monitors during the laboratory activities was assessed with Bland-Altman plots. The evidence of validity was similar for both monitors. Agreement between the output of the two monitors was good for vertical counts (mean bias = −14 ± 22 counts) but not for horizontal counts (−17 ± 32 counts). The current results indicate that the two accelerometer models are able to estimate energy expenditure of a range of physical activities equally well in young children. However, they show output differences for movement in the horizontal direction.
Resumo:
Fluctuations in consciousness and visual hallucinations are common neuropsychiatric features of dementia with Lewy bodies and Parkinson's disease dementia. To investigate potential neural correlates, we compared how changes in brain perfusion over a 1-year period were related to changes in the severity of these key clinical features. We recruited 29 subjects with either Parkinson's disease with dementia (15 subjects) or dementia with Lewy bodies (14 subjects). Cerebral perfusion was measured using HMPAO SPECT at baseline, and repeated 1 year later. The presence of hallucinations (Neuropsychiatric Inventory), severity of fluctuations in consciousness (fluctuation assessment scale) and cognitive ability (CAMCOG) were assessed at both time points. After controlling for changes in cognitive ability and effect of cholinesterase medication, we found a significant correlation between an increase in perfusion in midline posterior cingulate and decrease in hallucination severity. There was also a significant correlation between increased fluctuations of consciousness and increased thalamic and decreased inferior occipital perfusion. We have identified important neural correlates of key clinical features in Lewy body dementia and postulate that the associations can be understood through the influence of the cholinergic system on attention.
Resumo:
Bone-anchored hearing implants (BAHI) are routinely used to alleviate the effects of the acoustic head shadow in single-sided sensorineural deafness (SSD). In this study, the influence of the directional microphone setting and the maximum power output of the BAHI sound processor on speech understanding in noise in a laboratory setting were investigated. Eight adult BAHI users with SSD participated in this pilot study. Speech understanding in noise was measured using a new Slovak speech-in-noise test in two different spatial settings, either with noise coming from the front and noise from the side of the BAHI (S90N0) or vice versa (S0N90). In both spatial settings, speech understanding was measured without a BAHI, with a Baha BP100 in omnidirectional mode, with a BP100 in directional mode, with a BP110 power in omnidirectional and with a BP110 power in directional mode. In spatial setting S90N0, speech understanding in noise with either sound processor and in either directional mode was improved by 2.2-2.8 dB (p = 0.004-0.016). In spatial setting S0N90, speech understanding in noise was reduced by either BAHI, but was significantly better by 1.0-1.8 dB, if the directional microphone system was activated (p = 0.046), when compared to the omnidirectional setting. With the limited number of subjects in this study, no statistically significant differences were found between the two sound processors.
Resumo:
Abstract. Ancient Lake Ohrid is a steep-sided, oligotrophic, karst lake that was tectonically formed most likely within the Pliocene and often referred to as a hotspot of endemic biodiversity. This study aims on tracing significant lake level fluctuations at Lake Ohrid using high-resolution acoustic data in combination with lithological, geochemical, and chronological information from two sediment cores recovered from sub-aquatic terrace levels at ca. 32 and 60m water depth. According to our data, significant lake level fluctuations with prominent lowstands of ca. 60 and 35m below the present water level occurred during Marine Isotope Stage (MIS) 6 and MIS 5, respectively. The effect of these lowstands on biodiversity in most coastal parts of the lake is negligible, due to only small changes in lake surface area, coastline, and habitat. In contrast, biodiversity in shallower areas was more severely affected due to disconnection of today sublacustrine springs from the main water body. Multichannel seismic data from deeper parts of the lake clearly image several clinoform structures stacked on top of each other. These stacked clinoforms indicate significantly lower lake levels prior to MIS 6 and a stepwise rise of water level with intermittent stillstands since its existence as water-filled body, which might have caused enhanced expansion of endemic species within Lake Ohrid.
Resumo:
BACKGROUND: Cardiac output (CO) measurement with lithium dilution (COLD) has not been fully validated in sheep using precise ultrasonic flow probe technology (COUFP). Sheep generate important cardiovascular research models and the use of COLD has become more popular in experimental settings. METHODS: Ultrasonic transit-time perivascular flow probes were surgically implanted on the pulmonary artery of 13 sheep. Paired COLD readings were taken at six time points, before and after implantation of a left ventricular assist device (LVAD) and compared with COUFP recorded just after lithium injection. RESULTS: The mean COLD was 5.7 litre min(-1) (range 3.8-9.6 litre min(-1)) and mean COUFP 5.9 litre min(-1) (range 4.0-9.2 litre min(-1)). The bias (standard deviation) was 0.3 (1.0) litre min(-1) [5.1 (16.9)%] and limits of agreement (LOA) were -1.7 to 2.3 litre min(-1) (-28.8 to 39.0%) with a percentage error (PE) of 34.4%. Data to assess trending [rate (95% confidence intervals)] included a 78 (62-93)% concordance rate in the four-quadrant plot (n=27). In the half moon polar plot (n=19), the mean polar angle was +5°, the radial LOA were -49 to +35° and 68 (47-89)% of data points fell within 22.5° of the mean polar angle. Both tests indicated moderate to poor trending ability. CONCLUSION: COLD is not precise when evaluated against COUFP in sheep based on the statistical criteria set, but the results are comparable with previously published animal studies. KEYWORDS: