998 resultados para NERVE MONITORING


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Enteral glutamine supplementation and antioxidants have been shown to be beneficial in some categories of critically ill patients. This study investigated the impact on organ function and clinical outcome of an enteral solution enriched with glutamine and antioxidant micronutrients in patients with trauma and with burns. METHODS: This was a prospective study of a historical control group including critically ill, burned and major trauma patients (n = 86, 40 patients with burns and 46 with trauma, 43 in each group) on admission to an intensive care unit in a university hospital (matching for severity, age, and sex). The intervention aimed to deliver a 500-mL enteral solution containing 30 g of glutamine per day, selenium, zinc, and vitamin E (Gln-AOX) for a maximum of 10 d, in addition to control treatment consisting of enteral nutrition in all patients and intravenous trace elements in all burn patients. RESULTS: Patients were comparable at baseline, except for more inhalation injuries in the burn-Gln-AOX group (P = 0.10) and greater neurologic impairment in the trauma-Gln-AOX group (P = 0.022). Intestinal tolerance was good. The full 500-mL dose was rarely delivered, resulting in a low mean glutamine daily dose (22 g for burn patients and 16 g for trauma patients). In burn patients intravenous trace element delivery was superior to the enteral dose. The evolution of the Sequential Organ Failure Assessment score and other outcome variables did not differ significantly between groups. C-reactive protein decreased faster in the Gln-AOX group. CONCLUSION: The Gln-AOX supplement was well tolerated in critically ill, injured patients, but did not improve outcome significantly. The delivery of glutamine below the 0.5-g/kg recommended dose in association with high intravenous trace element substitution doses in burn patients are likely to have blunted the impact by not reaching an efficient treatment dose. Further trials testing higher doses of Gln are required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This form requests the minimum information required to demonstrate the extent of compliance with section 223(a)(11), 223(a)(12), 223(a)(13), 223(a)(14) of the JJDP Act of 2002. Many of these reporting requirements may be found in 28 C.F.R. 31.303(f)(5).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This form requests the minimum information required to demonstrate the extent of compliance with section 223(a)(11), 223(a)(12), 223(a)(13), 223(a)(14) of the JJDP Act of 2002. Many of these reporting requirements may be found in 28 C.F.R. 31.303(f)(5).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Poor long-term adherence is an important cause of uncontrolled hypertension. We examined whether monitoring drug adherence with an electronic system improves long-term blood pressure (BP) control in hypertensive patients followed by general practitioners (GPs). METHODS: A pragmatic cluster randomised controlled study was conducted over one year in community pharmacists/GPs' networks randomly assigned either to usual care (UC) where drugs were dispensed as usual, or to intervention (INT) group where drug adherence could be monitored with an electronic system (Medication Event Monitoring System). No therapy change was allowed during the first 2 months in both groups. Thereafter, GPs could modify therapy and use electronic monitors freely in the INT group. The primary outcome was a target office BP<140/90 mmHg. RESULTS: Sixty-eight treated uncontrolled hypertensive patients (UC: 34; INT: 34) were enrolled. Over the 12-month period, the likelihood of reaching the target BP was higher in the INT group compared to the UC group (p<0.05). At 4 months, 38% in the INT group reached the target BP vs. 12% in the UC group (p<0.05), and 21% vs. 9% at 12 months (p: ns). Multivariate analyses, taking account of baseline characteristics, therapy modification during follow-up, and clustering effects by network, indicate that being allocated to the INT group was associated with a greater odds of reaching the target BP at 4 months (p<0.01) and at 12 months (p=0.051). CONCLUSION: GPs monitoring drug adherence in collaboration with pharmacists achieved a better BP control in hypertensive patients, although the impact of monitoring decreased with time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The toxicity of yew (Taxus spp) is well known from ancient times and is mainly due to taxins acting as inhibitors of calcium and sodium transport across the cell membrane of cardiac myocytes. The confirmation of yew taxins in body fluids can be carried out by liquid chromatography-tandem mass spectrometry (LC-MS/MS). However, before selecting this precise but expensive technique, an orientation test should be done to ascertain yew presence as toxic agent in the organism. As the 3,5-dimethoxyphenol (3,5-DMP), myrtenol and 1-octen-3-ol appear as glycosidically bound volatile compounds and are very yew specific, the detection of 3,5-DMP and the measurement of 1-octen-3-ol / myrtenol concentration ratio constitute reliable indicators of yew presence in forensic cases. The detection of these compounds is easily performed by gas chromatography-mass spectrometry (GC-MS) (SIM) after an enzymatic hydrolysis (β-glucosidase) allowing the release of volatile compounds from yew glycosides. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a patient with adult-onset Rasmussen's encephalitis (RE) responsive to vagus nerve stimulation. This previously healthy woman developed RE in the right hemisphere at the age of 27. Despite antiepileptic drug polytherapy, she continued to experience subcontinuous, simple-partial left-sided motor seizures and slowly progressive cognitive impairment. Resective surgery was not considered owing to the preservation of left motor skills. She was implanted with a vagus nerve stimulator at the age of 41; after 6 months she experienced a greater than 50% reduction in seizure frequency, which persisted over 2 years together with improvement of her neurological and cognitive status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The addition of nerve growth factor (2.5S NGF) to serum-free aggregating cell cultures of fetal rat telencephalon greatly stimulated the developmental increase in choline acetyltransferase activity. Two other neuronal enzymes, acetylcholinesterase and glutamic acid decarboxylase, showed only slightly increased activities after NGF treatment whereas the total protein content of the cultures and the activity of 2',3'- cyclic nucleotide phosphodiesterase remained unchanged. The stimulation of choline acetyltransferase was dependent on the NGF media concentrations, showing a 50% maximum effect (120% increase) at approximately 3 ng/ml (10-10 M 2.5S NGF). NGF treatments during different culture periods showed that the cholinergic neurons remained responsive for at least 19 days. The continued treatment was the most effective; however, an initial treatment for only 5 days still caused a significant stimulation of choline acetyltransferase on day 19. The observed stimulation appeared to be specific to NGF. Univalent antibody fragments (Fab) against 2.5S NGF completely abolished the NGF-dependent increase in choline acetyltransferase activity, whereas Fab fragments of control IgG were ineffective. Furthermore, angiotensin II, added in high amounts to the cultures, showed no stimulatory effect. The present results suggest that certain populations of rat brain neurons are responsive to nerve growth factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper presents a novel method for monitoring network optimisation, based on a recent machine learning technique known as support vector machine. It is problem-oriented in the sense that it directly answers the question of whether the advised spatial location is important for the classification model. The method can be used to increase the accuracy of classification models by taking a small number of additional measurements. Traditionally, network optimisation is performed by means of the analysis of the kriging variances. The comparison of the method with the traditional approach is presented on a real case study with climate data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case study deals with a rock face monitoring in urban areas using a Terrestrial Laser Scanner. The pilot study area is an almost vertical, fifty meter high cliff, on top of which the village of Castellfollit de la Roca is located. Rockfall activity is currently causing a retreat of the rock face, which may endanger the houses located at its edge. TLS datasets consist of high density 3-D point clouds acquired from five stations, nine times in a time span of 22 months (from March 2006 to January 2008). The change detection, i.e. rockfalls, was performed through a sequential comparison of datasets. Two types of mass movement were detected in the monitoring period: (a) detachment of single basaltic columns, with magnitudes below 1.5 m3 and (b) detachment of groups of columns, with magnitudes of 1.5 to 150 m3. Furthermore, the historical record revealed (c) the occurrence of slab failures with magnitudes higher than 150 m3. Displacements of a likely slab failure were measured, suggesting an apparent stationary stage. Even failures are clearly episodic, our results, together with the study of the historical record, enabled us to estimate a mean detachment of material from 46 to 91.5 m3 year¿1. The application of TLS considerably improved our understanding of rockfall phenomena in the study area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper analyses and compares infrasonic and seismic data from snow avalanches monitored at the Vallée de la Sionne test site in Switzerland from 2009 to 2010. Using a combination of seismic and infrasound sensors, it is possible not only to detect a snow avalanche but also to distinguish between the different flow regimes and to analyse duration, average speed (for sections of the avalanche path) and avalanche size. Different sensitiveness of the seismic and infrasound sensors to the avalanche regimes is shown. Furthermore, the high amplitudes observed in the infrasound signal for one avalanche were modelled assuming that the suspension layer of the avalanche acts as a moving turbulent sound source. Our results show reproducibility for similar avalanches on the same avalanche path.