992 resultados para Mehmed II, Sultan of the Turks, 1432-1481.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS To assess serially the edge vascular response (EVR) of a bioresorbable vascular scaffold (BVS) compared to a metallic everolimus-eluting stent (EES). METHODS AND RESULTS Non-serial evaluations of the Absorb BVS at one year have previously demonstrated proximal edge constrictive remodelling and distal edge changes in plaque composition with increase of the percent fibro-fatty (FF) tissue component. The 5 mm proximal and distal segments adjacent to the implanted devices were investigated serially with intravascular ultrasound (IVUS), post procedure, at six months and at two years, from the ABSORB Cohort B1 (n=45) and the SPIRIT II (n=113) trials. Twenty-two proximal and twenty-four distal edge segments were available for analysis in the ABSORB Cohort B1 trial. In the SPIRIT II trial, thirty-three proximal and forty-six distal edge segments were analysed. At the 5-mm proximal edge, the vessels treated with an Absorb BVS from post procedure to two years demonstrated a lumen loss (LL) of 6.68% (-17.33; 2.08) (p=0.027) with a trend toward plaque area increase of 7.55% (-4.68; 27.11) (p=0.06). At the 5-mm distal edge no major changes were evident at either time point. At the 5-mm proximal edge the vessels treated with a XIENCE V EES from post procedure to two years did not show any signs of LL, only plaque area decrease of 6.90% (-17.86; 4.23) (p=0.035). At the distal edge no major changes were evident with regard to either lumen area or vessel remodelling at the same time point. CONCLUSIONS The IVUS-based serial evaluation of the EVR up to two years following implantation of a bioresorbable everolimus-eluting scaffold shows a statistically significant proximal edge LL; however, this finding did not seem to have any clinical implications in the serial assessment. The upcoming imaging follow-up of the Absorb BVS at three years is anticipated to provide further information regarding the vessel wall behaviour at the edges.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Evaluation of health-related quality of life (HRQL) is important in improving the quality of patient care. The aim of this study was to determine the psychometric properties of the HeartQoL in patients with ischemic heart disease (IHD), specifically angina, myocardial infarction (MI), or ischemic heart failure. Methods: Data for the interim validation of the HeartQoL questionnaire were collected in (a) a cross-sectional survey and (b) a prospective substudy of patients undergoing either a percutaneous coronary intervention (PCI) or referred to cardiac rehabilitation (CR) and were then analyzed to determine the reliability, validity, and responsiveness of the HeartQoL questionnaire. Results: We enrolled 6384 patients (angina, n = 2111, 33.1%; MI, n = 2351, 36.8%; heart failure, n = 1922, 30.1%) across 22 countries speaking 15 languages in the cross-sectional study and 730 patients with IHD in the prospective substudy. The HeartQoL questionnaire comprises 14-items with physical and emotional subscales and a global score (range 0–3 (poor to better HRQL). Cronbach’s α was consistently ≥0.80; convergent validity correlations between similar HeartQoL and SF-36 subscales were significant (r ≥ 0.60, p < 0.001); discriminative validity was confirmed with predictor variables: health transition, anxiety, depression, and functional status. HeartQoL score changes following either PCI or CR were significant (p < 0.001) with effect sizes ranging from 0.37–0.64. Conclusion: The HeartQoL questionnaire is reliable, valid, and responsive to change allowing clinicians and researchers to (a) assess baseline HRQL, (b) make between-diagnosis comparisons of HRQL, and (c) evaluate change in HRQL in patients with angina, MI, or heart failure with a single IHD-specific HRQL instrument.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present an overview of our analyses of HiRISE observations of spring evolution of selected dune areas of the north polar erg. The north polar erg is covered annually by seasonal volatile ice layer, a mixture of CO2 and H2O with mineral dust contamination. In spring, this layer sublimes creating visually enigmatic phenomena, e.g. dark and bright fan-shaped deposits, dark–bright–dark bandings, dark down-slope streaks, and seasonal polygonal cracks. Similar phenomena in southern polar areas are believed to be related to the specific process of solid-state greenhouse effect. In the north, it is currently unclear if the solid-state greenhouse effect is able to explain all the observed phenomena especially because the increased influence of H2O on the time scales of this process has not yet been quantified. HiRISE observations of our selected locations show that the ground exhibits a temporal behaviour similar to the one observed in the southern polar areas: a brightening phase starting close to the spring equinox with a subsequent darkening towards summer solstice. The resolution of HiRISE enabled us to study dunes and substrate individually and even distinguish between different developments on windward and slip face sides of single dunes. Differences in the seasonal evolution between steep slip faces and flatter substrate and windward sides of dunes have been identified and compared to CRISM data of CO2 and H2O distributions on dunes. We also observe small scale dark blotches that appear in early observations and tend to sustain a low reflectivity throughout the spring. These blotches can be regarded as the analogue of dark fan deposits in southern polar areas, leading us to the conclusion that both martian polar areas follow similar spring evolutions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The primary objective of this trial was to evaluate the response rate for trimetrexate in conjunction with 5-FU and leucovorin (LV) (= TFL) in the treatment of advanced gastric cancer in a phase II, cooperative group setting. METHODS: Patients with locally advanced, unresectable, or metastatic adenocarcinoma of the stomach received trimetrexate 110 mg/m IV over 60 minutes day 1, followed by 5-FU 500 mg/m IV bolus and LV 200 mg/m IV over 60 minutes day 2, followed by oral LV 15 mg every 6 hours x 7 doses, all weekly for 6 weeks followed by 2 weeks of rest, continued until progression. RESULTS: Characteristics for 37 eligible patients: median age 63 (range: 23-83); male/female: 69% of 31%; performance status 0/1/2 15/20/1. The confirmed response rate was 19%, and median overall survival was 6 months. Two patients died as a result of therapy, 1 because of infection without significant neutropenia, and 1 due to perforation of a responding gastric lesion. Seventy-two percent experienced grades 3 and 4 toxicity, most commonly diarrhea, fatigue, and lymphopenia. CONCLUSIONS: This regimen achieves response rates comparable to other 5-FU-based regimens, when used in treatment of incurable gastric cancer. Toxicity appears manageable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Excavated by French Egyptologist P. Montet in the 1920s, Royal Tomb II at Byblos (Bronze Age Gubla) yielded a significant number of Egyptian objects of the Middle Kingdom. Among these finds is a stone vessel with lid that carries the cartouche of a king named Amenemhat, often believed to be Amenemhat IV of the late Middle Kingdom. Hitherto unnoticed by the scholarly community, however, are two Egyptian measure capacity signs on the stone vessel itself. Since measure capacity signs on stone vessels dating to the Middle Kingdom are only rarely attested even in Egypt, the signs on the stone vessel from Royal Tomb II at Byblos therefore contribute considerably to our understanding of the use and application of such signs. The article deals with the examination of these signs and tries to correlate them with the actual capacity of the vessel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The interaction between sensory rhodopsin II (SRII) and its transducer HtrII was studied by the time-resolved laser-induced transient grating method using the D75N mutant of SRII, which exhibits minimal visible light absorption changes during its photocycle, but mediates normal phototaxis responses. Flash-induced transient absorption spectra of transducer-free D75N and D75N joined to 120 amino-acid residues of the N-terminal part of the SRII transducer protein HtrII (DeltaHtrII) showed only one spectrally distinct K-like intermediate in their photocycles, but the transient grating method resolved four intermediates (K(1)-K(4)) distinct in their volumes. D75N bound to HtrII exhibited one additional slower kinetic species, which persists after complete recovery of the initial state as assessed by absorption changes in the UV-visible region. The kinetics indicate a conformationally changed form of the transducer portion (designated Tr*), which persists after the photoreceptor returns to the unphotolyzed state. The largest conformational change in the DeltaHtrII portion was found to cause a DeltaHtrII-dependent increase in volume rising in 8 micros in the K(4) state and a drastic decrease in the diffusion coefficient (D) of K(4) relatively to those of the unphotolyzed state and Tr*. The magnitude of the decrease in D indicates a large structural change, presumably in the solvent-exposed HAMP domain of DeltaHtrII, where rearrangement of interacting molecules in the solvent would substantially change friction between the protein and the solvent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Understanding the principles of calmodulin (CaM) activation of target enzymes will help delineate how this seemingly simple molecule can play such a complex role in transducing Ca (2+)-signals to a variety of downstream pathways. In the work reported here, we use biochemical and biophysical tools and a panel of CaM constructs to examine the lobe specific interactions between CaM and CaMKII necessary for the activation and autophosphorylation of the enzyme. Interestingly, the N-terminal lobe of CaM by itself was able to partially activate and allow autophosphorylation of CaMKII while the C-terminal lobe was inactive. When used together, CaMN and CaMC produced maximal CaMKII activation and autophosphorylation. Moreover, CaMNN and CaMCC (chimeras of the two N- or C-terminal lobes) both activated the kinase but with greater K act than for wtCaM. Isothermal titration calorimetry experiments showed the same rank order of affinities of wtCaM > CaMNN > CaMCC as those determined in the activity assay and that the CaM to CaMKII subunit binding ratio was 1:1. Together, our results lead to a proposed sequential mechanism to describe the activation pathway of CaMKII led by binding of the N-lobe followed by the C-lobe. This mechanism contrasts the typical sequential binding mode of CaM with other CaM-dependent enzymes, where the C-lobe of CaM binds first. The consequence of such lobe specific binding mechanisms is discussed in relation to the differential rates of Ca (2+)-binding to each lobe of CaM during intracellular Ca (2+) oscillations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The invariant chain associated with the major histocompatibility complex (MHC) class II molecules is a non-polymorphic glycoprotein implicated in antigen processing and class II molecule intracellular transport. Class II molecules and invariant chain (In) are expressed primarily by B lymphocytes and antigen-presenting cells such as macrophages and can be induced by interferon gamma (IFN-$\gamma$) in a variety of cell types such as endothelial cells, fibroblasts, and astrocytes. In this study the cis-acting sequences involved in the constitutive, tissue-specific, and IFN-$\gamma$ induced expression of the human In gene were investigated and nuclear proteins which specifically bound these sequences were identified.^ To define promoter sequences involved in the regulation of the human In gene, 790 bp 5$\sp\prime$ to the initiation of transcription were subcloned upstream of the gene encoding chloramphenicol acetyl transferase (CAT). Transfection of this construct into In expressing and non-expressing cell lines demonstrated that this 790 bp In promoter sequence conferred tissue specificity to the CAT gene. Deletion mutants were created in the promoter to identify sequences important for transcription. Three regulatory regions were identified $-$396 to $-$241, $-$241 to $-$216, and $-$216 to $-$165 bp 5$\sp\prime$ to the cap site. Transfection into a human glioblastoma cell line, U-373 MG, and treatment with IFN-$\gamma$, demonstrated that this 5$\sp\prime$ region is responsive to IFN-$\gamma$. An IFN-$\gamma$ response element was sublocalized to the region $-$120 to $-$61 bp. This region contains homology to the interferon-stimulated response element (ISRE) identified in other IFN responsive genes. IFN-$\gamma$ induces a sequence-specific DNA binding factor which binds to an oligonucleotide corresponding to $-$107 to $-$79 bp of the In promoter. This factor also binds to an oligonucleotide corresponding to $-$91 to $-$62 of the interferon-$\beta$ gene promoter, suggesting this factor may be member of the IRF-1/ISGF2, IRF-2, ICSBP family of ISRE binding proteins. A transcriptional enhancer was identified in the first intron of the In gene. This element, located in a 2.6 kb BamHI/PstI fragment, enhances the IFN-$\gamma$ response of the promoter in U-373 MG. The majority of the In enhancer activity was sublocalized to a 550 bp region $\sim$1.6 kb downstream of the In transcriptional start site. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) as well as thoracic and abdominal endovascular aortic repair (TEVAR and EVAR) rely on accurate pre- and postprocedural imaging. This review article discusses the application of imaging, including preprocedural assessment and measurements as well as postprocedural imaging of complications. Furthermore, the exciting perspective of computational fluid dynamics (CFD) based on cross-sectional imaging is presented. TAVR is a minimally invasive alternative for treatment of aortic valve stenosis in patients with high age and multiple comorbidities who cannot undergo traditional open surgical repair. Given the lack of direct visualization during the procedure, pre- and peri-procedural imaging forms an essential part of the intervention. Computed tomography angiography (CTA) is the imaging modality of choice for preprocedural planning. Routine postprocedural follow-up is performed by echocardiography to confirm treatment success and detect complications. EVAR and TEVAR are minimally invasive alternatives to open surgical repair of aortic pathologies. CTA constitutes the preferred imaging modality for both preoperative planning and postoperative follow-up including detection of endoleaks. Magnetic resonance imaging is an excellent alternative to CT for postoperative follow-up, and is especially beneficial for younger patients given the lack of radiation. Ultrasound is applied in screening and postoperative follow-up of abdominal aortic aneurysms, but cross-sectional imaging is required once abnormalities are detected. Contrast-enhanced ultrasound may be as sensitive as CTA in detecting endoleaks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Second-generation everolimus-eluting stents (EES) and third generation biolimus-eluting stents (BES) have been shown to be superior to first-generation paclitaxel-eluting stents (PES) and second-generation sirolimus-eluting stents (SES). However, neointimal proliferation and very late stent thrombosis is still an unresolved issue of drug-eluting stent (DES) implantation overall. The Absorb™ (Abbott Vascular, Abbott Park, IL, USA) is the first CE approved DES with a bioresorbable vascular scaffold (BVS) thought to reduce long-term complication rates. The EVERBIO II trial was set up to compare the BVS safety and efficacy with both EES and BES in all patients viable for inclusion. METHODS/DESIGN: The EVERBIO II trial is a single-center, assessor-blinded, randomized trial. The study population consists of all patients aged≥18 years old undergoing percutaneous coronary intervention. Exclusion criterion is where the lesion cannot be treated with BVS (reference vessel diameter>4.0 mm). A total of 240 patients will be enrolled and randomly assigned into 3 groups of 80 with either BVS, EES or BES implantation. All patients will undergo a follow-up angiography study at 9 months. Clinical follow-up for up to 5 years will be conducted by telephone. The primary endpoint is in-segment late lumen loss at 9 months measured by quantitative coronary angiography. Secondary endpoints are patient-oriented major adverse cardiac event (MACE) (death, myocardial infarction and target-vessel revascularization), device-oriented MACE (cardiac death, myocardial infarction and target-lesion revascularization), stent thrombosis according to ARC and binary restenosis at follow-up 12 months angiography. DISCUSSION: EVERBIO II is an independent, randomized study, aiming to compare the clinical efficacy, angiographic outcomes and safety of BVS, EES and BES in all comer patients. TRIAL REGISTRATION: The trial listed in clinicaltrials.gov as NCT01711931.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Biodegradable polymers for release of antiproliferative drugs from drug-eluting stents aim to improve vascular healing. We assessed noninferiority of a novel ultrathin strut drug-eluting stent releasing sirolimus from a biodegradable polymer (Orsiro, O-SES) compared with the durable polymer Xience Prime everolimus-eluting stent (X-EES) in terms of the primary end point in-stent late lumen loss at 9 months. METHODS AND RESULTS A total of 452 patients were randomly assigned 2:1 to treatment with O-SES (298 patients, 332 lesions) or X-EES (154 patients, 173 lesions) in a multicenter, noninferiority trial. The primary end point was in-stent late loss at 9 months. O-SES was noninferior to X-EES for the primary end point (0.10±0.32 versus 0.11±0.29 mm; difference=0.00063 mm; 95% confidence interval, -0.06 to 0.07; Pnoninferiority<0.0001). Clinical outcome showed similar rates of target-lesion failure at 1 year (O-SES 6.5% versus X-EES 8.0%; hazard ratio=0.82; 95% confidence interval, 0.40-1.68; log-rank test: P=0.58) without cases of stent thrombosis. A subgroup of patients (n=55) underwent serial optical coherence tomography at 9 months, which demonstrated similar neointimal thickness among lesions allocated to O-SES and X-EES (0.10±0.04 mm versus 0.11±0.04 mm; -0.01 [-0.04, -0.01]; P=0.37). Another subgroup of patients (n=56) underwent serial intravascular ultrasound at baseline and 9 months indicating a potential difference in neointimal area at follow-up (O-SES, 0.16±0.33 mm(2) versus X-EES, 0.43±0.56 mm(2); P=0.04). CONCLUSIONS Compared with durable polymer X-EES, novel biodegradable polymer-based O-SES was found noninferior for the primary end point in-stent late lumen loss at 9 months. Clinical event rates were comparable without cases of stent thrombosis throughout 1 year of follow-up. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01356888.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three-dimensional oxalate-based {[Ru(bpy)3][Cu2xNi2(1-x)(ox)3]}n (0≤ x ≤ 1, ox = C2O42-, bpy = 2,2‘bipyridine) were synthesized. The structure was determined for x = 1 by X-ray diffraction on single crystal. The compound crystallizes in the cubic space group P4132. It shows a three-dimensional 10-gon 3-connected (10,3) anionic network where copper(II) has an unusual tris(bischelated) environment. X-ray powder diffraction patterns and their Rietveld refinement show that all the compounds along the series are isostructural and single-phased. According to X-ray absorption spectroscopy, copper(II) and nickel(II) have an octahedral environment, respectively elongated and trigonally distorted. As shown by natural circular dichroism, the optically active forms of {[Ru(bpy)3][CuxNi2(1-x)(ox)3]}n are obtained starting from resolved Δ- or Λ-[Ru(bpy)3]2+. The Curie−Weiss temperatures range between −55 (x = 1) and −150 K (x = 0). The antiferromagnetic exchange interaction thus decreases when the copper contents increases in agreement with the crystallographic structure of the compounds and the electronic structure of the metal ions. At low temperature, the compounds exhibit complex long-range ordered magnetic behavior.