870 resultados para Medical instruments and apparatus
Resumo:
Pharmacological cognitive enhancement (CE) is a topic of increasing public awareness. In the scientific literature on studentrnuse of CE as a study aid for academic performance enhancement, there are high prevalence rates regarding the use ofrncaffeinated substances (coffee, caffeinated drinks, caffeine tablets) but remarkably lower prevalence rates regarding the usernof illicit/prescription stimulants such as amphetamines or methylphenidate. While the literature considers the reasons andrnmechanisms for these different prevalence rates from a theoretical standpoint, it lacks empirical data to account for healthyrnstudents who use both, caffeine and illicit/prescription stimulants, exclusively for the purpose of CE. Therefore, wernextensively interviewed a sample of 18 healthy university students reporting non-medical use of caffeine as well as illicit/rnprescription stimulants for the purpose of CE in a face-to-face setting about their opinions regarding differences in generalrnand morally-relevant differences between caffeine and stimulant use for CE. 44% of all participants answered that there is arngeneral difference between the use of caffeine and illicit/prescription stimulants for CE, 28% did not differentiate, 28% couldrnnot decide. Furthermore, 39% stated that there is a moral difference, 56% answered that there is no moral difference andrnone participant was not able to comment on moral aspects. Participants came to their judgements by applying threerndimensions: medical, ethical and legal. Weighing the medical, ethical and legal aspects corresponded to the students’rnindividual preferences of substances used for CE. However, their views only partly depicted evidence-based medical aspectsrnand the ethical issues involved. This result shows the need for well-directed and differentiated information to prevent thernpotentially harmful use of illicit or prescription stimulants for CE.
Resumo:
The full blood cell (FBC) count is the most common indicator of diseases. At present hematology analyzers are used for the blood cell characterization, but, recently, there has been interest in using techniques that take advantage of microscale devices and intrinsic properties of cells for increased automation and decreased cost. Microfluidic technologies offer solutions to handling and processing small volumes of blood (2-50 uL taken by finger prick) for point-of-care(PoC) applications. Several PoC blood analyzers are in use and may have applications in the fields of telemedicine, out patient monitoring and medical care in resource limited settings. They have the advantage to be easy to move and much cheaper than traditional analyzers, which require bulky instruments and consume large amount of reagents. The development of miniaturized point-of-care diagnostic tests may be enabled by chip-based technologies for cell separation and sorting. Many current diagnostic tests depend on fractionated blood components: plasma, red blood cells (RBCs), white blood cells (WBCs), and platelets. Specifically, white blood cell differentiation and counting provide valuable information for diagnostic purposes. For example, a low number of WBCs, called leukopenia, may be an indicator of bone marrow deficiency or failure, collagen- vascular diseases, disease of the liver or spleen. The leukocytosis, a high number of WBCs, may be due to anemia, infectious diseases, leukemia or tissue damage. In the laboratory of hybrid biodevices, at the University of Southampton,it was developed a functioning micro impedance cytometer technology for WBC differentiation and counting. It is capable to classify cells and particles on the base of their dielectric properties, in addition to their size, without the need of labeling, in a flow format similar to that of a traditional flow cytometer. It was demonstrated that the micro impedance cytometer system can detect and differentiate monocytes, neutrophils and lymphocytes, which are the three major human leukocyte populations. The simplicity and portability of the microfluidic impedance chip offer a range of potential applications in cell analysis including point-of-care diagnostic systems. The microfluidic device has been integrated into a sample preparation cartridge that semi-automatically performs erythrocyte lysis before leukocyte analysis. Generally erythrocytes are manually lysed according to a specific chemical lysis protocol, but this process has been automated in the cartridge. In this research work the chemical lysis protocol, defined in the patent US 5155044 A, was optimized in order to improve white blood cell differentiation and count performed by the integrated cartridge.
Resumo:
Im Jahr 1996 wurde die erste Aufnahme der menschlichen Lunge in einem Kernspintomographen unter Benutzung des hyperpolarisierten Edelgases ³He als Kontrastgas veröffentlicht. Es folgten zahlreiche medizinische Studien mit diesem neuen Lungenbildgebungsverfahren. Als Konsequenz aus dem steigenden Bedarf an hyperpolarisiertem ³He wurde am Institut für Physik der Universität Mainz ein ³He-Polarisator entwickelt, der die Versorgung dieser Studien mit polarisiertem Gas gewährleistet. Für den Fall jedoch, dass die Lungenbildgebung mit hyperpolarisiertem ³He in die medizinische Praxis übernommen wird, wären die Produktionskapazitäten der bestehenden Anlage nicht mehr ausreichend. Daher wurde im Rahmen dieser Arbeit ein kompaktes System zum Polarisieren von ³He direkt am Einsatzort entwickelt, welches als eine Art Industrieprodukt in beliebiger Stückzahl nachgebaut werden kann. So steht nun ein kompakter, mobiler ³He Polarisator zur Verfügung, dessen Produktionsrate in der Größenordnung eines Standardliters (1 l, 1 bar, Raumtemperatur) pro Stunde bei einer Polarisation von > 60% liegt.
Resumo:
Prediction of long-term disability in patients with multiple sclerosis (MS) is essential. Magnetic resonance imaging (MRI) measurement of brain volume may be of predictive value but sophisticated MRI techniques are often inaccessible in clinical practice. The corpus callosum index (CCI) is a normalized measurement that reflects changes of brain volume. We investigated medical records and 533 MRI scans at diagnosis and during clinical follow-up of 169 MS patients (mean age 42 +/- 11 years, 86% relapsing-remitting MS, time since first relapse 11 +/- 9 years). CCI at diagnosis was 0.345 +/- 0.04 and correlated with duration of disease (p = 0.002; r = -0.234) and expanded disability status scale (EDSS) score at diagnosis (r = -0.428; p < 0.001). Linear regression analyses identified age, duration of disease, relapse rate and EDSS at diagnosis as independent predictors for disability after mean of 7.1 years (Nagelkerkes' R:0.56). Annual CCI decrease was 0.01 +/- 0.02 (annual tissue loss: 1.3%). In secondary progressive MS patients, CCI decrease was double compared to that in relapsing-remitting MS patients (p = 0.04). There was a trend of greater CCI decrease in untreated patients compared to those who received disease modifying drugs (p = 0.2). CCI is an easy to use MRI marker for estimating brain atrophy in patients with MS. Brain atrophy as measured with CCI was associated with disability progression but it was not an independent predictor of long-term disability.
Virtobot--a multi-functional robotic system for 3D surface scanning and automatic post mortem biopsy
Resumo:
The Virtopsy project, a multi-disciplinary project that involves forensic science, diagnostic imaging, computer science, automation technology, telematics and biomechanics, aims to develop new techniques to improve the outcome of forensic investigations. This paper presents a new approach in the field of minimally invasive virtual autopsy for a versatile robotic system that is able to perform three-dimensional (3D) surface scans as well as post mortem image-guided soft tissue biopsies.
Resumo:
We report a case of a 78-year-old female with a proximal femur fracture caused by an accidental fall who died suddenly 1h after orthopaedic prosthesis insertion. Post-mortem computed tomography (CT) scan and histological examination of samples obtained with post-mortem percutaneous needle biopsies of both lungs were performed. Analysis of the medical history and the clinical scenario immediately before death, imaging data, and biopsy histology established the cause of death without proceeding to traditional autopsy. It was determined to be acute right ventricular failure caused by massive pulmonary fat embolism. Although further research in post-mortem imaging and post-mortem tissue sampling by needle biopsies is necessary, we conclude that the use of CT techniques and percutaneous biopsy, as additional tools, can offer a viable alternative to traditional autopsy in selected cases and may increase the number of minimally invasive forensic examinations performed in the future.
Resumo:
Root canal treatment is a frequently performed dental procedure and is carried out on teeth in which irreversible pulpitis has led to necrosis of the dental pulp. Removal of the necrotic tissue remnants and cleaning and shaping of the root canal are important phases of root canal treatment. Treatment options include the use of hand and rotary instruments and methods using ultrasonic or sonic equipment. OBJECTIVES: The objectives of this systematic review of randomized controlled trials were to determine the relative clinical effectiveness of hand instrumentation versus ultrasonic instrumentation alone or in conjunction with hand instrumentation for orthograde root canal treatment of permanent teeth. MATERIAL AND METHODS: The search strategy retrieved 226 references from the Cochrane Oral Health Group Trials Register (7), the Cochrane Central Register of Controlled Trials (CENTRAL) (12), MEDLINE (192), EMBASE (8) and LILACS (7). No language restriction was applied. The last electronic search was conducted on December 13th, 2007. Screening of eligible studies was conducted in duplicate and independently. RESULTS: Results were to be expressed as fixed-effect or random-effects models using mean differences for continuous outcomes and risk ratios for dichotomous outcomes with 95% confidence intervals. Heterogeneity was to be investigated including both clinical and methodological factors. No eligible randomized controlled trials were identified. CONCLUSIONS: This review illustrates the current lack of published or ongoing randomized controlled trials and the unavailability of high-level evidence based on clinically relevant outcomes referring to the effectiveness of ultrasonic instrumentation used alone or as an adjunct to hand instrumentation for orthograde root canal treatment. In the absence of reliable research-based evidence, clinicians should base their decisions on clinical experience, individual circumstances and in conjunction with patients' preferences where appropriate. Future randomized controlled trials might focus more closely on evaluating the effectiveness of combinations of these interventions with an emphasis on not only clinically relevant, but also patient-centered outcomes.
Resumo:
Delays in adequate antimicrobial treatment contribute to high cost and mortality in sepsis. Polymerase chain reaction (PCR) assays are used alongside conventional cultures to accelerate the identification of microorganisms. We analyze the impact on medical outcomes and healthcare costs if improved adequacy of antimicrobial therapy is achieved by providing immediate coverage after positive PCR reports.
Resumo:
Overwhelming evidence shows the quality of reporting of randomised controlled trials (RCTs) is not optimal. Without transparent reporting, readers cannot judge the reliability and validity of trial findings nor extract information for systematic reviews. Recent methodological analyses indicate that inadequate reporting and design are associated with biased estimates of treatment effects. Such systematic error is seriously damaging to RCTs, which are considered the gold standard for evaluating interventions because of their ability to minimise or avoid bias. A group of scientists and editors developed the CONSORT (Consolidated Standards of Reporting Trials) statement to improve the quality of reporting of RCTs. It was first published in 1996 and updated in 2001. The statement consists of a checklist and flow diagram that authors can use for reporting an RCT. Many leading medical journals and major international editorial groups have endorsed the CONSORT statement. The statement facilitates critical appraisal and interpretation of RCTs. During the 2001 CONSORT revision, it became clear that explanation and elaboration of the principles underlying the CONSORT statement would help investigators and others to write or appraise trial reports. A CONSORT explanation and elaboration article was published in 2001 alongside the 2001 version of the CONSORT statement. After an expert meeting in January 2007, the CONSORT statement has been further revised and is published as the CONSORT 2010 Statement. This update improves the wording and clarity of the previous checklist and incorporates recommendations related to topics that have only recently received recognition, such as selective outcome reporting bias. This explanatory and elaboration document-intended to enhance the use, understanding, and dissemination of the CONSORT statement-has also been extensively revised. It presents the meaning and rationale for each new and updated checklist item providing examples of good reporting and, where possible, references to relevant empirical studies. Several examples of flow diagrams are included. The CONSORT 2010 Statement, this revised explanatory and elaboration document, and the associated website (www.consort-statement.org) should be helpful resources to improve reporting of randomised trials.
Resumo:
Overwhelming evidence shows the quality of reporting of randomised controlled trials (RCTs) is not optimal. Without transparent reporting, readers cannot judge the reliability and validity of trial findings nor extract information for systematic reviews. Recent methodological analyses indicate that inadequate reporting and design are associated with biased estimates of treatment effects. Such systematic error is seriously damaging to RCTs, which are considered the gold standard for evaluating interventions because of their ability to minimise or avoid bias. A group of scientists and editors developed the CONSORT (Consolidated Standards of Reporting Trials) statement to improve the quality of reporting of RCTs. It was first published in 1996 and updated in 2001. The statement consists of a checklist and flow diagram that authors can use for reporting an RCT. Many leading medical journals and major international editorial groups have endorsed the CONSORT statement. The statement facilitates critical appraisal and interpretation of RCTs. During the 2001 CONSORT revision, it became clear that explanation and elaboration of the principles underlying the CONSORT statement would help investigators and others to write or appraise trial reports. A CONSORT explanation and elaboration article was published in 2001 alongside the 2001 version of the CONSORT statement. After an expert meeting in January 2007, the CONSORT statement has been further revised and is published as the CONSORT 2010 Statement. This update improves the wording and clarity of the previous checklist and incorporates recommendations related to topics that have only recently received recognition, such as selective outcome reporting bias. This explanatory and elaboration document-intended to enhance the use, understanding, and dissemination of the CONSORT statement-has also been extensively revised. It presents the meaning and rationale for each new and updated checklist item providing examples of good reporting and, where possible, references to relevant empirical studies. Several examples of flow diagrams are included. The CONSORT 2010 Statement, this revised explanatory and elaboration document, and the associated website (www.consort-statement.org) should be helpful resources to improve reporting of randomised trials.
Resumo:
SMARTDIAB is a platform designed to support the monitoring, management, and treatment of patients with type 1 diabetes mellitus (T1DM), by combining state-of-the-art approaches in the fields of database (DB) technologies, communications, simulation algorithms, and data mining. SMARTDIAB consists mainly of two units: 1) the patient unit (PU); and 2) the patient management unit (PMU), which communicate with each other for data exchange. The PMU can be accessed by the PU through the internet using devices, such as PCs/laptops with direct internet access or mobile phones via a Wi-Fi/General Packet Radio Service access network. The PU consists of an insulin pump for subcutaneous insulin infusion to the patient and a continuous glucose measurement system. The aforementioned devices running a user-friendly application gather patient's related information and transmit it to the PMU. The PMU consists of a diabetes data management system (DDMS), a decision support system (DSS) that provides risk assessment for long-term diabetes complications, and an insulin infusion advisory system (IIAS), which reside on a Web server. The DDMS can be accessed from both medical personnel and patients, with appropriate security access rights and front-end interfaces. The DDMS, apart from being used for data storage/retrieval, provides also advanced tools for the intelligent processing of the patient's data, supporting the physician in decision making, regarding the patient's treatment. The IIAS is used to close the loop between the insulin pump and the continuous glucose monitoring system, by providing the pump with the appropriate insulin infusion rate in order to keep the patient's glucose levels within predefined limits. The pilot version of the SMARTDIAB has already been implemented, while the platform's evaluation in clinical environment is being in progress.
Resumo:
The concept of chronic critical limb ischaemia (CLI) emerged late in the history of peripheral arterial occlusive disease (PAOD). The historical background and changing definitions of CLI over the last decades are important to know in order to understand why epidemiologic data are so difficult to compare between articles and over time. The prevalence of CLI is probably very high and largely underestimated, and significant differences exist between population studies and clinical series. The extremely high costs associated with management of these patients make CLI a real public health issue for the future. In the era of emerging vascular surgery in the 1950s, the initial classification of PAOD by Fontaine, with stages III and IV corresponding to CLI, was based only on clinical symptoms. Later, with increasing access to non-invasive haemodynamic measurements (ankle pressure, toe pressure), the need to prove a causal relationship between PAOD and clinical findings suggestive of CLI became a real concern, and the Rutherford classification published in 1986 included objective haemodynamic criteria. The first consensus document on CLI was published in 1991 and included clinical criteria associated with ankle and toe pressure and transcutaneous oxygen pressure (TcPO(2)) cut-off levels <50 mmHg, <30 mmHg and <10 mmHg respectively). This rigorous definition reflects an arterial insufficiency that is so severe as to cause microcirculatory changes and compromise tissue integrity, with a high rate of major amputation and mortality. The TASC I consensus document published in 2000 used less severe pressure cut-offs (≤ 50-70 mmHg, ≤ 30-50 mmHg and ≤ 30-50 mmHg respectively). The thresholds for toe pressure and especially TcPO(2) (which will be also included in TASC II consensus document) are however just below the lower limit of normality. It is therefore easy to infer that patients qualifying as CLI based on TASC criteria can suffer from far less severe disease than those qualifying as CLI in the initial 1991 consensus document. Furthermore, inclusion criteria of many recent interventional studies have even shifted further from the efforts of definition standardisation with objective criteria, by including patients as CLI based merely on Fontaine classification (stage III and IV) without haemodynamic criteria. The differences in the natural history of patients with CLI, including prognosis of the limb and the patient, are thus difficult to compare between studies in this context. Overall, CLI as defined by clinical and haemodynamic criteria remains a severe condition with poor prognosis, high medical costs and a major impact in terms of public health and patients' loss of functional capacity. The major progresses in best medical therapy of arterial disease and revascularisation procedures will certainly improve the outcome of CLI patients. In the future, an effort to apply a standardised definition with clinical and objective haemodynamic criteria will be needed to better demonstrate and compare the advances in management of these patients.
Resumo:
Ventricular assist devices (VADs) and total artificial hearts have been in development for the last 50 years. Since their inception, simulators of the circulation with different degrees of complexity have been produced to test these devices in vitro. Currently, a new path has been taken with the extensive efforts to develop paediatric VADs, which require totally different design constraints. This paper presents the manufacturing details of an economical simulator of the systemic paediatric circulation. This simulator allows the insertion of a paediatric VAD, includes a pumping ventricle, and is adjustable within the paediatric range. Rather than focusing on complexity and physiological simulation, this simulator is designed to be simple and practical for rapid device testing. The simulator was instrumented with medical sensors and data were acquired under different conditions with and without the new PediaFlowTM paediatric VAD. The VAD was run at different impeller speeds while simulator settings such as vascular resistance and stroke volume were varied. The hydraulic performance of the VAD under pulsatile conditions could be characterized and the magnetic suspension could be tested via manipulations such as cannula clamping. This compact mock loop has proven to be valuable throughout the PediaFlow development process and has the advantage that it is uncomplicated and can be manufactured cheaply. It can be produced by several research groups and the results of different VADs can then be compared easily.
Resumo:
Overwhelming evidence shows the quality of reporting of randomised controlled trials (RCTs) is not optimal. Without transparent reporting, readers cannot judge the reliability and validity of trial findings nor extract information for systematic reviews. Recent methodological analyses indicate that inadequate reporting and design are associated with biased estimates of treatment effects. Such systematic error is seriously damaging to RCTs, which are considered the gold standard for evaluating interventions because of their ability to minimise or avoid bias. A group of scientists and editors developed the CONSORT (Consolidated Standards of Reporting Trials) statement to improve the quality of reporting of RCTs. It was first published in 1996 and updated in 2001. The statement consists of a checklist and flow diagram that authors can use for reporting an RCT. Many leading medical journals and major international editorial groups have endorsed the CONSORT statement. The statement facilitates critical appraisal and interpretation of RCTs. During the 2001 CONSORT revision, it became clear that explanation and elaboration of the principles underlying the CONSORT statement would help investigators and others to write or appraise trial reports. A CONSORT explanation and elaboration article was published in 2001 alongside the 2001 version of the CONSORT statement. After an expert meeting in January 2007, the CONSORT statement has been further revised and is published as the CONSORT 2010 Statement. This update improves the wording and clarity of the previous checklist and incorporates recommendations related to topics that have only recently received recognition, such as selective outcome reporting bias. This explanatory and elaboration document-intended to enhance the use, understanding, and dissemination of the CONSORT statement-has also been extensively revised. It presents the meaning and rationale for each new and updated checklist item providing examples of good reporting and, where possible, references to relevant empirical studies. Several examples of flow diagrams are included. The CONSORT 2010 Statement, this revised explanatory and elaboration document, and the associated website (www.consort-statement.org) should be helpful resources to improve reporting of randomised trials.
Resumo:
The surgical treatment of liver tumours relies on precise localization of the lesions and detailed knowledge of the patient-specific vascular and biliary anatomy. Detailed three-dimensional (3D) anatomical information facilitates complete tumour removal while preserving a sufficient amount of functional liver tissue.