919 resultados para Mandibular advancement device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patterns of nest construction and nest site selection of two murid rodents of the Brazilian Atlantic rainforest were described. The animals were captured in an area of about 1.5 ha of primary forest, marked, equipped with a spool-and-line device and released at the capture point. The next day we followed the thread to find their nests. In total 11 nests of Nectomys squamipes (Brants, 1827) and 13 of Oryzomys intermedius (Leche, 1886) were found. They were all egg-shaped, about 15 cm long and 10 cm wide, without any apparent entrance and consisted of dry leaves and grass. The two species differed in the selection of nest sites. The nests of N. squamipes were close to streams and built inside decomposed fallen logs or using natural entrances between the soil and tangled roots or rocky crevices. Nests of O. intermedius were built under or inside fallen logs and inside aerial root systems of palms. The spool-and-line technique used here is useful to provide detailed information on several aspects of the ecology and natural history of small mammals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The objective of this study was to carry out a comparative evaluation of the mechanical resistance of 2 rigid internal fixation techniques for fractures of the mandibular condyle using miniplates.Materials and Methods: Fort), polyurethane resin replicas of human hemimandibles were used. The hemimandibles were sectioned to simulate a high subcondylar fracture and then stabilized with 2 fixing techniques using 2.0-mm system plates and screws. The fixation techniques were 2 separate 4-hole plates with 8 screws, and 2 overlaid 4-hole plates with 4 screws. Each system was submitted to load tests, with the application of the load in mediolateral and anteroposterior directions in an Instron 4411 universal assay machine (Instron, Norwood, MA).Results: Load values and peak displacement were measured. Means and standard deviations were evaluated by analysis of variance (P < .05) and Tukey tests, in which it was verified that the anteroposterior peak load value was affected by the arrangement of the plates on the models, although no differences were observed between the groups for the mediolateral peak load. The arrangement of the plates did not have any influence on peak displacement. Similarly, the final value of the mediolateral load was not affected by the arrangement of the plates on the model.Conclusion: The experimental model with 2 separate plates was statistically superior to the model with 2 overlaid plates only in relation to anteroposterior peak load. Despite showing superiority in mediolateral peak load and peak displacement, there was no statistical difference between the groups for these parameters. (C) 2009 American Association of Oral and Maxillofacial Surgeons

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to gather data on trauma etiology and mandibular fracture localization in patients who presented at the General Hospital of Nova Iguacu, Rio de Janeiro, Brazil. From March 2007 to December 2008, 95 patients with mandibular fracture were registered in a medical form, at the Bucomax-illofacial Surgery Department of the General Hospital of Nova Iguacu, Rio de Janeiro, Brazil. Concerning mandibular fracture etiology, 21.05% were caused by motorcycle accidents, followed by interpersonal violence without use of weapons (punches, kicks, bumps with the head, blows with the elbow, etc) (16.84%) and interpersonal violence with firearm (14.73%). It was found that 52.63% of the patients had a single fracture line. The most affected fracture area was the parasymphysis (26.02%), followed by the condyle (22.60%) and mandibular angle (18.49%). Concerning the injury area, 24.21% were directed to the mandibular symphysis, 22.17% of the patients did not remember the injury area, and 18.94% had multiple injuries. When the injury was directed to the symphysis, the result was more condyle fractures (11.64%), and injuries at the mandibular angle resulted in fractures at the angle itself (8.90%). The most common fracture cause was traffic accidents, mainly motorcycle accidents, and the most affected areas were the parasymphysis and the condyle. The mandible isolated fractures occurred in half of the cases. Motorcycle accidents resulted in more fractures in the parasymphysis area, and when the symphysis area is affected by injuries, the result is a higher percentage in condyle fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to test a device developed to improve the functionality, accuracy and precision of the original technique for sweating rate measurements proposed by Schleger and Turner [Schleger AV, Turner HG (1965) Aust J Agric Res 16:92-106]. A device was built for this purpose and tested against the original Schleger and Turner technique. Testing was performed by measuring sweating rates in an experiment involving six Mertolenga heifers subjected to four different thermal levels in a climatic chamber. The device exhibited no functional problems and the results obtained with its use were more consistent than with the Schleger and Turner technique. There was no difference in the reproducibility of the two techniques (same accuracy), but measurements performed with the new device had lower repeatability, corresponding to lower variability and, consequently, to higher precision. When utilizing this device, there is no need for physical contact between the operator and the animal to maintain the filter paper discs in position. This has important advantages: the animals stay quieter, and several animals can be evaluated simultaneously. This is a major advantage because it allows more measurements to be taken in a given period of time, increasing the precision of the observations and diminishing the error associated with temporal hiatus (e.g., the solar angle during field studies). The new device has higher functional versatility when taking measurements in large-scale studies (many animals) under field conditions. The results obtained in this study suggest that the technique using the device presented here could represent an advantageous alternative to the original technique described by Schleger and Turner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the integration of implants installed using a surgical guide in augmented sites with autologous bone or deproteinized bovine bone mineral (DBBM) blocks, concomitantly with a collagen membrane.Material and methods: Mandibular molars were extracted bilaterally in six Labrador dogs, the buccal bony wall was removed, and a box-shaped defect was created. After 3 months, flaps were elevated, a bony graft was harvested from the ascending ramus, and secured to the lateral wall of the defect by means of screws. In the left mandibular side, a DBBM block was fixed into the defect. A resorbable membrane was applied at both sides, and the flaps were sutured. After 3 months, flaps were elevated, and a customized device was used as surgical guide to prepare the recipient sites in the interface between grafts and parent bone. One implant was installed in each side of the mandible. After 3 months, biopsies were harvested, and ground sections were prepared for histologic evaluation.Results: One autologous bone block graft was lost before implant installation. The width of the alveolar crest at the test sites (DBBM) was 5.4 +/- 1.2 mm before, 9.4 +/- 1.2 mm immediately after grafting, and 9.3 +/- 1 mm at implant installation. At the control sites (autologous bone), the corresponding values were: 5.2 +/- 1, 9 +/- 1.2, and 8.7 +/- 0.9 mm, respectively. All implants installed were available for histologic evaluation (n = 5). The autologous bone grafts, rich in vessels and cells, were integrated in the parent bone, and only little non-vital bone was found. The BIC% was 56.7 +/- 15.6% and 54.2 +/- 13.2% at the buccal and lingual aspects, respectively. At the test sites, the DBBM appeared to be embedded into connective tissue, and very little newly formed bone was encountered within the grafts. The BIC% was 5.8 +/- 12.3% and 51.3 +/- 14.2% at the buccal and lingual aspects, respectively.Conclusions: Autologous bone blocks used to augment the alveolar bony crest horizontally allowed the complete osseointegration of implants installed after 3 months of healing. However, similar blocks of DBBM did not promote osseointegration, although the installed implants were stable owing to the osseointegration in the sites of the parent bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Described is a case of squamous-cell carcinoma arising in a residual cyst in a 60-year-old edentulous woman. The clinical and radiographic diagnosis was residual cyst, and the treatment employed was conservative surgical enucleation. The cause of these changes is unknown. Theoretically, the inflammatory reaction may have been a predisposing factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermoluminescent dosimeters were used to measure radiation doses at craniofacial sites in a tissue-equivalent phantom during film-based multidirectional tomography with the Tomax Ultrascan (Incubation Industries, Ivyland, Pa.) and during computed tomography with the Elscint Excel 2400 (Elscint Corp., Tel Aviv, Israel). Mean absorbed doses for presurgical mandibular and maxillary canine and molar implant assessments were converted to equivalent doses, which were then multipied by published weighting factors and summed to give effective doses. The computed tomgraphy device consistently delivered higher doses than the Tomax Ultrascan to all anatomic locations; the differences were most pronounced when only one or two implant sites were evaluated. The reasons for the dose disparities are considered both anatomically and procedurally. A survey of examination cost revealed film-based multidirectional tomography to be less expensive than computed tomography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Constrictotermes rupestris, new species, is described from central Brazil, with illustrations of the imago, soldier, worker head, worker mandibles, worker mandibular gland, and nest. The new species lives in a dry forest, on rocky terrain, building its nest always on rocks. In the colonies examined, all castes showed a striking reddish coloration due to something accumulated in the fat tissues. Inquilinitermes microcerus was present in most examined nests. The worker of C. rupestris has an enlarged mandibular gland. Workers also show an aggressive behavior, which suggests that the mandibular glands may produce defensive secretions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The superior belly of the omohyoid muscle and the anterior belly of the digastric muscle, were studied electromyographically in 20 young volunteers. For each muscle, 1 pair of monopolar electrodes was employed. One was a surface electrode and the other a needle electrode, which was inserted in the belly of the muscle. The surface electrode was placed 1 cm apart from the needle electrode. The most marked action of both muscles was on the movement of lowering the mandible. They also act in those movements for the performance of which they have associated a component of lowering the jaw, propulsion, laterality to the right and the left and retrusion. They are not active in the resting position and during jaw movements of elevation, extrusion and protrusion. Both muscles are active most of the time, simultaneously, but it is not possible to demonstrate that there is a synchronism between their actions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Standardization of measurements for marginal fit of castings is critical. This study describes the fabrication of a device that allowed fixation of specimens on a Toolmakers microscope with identical conditions according to tri-dimensional positioning of specimens, measuring location, and seating force. The device also allows mapping of the marginal discrepancies on the entire marginal perimeter of the tooth preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present investigation we analyzed both histology and area of secretory cells from workers, virgin and physogastric queen mandibular glands of Melipona bicolor bicolor Lepeletier. The histological differences observed include the number of vacuoles present in the cell cytoplasm and the quantity and distribution of the secretion. The morphometry results demonstrated the occurrence of significative differences in the cell area values that were related to the secretory cell activity level, which is higher in the physogastric queens. Worker and queen glands have histological patterns quite similar, but the morphometric data indicated cast-specific differences, as well as differences between the queens, which were related to the posture activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this investigation was to evaluate the dentoalveolar and skeletal cephalometric changes produced by the Fränkel appliance in individuals with a Class II, division 1 malocclusion. Lateral cephalograms of 44 patients of both sexes were divided in two groups of 22 each. The control group was comprised of untreated Class II children with an initial mean age of eight years and seven months who were followed without treatment for a period of 13 months. The Fränkel group had an initial mean age of nine years and was treated for a mean period of 17 months. Lateral cephalometric headfilms of each patient were obtained at the beginning and end of treatment. The Fränkel appliance produced no significant changes in maxillary growth during the evaluation period, while a statistically significant increase in mandibular length was observed. The maxillomandibular relationship improved mostly because of an increase in mandibular length. In addition, there were no statistically significant differences in the craniofacial growth direction between the Fränkel and the control group, both showing a slight downward rotation of the palatal plane. The Fränkel appliance produced a labial tipping of the lower incisors and a lingual inclination of the upper incisors as well as a significant increase in mandibular posterior dentoalveolar height. It was concluded that the main effects of the Fränkel appliance during this time period were mostly dentoalveolar with a smaller but significant skeletal mandibular effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ectal mandibular gland (EMG) of wasps is homologous to the mandibular gland of ants and bees. This gland belongs to salivary system and its function stile unknown. The EMG of Polistes versicolor showed histological and ultramorphological features similar to that founded in ants and others wasps. This gland is constituted by a secretory region and a reservoir. The secretory region contains individual secretory cells that showed several nucleoli. The reservoir has a club shape and is connected to each mandible, by a duct that opens on its external side, which there are cuticular projections. The EMG of males is smaller than those of females. Our results suggested that the EMG secrete volatiles compounds that are liberated when the mandibles still open.