934 resultados para Low resolution brain tomography (LORETA)
Resumo:
We determined the effect of the opiate receptor antagonist naloxone on aggression, emotion, feeder control, and eating behavior in high and low aggression female pigeons maintained at 80% of their normal weight and exposed to food competition interactions. Pigeons were divided into pairs by previously ranked high aggression (total time spent in offensive aggression exceeding 60 s/5 min; N = 6 pairs) and low aggression females (time spent in offensive aggression less than 10 s/5 min; N = 6 pairs). A pigeon in each pair received an sc dose of naloxone (1 mg kg-1 ml saline-1) and the other animal received the vehicle. Trials (10 min) were performed 30 min after the naloxone/vehicle administration. The naloxone group of high aggression pigeons showed lower scores of total time spent in offensive aggression (control: 98.6 ± 12.0; naloxone: 46.8 ± 6.6 s; P < 0.05) and higher scores of time spent in emotional responses (control: 3.5 ± 0.6; naloxone: 10.8 ± 2.4 s; P < 0.05) than controls. The other behaviors scored, feeder control and eating behavior, were not affected in this group. The naloxone group of low aggression pigeons, however, showed higher scores of offensive aggression than their controls (5.3 ± 1.3; naloxone: 28.7 ± 8.0 s; P < 0.05). The present results suggest that opiate receptor mechanisms are implicated in offensive aggression responses in high and low aggression pigeons. However, as reported for brain 5-hydroxytryptamine manipulation and GABA-A-benzodiazepine receptor manipulation, the effect of the opiate receptor antagonist on food competition aggression in pigeons was related to their pretreatment level of aggression.
Resumo:
A gravimetric method was evaluated as a simple, sensitive, reproducible, low-cost alternative to quantify the extent of brain infarct after occlusion of the medial cerebral artery in rats. In ether-anesthetized rats, the left medial cerebral artery was occluded for 1, 1.5 or 2 h by inserting a 4-0 nylon monofilament suture into the internal carotid artery. Twenty-four hours later, the brains were processed for histochemical triphenyltetrazolium chloride (TTC) staining and quantitation of the schemic infarct. In each TTC-stained brain section, the ischemic tissue was dissected with a scalpel and fixed in 10% formalin at 0ºC until its total mass could be estimated. The mass (mg) of the ischemic tissue was weighed on an analytical balance and compared to its volume (mm³), estimated either by plethysmometry using platinum electrodes or by computer-assisted image analysis. Infarct size as measured by the weighing method (mg), and reported as a percent (%) of the affected (left) hemisphere, correlated closely with volume (mm³, also reported as %) estimated by computerized image analysis (r = 0.88; P < 0.001; N = 10) or by plethysmography (r = 0.97-0.98; P < 0.0001; N = 41). This degree of correlation was maintained between different experimenters. The method was also sensitive for detecting the effect of different ischemia durations on infarct size (P < 0.005; N = 23), and the effect of drug treatments in reducing the extent of brain damage (P < 0.005; N = 24). The data suggest that, in addition to being simple and low cost, the weighing method is a reliable alternative for quantifying brain infarct in animal models of stroke.
Resumo:
An assumption commonly made in the study of visual perception is that the lower the contrast threshold for a given stimulus, the more sensitive and selective will be the mechanism that processes it. On the basis of this consideration, we investigated contrast thresholds for two classes of stimuli: sine-wave gratings and radial frequency stimuli (i.e., j0 targets or stimuli modulated by spherical Bessel functions). Employing a suprathreshold summation method, we measured the selectivity of spatial and radial frequency filters using either sine-wave gratings or j0 target contrast profiles at either 1 or 4 cycles per degree of visual angle (cpd), as the test frequencies. Thus, in a forced-choice trial, observers chose between a background spatial (or radial) frequency alone and the given background stimulus plus the test frequency (1 or 4 cpd sine-wave grating or radial frequency). Contrary to our expectations, the results showed elevated thresholds (i.e., inhibition) for sine-wave gratings and decreased thresholds (i.e., summation) for radial frequencies when background and test frequencies were identical. This was true for both 1- and 4-cpd test frequencies. This finding suggests that sine-wave gratings and radial frequency stimuli are processed by different quasi-linear systems, one working at low luminance and contrast level (sine-wave gratings) and the other at high luminance and contrast levels (radial frequency stimuli). We think that this interpretation is consistent with distinct foveal only and foveal-parafoveal mechanisms involving striate and/or other higher visual areas (i.e., V2 and V4).
Resumo:
Single-photon emission computed tomography (SPECT) is a non-invasive imaging technique, which provides information reporting the functional states of tissues. SPECT imaging has been used as a diagnostic tool in several human disorders and can be used in animal models of diseases for physiopathological, genomic and drug discovery studies. However, most of the experimental models used in research involve rodents, which are at least one order of magnitude smaller in linear dimensions than man. Consequently, images of targets obtained with conventional gamma-cameras and collimators have poor spatial resolution and statistical quality. We review the methodological approaches developed in recent years in order to obtain images of small targets with good spatial resolution and sensitivity. Multipinhole, coded mask- and slit-based collimators are presented as alternative approaches to improve image quality. In combination with appropriate decoding algorithms, these collimators permit a significant reduction of the time needed to register the projections used to make 3-D representations of the volumetric distribution of target’s radiotracers. Simultaneously, they can be used to minimize artifacts and blurring arising when single pinhole collimators are used. Representation images are presented, which illustrate the use of these collimators. We also comment on the use of coded masks to attain tomographic resolution with a single projection, as discussed by some investigators since their introduction to obtain near-field images. We conclude this review by showing that the use of appropriate hardware and software tools adapted to conventional gamma-cameras can be of great help in obtaining relevant functional information in experiments using small animals.
Resumo:
Computed tomography (CT) images are routinely used to assess ischemic brain stroke in the acute phase. They can provide important clues about whether to treat the patient by thrombolysis with tissue plasminogen activator. However, in the acute phase, the lesions may be difficult to detect in the images using standard visual analysis. The objective of the present study was to determine if texture analysis techniques applied to CT images of stroke patients could differentiate between normal tissue and affected areas that usually go unperceived under visual analysis. We performed a pilot study in which texture analysis, based on the gray level co-occurrence matrix, was applied to the CT brain images of 5 patients and of 5 control subjects and the results were compared by discriminant analysis. Thirteen regions of interest, regarding areas that may be potentially affected by ischemic stroke, were selected for calculation of texture parameters. All regions of interest for all subjects were classified as lesional or non-lesional tissue by an expert neuroradiologist. Visual assessment of the discriminant analysis graphs showed differences in the values of texture parameters between patients and controls, and also between texture parameters for lesional and non-lesional tissue of the patients. This suggests that texture analysis can indeed be a useful tool to help neurologists in the early assessment of ischemic stroke and quantification of the extent of the affected areas.
Resumo:
The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target’s three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology.
Resumo:
The physiological mechanisms involved in isoproterenol (ISO)-induced chronic heart failure (CHF) are not fully understood. In this study, we investigated local changes in cardiac aldosterone and its synthase in rats with ISO-induced CHF, and evaluated the effects of treatment with recombinant human brain natriuretic peptide (rhBNP). Sprague-Dawley rats were divided into 4 different groups. Fifty rats received subcutaneous ISO injections to induce CHF and the control group (n=10) received equal volumes of saline. After establishing the rat model, 9 CHF rats received no further treatment, rats in the low-dose group (n=8) received 22.5 μg/kg rhBNP and those in the high-dose group (n=8) received 45 μg/kg rhBNP daily for 1 month. Cardiac function was assessed by echocardiographic and hemodynamic analysis. Collagen volume fraction (CVF) was determined. Plasma and myocardial aldosterone concentrations were determined using radioimmunoassay. Myocardial aldosterone synthase (CYP11B2) was detected by quantitative real-time PCR. Cardiac function was significantly lower in the CHF group than in the control group (P<0.01), whereas CVF, plasma and myocardial aldosterone, and CYP11B2 transcription were significantly higher than in the control group (P<0.05). Low and high doses of rhBNP significantly improved hemodynamics (P<0.01) and cardiac function (P<0.05) and reduced CVF, plasma and myocardial aldosterone, and CYP11B2 transcription (P<0.05). There were no significant differences between the rhBNP dose groups (P>0.05). Elevated cardiac aldosterone and upregulation of aldosterone synthase expression were detected in rats with ISO-induced CHF. Administration of rhBNP improved hemodynamics and ventricular remodeling and reduced myocardial fibrosis, possibly by downregulating CYP11B2 transcription and reducing myocardial aldosterone synthesis.
Resumo:
Obesity is one of the key challenges to health care system worldwide and its prevalence is estimated to rise to pandemic proportions. Numerous adverse health effects follow with increasing body weight, including increased risk of hypertension, diabetes, hypercholesterolemia, musculoskeletal pain and cancer. Current evidence suggests that obesity is associated with altered cerebral reward circuit functioning and decreased inhibitory control over appetitive food cues. Furthermore, obesity causes adverse shifts in metabolism and loss of structural integrity within the brain. Prior cross-sectional studies do not allow delineating which of these cerebral changes are recoverable after weight loss. We compared morbidly obese subjects with healthy controls to unravel brain changes associated with obesity. Bariatric surgery was used as an intervention to study which cerebral changes are recoverable after weight loss. In Study I we employed functional magnetic resonance imaging (fMRI) to detect the brain basis of volitional appetite control and its alterations in obesity. In Studies II-III we used diffusion tensor imaging (DTI) and voxel-based morphometry (VBM) to quantify the effects of obesity and the effects of weight loss on structural integrity of the brain. In study IV we used positron emission tomography (PET) with [18F]-FDG in fasting state and during euglycemic hyperinsulinemia to quantify effects of obesity and weight loss on brain glucose uptake. The fMRI experiment revealed that a fronto-parietal network is involved in volitional appetite control. Obese subjects had lower medial frontal and dorsal striatal brain activity during cognitive appetite control and increased functional connectivity within the appetite control circuit. Obese subjects had initially lower grey matter and white matter densities than healthy controls in VBM analysis and loss of integrity in white matter tracts as measured by DTI. They also had initially elevated glucose metabolism under insulin stimulation but not in fasting state. After the weight loss following bariatric surgery, obese individuals’ brain volumes recovered and the insulin-induced increase in glucose metabolism was attenuated. In conclusion, obesity is associated with altered brain function, coupled with loss of structural integrity and elevated glucose metabolism, which are likely signs of adverse health effects to the brain. These changes are reversed by weight loss after bariatric surgery, implicating that weight loss has a causal role on these adverse cerebral changes. Altogether these findings suggest that weight loss also promotes brain health.Key words: brain, obesity, bariatric surgery, appetite control, structural magnetic resonance
Resumo:
University of Turku, Faculty of Medicine, Department of Cardiology and Cardiovascular Medicine, Doctoral Programme of Clinical Investigation, Heart Center, Turku University Hospital, Turku, Finland Division of Internal Medicine, Department of Cardiology, Seinäjoki Central Hospital, Seinäjoki, Finland Heart Center, Satakunta Central Hospital, Pori, Finland Annales Universitatis Turkuensis Painosalama Oy, Turku, Finland 2015 Antithrombotic therapy during and after coronary procedures always entails the challenging establishment of a balance between bleeding and thrombotic complications. It has been generally recommended to patients on long-term warfarin therapy to discontinue warfarin a few days prior to elective coronary angiography or intervention to prevent bleeding complications. Bridging therapy with heparin is recommended for patients at an increased risk of thromboembolism who require the interruption of anticoagulation for elective surgery or an invasive procedure. In study I, consecutive patients on warfarin therapy referred for diagnostic coronary angiography were compared to control patients with a similar disease presentation without warfarin. The strategy of performing coronary angiography during uninterrupted therapeutic warfarin anticoagulation appeared to be a relatively safe alternative to bridging therapy, if the international normalized ratio level was not on a supratherapeutic level. In-stent restenosis remains an important reason for failure of long-term success after a percutaneous coronary intervention (PCI). Drug-eluting stents (DES) reduce the problem of restenosis inherent to bare metal stents (BMS). However, a longer delay in arterial healing may extend the risk of stent thrombosis (ST) far beyond 30 days after the DES implantation. Early discontinuation of antiplatelet therapy has been the most important predisposing factor for ST. In study II, patients on long-term oral anticoagulant (OAC) underwent DES or BMS stenting with a median of 3.5 years’follow-up. The selective use of DESs with a short triple therapy seemed to be safe in OAC patients, since late STs were rare even without long clopidogrel treatment. Major bleeding and cardiac events were common in this patient group irrespective of stent type. In order to help to predict the bleeding risk in patients on OAC, several different bleeding risk scorings have been developed. Risk scoring systems have also been used also in the setting of patients undergoing a PCI. In study III, the predictive value of an outpatient bleeding risk index (OBRI) to identify patients at high risk of bleeding was analysed. The bleeding risk seemed not to modify periprocedural or long-term treatment choices in patients on OAC after a percutaneous coronary intervention. Patients with a high OBRI often had major bleeding episodes, and the OBRI may be suitable for risk evaluation in this patient group. Optical coherence tomography (OCT) is a novel technology for imaging intravascular coronary arteries. OCT is a light-based imaging modality that enables a 12–18 µm tissue axial resolution to visualize plaques in the vessel, possible dissections and thrombi as well as, stent strut appositions and coverage, and to measure the vessel lumen and lesions. In study IV, 30 days after titanium-nitride-oxide (TITANOX)-coated stent implantation, the binary stent strut coverage was satisfactory and the prevalence of malapposed struts was low as evaluated by OCT. Long-term clinical events in patients treated with (TITANOX)-coated bio-active stents (BAS) and paclitaxel-eluting stents (PES) in routine clinical practice were examined in study V. At the 3-year follow-up, BAS resulted in better long-term outcome when compared with PES with an infrequent need for target vessel revascularization. Keywords: anticoagulation, restenosis, thrombosis, bleeding, optical coherence tomography, titanium
Resumo:
Positron emission tomography imaging has both academic and applied uses in revealing the distribution and density of different molecular targets in the central nervous system. Following the significant progress made with the dopamine D2 receptor, advances have been made in developing PET tracers to allow analysis of receptor occupancy of many other receptor types as well as evaluating changes in endogenous synaptic transmitter concentrations of transmitters e.g. serotonin and noradrenaline. Noradrenergic receptors are divided into α1-, α2- and β-adrenoceptor subfamilies, in humans each of which is composed of three receptor subtypes. The α2-adrenoceptors have an important presynaptic auto-inhibitory function on noradrenaline release but they also have postsynaptic roles in modulating the release of other neurotransmitters, such as serotonin and dopamine. One of the subtypes, the α2C-adrenoceptor, has been detected at distinct locations in the central nervous system, most notably the dorsal striatum. Several serious neurological conditions causing dementia, Alzheimer’s disease and Parkinson’s disease have been linked to disturbed noradrenergic signaling. Furthermore, altered noradrenergic signaling has also been implicated in conditions like ADHD, depression, anxiety and schizophrenia. In order to benefit future research into these central nervous system disorders as well as being useful in the clinical development of drugs affecting brain noradrenergic neurotransmission, validation work of a novel tracer for positron emission tomography studies in humans was performed. Altogether 85 PET imaging experiments were performed during four separate clinical trials. The repeatability of [11C]ORM-13070 binding was tested in healthy individuals, followed by a study to evaluate the dose-dependent displacement of [11C]ORM-13070 from α2C-adrenoceptors by a competing ligand, and the final two studies examined the sensitivity of [11C]ORM-13070 binding to reflect changes in endogenous noradrenaline levels. The repeatability of [11C]ORM-13070 binding was very high. The binding properties of the tracer allowed for a reliable estimation of α2C-AR occupancy by using the reference tissue ratio method with low test-retest variability. [11C]ORM-13070 was dose-dependently displaced from its specific binding sites by the subtype-nonselective α2-adrenoceptor antagonist atipamezole, and thus it proved suitable for use in clinical drug development of novel α2C-adrenoceptor ligands e.g. to determine the best doses and dosing intervals for clinical trials. Convincing experimental evidence was gained to support the suitability of [11C]ORM-13070 for detecting an increase in endogenous synaptic noradrenaline in the human brain. Tracer binding in the thalamus tended to increase in accordance with reduced activity of noradrenergic projections from the locus coeruleus, although statistical significance was not reached. Thus, the investigation was unable to fully validate [11C]ORM-13070 for the detection of pharmacologically evoked reductions in noradrenaline levels.
Resumo:
A Czerny Mount double monochromator is used to measure Raman scattered radiation near 90" from a crystalline, Silicon sample. Incident light is provided by a mixed gas Kr-Ar laser, operating at 5145 A. The double monochromator is calibrated to true wavelength by comparison of Kr and Ar emission Une positions (A) to grating position (A) display [1]. The relationship was found to be hnear and can be described by, y = 1.219873a; - 1209.32, (1) where y is true wavelength (A) and xis grating position display (A). The Raman emission spectra are collected via C"*""*" encoded software, which displays a mV signal from a Photodetector and allows stepping control of the gratings via an A/D interface. [2] The software collection parameters, detector temperature and optics are optimised to yield the best quality spectra. The inclusion of a cryostat allows for temperatmre dependent capabihty ranging from 4 K to w 350 K. Silicon Stokes temperatm-e dependent Raman spectra, generally show agreement with Uterature results [3] in their frequency haxdening, FWHM reduction and intensity increase as temperature is reduced. Tests reveal that a re-alignment of the double monochromator is necessary before spectral resolution can approach literature standard. This has not yet been carried out due to time constraints.
Conventional and Reciprocal Approaches to the Forward and Inverse Problems of Electroencephalography
Resumo:
Le problème inverse en électroencéphalographie (EEG) est la localisation de sources de courant dans le cerveau utilisant les potentiels de surface sur le cuir chevelu générés par ces sources. Une solution inverse implique typiquement de multiples calculs de potentiels de surface sur le cuir chevelu, soit le problème direct en EEG. Pour résoudre le problème direct, des modèles sont requis à la fois pour la configuration de source sous-jacente, soit le modèle de source, et pour les tissues environnants, soit le modèle de la tête. Cette thèse traite deux approches bien distinctes pour la résolution du problème direct et inverse en EEG en utilisant la méthode des éléments de frontières (BEM): l’approche conventionnelle et l’approche réciproque. L’approche conventionnelle pour le problème direct comporte le calcul des potentiels de surface en partant de sources de courant dipolaires. D’un autre côté, l’approche réciproque détermine d’abord le champ électrique aux sites des sources dipolaires quand les électrodes de surfaces sont utilisées pour injecter et retirer un courant unitaire. Le produit scalaire de ce champ électrique avec les sources dipolaires donne ensuite les potentiels de surface. L’approche réciproque promet un nombre d’avantages par rapport à l’approche conventionnelle dont la possibilité d’augmenter la précision des potentiels de surface et de réduire les exigences informatiques pour les solutions inverses. Dans cette thèse, les équations BEM pour les approches conventionnelle et réciproque sont développées en utilisant une formulation courante, la méthode des résidus pondérés. La réalisation numérique des deux approches pour le problème direct est décrite pour un seul modèle de source dipolaire. Un modèle de tête de trois sphères concentriques pour lequel des solutions analytiques sont disponibles est utilisé. Les potentiels de surfaces sont calculés aux centroïdes ou aux sommets des éléments de discrétisation BEM utilisés. La performance des approches conventionnelle et réciproque pour le problème direct est évaluée pour des dipôles radiaux et tangentiels d’excentricité variable et deux valeurs très différentes pour la conductivité du crâne. On détermine ensuite si les avantages potentiels de l’approche réciproquesuggérés par les simulations du problème direct peuvent êtres exploités pour donner des solutions inverses plus précises. Des solutions inverses à un seul dipôle sont obtenues en utilisant la minimisation par méthode du simplexe pour à la fois l’approche conventionnelle et réciproque, chacun avec des versions aux centroïdes et aux sommets. Encore une fois, les simulations numériques sont effectuées sur un modèle à trois sphères concentriques pour des dipôles radiaux et tangentiels d’excentricité variable. La précision des solutions inverses des deux approches est comparée pour les deux conductivités différentes du crâne, et leurs sensibilités relatives aux erreurs de conductivité du crâne et au bruit sont évaluées. Tandis que l’approche conventionnelle aux sommets donne les solutions directes les plus précises pour une conductivité du crâne supposément plus réaliste, les deux approches, conventionnelle et réciproque, produisent de grandes erreurs dans les potentiels du cuir chevelu pour des dipôles très excentriques. Les approches réciproques produisent le moins de variations en précision des solutions directes pour différentes valeurs de conductivité du crâne. En termes de solutions inverses pour un seul dipôle, les approches conventionnelle et réciproque sont de précision semblable. Les erreurs de localisation sont petites, même pour des dipôles très excentriques qui produisent des grandes erreurs dans les potentiels du cuir chevelu, à cause de la nature non linéaire des solutions inverses pour un dipôle. Les deux approches se sont démontrées également robustes aux erreurs de conductivité du crâne quand du bruit est présent. Finalement, un modèle plus réaliste de la tête est obtenu en utilisant des images par resonace magnétique (IRM) à partir desquelles les surfaces du cuir chevelu, du crâne et du cerveau/liquide céphalorachidien (LCR) sont extraites. Les deux approches sont validées sur ce type de modèle en utilisant des véritables potentiels évoqués somatosensoriels enregistrés à la suite de stimulation du nerf médian chez des sujets sains. La précision des solutions inverses pour les approches conventionnelle et réciproque et leurs variantes, en les comparant à des sites anatomiques connus sur IRM, est encore une fois évaluée pour les deux conductivités différentes du crâne. Leurs avantages et inconvénients incluant leurs exigences informatiques sont également évalués. Encore une fois, les approches conventionnelle et réciproque produisent des petites erreurs de position dipolaire. En effet, les erreurs de position pour des solutions inverses à un seul dipôle sont robustes de manière inhérente au manque de précision dans les solutions directes, mais dépendent de l’activité superposée d’autres sources neurales. Contrairement aux attentes, les approches réciproques n’améliorent pas la précision des positions dipolaires comparativement aux approches conventionnelles. Cependant, des exigences informatiques réduites en temps et en espace sont les avantages principaux des approches réciproques. Ce type de localisation est potentiellement utile dans la planification d’interventions neurochirurgicales, par exemple, chez des patients souffrant d’épilepsie focale réfractaire qui ont souvent déjà fait un EEG et IRM.
Resumo:
Les troubles reliés à la dépression, l’épuisement professionnel et l’anxiété sont de plus en plus répandus dans notre société moderne. La consommation croissante d’antidépresseurs dans les différents pays du monde est responsable de la récente détection de résidus à l’état de traces dans les rejets urbains municipaux. Ainsi, ces substances dites « émergentes » qui possèdent une activité pharmacologique destinée à la régulation de certains neurotransmetteurs dans le cerveau suscitent maintenant de nombreuses inquiétudes de la part de la communauté scientifique. L’objectif principal de ce projet de doctorat a été de mieux comprendre le devenir de plusieurs classes d’antidépresseurs présents dans diverses matrices environnementales (i.e. eaux de surfaces, eaux usées, boues de traitement, tissus biologiques) en développant de nouvelles méthodes analytiques fiables capables de les détecter, quantifier et confirmer par chromatographie liquide à haute performance couplée à la spectrométrie de masse en tandem (LC-QqQMS, LC-QqToFMS). Une première étude complétée à la station d’épuration de la ville de Montréal a permis de confirmer la présence de six antidépresseurs et quatre métabolites N-desmethyl dans les affluents (2 - 330 ng L-1). Pour ce traitement primaire (physico-chimique), de faibles taux d’enlèvement (≤ 15%) ont été obtenus. Des concentrations d’antidépresseurs atteignant près de 100 ng L-1 ont également été détectées dans le fleuve St-Laurent à 0.5 km du point de rejet de la station d’épuration. Une seconde étude menée à la même station a permis l’extraction sélective d’antidépresseurs dans trois tissus (i.e. foie, cerveau et filet) de truites mouchetées juvéniles exposées à différentes concentrations d’effluent dilué traité et non-traité à l’ozone. Un certain potentiel de bioaccumulation dans les tissus (0.08-10 ng g-1) a été observé pour les spécimens exposés à l’effluent non-traité (20% v/v) avec distribution majoritaire dans le foie et le cerveau. Une intéressante corrélation a été établie entre les concentrations de trois antidépresseurs dans le cerveau et l’activité d’un biomarqueur d’exposition (i.e. pompe N/K ATPase impliquée dans la régulation de la sérotonine) mesurée à partir de synaptosomes de truites exposées aux effluents. Une investigation de l’efficacité de plusieurs stations d’épuration canadiennes opérant différents types de traitements a permis de constater que les traitements secondaires (biologiques) étaient plus performants que ceux primaires (physico-chimiques) pour enlever les antidépresseurs (taux moyen d’enlèvement : 30%). Les teneurs les plus élevées dans les boues traitées (biosolides) ont été obtenues avec le citalopram (1033 ng g-1), la venlafaxine (833 ng g-1) et l’amitriptyline (78 ng g-1). Des coefficients de sorption expérimentaux (Kd) calculés pour chacun des antidépresseurs ont permis d’estimer une grande sorption des composés sertraline, desméthylsertraline, paroxetine et fluoxetine sur les solides (log Kd > 4). Finalement, un excellent taux d’enlèvement moyen de 88% a été obtenu après ozonation (5 mg L-1) d’un effluent primaire. Toutefois, la caractérisation de nouveaux sous-produits N-oxyde (venlafaxine, desmethylvenlafaxine) par spectrométrie de masse à haute résolution (LC-QqToFMS) dans l’effluent traité à l’ozone a mis en lumière la possibilité de formation de multiples composés polaires de toxicité inconnue.
Resumo:
Les stimuli naturels projetés sur nos rétines nous fournissent de l’information visuelle riche. Cette information varie le long de propriétés de « bas niveau » telles que la luminance, le contraste, et les fréquences spatiales. Alors qu’une partie de cette information atteint notre conscience, une autre partie est traitée dans le cerveau sans que nous en soyons conscients. Les propriétés de l’information influençant l’activité cérébrale et le comportement de manière consciente versus non-consciente demeurent toutefois peu connues. Cette question a été examinée dans les deux derniers articles de la présente thèse, en exploitant les techniques psychophysiques développées dans les deux premiers articles. Le premier article présente la boîte à outils SHINE (spectrum, histogram, and intensity normalization and equalization), développée afin de permettre le contrôle des propriétés de bas niveau de l'image dans MATLAB. Le deuxième article décrit et valide la technique dite des bulles fréquentielles, qui a été utilisée tout au long des études de cette thèse pour révéler les fréquences spatiales utilisées dans diverses tâches de perception des visages. Cette technique offre les avantages d’une haute résolution au niveau des fréquences spatiales ainsi que d’un faible biais expérimental. Le troisième et le quatrième article portent sur le traitement des fréquences spatiales en fonction de la conscience. Dans le premier cas, la méthode des bulles fréquentielles a été utilisée avec l'amorçage par répétition masquée dans le but d’identifier les fréquences spatiales corrélées avec les réponses comportementales des observateurs lors de la perception du genre de visages présentés de façon consciente versus non-consciente. Les résultats montrent que les mêmes fréquences spatiales influencent de façon significative les temps de réponse dans les deux conditions de conscience, mais dans des sens opposés. Dans le dernier article, la méthode des bulles fréquentielles a été combinée à des enregistrements intracrâniens et au Continuous Flash Suppression (Tsuchiya & Koch, 2005), dans le but de cartographier les fréquences spatiales qui modulent l'activation de structures spécifiques du cerveau (l'insula et l'amygdale) lors de la perception consciente versus non-consciente des expressions faciales émotionnelles. Dans les deux régions, les résultats montrent que la perception non-consciente s'effectue plus rapidement et s’appuie davantage sur les basses fréquences spatiales que la perception consciente. La contribution de cette thèse est donc double. D’une part, des contributions méthodologiques à la recherche en perception visuelle sont apportées par l'introduction de la boîte à outils SHINE ainsi que de la technique des bulles fréquentielles. D’autre part, des indications sur les « corrélats de la conscience » sont fournies à l’aide de deux approches différentes.
Resumo:
The principal cause of mortality in patients with acute liver failure (ALF) is brain herniation resulting from intracranial hypertension caused by a progressive increase of brain water. In the present study, ex vivo high-resolution 1H-NMR spectroscopy was used to investigate the effects of ALF, with or without superimposed hypothermia, on brain organic osmolyte concentrations in relation to the severity of encephalopathy and brain edema in rats with ALF due to hepatic devascularization. In normothermic ALF rats, glutamine concentrations in frontal cortex increased more than fourfold at precoma stages, i.e. prior to the onset of severe encephalopathy, but showed no further increase at coma stages. In parallel with glutamine accumulation, the brain organic osmolytes myo-inositol and taurine were significantly decreased in frontal cortex to 63\% and 67\% of control values, respectively, at precoma stages (p<0.01), and to 58\% and 67\%, respectively, at coma stages of encephalopathy (p<0.01). Hypothermia, which prevented brain edema and encephalopathy in ALF rats, significantly attenuated the depletion of myo-inositol and taurine. Brain glutamine concentrations, on the other hand, did not respond to hypothermia. These findings demonstrate that experimental ALF results in selective changes in brain organic osmolytes as a function of the degree of encephalopathy which are associated with brain edema, and provides a further rationale for the continued use of hypothermia in the management of this condition.