930 resultados para Lab-On-A-Chip Devices


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An analytical theory to describe the combined effects of the epitaxial layer thickness and the ohmic contact on the noise properties of Schottky barrier diodes is presented. The theory, which provides information on both the local and the global noise properties, takes into account the finite size of the epitaxial layer and the effects of the back ohmic contact, and applies to the whole range of applied bias. It is shown that by scaling down the epitaxial layer thickness, the current regime in which the noise temperature displays a shot-noise-like behavior increases at the cost of reducing the current range in which the thermal-noise-like behavior dominates. This improvement in noise temperature is limited by the effects of the ohmic contact, which appear for large currents. The theory is formulated on general trends, allowing its application to the noise analysis of other semiconductor devices operating under strongly inhomogeneous distributions of the electric field and charge concentrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a microscopic analysis of shot-noise suppression due to long-range Coulomb interaction in semiconductor devices under ballistic transport conditions. An ensemble Monte Carlo simulator self-consistently coupled with a Poisson solver is used for the calculations. A wide range of injection-rate densities leading to different degrees of suppression is investigated. A sharp tendency of noise suppression at increasing injection densities is found to scale with a dimensionless Debye length related to the importance of space-charge effects in the structure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An analytical theory to describe the combined effects of the epitaxial layer thickness and the ohmic contact on the noise properties of Schottky barrier diodes is presented. The theory, which provides information on both the local and the global noise properties, takes into account the finite size of the epitaxial layer and the effects of the back ohmic contact, and applies to the whole range of applied bias. It is shown that by scaling down the epitaxial layer thickness, the current regime in which the noise temperature displays a shot-noise-like behavior increases at the cost of reducing the current range in which the thermal-noise-like behavior dominates. This improvement in noise temperature is limited by the effects of the ohmic contact, which appear for large currents. The theory is formulated on general trends, allowing its application to the noise analysis of other semiconductor devices operating under strongly inhomogeneous distributions of the electric field and charge concentrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Current technology trends in medical device industry calls for fabrication of massive arrays of microfeatures such as microchannels on to nonsilicon material substrates with high accuracy, superior precision, and high throughput. Microchannels are typical features used in medical devices for medication dosing into the human body, analyzing DNA arrays or cell cultures. In this study, the capabilities of machining systems for micro-end milling have been evaluated by conducting experiments, regression modeling, and response surface methodology. In machining experiments by using micromilling, arrays of microchannels are fabricated on aluminium and titanium plates, and the feature size and accuracy (width and depth) and surface roughness are measured. Multicriteria decision making for material and process parameters selection for desired accuracy is investigated by using particle swarm optimization (PSO) method, which is an evolutionary computation method inspired by genetic algorithms (GA). Appropriate regression models are utilized within the PSO and optimum selection of micromilling parameters; microchannel feature accuracy and surface roughness are performed. An analysis for optimal micromachining parameters in decision variable space is also conducted. This study demonstrates the advantages of evolutionary computing algorithms in micromilling decision making and process optimization investigations and can be expanded to other applications

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An undergraduate organic lab experiment is described based on the preparation of two readily accessible hydrazones. The UV-visible spectra of these N-H acids and of their conjugate bases are employed to illustrate the importance of through-conjugation in determining their acid strength and their internal charge-transfer-band transitions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study is to gather information regarding the adaptation of the range of socio educational projects and services aimed at the transition to an adult life of young persons with intellectual disabilities in Spain. The research of the study has been done in three stages. During each stage, a specific tool has been used. One to one in-depth interviews have been undertaken with 45 professionals and 20 individuals with intellectual disabilities. The Delphi method has been applied to two panels consisting of 20 experts each. Firstly, results focus on the approach to different issues related to the devices. Secondly, the training opportunities that these individuals receive to ease the transition period is addressed. And finally, the study refers to the participation of the individuals themselves and their families in the process. The developed analysis allows us to propose strategies to improve the transition to adult life

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Intraocular pressure (IOP) is the pressure inside the eye that helps to maintain the integrity and the suitable form of the ocular globe. Precise and accurate measures of IOP are needed for the diagnosis as well as follow-up of glaucoma. In daily clinical practice, Goldmann applanation tonometer (GAT) and Non-contact tonometer (NCT) are the most common devices for measuring IOP. A close agreement between these methods has been showed, particularly in normotensive patients and a poor agreement, especially when IOP levels are above the normal range. Ophthalmologists have noticed a poor agreement between NCT and GAT, observing that by using NCT and after comparing with GAT, there is an overestimation of IOP readings, and particularly it occurs when the eyes are tearful. Previous studies investigate the effect of tears in Non-contact tonometer readings by the instillation of artificial tears, concluding in one of the studies that the variation was less than 1mmHg and not clinically significant, in contrast with another study which the increases were sadistically significant. Tear menisci are a thin strip of tear fluid located between the bulbar conjunctiva and the eyelid margins. We think that the overestimation of IOP readings using NCT could be due to the presence of a higher volume of tear in the lower tear meniscus which might cause an optical interference in the optoelectronic applanation monitoring system of this deviceObjectives: To research the influence of a certain volume of fluid in the lower tear meniscus on IOP measurements using the NCT in healthy eyes. Moreover, to investigate the agreement between IOP readings obtained by NCT and GAT in the presence and absence of this volume of fluidMethods: The study design will be transversal for diagnostic tests of repeated measures. We will study patients with no ocular pathology and IOP<21mmHg. It will consist in the measurement of IOP using NCT before and after the instillation of COLIRCUSÍ FLUOTEST, used as a volume of fluid in the lower tear meniscus, to observe if there will be differences using the paired t-test. Moreover, we will take IOP measures by GAT in order to know the agreement between these methods after and before the application of these eyedrops, using the ICC (intraclass correlation coefficient) and the Bland-Altmann method

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The synthesis of gold nanoparticles (Au NPs) 15, 26, and 34 nm in diameter, followed by the investigation of their size-dependent optical and catalytic properties, is described herein as an undergraduate level experiment. The proposed experiment covers concepts on the synthesis, stabilization, and characterization of Au NPs, their size-dependent optical and catalytic properties at the nanoscale, chemical kinetics, and the role of a catalyst. The experiment should be performed by groups of two or three students in three lab sessions of 3 h each and organized as follows: i) synthesis of Au NPs of different sizes and investigation of their optical properties; ii) evaluation of their catalytic activity; and iii) data analysis and discussion. We believe that this activity enables students to integrate these multidisciplinary concepts in a single experiment as well as to become introduced/familiarized with an active research field and current literature in the areas of nanoparticle synthesis and catalysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The development of organic devices based on conducting polymers for biofilm detection requires the combination of superior electrical response and high surface area for biofilm incorporation. Polypyrrole is a potential candidate for application in biofilm detection and control due to its characteristic superior electrical response and strong interaction with bacteria, which enables the use of the bioelectric effect in resulting devices. In this study, chemically synthesized polypyrrole was applied as a support for biofilm growth of S. aureus. Modifications in the electrical response of the polymeric template were explored to identify general mechanisms established during the deposition of the biofilm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ZnO is a semiconductor material largely employed in the development of several electronic and optical devices due to its unique electronic, optical, piezo-, ferroelectric and structural properties. This study evaluates the properties of Ba-doped wurtzite-ZnO using quantum mechanical simulations based on the Density Functional Theory (DFT) allied to hybrid functional B3LYP. The Ba-doping caused increase in lattice parameters and slight distortions at the unit cell angle in a wurtzite structure. In addition, the doping process presented decrease in the band-gap (Eg) at low percentages suggesting band-gap engineering. For low doping amounts, the wavelength characteristic was observed in the visible range; whereas, for middle and high doping amounts, the wavelength belongs to the Ultraviolet range. The Ba atoms also influence the ferroelectric property, which is improved linearly with the doping amount, except for doping at 100% or wurtzite-BaO. The ferroelectric results indicate the ZnO:Ba is an strong option to replace perovskite materials in ferroelectric and flash-type memory devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

XML-muotoista tiedonesitystapaa hyödynnetään yhä enemmän esitettäessä rakenteellista tietoa. Tarkoituksena on antaa yleishyödyllinen ja uudelleenkäytettävä tapa jakaa yleistä tietoa erilaisten rajapintojen yli. XML-tekniikoita käytetään myös korjaamaan aiemmin tehdyissä sovellutuksissa esiintyneitä puutteita ja parantamaan niiden toimintaa. Tässä diplomityössä esitellään Telestelle LabView-pohjaiseen testaussovellusympäristöön suunniteltava ajuriuudistus. Työssä paranneltiin aiempaa ajurimallia soveltamalla siihen XML-tekniikoita hyödyntäviä toimintoja. Tarkoituksena oli vähentää testaussovelluskehityksessä vaadittavaa ohjelmointityötä korvaamalla sovelluksiin kovakoodatut ominaisuudet XML-pohjaisilla konfiguraatiotiedostoilla. Järjestelmän pohjana on yleiskäyttöinen ajuri, joka käyttää Telesten omaa EMS-protokollaa kommunikoinnissaan testattavien tuotteiden kanssa. Ajurimalli käyttää XML-pohjaisia konfiguraatiotiedostoja määrittelemään testattavien tuotteiden ominaisuuksia. XML-skeematiedostoilla esitetään ajurin käyttämän kommunikaatioprotokollan viestityypit ja niiden rakenteet. Työn tuloksena onnistuttiin luomaan uudenlainen XML-tekniikoita hyödyntävä ajurimalli. Yhteen yhteiseen ajuriin perustuva malli yhdenmukaistaa testaussovelluksien toteuttamista ja vähentää tarvittavaa ohjelmointityötä. Ajurin käyttöä helpotettiin toteuttamalla testaussovelluksien kehitysympäristöön erityinen editori, jolla voidaan helposti luoda ajuria käyttäviä toimintoja.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this thesis was to study how certificates could be used to improve security of mobile devices. In the theoretical part the usage of certificates to improve security is explained. In the practical part a concept of certificate handling middleware is introduced and implemented. This is to demonstrate what kind of functionality is needed to provide an improvement over the current situation in security with mobile devices. The certificate handling middleware is a concept that would work better if implemented directly into mobile device's core functionality. Many of the mobile devices have a certificate store to some degree and often it is not used to store other people's certificates. A certificate store combined with address book and added with possibility to add attributes to the people such as group memberships would be sufficient to satisfy the needs of many emerging sharing and social applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this thesis a closer look at ZigBee wireless network protocol was made and a ZigBee evaluation device was designed and built for testing it. ZigBee is a digital wireless network technology published in 2004, which was developed for wireless control and automation systems. It is based on the IEEE 802.15.4-2003 standard, and its aim was to create a reliable wireless networking protocol with secure data transmissions, low power consumption and low manufacturing costs. The low power consumption requirement has also led to a slow data rate and a short range, but in a ZigBee network individual network devices can route messages to each other, so short range is not a problem. In automation and control systems a fast data rate is not usually an important requirement either. ZigBee network can form automatically and one ZigBee network can theoretically include thousands of devices, all of which can communicate with each other. ZigBee network is also self-healing, so an individual device dropping out of the network, like breaking down, does not affect functionality of the network. Evaluation device was designed and implemented in four different versions, which were tested with six different antenna designs. All antennas were tested at a range of 100 meters in an open terrain using two different frequencies and transmission powers. Also a range test was performed for selected antennas using transmission power of 4,5 dBm, which was maximum power of the ZigBee chip used in the evaluation device. Range test resulted in a measured range of several hundred meters, which can be considered as a good result for a short-range technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The forthcoming media revolution of exchanging paper documents to digital media in construction engineering requires new tools to be developed. The basis of this bachelor’s thesis was to explore the preliminary possibilities of exporting imagery from a Building Information Modelling –software to a mobile phone on a construction yard. This was done by producing a Web Service which uses the design software’s Application Programming Interface to interact with a structures model in order to produce the requested imagery. While mobile phones were found lacking as client devices, because of limited processing power and small displays, the implementation showed that the Tekla Structures API can be used to automatically produce various types of imagery. Web Services can be used to transfer this data to the client. Before further development the needs of the contractor, benefits for the building master and inspector and the full potential of the BIM-software need to be mapped out with surveys.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose To evaluate the compliance and degree of satisfaction of nulligravida (has not given birth) and parous (had already given birth) women who are using intrauterine devices (IUDs). Methods A cross-sectional cohort study was conducted comparing nulligravida and parous women who had had an IUD inserted between July 2009 and November 2011. A total of 84 nulligravida women and 73 parous women were included. Interviews were conducted with women who agreed to participate through telephone contact. Statistical analysis was performed with Student s t-test and Mann-Whitney test for numeric variables; Pearson s chi-square test to test associations; and, whenever pertinent, Fisher s exact test for categorical variables. A survival curve was constructed to estimate the likelihood of each woman continuing the use of the IUD. A significance level of 5% was established. Results When compared with parous women, nulligravida women had a higher education level (median: 12 vs. 10 years). No statistically significant differences were found between the nulligravida and parous women with respect to information on the use of the IUD, prior use of other contraceptive methods, the reason for having chosen the IUD as the current contraceptive method, reasons for discontinuing the use and adverse effects, compliance, and degree of satisfaction. The two groups did not show any difference in terms of continued use of the IUD (p = 0.4). Conclusion There was no difference in compliance or the degree of satisfaction or continued use of IUDs between nulligravida and parous women, suggesting that IUD use may be recommended for women who have never been pregnant.