998 resultados para LIGAND-FREE
Resumo:
BACKGROUND: There are limited data on the composition and smoke emissions of 'herbal' shisha products and the air quality of establishments where they are smoked. METHODS: Three studies of 'herbal' shisha were conducted: (1) samples of 'herbal' shisha products were chemically analysed; (2) 'herbal' and tobacco shisha were burned in a waterpipe smoking machine and main and sidestream smoke analysed by standard methods and (3) the air quality of six waterpipe cafes was assessed by measurement of CO, particulate and nicotine vapour content. RESULTS: We found considerable variation in heavy metal content between the three products sampled, one being particularly high in lead, chromium, nickel and arsenic. A similar pattern emerged for polycyclic aromatic hydrocarbons. Smoke emission analyses indicated that toxic byproducts produced by the combustion of 'herbal' shisha were equivalent or greater than those produced by tobacco shisha. The results of our air quality assessment demonstrated that mean PM2.5 levels and CO content were significantly higher in waterpipe establishments compared to a casino where cigarette smoking was permitted. Nicotine vapour was detected in one of the waterpipe cafes. CONCLUSIONS: 'Herbal' shisha products tested contained toxic trace metals and PAHs levels equivalent to, or in excess of, that found in cigarettes. Their mainstream and sidestream smoke emissions contained carcinogens equivalent to, or in excess of, those of tobacco products. The content of the air in the waterpipe cafes tested was potentially hazardous. These data, in aggregate, suggest that smoking 'herbal' shisha may well be dangerous to health.
Resumo:
The complexing capacity of synthetic (0.011 M tartrate in 13.5% ethanol) and real wine (Raimat Abadia) in titrations with added total Zn concentrations up to 0.03 M has been determined following the free Zn concentrations with AGNES (absence of gradients and Nernstian equilibrium stripping) technique. A correction to find the preconcentration factor or gain (Y1) really applied at each one of the ionic strengths reached due to Zn additions along the titration has been applied. The standard implementation of AGNES to real wine led to the observation of two anomalous behaviors: (a) an increasingly negative current in the deposition stage (labeled as “HER” effect) and (b) a minimum in the currents of the stripping stage plot (labeled as the “dip” effect). A practical strategy to apply AGNES avoiding the dip effect has been developed to quantify properly free Zn concentrations. The van den Berg–Ružic–Lee linearization method (assuming the existence of just 1:1 complexes) has been adapted to consider the dilution effect and the ionic strength changes. Aggregated stability constants and total ligand concentrations have been calculated from synthetic and wine titration data. The found complexing capacity in the studied wine (cT,L = 0.0179 ± 0.0007 M) indicates the contribution of ligands other than tartrate (which is confirmed to be the main one).
Resumo:
Desarrollo de una aplicación basada en la localización y creación de rutas para personas discapacitadas, mayores, con movilidad reducida, con Alzheimer o demencia senil y personas que no puedan comunicarse verbalmente. La función de la aplicación es saber siempre su ubicación y, en caso de sufrir alguna crisis, llamar a sus cuidadores o familiares.
Resumo:
Selostus: Vapaan ja rajoitetun maitojuoton vaikutukset ayrshiresonnien kasvuun koko kasvatuskauden aikana ja teurastuloksiin
Resumo:
Tutkielma tarkastelee vapaa alue konseptia osana yritysten kansainvälistä toimitusketjua. Tarkoituksena on löytää keinoja, millä tavoin vapaa alueen houkuttelevuutta voidaan lisätä yritysten näkökulmasta ja millaista liiketoimintaa yritysten on vapaa alueella mahdollista harjoittaa. Tutkielmassa etsitään tekijöitä, jotka vaikuttavat vapaa alueen menestykseen ja jotka voisivat olla sovellettavissa Kaakkois-Suomen ja Venäjän raja-alueelle ottaen huomioon vallitsevat olosuhteet ja lainsäädäntö rajoittavina tekijöinä. Menestystekijöitä ja liiketoimintamalleja haetaan tutkimalla ja analysoimalla lyhyesti muutamia olemassa olevia ja toimivia vapaa alueita. EU tullilain harmonisointi ja kansainvälisen kaupan vapautuminen vähentää vapaa alueen perinteistä merkitystä tullivapaana alueena. Sen sijaan vapaa alueet toimivat yhä enenevissä määrin logistisina keskuksina kansainvälisessä kaupassa ja tarjoavat palveluita, joiden avulla yritykset voivat parantaa logistista kilpailukykyään. Verkostoituminen, satelliitti-ratkaisut ja yhteistoiminta ovat keinoja, millä Kaakkois-Suomen alueen eri logistiikkapalvelujen tarjoajat voivat parantaa suorituskykyään ja joustavuutta kansainvälisessä toimitusketjussa.
Resumo:
PURPOSE: To test the hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously using a single four-dimensional (4D) acquisition. METHODS: A free-running 4D whole-heart self-navigated acquisition incorporating a golden angle radial trajectory was implemented and tested in vivo in nine healthy adult human subjects. Coronary magnetic resonance angiography (MRA) datasets with retrospective selection of acquisition window width and position were extracted and quantitatively compared with baseline self-navigated electrocardiography (ECG) -triggered coronary MRA. From the 4D datasets, the left-ventricular end-systolic, end-diastolic volumes (ESV & EDV) and ejection fraction (EF) were computed and compared with values obtained from conventional 2D cine images. RESULTS: The 4D datasets enabled dynamic assessment of the whole heart with isotropic spatial resolution of 1.15 mm(3) . Coronary artery image quality was very similar to that of the ECG-triggered baseline scan despite some SNR penalty. A good agreement between 4D and 2D cine imaging was found for EDV, ESV, and EF. CONCLUSION: The hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously in vivo has been tested positive. Retrospective and flexible acquisition window selection allows to best visualize each coronary segment at its individual time point of quiescence. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.
Resumo:
In order to improve the efficacy and safety of treatments, drug dosage needs to be adjusted to the actual needs of each patient in a truly personalized medicine approach. Key for widespread dosage adjustment is the availability of point-of-care devices able to measure plasma drug concentration in a simple, automated, and cost-effective fashion. In the present work, we introduce and test a portable, palm-sized transmission-localized surface plasmon resonance (T-LSPR) setup, comprised of off-the-shelf components and coupled with DNA-based aptamers specific to the antibiotic tobramycin (467 Da). The core of the T-LSPR setup are aptamer-functionalized gold nanoislands (NIs) deposited on a glass slide covered with fluorine-doped tin oxide (FTO), which acts as a biosensor. The gold NIs exhibit localized plasmon resonance in the visible range matching the sensitivity of the complementary metal oxide semiconductor (CMOS) image sensor employed as a light detector. The combination of gold NIs on the FTO substrate, causing NIs size and pattern irregularity, might reduce the overall sensitivity but confers extremely high stability in high-ionic solutions, allowing it to withstand numerous regeneration cycles without sensing losses. With this rather simple T-LSPR setup, we show real-time label-free detection of tobramycin in buffer, measuring concentrations down to 0.5 μM. We determined an affinity constant of the aptamer-tobramycin pair consistent with the value obtained using a commercial propagating-wave based SPR. Moreover, our label-free system can detect tobramycin in filtered undiluted blood serum, measuring concentrations down to 10 μM with a theoretical detection limit of 3.4 μM. While the association signal of tobramycin onto the aptamer is masked by the serum injection, the quantification of the captured tobramycin is possible during the dissociation phase and leads to a linear calibration curve for the concentrations over the tested range (10-80 μM). The plasmon shift following surface binding is calculated in terms of both plasmon peak location and hue, with the latter allowing faster data elaboration and real-time display of the results. The presented T-LSPR system shows for the first time label-free direct detection and quantification of a small molecule in the complex matrix of filtered undiluted blood serum. Its uncomplicated construction and compact size, together with the remarkable performances, represent a leap forward toward effective point-of-care devices for therapeutic drug concentration monitoring.
Resumo:
NR2E3 encodes the photoreceptor-specific nuclear hormone receptor that acts as a repressor of cone-specific gene expression in rod photoreceptors, and as an activator of several rod-specific genes. Recessive variants located in the ligand-binding domain (LBD) of NR2E3 cause enhanced short wavelength sensitive- (S-) cone syndrome (ESCS), a retinal degeneration characterized by an excess of S-cones and non-functional rods. We analyzed the dimerization properties of NR2E3 and the effect of disease-causing LBD missense variants by bioluminescence resonance energy transfer (BRET(2) ) protein interaction assays. Homodimerization was not affected in presence of p.A256V, p.R039G, p.R311Q, and p.R334G variants, but abolished in presence of p.L263P, p.L336P, p.L353V, p.R385P, and p.M407K variants. Homology modeling predicted structural changes induced by NR2E3 LBD variants. NR2E3 LBD variants did not affect interaction with CRX, but with NRL and rev-erbα/NR1D1. CRX and NRL heterodimerized more efficiently together, than did either with NR2E3. NR2E3 did not heterodimerize with TLX/NR2E1 and RXRα/NR2C1. The identification of a new compound heterozygous patient with detectable rod function, who expressed solely the p.A256V variant protein, suggests a correlation between LBD variants able to form functional NR2E3 dimers and atypical mild forms of ESCS with residual rod function.
Resumo:
A double side-reaction, consisting in the formation of Fmoc--Ala-OH and Fmoc--Ala-AA-OH, during the preparation of Fmoc protected amino acids (Fmoc-AA-OH) with Fmoc-OSu is discussed. Furthermore, the new Fmoc-2-MBT reagent is proposed for avoiding these side-reactions as well as the formation of the Fmoc-dipeptides (Fmoc-AA-AA-OH) and even tripeptides, which is another important side-reaction when chloroformates such as Fmoc-Cl is used for the protection of the -amino function of the amino acids.
Resumo:
The avidity of the T-cell receptor (TCR) for antigenic peptides presented by the peptide-MHC (pMHC) on cells is a key parameter for cell-mediated immunity. Yet a fundamental feature of most tumor antigen-specific CD8(+) T cells is that this avidity is low. In this study, we addressed the need to identify and select tumor-specific CD8(+) T cells of highest avidity, which are of the greatest interest for adoptive cell therapy in patients with cancer. To identify these rare cells, we developed a peptide-MHC multimer technology, which uses reversible Ni(2+)-nitrilotriacetic acid histidine tags (NTAmers). NTAmers are highly stable but upon imidazole addition, they decay rapidly to pMHC monomers, allowing flow-cytometric-based measurements of monomeric TCR-pMHC dissociation rates of living CD8(+) T cells on a wide avidity spectrum. We documented strong correlations between NTAmer kinetic results and those obtained by surface plasmon resonance. Using NTAmers that were deficient for CD8 binding to pMHC, we found that CD8 itself stabilized the TCR-pMHC complex, prolonging the dissociation half-life several fold. Notably, our NTAmer technology accurately predicted the function of large panels of tumor-specific T cells that were isolated prospectively from patients with cancer. Overall, our results demonstrated that NTAmers are effective tools to isolate rare high-avidity cytotoxic T cells from patients for use in adoptive therapies for cancer treatment.
Resumo:
Free induction decay (FID) navigators were found to qualitatively detect rigid-body head movements, yet it is unknown to what extent they can provide quantitative motion estimates. Here, we acquired FID navigators at different sampling rates and simultaneously measured head movements using a highly accurate optical motion tracking system. This strategy allowed us to estimate the accuracy and precision of FID navigators for quantification of rigid-body head movements. Five subjects were scanned with a 32-channel head coil array on a clinical 3T MR scanner during several resting and guided head movement periods. For each subject we trained a linear regression model based on FID navigator and optical motion tracking signals. FID-based motion model accuracy and precision was evaluated using cross-validation. FID-based prediction of rigid-body head motion was found to be with a mean translational and rotational error of 0.14±0.21 mm and 0.08±0.13(°) , respectively. Robust model training with sub-millimeter and sub-degree accuracy could be achieved using 100 data points with motion magnitudes of ±2 mm and ±1(°) for translation and rotation. The obtained linear models appeared to be subject-specific as inter-subject application of a "universal" FID-based motion model resulted in poor prediction accuracy. The results show that substantial rigid-body motion information is encoded in FID navigator signal time courses. Although, the applied method currently requires the simultaneous acquisition of FID signals and optical tracking data, the findings suggest that multi-channel FID navigators have a potential to complement existing tracking technologies for accurate rigid-body motion detection and correction in MRI.