1000 resultados para K-Ar ages


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Sanitária

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente, perfil de Ordenamento do Território e Impactes Ambientais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com intuito de identificar a microbiota fúngica em condicionadores de ar nas unidades de terapia intensiva de hospitais públicos e particulares de Teresina-PI, coletou-se material sólido de dez UTIs, isolando 33 espécies pertencentes às Moniliaceae e Dematiaceae, sendo primeira referência para o Piauí. Registrou-se elevada freqüência de Aspergillus niger Van Tieghem (60%); Aspergillus fumigatus Fres (50%); Trichoderma koningii Oudem (50%), Aspergillus flavus Link: Fr (40%). A validade da limpeza dos condicionadores de ar ultrapassou em todas as UTIs, a quantidade de unidades formadoras de colônia estava além do permitido pela Portaria 176/00 do Ministério da Saúde. É importante que os profissionais estejam munidos de equipamento de proteção individual, além de adotar medidas de controle de infecção hospitalar, sensibilizar para a existência de infecções fúngicas, melhorar ventilação de ar, possibilitando arejamento do ambiente e limpar periodicamente os condicionadores de ar, conscientizando os profissionais de saúde da importância destes fungos no ambiente hospitalar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As análises ao ar exalado assumem cada vez uma maior importância como meio de diagnóstico não invasivo. O ar exalado encerra informações acerca do estado metabólico de cada pessoa, em particular, acerca das doenças, nutrição e medicação. Cada vez são em maior número os compostos encontrados na respiração humana com ligação a estados fisiológicos. A matriz respiratória, de caráter mais simples que a matriz sanguínea e urinária, é composta por gases inorgânicos, substâncias não voláteis e compostos orgânicos voláteis (VOCs). As concentrações individuais de cada VOC são na gama das partes por milhão (ppm) a partes por trilião (ppt), pelo que a sua deteção exige a utilização de uma técnica analítica com elevada sensibilidade. Este trabalho experimental teve como objetivo principal analisar os compostos orgânicos voláteis em doentes renais. Neste sentido, analisou-se o ar exalado de doentes em hemodiálise, antes e após o tratamento. Realizaram-se, também, análises ao ar exalado de doentes em estádios intermédios da doença renal crónica (DRC3 e DRC4), a fim de verificar a existência de um padrão evolutivo através da análise ao ar exalado. Para tal utilizou-se o BreathSpec®, uma técnica analítica não invasiva e de elevada sensibilidade, cujo princípio físico de funcionamento é a espetrometria de mobilidade iónica acoplada a uma coluna multicapilar (MCC-IMS). Este trabalho foi realizado em colaboração com a Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa (FCT/UNL), NMT,S.A. e o serviço de Nefrologia do Hospital Garcia de Orta. Futuramente, pretende-se que esta técnica seja utilizada como meio de diagnóstico precoce da doença renal, bem como, nos casos de pacientes em estádio final da doença, avaliar a eficácia da hemodiálise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O Arquivo tem como funções primordiais, entre outras, comunicar e difundir o seu património, sendo as exposições um modo eficaz de o fazer. Por meio destas, o Arquivo dá a conhecer os conjuntos documentais que encerra e divulga o trabalho que leva a cabo. O presente trabalho tem numa primeira instância o objectivo de abordar três das exposições levadas a cabo na DGLAB, sendo descrito o trabalho levado a cabo e o modo como este contribuiu para o desenvolvimento do produto final. O desenvolvimento e ampliação da utilização das tecnologias de informação e comunicação (TIC) proporcionam aos Arquivos e outras instituições, como Bibliotecas e Museus, a possibilidade de acentuar estas duas funções, por meio da criação na web de exposições virtuais, que utilizam as ferramentas que advêm destas novas tecnologias. Neste sentido, é necessário compreender como é que as diferentes instituições fazem uso destas ferramentas na criação das suas exposições virtuais, uma vez que existem distintas tipologias com diversas aplicações. Procura-se assim nesta linha, escolher boas práticas de exposições virtuais e detalhar as suas potencialidades de modo a retirar ideias que se coadunem com as especificidades da exposição física para a qual se planeia criar uma exposição virtual. Este Relatório de Estágio procura assim responder à questão: Como pode uma exposição virtual valorizar uma exposição física de modo a contribuir para o desenvolvimento das funções de comunicação/ difusão na DGARQ?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: Avaliou-se o nível da contaminação do ar em cirurgias ortopédicas. MÉTODOS: O ar das salas cirúrgicas foi analisado microbiologicamente através da exposição de placas próximas à mesa cirúrgica por uma hora. RESULTADOS: Foram evidenciados valores acima do recomendado (369 UFC/m³) nas salas convencionais, assim como naquelas com ar ultralimpo. A contaminação foi predominantemente por Staphylococcus sp (86,9%). verificou-se um número alto de pessoas presentes no interior das salas cirúrgicas, assim como de abertura da porta. CONCLUSÕES: Os níveis de contaminação se apresentaram acima dos valores aceitos por agências reguladoras, representando risco para os pacientes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thermal Energy Storage Unit (ESU) could be used to attenuate inherent temperature fluctuations of a cold finger, either from a cryocooler working or due to sudden income heat bursts. An ESU directly coupled to the cold source acts as a thermal buffer temporarily increasing its cooling capacity and providing a better thermal stability of the cold finger (“Power Booster mode”). The energy storage units presented here use an enthalpy reservoir based on the high latent heat of the liquid-vapour transition of neon in the temperature range 38 - 44 K to store up to 900 J, and that uses a 6 liters expansion volume at RT in order to work as a closed system. Experimental results in the power booster mode will be described: in this case, the liquid neon cell was directly coupled to the cold finger of the working cryocooler, its volume (12 cm3) allowing it to store 450 J at around 40 K. 10 W heat bursts were applied, leading to liquid evaporation, with quite reduced temperature changes. The liquid neon reservoir can also work as a temporary cold source to be used after stopping the cryocooler, allowing for a vibration-free environment. In this case the enthalpy reservoir implemented (24 cm3) was linked to the cryocooler cold finger through a gas gap heat switch for thermal coupling/decoupling of the cold finger. We will show that, by controlling the enthalpy reservoir’s pressure, 900 J can be stored at a constant temperature of 40 K as in a triple-point ESU.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices, implemented as a software,describes quite well the experimental results. Solutions to improve these devices are also proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices,implemented as a software, describes quite well the experimental results. Solutions to improve these devices are also proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NSBE - UNL

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Num mundo globalizado, as organizações têm sido forçadas a inovar em busca de novas técnicas de gestão, devido a limitações dos modelos de gestão tradicional. Para subsistir num mercado altamente competitivo, as organizações procuram diferenciar-se da concorrência por via de utilização de novas metodologias de gestão que permitam aumentar a eficiência dos processos internos. A implementação de fundamentos e técnicas da metodologia Lean, em conjunto com os conceitos e os instrumentos analíticos da metodologia TRIZ, pode auxiliar as organizações na procura de melhoria contínua em todas as áreas funcionais, encontrando soluções mais criativas e inovadoras. A presente dissertação foi elaborada no âmbito de um estágio curricular realizado numa empresa metalomecânica, que atua no setor industrial de tratamento de ar e de ventilação. Os objetivos do estágio delineados inicialmente visavam o estudo da melhoria de organização do armazém numa das unidades industriais do grupo. No decorrer do estágio, foi possível não só melhorar em vários aspetos o funcionamento do armazém, como também foram elaboradas e implementadas várias ações de melhoria nas outras áreas funcionais da empresa. A análise efetuada à situação atual da empresa e as soluções encontradas para os problemas identificados basearam-se em algumas técnicas e instrumentos analíticos das metodologias Lean e TRIZ. Entre os vários resultados obtidos, destacam-se a redução significativa de stocks, a reorganização da hierarquia funcional, a melhoria do fluxo de informação interna e externa (entre a empresa e os fornecedores), a criação de um sistema de deteção de não conformidades com origem nos fornecedores, entre outros. No desenvolvimento deste estágio e com base nos resultados obtidos, foi submetido e aceite um artigo e uma proposta para o concurso de projetos no âmbito de The 6th International Conference on Systematic Innovation (ICSI) & The 5th Global Competition on Systematic Innovation (GCSI).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado apresentada ao ISPA - Insituto Universitário

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mutations at codons 12, 13, or 61 of the H-ras, K-ras, and N-ras have been detected in human neoplasias by a variety of techniques. Some of these techniques are very sensitive and can detect K-ras mutation in 90% of the cases of pancreatic adenocarcinomas. We analyzed 11 samples of pancreatic adenocarcinoma, three samples of pancreatic mucinous cystadenoma, and two samples without tumors in formalin-fixed paraffin embedded tissue sections. K-ras mutations at codon 12 were detected by a two-step PCR-enriched technique in all the samples of pancreatic adenocarcinoma, but not in cystadenoma or control samples. This technique may be useful for early detection of pancreatic cancer.