903 resultados para Intraaortic Balloon Pump


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Venous leg ulcers are a significant cause of chronic ill-health, whilst patients often experience reduced mobility and poor quality of life. This research investigated exercise as a tool for improving outcomes for adults with venous leg ulcers. The results showed that patients who adhere to an exercise program as an adjunct treatment to standard care are more likely to heal than those who do not adhere to an exercise program. This research has the potential to improve the health of venous leg ulcer patients and decrease health care costs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Variability is observed at all levels of cardiac electrophysiology. Yet, the underlying causes and importance of this variability are generally unknown, and difficult to investigate with current experimental techniques. The aim of the present study was to generate populations of computational ventricular action potential models that reproduce experimentally observed intercellular variability of repolarisation (represented by action potential duration) and to identify its potential causes. A systematic exploration of the effects of simultaneously varying the magnitude of six transmembrane current conductances (transient outward, rapid and slow delayed rectifier K(+), inward rectifying K(+), L-type Ca(2+), and Na(+)/K(+) pump currents) in two rabbit-specific ventricular action potential models (Shannon et al. and Mahajan et al.) at multiple cycle lengths (400, 600, 1,000 ms) was performed. This was accomplished with distributed computing software specialised for multi-dimensional parameter sweeps and grid execution. An initial population of 15,625 parameter sets was generated for both models at each cycle length. Action potential durations of these populations were compared to experimentally derived ranges for rabbit ventricular myocytes. 1,352 parameter sets for the Shannon model and 779 parameter sets for the Mahajan model yielded action potential duration within the experimental range, demonstrating that a wide array of ionic conductance values can be used to simulate a physiological rabbit ventricular action potential. Furthermore, by using clutter-based dimension reordering, a technique that allows visualisation of multi-dimensional spaces in two dimensions, the interaction of current conductances and their relative importance to the ventricular action potential at different cycle lengths were revealed. Overall, this work represents an important step towards a better understanding of the role that variability in current conductances may play in experimentally observed intercellular variability of rabbit ventricular action potential repolarisation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biventricular support with dual rotary ventricular assist devices (VADs) has been implemented clinically with restriction of the right VAD (RVAD) outflow cannula to artificially increase afterload and, therefore, operate within recommended design speed ranges. However, the low preload and high afterload sensitivity of these devices increase the susceptibility of suction events. Active control systems are prone to sensor drift or inaccurate inferred (sensor-less) data, therefore an alternative solution may be of benefit. This study presents the in vitro evaluation of a compliant outflow cannula designed to passively decrease the afterload sensitivity of rotary RVADs and minimize left-sided suction events. A one-way fluid-structure interaction model was initially used to produce a design with suitable flow dynamics and radial deformation. The resultant geometry was cast with different initial cross-sectional restrictions and concentrations of a softening diluent before evaluation in a mock circulation loop. Pulmonary vascular resistance (PVR) was increased from 50 dyne s/cm5 until left-sided suction events occurred with each compliant cannula and a rigid, 4.5 mm diameter outflow cannula for comparison. Early suction events (PVR ∼ 300 dyne s/cm5) were observed with the rigid outflow cannula. Addition of the compliant section with an initial 3 mm diameter restriction and 10% diluent expanded the outflow restriction as PVR increased, thus increasing RVAD flow rate and preventing left-sided suction events at PVR levels beyond 1000 dyne s/cm5. Therefore, the compliant, restricted outflow cannula provided a passive control system to assist in the prevention of suction events with rotary biventricular support while maintaining pump speeds within normal ranges of operation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pumping systems are widely used in many applications, including municipal water/wastewater services, domestic, commercial and agricultural services, and industrial processes. They are a very significant energy user and consume nearly 20% of the world’s electrical energy demand. Therefore, improving the energy efficiency of pumping systems can provide great benefits in terms of energy, environment, and cost reduction. In this entry, an overview of pump classification with pros and cons of each type of pump is presented. The procedures used to design pumping systems are also outlined. This is then followed by a discussion on the opportunities for improving the energy efficiency of pumping systems during every stage of design, selection, operation, and maintenance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To develop a set of Australian recommendations for the monitoring and treatment of ankylosing spondylitis (AS) through systematic literature review combined with the opinion of practicing rheumatologists. Methods: A set of eight questions, four in each domain of monitoring and treatment, were formulated by voting and the Delphi method. The results of a systematic literature review addressing each question were presented to the 23 participants of the Australian 3E meeting. All participants were clinical rheumatologists experienced in the daily management of AS. Results: After three rounds of breakout sessions to discuss the findings of the literature review, a set of recommendations was finalized after discussion and voting. The category of evidence and strength of recommendation were determined for each proposal. The level of agreement among participants was excellent (mean 84%, range 64-100%). Conclusions: The 12 recommendations developed from evidence and expert opinion provide guidance for the daily management of AS patients. For most recommendations, we found a paucity of supportive evidence in the literature highlighting the need for additional clinical studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article follows on from our previous article in Aeronotes Volume 37 No.2 "Prepare and prevent, don't repair and repent: Causal factors of hot air ballooning incidents". While nearly every balloon flight ends safely, with every flight comes the opportunity for an accident. The ABF maintains an incident reporting database containing information on all the accidents and near misses that are reported to them. The goal of the database is to provide a formal way for ABF members to share accident or near miss experiences and prevent future occurrences. We recently analysed the causal factors involved in the incident reports collected by the ABF. Twenty-two incident reports were analysed and 54 causal factors were identified that were reported to play a role in hot air ballooning accidents. While many factors were identified, the findings of this study were limited by the small number of incident reports available from the ABF reporting system...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experiments in spintronics necessarily involve the detection of spin polarization. The sensitivity of this detection becomes an important factor to consider when extending the low temperature studies on semiconductor spintronic devices to room temperature, where the spin signal is weaker. In pump-probe experiments, which optically inject and detect spins, the sensitivity is often improved by using a photoelastic modulator (PEM) for lock-in detection. However, spurious signals can arise if diode lasers are used as optical sources in such experiments, along with a PEM. In this work, we eliminated the spurious electromagnetic coupling of the PEM onto the probe diode laser, by the double modulation technique. We also developed a test for spurious modulated interference in the pump-probe signal, due to the PEM. Besides, an order of magnitude enhancement in the sensitivity of detection of spin polarization by Kerr rotation, to 3x10(-8) rad was obtained by using the concept of Allan variance to optimally average the time series data over a period of 416 s. With these improvements, we are able to experimentally demonstrate at room temperature, photoinduced steady-state spin polarization in bulk GaAs. Thus, the advances reported here facilitate the use of diode lasers with a PEM for sensitive pump-probe experiments. They also constitute a step toward detection of spin-injection in Si at room temperature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A defect-selective photothermal imaging system for the diagnostics of optical coatings is demonstrated. The instrument has been optimized for pump and probe parameters, detector performance, and signal processing algorithm. The imager is capable of mapping purely optical or thermal defects efficiently in coatings of low damage threshold and low absorbance. Detailed mapping of minor inhomogeneities at low pump power has been achieved through the simultaneous action of a low-noise fiber optic photothermal beam defection sensor and a common-mode-rejection demodulation (CMRD) technique. The linearity and sensitivity of the sensor have been examined theoretically and experimentally, and the signal to noise ratio improvement factor is found to be about 110 compared to a conventional bicell photodiode. The scanner is so designed that mapping of static or shock sensitive samples is possible. In the case of a sample with absolute absorptance of 3.8 x 10(-4), a change in absorptance of about 0.005 x 10(-4) has been detected without ambiguity, ensuring a contrast parameter of 760. This is about 1085% improvement over the conventional approach containing a bicell photodiode, at the same pump power. The merits of the system have been demonstrated by mapping two intentionally created damage sites in a MgF2 coating on fused silica at different excitation powers. Amplitude and phase maps were recorded for thermally thin and thick cases, and the results are compared to demonstrate a case which, in conventional imaging, would lead to a deceptive conclusion regarding the type and location of the damage. Also, a residual damage profile created by long term irradiation with high pump power density has been depicted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A microcontroller based, thermal energy meter cum controller (TEMC) suitable for solar thermal systems has been developed. It monitors solar radiation, ambient temperature, fluid flow rate, and temperature of fluid at various locations of the system and computes the energy transfer rate. It also controls the operation of the fluid-circulating pump depending on the temperature difference across the solar collector field. The accuracy of energy measurement is +/-1.5%. The instrument has been tested in a solar water heating system. Its operation became automatic with savings in electrical energy consumption of pump by 30% on cloudy days.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One hundred and seven children with faecal incontinence were evaluated and managed over a 3 year period by a multidisciplinary team. After initial clinical assessment, evaluation of defaecatory mechanisms (using a balloon model) and assessment of personal-social development and self-concept were undertaken. Management was based on initial bowel evacuation, short-term laxatives, and habit training involving systematic use of positive reinforcement; 69 children received biofeedback conditioning. Idiopathic megacolon with constipation and soiling was the most common finding (98 cases). Other diagnoses included previously undiagnosed neurogenic bowel (three cases), post-surgical anal anomalies (four cases), and psychogenic encopresis (two cases). Idiopathic megacolon was characterized by decreased rectal sensation, increased threshold for external sphincter relaxation and an inability to evacuate. Faecal incontinence was associated with an undesirably low social self-concept (70% of the 40 evaluated), but was not related to a delay in development (mean general developmental quotient = 105 ± 8, for the 35 tested). Family psychopathology warranting referral for family therapy was found in 14 children (13%). The management programme yielded a short-term (3 months) cure rate of 68% and a long-term (12 months) cure rate of 90%, with 10% having continued soiling which varied from occasional to several incidents/week. No significant improvement in self-concept was observed overall, although marked improvements were observed in some children. We conclude that disordered defaecatory dynamics are a major determinant of faecal incontinence in children. Undesirably low social self-concepts but normal developmental ability accompany this condition. Management is facilitated by a multidisciplinary approach, acknowledging the role of both behavioural and physiological components of the problem. This approach is effective in eradicating soiling in the majority of cases, comparing favourably with other published data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A low-altitude platform utilising a 1.8-m diameter tethered helium balloon was used to position a multispectral sensor, consisting of two digital cameras, above a fertiliser trial plot where wheat (Triticum spp.) was being grown. Located in Cecil Plains, Queensland, Australia, the plot was a long-term fertiliser trial being conducted by a fertiliser company to monitor the response of crops to various levels of nutrition. The different levels of nutrition were achieved by varying nitrogen application rates between 0 and 120 units of N at 40 unit increments. Each plot had received the same application rate for 10 years. Colour and near-infrared images were acquired that captured the whole 2 ha plot. These images were examined and relationships sought between the captured digital information and the crop parameters imaged at anthesis and the at-harvest quality and quantity parameters. The statistical analysis techniques used were correlation analysis, discriminant analysis and partial least squares regression. A high correlation was found between the image and yield (R2 = 0.91) and a moderate correlation between the image and grain protein content (R2 = 0.66). The utility of the system could be extended by choosing a more mobile platform. This would increase the potential for the system to be used to diagnose the causes of the variability and allow remediation, and/or to segregate the crop at harvest to meet certain quality parameters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recirculating aquaculture systems have a unique anthropogenic-based soundscape which is characterized by the type of equipment utilized, the structural configuration of walls, tanks, equipment, the substrate the tanks are situated on and even the activities of the personnel operating the facility. The soundscape of recirculation facilities is inadequately understood and remains poorly characterized, although it is generally accepted that the dominant sounds found in such facilities are within the hearing range of fish. The objective of this study was to evaluate the soundscape in a recirculating aquaculture facility from an intra-tank perspective and determine how the soundscape is shaped by a range of characteristics within the facility. Sounds were recorded across an operating aquaculture facility including different tank designs. The sounds recorded fell within previously measured pressure level ranges for recirculating systems, with the highest maximum sound pressure level (SPL) recorded at 124 dB re 1 mu Pa-2/Hz (with an FFT bin width of 46.9 Hz, centered at 187.5 Hz). The soundscape within the tanks was stratified and positively correlated with depth, the highest sound pressure occurring at the base of the tanks. Each recording of the soundscape was dominated by a frequency component of 187.5 Hz (corresponding centre of the 4th 46.9 Hz FFT analysis bin) that produced the highest observed SPL Analysis of sound recordings revealed that this peak SPL was associated with the acoustic signature of the pump. The soundscape was also evaluated for impacts of tank hood position, time of day, transient sounds and airstone particle size types, all of which were found to appreciably influence sound levels and structure within the tank environment. This study further discusses the distinctiveness of the soundscape, how it is shaped by the various operating components and considers the aquaculture soundscape in relation to natural soundscapes found within aquatic tropical environments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper gives a brief survey of research and development work done on hand pumps in India as well as elsewhere and sets out the approach adopted by ASTRA Working Group. Ten ways in which a hand pump breakdown in practice have been identified. The physical reasons behind each type of breakdown analysed. Remedial measures have been developed from this analysis. Laboratory test rigs fabricated to evaluate these measures have been described and some experimental results presented. The course of further work has been charted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is shown that a leaky aquifer model can be used for well field analysis in hard rock areas, treating the upper weathered and clayey layers as a composite unconfined aquitard overlying a deeper fractured aquifer. Two long-duration pump test studies are reported in granitic and schist regions in the Vedavati river basin. The validity of simplifications in the analytical solution is verified by finite difference computations.