957 resultados para GROUP-3 METAL-COMPLEXES


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate in vitro the degree of marginal leakage in Class V cavities involving the cementoenamel junction. Cavities were 4 rum wide and 2 mm deep. The specimens received dentin pretreatment (37% phosphoric acid) followed by the Single Bond (3M) adhesive system application. The 40 specimens were then divided into four groups: Group I (control); Group 2 (Nd:YAG laser at 120 mJ/pulse, frequency of 10 Hz, power of 1.2 W); Group 3 (Nd:YAG laser at 140 mJ/pulse, frequency of 10 Hz, power of 1.4 W); Group 4 (Nd:YAG laser at 160 mJ/pulse, frequency of 10 Hz, power of 1.6 W). The cavities were restored with Z100 composite resin (3M) and light cured at 300-600 mW/cm(2) light intensity. Specimens were thermocycled to 500 cycles from 2-50 degrees C. After that, they were dried and sealed with nail varnish, respecting 1 mm around the restorations, and immersed in 0.5% methylene blue solution for 4 h. After this period, the teeth were rinsed, dried, sectioned, and analyzed in a stereoscopic loupe. The highest leakage scores were considered for each specimen. The results were statistically analyzed by the analysis of variance (ANOVA) Kruskal-Wallis test to the 5% level. For both the enamel and cementum, there was a decrease in marginal leakage with the application of laser energy; no significant differences were observed for Groups 2, 3, and 4. The results also showed a smaller tendency to marginal leakage on the cementum than on the enamel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar o selamento de ápices radiculares tratados com diferentes agentes desmineralizantes e retrobturados com agregado de trióxido mineral (MTA), mediante infiltração marginal por corante. Cinqüenta e seis dentes unirradiculares humanos extraídos foram instrumentados, obturados e seccionados apicalmente. Os preparos cavitários apicais foram confeccionados com pontas ultra-sônicas e os agentes desmineralizantes foram aplicados previamente à retrobturação com Pro Root MTA. Os espécimes foram divididos aleatoriamente em 4 grupos (n=14): grupo 1 (sem agente desmineralizante); grupo 2 (ácido fosfórico 35% durante 15 s); grupo 3 (solução de EDTA 17%, pH 7, durante 3 min); grupo 4 (gel de EDTA 24%, pH 7, durante 4 min). A extensão da infiltração de corante (rodamina B 2% a 37°C, por 24 h) foi avaliada em milímetros utilizando-se um estereomicroscópio. Os resultados foram analisados estatisticamente por meio de análise de variância a um critério e do teste Tukey com nível de significância de 5%. Dentre os grupos experimentais, a menor extensão de infiltração do corante foi verificada no grupo 1 (1,89 mm), seguido pelos grupos 2 (2,18 mm), 4 (2,54 mm) e 3 (2,64 mm). Não houve diferenças estatisticamente significante (p>0.05) na infiltração marginal pelo corante entre os grupos 1, 2 e 4 e os grupos 2, 3 e 4. Com base nos resultados obtidos, pode-se concluir que a aplicação de agentes desmineralizantes não pode ser recomendada quando da utilização do MTA em cirurgias parendodônticas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Avaliar se fontes de luz aumentam a eficácia do peróxido de hidrogênio na técnica de clareamento profissional. METODOLOGIA: Foram empregados 60 dentes incisivos bovinos, com dimensões coronárias e radiculares padronizadas a partir do limite amelo-cementário, sendo descartada a porção lingual. Os corpos-de-prova (cp) foram limpos em ultra-som por 20 min e a dentina condicionada com H3PO4 a 38% por 15 s, sendo os (cp) imersos em solução de café solúvel a 25% por duas semanas. A dentina foi impermeabilizada com esmalte e os (cp) divididos em 5 grupos, sendo a cor inicial mensurada através do espectofotômetro-EasyShade (VITA). Todos os (cp) receberam três aplicações por 10 min do gel clareador Opalescence Xtra-Boost (Ultradent) conforme segue: Grupo 1 - controle, não recebeu fotoativação, Grupo 2 - ativado com luz halôgena, Grupo 3 - ativado com LED azul/LASER, Grupo 4 - ativado com LED verde/LASER e Grupo 5 - ativado com LED vermelho. Após o clareamento foi mensurada a variação de cor E, a*, b*e L* e as referentes à escala de cor Vita Clássico. Os dados foram submetidos à análise de variância, teste de Tukey e de Dunn (α=5%). RESULTADOS: A diferença geral da cor foi reduzida quando se empregou LED Azul e Luz Halógena, sendo que o desempenho do peróxido de hidrogênio a 38% foi intensificado dependendo da fonte de luz utilizada. A avaliação quantitativa de cor, obtida por espectrofotômetro e pela escala de cor Vita Clássico, foram coincidentes. CONCLUSÃO: O tipo de fonte de luz empregada interfere na eficácia do agente clareador.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the cohesive strength of composite using self-etching adhesive systems (SE) in the lubrication of instruments between layers of composite. The specimens were made by using a Teflon (R) device. SE were used at the interface to lubricate the instruments: Group 1(G1) - control group, no lubricant was used; Group 2(G2) -Futurabond (R) M; Group 3(G3) - Optibond (R) All-In-One; Group 4(G4) - Clearfil (R) SE Bond; Group 5(G5) - Futurabond (R) NR; Group 6(G6) - Adper (R) SE Plus; Group 7(G7) - One Up Bond (R) F. Specimens were submitted to the tensile test to evaluate the cohesive strength. Data were submitted to the ANOVA and Tukey tests. ANOVA showed a value of p = 0.00. The average means (SD): G2 = 11.33(+/-3.44) a, G3 = 15.36(+/-4.06) ab, G4 = 18.9(+/-4.72) bc, G7 = 19.62(+/-4.46) bc, G5 = 21.02(+/-5.09) bc, G6 = 23.39(+/-4.17) cd, and G1 = 28.49(+/-2.89) d. All SE decreased the cohesive strength of the composite, except for Adper (R) SE Plus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the bond strength of indirect restorations to dentin using self-adhesive cements with and without the application of adhesive systems.Material and Methods: Seventy-two bovine incisors were used, in which the buccal surfaces were ground down to expose an area of dentin measuring a minimum of 4 x 4 mm. The indirect resin composite Resilab was used to make 72 blocks, which were cemented onto the dentin surface of the teeth and divided into 4 groups (n = 18): group 1: self-adhesive resin cement BiFix SE, applied according to manufacturer's recommendations; group 2: self-adhesive resin cement RelyX Unicem, used according to manufacturer's recommendations; group 3: etch-and-rinse Solobond M adhesive system + BiFix SE; group 4: etch-and-rinse Single Bond 2 adhesive system + RelyX Unicem. The specimens were sectioned into sticks and subjected to microtensile testing in a universal testing machine (EMIC DL-200MF). Data were subjected to one-way ANOVA and Tukey's test (alpha = 5%).Results: The mean values (+/- standard deviation) obtained for the groups were: group 1: 15.28 (+/- 8.17)(a), group 2: 14.60 (+/- 5.21)(a), group 3: 39.20 (+/- 9.98)(c), group 4: 27.59 (+/- 6.57)(b). Different letters indicate significant differences (ANOVA; p = 0.0000).Conclusion: The application of adhesive systems before self-adhesive cements significantly increased the bond strength to dentin. In group 2, RelyX Unicem associated with the adhesive system Single Bond 2 showed significantly lower mean tensile bond strengths than group 3 (BiFix SE associated with the etch-and-rinse Solobond M adhesive system).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the cohesive strength between composite and different light-curing characterizing materials (LCCM), which were prepared using the intrinsic technique.Materials and Methods: One hundred composite specimens were made by using a prefabricated Teflon device, and a layer of LCCM was applied at the interface. The specimens were divided into 5 groups (n = 20): group 1 (control), no LCCM was used; group 2: application of White Kolor Plus Pigment (Kerr) LCCM; group 3: White Tetric Color Pigment (Ivoclar/Vivadent) LCCM; group 4: Brown Kolor Plus Pigment (Kerr) LCCM; group 5: Black Tetric Color Pigment (Ivoclar/Vivadent) LCCM. All materials were used according to the manufacturers' instructions. Specimens were submitted to a tensile test in a universal testing machine (EMIC DL-200MF) to evaluate the cohesive strength at the composite interface. Data were subjected to one-way ANOVA and Tukey's test (alpha = 5%).Results: ANOVA showed a p-value = 0.0001, indicating that there were significant differences among the groups. The mean values in MPa (+/- standard deviation) obtained for the groups were: G1: 28.5 (+/-2.74)a; G2: 23.5 (+/-2.47)b; G3: 20.3 (+/-2.49)b; G4: 10.5 (+/-2.40)c; G5: 9.66 (+/-3.06)c. The groups with the same letters presented no significant differences. The control group presented statistically significantly higher cohesive strengths when compared to the other groups. The groups in which Brown Kolor Plus Pigment and Black Tetric Color Pigment LCCM were used showed significantly lower cohesive strengths when compared to the groups in which White Kolor Plus Pigment and White Tetric Color Pigment LCMM were used.Conclusion: The use of LCCM produced with the intrinsic technique reduced the cohesive strength of composite.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To determine whether chewing side preference (CSP) is correlated to lateralities (handedness, footedness, eyedness and earedness) in primary, mixed and permanent dentitions.Design: Three-hundred subjects were divided into 3 groups: Group 1-100 children 3-5 years old, primary dentition; Group 2-100 children 6-12 years old, mixed dentition; Group 3 - 100 subjects 18-47 years old, permanent dentition. CSP was determined using a method developed by Mc Donnell et al.(9) Subjects were given a piece of gum and the position of the chewing gum was recorded 7 times as right or left. Subjects were classified as 'observed preferred chewing side' (OPCS) when they performed 5/7, 6/7 or 7/7 strokes on the same side. OPCS corresponded to the CSP. Laterality tests were performed for handedness, footedness, eyedness and earedness tasks. The Chi-square (chi(2)) and phi correlation (r) tests were used to investigate significant correlations between CSP and sidedness.Results: There was a significant correlation between chewing and earedness (p = 0.00), although there was weak positive correlation (r = 0.30) for primary dentition. There were significant correlations between chewing and handedness (p = 0.02; r = 0.25) and chewing and footedness (p = 0.02; r = 0.26), however, there were weak positive correlations for mixed dentition; there were significant correlations between chewing and handedness (p = 0.02; r = 0.26); chewing and footedness (p = 0.00; r = 0.33) and chewing and earedness (p = 0.01; r = 0.29); however, there were weak positive correlations for permanent dentition.Conclusion: It may be concluded that CSP can be significantly correlated with: earedness for primary dentition; handedness and footedness for mixed dentition; handedness, footedness and earedness for permanent dentition, but these are weak positive relationships. Future work on larger samples of left- and right-sided individuals is required to validate the findings. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente trabalho objetivou avaliar a eficácia do tratamento Ovsynch associado à inseminação artificial em tempo prefixado em vacas Bos taurus e Bos indicus. Foram utilizados rebanhos das raças Holandesa, Caracu, Nelore e Mantiqueira. Também foi incluído um rebanho de vacas Gir, com problemas de fertilidade. Cada rebanho foi dividido em três grupos. O grupo 1 recebeu o tratamento Ovsynch e foi inseminado em tempo prefixado. O grupo 2 foi inseminado no cio induzido com cloprostenol. O grupo 3 foi inseminado no cio natural. As taxas de concepção e de prenhez foram determinadas por ultra-sonografia. Não existiu interação significativa das variáveis reprodutivas analisadas para rebanho, idade, período pós-parto, número de parição e presença do bezerro. A taxa de concepção não diferiu (P>0,05) entre os grupos, ao passo que a taxa de prenhez foi superior (P<0,05) nos grupos 1 e 2 em comparação ao grupo 3. No rebanho Gir, o tratamento Ovsynch não alterou a taxa de concepção nem a de prenhez. Independentemente da raça, os tratamentos Ovsynch e cloprostenol não afetam a taxa de concepção, mas melhoram a taxa de prenhez. O tratamento Ovsynch não aumenta a fertilidade de vacas com problemas reprodutivos inespecíficos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Racional - A fundoplicatura total, procedimento empregado no tratamento da doença do refluxo gastroesofágico, pode ser realizada segundo duas técnicas de abordagem: laparotômica e laparoscópica. Objetivo - Analisar o esfíncter inferior do esôfago de coelhos submetidos a fundoplicatura total laparotômica e laparoscópica. Material e Métodos - em 40 coelhos machos foram realizados estudos eletromanométricos do esôfago segundo a técnica de puxada intermitente da sonda e infusão contínua dos cateteres com água destilada. Estes estudos permitiram a análise de dois parâmetros: amplitude da pressão no esfíncter inferior do esôfago (mm Hg) e comprimento do esfíncter inferior do esôfago em condições basais (momento 1). Os 40 animais foram divididos em quatro grupos de 10, na dependência do procedimento cirúrgico realizado: grupo 1: fundoplicatura total laparotômica; grupo 2: laparotomia mediana e dissecção da transição gastroesofágica; grupo 3: fundoplicatura total laparoscópica; grupo 4: pneumoperitônio e dissecção da transição gastroesofágica. No momento 2 (1 semana após os procedimento cirúrgicos) foram realizados estudos eletromanométricos do esôfago em todos os animais. Resultados - Nos animais do grupo 1 (fundoplicatura laparotômica) e do grupo 3, foi observado aumento da amplitude da pressão e do comprimento do esfíncter inferior do esôfago. Naqueles dos grupos 2 e 4, não foi observada alteração da amplitude e do comprimento do esfíncter inferior do esôfago. Conclusões - A fundoplicatura interfere na barreira anti-refluxo gastroesofágica, tornando-a mais eficiente, uma vez que a pressão e o comprimento do esfíncter inferior do esôfago elevam-se no pós-operatório desta intervenção. Este efeito foi observado nas duas técnicas de abordagem estudadas, laparotômica e laparoscópica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Avaliou-se o efeito da tranquilização e da anestesia sobre os índices da eletrocardiografia de alta resolução (ECGAR) em cães portadores de doença-de-chagas na fase crônica indeterminada. Foram utilizados oito cães, adultos, sem raça definida, fêmeas, submetidas a seis protocolos (grupos). No grupo 1, os animais estavam sem efeito de tranquilização ou anestesia; no grupo 2, foram tranquilizados com acepromazina; no 3, foram tranquilizados com a associação acepromazina e buprenorfina; no 4, estavam sob anestesia geral inalatória com isofluorano; no 5, sob anestesia geral inalatória com sevofluorano; e no 6, sob anestesia com propofol. Os animais foram submetidos a todos os protocolos, com um período de 15 dias entre cada avaliação. Não se verificou alteração significativa na duração do complexo QRS e do LAS40 entre os grupos, e o RMS40 permaneceu sem alteração significativa. O nível de ruído foi significativamente menor nos grupos 4, 5 e 6 em relação ao grupo 1. A anestesia facilitou o registro da ECGAR sem alterar os índices eletrocardiográficos .

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Ação do ácido trissódio-cálcio-dietileno-triaminopentaacético (CaNa3DTPA), quelante de ferro com ação ainda anti-viral, antiinflamatória e imunológica, na atenuação de lesões de reperfusão em músculos esqueléticos de ratos. MÉTODOS: 52 ratos Wistar, pesando 188±22g, foram anestesiados e submetidos a semi-amputação de membro posterior direito (MPD), poupando-se o fêmur, artéria e veia femorais. Foram então randomizados e distribuídos: G1-CTAN - controle anestesia, sem cirurgia e sem isquemia; G2-CTCIR - controle cirurgia, sem isquemia; G3-IRCT e G3-IRDTPA - com isquemia (4 hora) e reperfusão ( 2 horas). O G3-IRCT foi tratado, ao final da isquemia, com cloreto de sódio 0,9% e G3-IRDTPA com (CaNa3DTPA).Parâmetros: Circunferência do pé direito e peso do rato, dosagem sérica de CPK, dosagem de malonaldeído e microscopia óptica de músculos soleus bilateral. RESULTADOS: Aumento da circunferência nos G3-IRCT e G3-IRDTPA (significante no G3-IRCT quando comparado ao G1-CTAN); CPK elevado nos G3-IRCT e G3-IRDTPA comparados aos controles; MDA mais alto no membro contralateral do G3-IRDTPA, comparado ao MPD do G3-IRDTPA e ao G1-CTAN; maior edema intersticial em G3-IRCT, maior infiltrado inflamatório em G3-IRDTPA e recuperação dos níveis de glicogênio semelhantes em G3-IRCT e G3-IRDTPA. CONCLUSÃO: Apesar do menor edema no G3-IRDTPA comparado ao G3-IRCT, o CaNa3DTPA não alterou CPK sérico, MDA muscular e morfologia muscular dos animais.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Analisar o efeito das fundoplicaturas total e parcial sobre a pressão e comprimento do esfíncter inferior do esôfago (EIE). MÉTODOS: Foram estudados 30 coelhos machos da raça Norfolk. Os animais foram divididos em 3 grupos de 10, na dependência da operação[cirurgia] realizada. Grupo 1 (controle)-laparotomia mediana (LM) e dissecção da transição gastroesofágica; grupo 2- LM e fundoplicatura total, e grupo 3-LM e fundoplicatura parcial. Todos os animais foram submetidos à manometria esofágica (ME) segundo a técnica de tração intermitente da sonda e infusão contínua dos cateteres com água destilada. A ME foi realizada em dois momentos: M1 (pré-operatório) e M2 (pós-operatório), e permitiu a análise da pressão (mmHg) e comprimento (cm) do EIE. RESULTADOS: Nos animais do grupo 1 não foi observada alteração da pressão e comprimento do EIE. Naqueles do grupo 2 (fundoplicatura total) foi observado aumento da pressão (69,7%) e do comprimento (81,8%) do EIE. Nos coelhos do grupo 3 (fundoplicatura parcial) houve aumento da pressão (58%) e do comprimento (100%) do EIE. CONCLUSÕES: As fundoplicaturas total e parcial acarretam aumento da pressão e comprimento de EIE. O incremento da pressão e comprimento de EIE independe do tipo de fundoplicatura utilizada.