887 resultados para Fixed bed reactors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess the impact of replacing conventional mandibular complete dentures with implant-supported fixed complete dentures (ISFDs) on the oral health related quality of life (OHOOL) of edentulous patients and on the associated kinesiographic parameters. The patients had their complete dentures replaced by ISFDs and were assessed after 1, 2, 3, 6, and 12 months. An improvement of general OHQOL was observed 2 months after treatment with ISFDs. Kinesiographic recordings revealed significant mandibular vertical and horizontal opening increases and a greater vertical intrusion of the maxillary complete dentures during clenching after the treatment with ISFD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In hospitals, health professionals may face different situations and problems. By following them, it is remarkable that one of the difficulties is related to the support provided by the facilities to carry out their work. This also affects the quality of treatment offered to patients. One of the points of improvement that could be studied is hospital beds. The Fawler's simplest hospital bed type, used in most Brazilian public hospitals, is designed with an ergonomic average height that offers a default position for analysis and treatment of patients. There is no possibility of adjusting the height of those beds, and hence there is a limitation in this regard since that height is fixed, but the physical structures of the workers and patients may vary widely and there may be a conflict when there are people too large or small involved in this process. Beyond that, studies by experts show that beds with height adjustment decreases the muscular effort and improve the movement quality of the spine of nursing staff, reducing the force on certain vertebrae and also the ergonomic risk. Of course, patient comfort is also affected accordingly. As the beds made with height adjustment are very expensive, this study aims to design a device to adapt the not adjustable beds. The project must be viable from an economic and mechanic standpoint, being able to adapt both old and new simplest Fawler hospital bed models, since their dimensions are similar. The final result shows that it is possible to adapt such beds using the designed concept at a viable cost. Furthermore, this concept could be applied in other bed types or objects that have hollow feet

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brazil has one of the largest cattle herds in the world, so the cattle slaughter is one of the most important economic activities in the Brazilian market. But this activity requires a high demand of water, resulting in serious problems about the correct disposal of wastewater generated in the process. This effluent has a high pollution load, becoming its receiving bodies (streams and rivers) unfit for various activities such as public water supply, recreation, fisheries. To minimize the environmental impacts of its industrial wastewater and fallow the local environmental legislation, refrigerators must make the treatment of these effluents. This study aimed to verify the efficiency of a enzymatic reactor, when occur hydrolysis of lipids present in the effluent industrial of an cattle slaughter industry. The treatment system used was composed of two separate reactors: one being the anaerobic fluidized bed reactor (AFBR), inoculated with immobilized enzymes on the matrix support, and the other by sequential batch reactor (SBR) inoculated with activated sludge. Whereas, the reactors have been developed and installed at the Wastewater Treatment Laboratory, Faculdade de Ciências e Tecnologia, UNESP, campus Presidente Prudente. The procedure operating occurred differently for each reactor: preparation and inoculation of enzyme granules, filling the reactor, hydrolysis, and AFBR emptying, filling, aerobic reaction, sedimentation, and emptying the SBR. We performed three experimental stages, with the first and second stage of the work were done reactor analyzes separately, and the third step of the analysis were made with the interconnected reactors... (Complete abstract electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract : The objective of this study was to evaluate quantitatively and to describe qualitatively the process of bone repair in the interface of receptor bed and graft autogenous bone block with or without a e-PTFE membrane, in osteopenia induced rats. To this end, we used forty-eight Wistar rats weighing about 300g, in which, with the aid of 4.1 mm trephine a graft was removed from the parietal bone and fixed to the surface of the left mandibular ramus. The animals were randomly divided into four experimental groups: Group 1 (n=12): SHAM operated and autogenous bone graft only; Group 2 (n=12): SHAM and autogenous bone graft covered by e-PTFE membrane; Group 3 (n=12): ovariectomized rats (OVX) and autogenous bone graft only; Group 4 (n=12): OVX and autogenous bone graft covered by e-PTFE membrane. The animals in each group were sacrificed at three time periods: 21, 45 and 60 days, each time with 4 animals per group. The specimens were decalcified and included, the sections were stained with HE and subjected to histological and histomorphometric analysis in light microscopy. The results of the ANOVA showed that the variables on the condition (OVZ and SHAM), and the time (21, 45 and 60 days) were statistically significant, and can be established with the Tukey test (5%) that the period 21-day differs significantly from the periods of 45 and 60 days, which did not differ among themselves. The descriptive histological analysis showed integration of the graft in all animals. It was concluded that the initial integration of the graft bed was negatively affected in the presence of induced osteopenia, and that the use or not of a e-PTFE membrane did not interfere in the process of integration

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Let T : M → M be a smooth involution on a closed smooth manifold and F = n j=0 F j the fixed point set of T, where F j denotes the union of those components of F having dimension j and thus n is the dimension of the component of F of largest dimension. In this paper we prove the following result, which characterizes a small codimension phenomenon: suppose that n ≥ 4 is even and F has one of the following forms: 1) F = F n ∪ F 3 ∪ F 2 ∪ {point}; 2) F = F n ∪ F 3 ∪ F 2 ; 3) F = F n ∪ F 3 ∪ {point}; or 4) F = F n ∪ F 3 . Also, suppose that the normal bundles of F n, F 3 and F 2 in M do not bound. If k denote the codimension of F n, then k ≤ 4. Further, we construct involutions showing that this bound is best possible in the cases 2) and 4), and in the cases 1) and 3) when n is of the form n = 4t, with t ≥ 1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The degradation of polychlorinated biphenyls (PCBs) was investigated under fermentativemethanogenic conditions for up to 60 days in the presence of anaerobic biomass from a full-scale UASB reactor. The low methane yields in the PCBs-spiked batch reactors suggested that the biomass had an inhibitory effect on the methanogenic community. Reactors containing PCBs and co-substrates (ethanol/ sodium formate) exhibited substantial PCB reductions from 0.7 to 0.2 mg mL-1 . For the Bacteria domain, the PCBs-spiked reactors were grouped with the PCB-free reactors with a similarity of 55 %, which suggested the selection of a specific population in the presence of PCBs. Three genera of bacteria were found exclusively in the PCB-spiked reactors and were identified using pyrosequencing analysis, Sedimentibacter, Tissierela and Fusibacter. Interestingly, the Sedimentibacter, which was previously correlated with the reductive dechlorination of PCBs, had the highest relative abundance in the RCS-PCB (7.4 %) and RCS-PCB-PF (12.4 %) reactors. Thus, the anaerobic sludge from the UASB reactor contains bacteria from the Firmicutes phylum that are capable of degrading PCBs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the method of Social Networks Analysis, we’ll try to see if politicians swap votes between them seeking support for their projects, to this end, we’ll first map the behavior, activities and contacts of the Senators of the Brazilian Federative Republic within all the fixed committees which had some vote during the 52nd Legislature, then we can see the most popular and central Senators to each committee. After this analysis we wish to answer the following question: did logrolling exist in the Brazilian Senate? Previously the empirical analysis and response to the problems posed, we’ll present the necessary theoretical introduction understood by reviewing the literature on relevant subjects, whether they are purely theoretical with respect to the exchange of support, or analytical about the Brazilian political system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oral rehabilitation of edentulous patients with immediate loading has become a safe procedure with high predictability. The success is related to immediate fabrication of a passive fit framework to attach the implants. Based on these considerations, this case report shows an alternative technique for mandibular rehabilitation using implants immediately loaded, where the framework was fabricated using cylinders with internal reinforcement and precast pieces, electrowelding, and conventional welding providing esthetics and function to the patient in a short period of time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ObjectivesThe aim of this study was to evaluate the quality of life and satisfaction of patients wearing implant-supported fixed partial dentures.Materials &methodsA total of 106 patients were selected and submitted to clinical examination and collection of the demographic data for evaluation of the implant-supported fixed dentures conditions. All participants agreed to answer to the Oral Health Impact Profile (OHIP-EDENT) questionnaire and another questionnaire about satisfaction with the implant-supported prostheses. The patients were classified into the following three groups for statistical analysis: patients wearing splinted implant-supported prosthesis (E), patients wearing single implant-supported prosthesis (U), and patients wearing single implant-supported prosthesis associated with splinted prosthesis (E+U). Kruskal-Wallis test was used to compare the answers between the groups, and a logistic regression model was measured to verify the relation between variables of the patients and the questionaries'items.ResultsThere were significant differences among groups (P=0.006) for discomfort during surgery itself of the satisfaction questionnaire. The marital status, groups, and hygiene condition were significant mainly for physical pain item.ConclusionsIt was concluded that the patients presented high level of satisfaction and quality of life for the most of the items evaluated as well as the groups showed similar results.