984 resultados para Fine Particulate Matter


Relevância:

80.00% 80.00%

Publicador:

Resumo:

With the occurrence of fossil fuels such as oil, gas and coal we found new sources of energy that have played a critical role in the progress of our modern society. Coal is very ample compared to the other two fossil fuels. Global coal reserves at the end of 2005 were estimated at 847,5 billion tones. Along with the major energy sources, coal is the most fast growing fuel on a global basis, it provides 26% of primary energy needs and remains essential to the economies of many developed and developing countries. Coal-fired power generation accounts for 41% of the world‘s total electricity production and in some countries, such as South Africa, Poland, China, Australia, Kazakhstan and India is on very high level. Still, coal utilization represents challenges related to high emissions of air pollutants such as sulphur and nitrogen dioxides, particulate matter, mercury and carbon dioxide. In relation to these a number of technologies have been developed and are in marketable use, with further potential developments towards ―Near Zero Emission‖ coal plants. In present work, coals mined in Russia and countries of Former Soviet Union were reviewed. Distribution of coal reserves on the territory of Russia and the potential for power generation from coal-fired plants across Russia was shown. Physical and chemical properties of coals produced were listed and examined, as main factor influencing on design of the combustion facility and incineration process performance. The ash-related problems in coal-fired boilers were described. The analysis of coal ash of Russia and countries of Former Soviet Union were prepared. Feasible combustion technologies also were reviewed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Brazil is doing a major effort to find alternatives to diesel oil as combustible. Some study lines are oriented to the development of vegetable oils used as fuel, as a source of getting cheaper and have higher energy density than the converted vegetable oils, and less risk of environmental contamination. The aim of this study was to evaluate the performance, the useful life of the lubricant and some components of a Diesel Cycle engine, with an electronic injection system, in a long-term test operating with a preheated blend (65°C) of 50% (v v-1) of soybean oil in petrodiesel. There was a reduction of the useful life of the injectors which presented failure because of high wear with 264 hours of operation and showed an increase in emissions of particulate matter (opacity) which may be assigned to the failures occurred in the injection system. An increase in the useful life of the lubricant, when compared with the literature was also observed. The electronic injection system may favor the burning of the tested fuel. The test was interrupted with 264 hours because of failures in the injection system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of the thesis is to study cerium oxide thin films grown by the atomic layer deposition (ALD) for soot removal. Cerium oxide is one of the most important heterogeneous catalysts and can be used in particulate filters and sensors in a diesel exhaust pipe. Its redox/oxidation properties are a key factor in soot oxidation. Thus, the cerium oxide coating can help to keep particulate filters and sensors clean permanently. The literature part of the thesis focuses on the soot removal, introducing the origin and structure of soot, reviewing emissions standards for diesel particulate matter, and presenting methods and catalysts for soot removal. In the experimental part the optimal ALD conditions for cerium oxide were found, the structural properties of cerium oxide thin films were analyzed, and the catalytic activity of the cerium oxide for soot oxidation was investigated. Studying ALD growth conditions of cerium oxide films and determining their critical thickness range are important to maximize the catalytic performance operating at comparatively low temperature. It was found that the cerium oxide film deposited at 300 °C with 2000 ALD cycles had the highest catalytic activity. Although the activity was still moderate and did not decrease the soot oxidation temperature enough for a real-life application. The cerium oxide thin film deposited at 300 °C has a different crystal structure, surface morphology and elemental composition with a higher Ce3+ concentration compared to the films deposited at lower temperatures. The different properties of the cerium oxide thin film deposited at 300 °C increase the catalytic activity most likely due to higher surface area and addition of the oxygen vacancies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The effects of short-term burst (5 min at 1.8 m/s) swimming and long-term cruiser (60 min at 1.2 m/s) swimming on maximal enzyme activities and enzyme distribution between free and bound states were assessed for nine glycolytic and associated enzymes in tissues of horse mackerel, Trachurus mediterraneus ponticus. The effects of exercise were greatest in white muscle. The activities of phosphofructokinase (PFK), pyruvate kinase (PK), fructose-1,6-bisphosphatase (FBPase), and phosphoglucomutase (PGM) all decreased to 47, 37, 37 and 67%, respectively, during 60-min exercise and all enzymes except phosphoglucoisomerase (PGI) and PGM showed a change in the extent of binding to subcellular particulate fractions during exercise. In red muscle, exercise affected the activities of PGI, FBPase, PFK, and lactate dehydrogenase (LDH) and altered percent binding of only PK and LDH. In liver, exercise increased the PK activity 2.3-fold and reduced PGI 1.7-fold only after 5 min of exercise but altered the percent binding of seven enzymes. Fewer effects were seen in brain, with changes in the activities of aldolase and PGM and in percent binding of hexokinase, PFK and PK. Changes in enzyme activities and in binding interactions with subcellular particulate matter appear to support the altered demands of tissue energy metabolism during exercise.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Type 2 diabetes increases the risk of cardiovascular mortality and these patients, even without previous myocardial infarction, run the risk of fatal coronary heart disease similar to non-diabetic patients surviving myocardial infarction. There is evidence showing that particulate matter air pollution is associated with increases in cardiopulmonary morbidity and mortality. The present study was carried out to evaluate the effect of diabetes mellitus on the association of air pollution with cardiovascular emergency room visits in a tertiary referral hospital in the city of São Paulo. Using a time-series approach, and adopting generalized linear Poisson regression models, we assessed the effect of daily variations in PM10, CO, NO2, SO2, and O3 on the daily number of emergency room visits for cardiovascular diseases in diabetic and non-diabetic patients from 2001 to 2003. A semi-parametric smoother (natural spline) was adopted to control long-term trends, linear term seasonal usage and weather variables. In this period, 45,000 cardiovascular emergency room visits were registered. The observed increase in interquartile range within the 2-day moving average of 8.0 µg/m³ SO2 was associated with 7.0% (95%CI: 4.0-11.0) and 20.0% (95%CI: 5.0-44.0) increases in cardiovascular disease emergency room visits by non-diabetic and diabetic groups, respectively. These data indicate that air pollution causes an increase of cardiovascular emergency room visits, and that diabetic patients are extremely susceptible to the adverse effects of air pollution on their health conditions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The mechanisms by which PM2.5 increases cardiovascular mortality are not fully identified. Autonomic alterations are the current main hypotheses. Our objective was to determine if PM2.5 induces acute cardiac polarization alterations in healthy Wistar rats. PM2.5 samples were collected on polycarbonate filters. Solutions containing 10, 20, and 50 µg PM2.5 were administered by tracheal instillation. P wave duration decreased significantly at 20 µg (0.99 ± 0.06, 0.95 ± 0.06, and 0.96 ± 0.07; P < 0.001), and 50 µg (0.98 ± 0.06, 0.98 ± 0.07, and 0.96 ± 0.08; 60, 90 and 120 min, respectively) compared to blank filter solution (P < 0.001). PR interval duration decreased significantly at 20 µg (0.99 ± 0.06, 0.98 ± 0.07, and 0.97 ± 0.08) and 50 µg (0.99 ± 0.05, 0.97 ± 0.0, and 0.95 ± 0.05; 60, 90, and 120 min, respectively) compared to blank filter and 10 µg (P < 0.001). QRS interval duration decreased at 20 and 50 µg in relation to blank filter solution and 10 µg (P < 0.001). QT interval duration decreased significantly (P < 0.001) with time in animals receiving 20 µg (0.94 ± 0.12, 0.88 ± 0.14, and 0.88 ± 0.11) and 50 µg (1.00 ± 0.13; 0.97 ± 0.11 and 0.98 ± 0.16; 60, 90 and 120 min, respectively) compared to blank filter solution and 10 µg (P < 0.001). PM2.5 induced reduced cardiac conduction time, within a short period, indicating that depolarization occurs more rapidly across ventricular tissue.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of the present study was to estimate the contribution of environmental pollutants to hospital admissions for cardiovascular disease. A time series ecological study was conducted on subjects aged over 60 years and living in São José dos Campos, Brazil, with a population near 700,000 inhabitants. Hospital admission data of public health patients (SUS) were obtained from DATASUS for the period between January 1, 2004 and December 31, 2006, according to the ICD-10 diagnoses I20 to I22 and I24. Particulate matter with less than 10 µm in aerodynamic diameter, sulfur dioxide and ozone were the pollutants examined, and the control variables were mean temperature and relative humidity. Data on pollutants were obtained from the São Paulo State Sanitary Agency. The generalized linear model Poisson regression with lags of up to 5 days was used. There were 1303 hospital admissions during the period. Exposure to particulate matter was significantly associated with hospitalization for cardiovascular disease 3 days after exposure (RR = 1.006; 95%CI = 1.000 to 1.010) and an increase of 16 µg/m³ was associated with a 10% increase in risk of hospitalization; other pollutants were not associated with hospitalization. Thus, it was possible to identify the role of exposure to particulate matter as an environmental pollutant in hospitalization for cardiovascular disease in a medium-sized city inSoutheastern Brazil.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

There is a demonstrable association between exposure to air pollutants and deaths due to cardiovascular diseases. The objective of this study was to estimate the effects of exposure to sulfur dioxide on mortality due to circulatory diseases in individuals 50 years of age or older residing in São José dos Campos, SP. This was a time-series ecological study for the years 2003 to 2007 using information on deaths due to circulatory disease obtained from Datasus reports. Data on daily levels of pollutants, particulate matter, sulfur dioxide (SO2), ozone, temperature, and humidity were obtained from the São Paulo State Environmental Agency. Moving average models for 2 to 7 days were calculated by Poisson regression using the R software. Exposure to SO2 was analyzed using a unipollutant, bipollutant or multipollutant model adjusted for mean temperature and humidity. The relative risks with 95%CI were obtained and the percent decrease in risk was calculated. There were 1928 deaths with a daily mean (± SD) of 1.05 ± 1.03 (range: 0-6). Exposure to SO2 was significantly associated with mortality due to circulatory disease: RR = 1.04 (95%CI = 1.01 to 1.06) in the 7-day moving average, after adjusting for ozone. There was an 8.5% decrease in risk in the multipollutant model, proportional to a decrease of SO2 concentrations. The results of this study suggest that residents of medium-sized Brazilian cities with characteristics similar to those of São José dos Campos probably have health problems due to exposure to air pollutants.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Exposure to air pollutants is associated with hospitalizations due to pneumonia in children. We hypothesized the length of hospitalization due to pneumonia may be dependent on air pollutant concentrations. Therefore, we built a computational model using fuzzy logic tools to predict the mean time of hospitalization due to pneumonia in children living in São José dos Campos, SP, Brazil. The model was built with four inputs related to pollutant concentrations and effective temperature, and the output was related to the mean length of hospitalization. Each input had two membership functions and the output had four membership functions, generating 16 rules. The model was validated against real data, and a receiver operating characteristic (ROC) curve was constructed to evaluate model performance. The values predicted by the model were significantly correlated with real data. Sulfur dioxide and particulate matter significantly predicted the mean length of hospitalization in lags 0, 1, and 2. This model can contribute to the care provided to children with pneumonia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Few studies evaluate the amount of particulate matter less than 2.5 mm in diameter (PM2.5) in relation to a change in lung function among adults in a population. The aim of this study was to assess the association of coal as a domestic energy source to pulmonary function in an adult population in inner-city areas of Zunyi city in China where coal use is common. In a cross-sectional study of 104 households, pulmonary function measurements were assessed and compared in 110 coal users and 121 non-coal users (≥18 years old) who were all nonsmokers. Several sociodemographic factors were assessed by questionnaire, and ventilatory function measurements including forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), the FEV1/FVC ratio, and peak expiratory flow rate (PEFR) were compared between the 2 groups. The amount of PM2.5 was also measured in all residences. There was a significant increase in the relative concentration of PM2.5 in the indoor kitchens and living rooms of the coal-exposed group compared to the non-coal-exposed group. In multivariate analysis, current exposure to coal smoke was associated with a 31.7% decrease in FVC, a 42.0% decrease in FEV1, a 7.46% decrease in the FEV1/FVC ratio, and a 23.1% decrease in PEFR in adult residents. The slope of lung function decrease for Chinese adults is approximately a 2-L decrease in FVC, a 3-L decrease in FEV1, and an 8 L/s decrease in PEFR per count per minute of PM2.5 exposure. These results demonstrate the harmful effects of indoor air pollution from coal smoke on the lung function of adult residents and emphasize the need for public health efforts to decrease exposure to coal smoke.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Exposure to nitrogen oxides (NOx) emitted by burning fossil fuels has been associated with respiratory diseases. We aimed to estimate the effects of NOx exposure on mortality owing to respiratory diseases in residents of Taubaté, São Paulo, Brazil, of all ages and both sexes. This time-series ecological study from August 1, 2011 to July 31, 2012 used information on deaths caused by respiratory diseases obtained from the Health Department of Taubaté. Estimated daily levels of pollutants (NOx, particulate matter, ozone, carbon monoxide) were obtained from the Centro de Previsão de Tempo e Estudos Climáticos Coupled Aerosol and Tracer Transport model to the Brazilian developments on the Regional Atmospheric Modeling System. These environmental variables were used to adjust the multipollutant model for apparent temperature. To estimate association between hospitalizations owing to asthma and air pollutants, generalized additive Poisson regression models were developed, with lags as much as 5 days. There were 385 deaths with a daily mean (±SD) of 1.05±1.03 (range: 0-5). Exposure to NOx was significantly associated with mortality owing to respiratory diseases: relative risk (RR)=1.035 (95% confidence interval [CI]: 1.008-1.063) for lag 2, RR=1.064 (95%CI: 1.017-1.112) lag 3, RR=1.055 (95%CI: 1.025-1.085) lag 4, and RR=1.042 (95%CI: 1.010-1.076) lag 5. A 3 µg/m3 reduction in NOx concentration resulted in a decrease of 10-18 percentage points in risk of death caused by respiratory diseases. Even at NOx concentrations below the acceptable standard, there is association with deaths caused by respiratory diseases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Several automated reversed-phase HPLC methods have been developed to determine trace concentrations of carbamate pesticides (which are of concern in Ontario environmental samples) in water by utilizing two solid sorbent extraction techniques. One of the methods is known as on-line pre-concentration'. This technique involves passing 100 milliliters of sample water through a 3 cm pre-column, packed with 5 micron ODS sorbent, at flow rates varying from 5-10 mUmin. By the use of a valve apparatus, the HPLC system is then switched to a gradient mobile phase program consisting of acetonitrile and water. The analytes, Propoxur, Carbofuran, Carbaryl, Propham, Captan, Chloropropham, Barban, and Butylate, which are pre-concentrated on the pre-column, are eluted and separated on a 25 cm C-8 analytical column and determined by UV absorption at 220 nm. The total analytical time is 60 minutes, and the pre-column can be used repeatedly for the analysis of as many as thirty samples. The method is highly sensitive as 100 percent of the analytes present in the sample can be injected into the HPLC. No breakthrough of any of the analytes was observed and the minimum detectable concentrations range from 10 to 480 ng/L. The developed method is totally automated for the analysis of one sample. When the above mobile phase is modified with a buffer solution, Aminocarb, Benomyl, and its degradation product, MBC, can also be detected along with the above pesticides with baseline resolution for all of the analytes. The method can also be easily modified to determine Benomyl and MBC both as solute and as particulate matter. By using a commercially available solid phase extraction cartridge, in lieu of a pre-column, for the extraction and concentration of analytes, a completely automated method has been developed with the aid of the Waters Millilab Workstation. Sample water is loaded at 10 mL/min through a cartridge and the concentrated analytes are eluted from the sorbent with acetonitrile. The resulting eluate is blown-down under nitrogen, made up to volume with water, and injected into the HPLC. The total analytical time is 90 minutes. Fifty percent of the analytes present in the sample can be injected into the HPLC, and recoveries for the above eight pesticides ranged from 84 to 93 percent. The minimum detectable concentrations range from 20 to 960 ng/L. The developed method is totally automated for the analysis of up to thirty consecutive samples. The method has proven to be applicable to both purer water samples as well as untreated lake water samples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Douze contaminants émergents (composés pharmaceutiques, pesticides et hormones) ont été quantifiés et extraits de l'eau de rivières et d’échantillons d'eaux usées municipales. La séparation des solides en suspension est effectuée par filtration des échantillons d'eau. L'effet de filtration sur les concentrations de contaminants dissous a été évaluée afin de minimiser les pertes de composés cibles. Les échantillons ont été lyophilisés et ont été extraits en deux cycles par ultrasons combinés avec une étape de nettoyage sur cartouche d’extraction de type C18. La quantification a été réalisée en utilisant la spectrométrie de masse. Les recouvrements de la méthode pour tous les composés ont varié de 68 à 112% dans toutes les matrices étudiées, sauf pour le sulfaméthoxazole et le diclofénac où des recouvrements plus modestes ont été obtenus (38 à 85%). Les limites de détection pour les 12 analytes dans les sédiments et particules en suspension (SPM) de la rivière variaient de 0,7 à 9,4 ng g-1 et de 21 à 92 ng g-1, pour les échantillons SPM de station d'épuration. Tous les contaminants émergents cibles ont été détectés à des concentrations variant de 3 à 5440 ng g-1 dans les matrices étudiées, les concentrations les plus élevées ont été observées dans les échantillons SPM de stations d'épuration. Une partie importante de certains de ces contaminants est clairement associée aux sédiments de rivière ou aux particules en suspension. L’optimisation des processus de traitement de l'eau et le devenir environnemental doit absolument tenir compte de la fraction de contaminants qui liée à des particules si on espère avoir un bilan de masse raisonnable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La majorité des études qui ont examiné les effets respiratoires d’une exposition de courte durée à la pollution de l’air ont été réalisées en milieu urbain. En milieu pollué par des sources industrielles, la nature de l’exposition diffère de celle en milieu urbain. Le premier objectif de ce mémoire visait une recension des études traitant de l’association entre les effets respiratoires chez l’enfant et l’exposition aux émissions de polluants industriels. La majorité des études suggèrent que l’exposition aux émissions de polluants émis par des industries est associée à un accroissement des problèmes respiratoires. Dans ces études, l’effet de l’exposition de courte durée a rarement été étudié. L’autre objectif du mémoire était d’évaluer l’association entre une exposition journalière aux émissions de pollution atmosphérique d’un complexe industriel (deux fonderies et une usine de raffinage de l’alumine) du Saguenay, Québec, et les hospitalisations pour problèmes respiratoires des enfants de 0 à 4 ans vivant près de celles-ci (<7.5 km), à l’aide d’une étude épidémiologique de type cas-croisé. Le pourcentage d’heures où le domicile de l’enfant était sous les vents provenant de la direction du complexe industriel et les maxima et moyennes journalières des concentrations de dioxyde de soufre (SO2) et de particules fines (PM2.5) ont été recueillis du 1er janvier 2001 au 31 décembre 2010 afin d’estimer l’exposition. Des régressions logistiques conditionnelles ont été employées pour estimer les rapports de cotes (OR) et les intervalles de confiance à 95%. Les hospitalisations pour asthme et bronchiolite chez les jeunes enfants étaient associées à l’augmentation de l’exposition journalière aux émissions, estimée par le pourcentage d’heures sous les vents. Les résultats de ce mémoire suggèrent que l’exposition aux émissions industrielles de polluants de l’air est associée à des effets respiratoires chez les enfants.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study was aimed at to characterize the spatio-temporal trends in the distributional characteristics of various species of nitrogen and phosphorus as well as to elucidate the factors and processes aflecting these nutrients in the dissolved, particulate and sedimentary phases of a river estuarine system. The main area of study is Chalakudy river in Kerala, which is a fresh water system originating from Anamalai hills and ending at Arabian Sea. Its basin is between I00 05 ’ to I00 35’ North latitude and 76” 15 ’ to 760 55’ East longitude. Being a riparian bufler zone, the dynamics of nutrient mobility tend to be more complex and variable in this river-estuarine system.The diflerent species of nitrogen estimated from the filtrate were nitrite-N, nitrateN, ammonia-N, urea-N, total nitrogen and residual nitrogen. The diflerent forms of phosphorus estimated from the filtrate were phosphate-P, total-P and residualP. Pre weighed sediments as well as particulate matter were analysed for quantijying nitrite-N, nitrate-N, ammonia-N and urea-N. Total nitrogen was estimated after digestion with potassium persulfate. Fractionation of phosphorus in sediment/particulate matter was performed by applying sequential extraction procedure. The dijferent forms of phosphorus thus estimated were loosely bound (exchangeable) P, Fe/Al bound P, polyphosphates, Ca bound P and refractory P. Sedimental total P was also measured directly by applying digestion method.The analyses carried out in this bimonthly annual survey have revealed specific information on the latent factors influencing the water quality pattern ofthe river. There was dependence among the chemical components of the river sediment and suspended matter, reflecting the water quality. A period of profound environmental change occurred and changes in various species had been noted in association with seasonal variations in the waterway, especially following enhanced river runoff during the monsoon. The results also successfully represented the distribution trend of nutrients during the rainy as well as dry season. Thus, the information gathered in this work will also be beneficial for those interested or involved in river management, conservation, regulation and policy making in regional and national levels.