994 resultados para Enzyme kinetic
KINETIC-STUDY OF THE OXIDATION OF WATER BY CE-4 IONS MEDIATED BY ACTIVATED RUTHENIUM DIOXIDE HYDRATE
Resumo:
Efficient control of the illegal use of anabolic steroids must both take into account metabolic patterns and associated kinetics of elimination; in this context, an extensive animal experiment involving 24 calves and consisting of three administrations of 17 beta-estradiol 3-benzoate and 17 beta-nandrolone laureate esters was carried out over 50 days. Urine samples were regularly collected during the experiment from all treated and non-treated calves. For sample preparation, a single step high throughput protocol based on 96-well C-18 SPE was developed and validated according to the European Decision 2002/657/EC requirements. Decision limits (CC alpha) for steroids were below 0.1 mu g L-1, except for 19-norandrosterone (CC alpha = 0.7 mu g L-1) and estrone (CC alpha = 0.3 mu g L-1). Kinetics of elimination of the administered 17 beta-estradiol 3-benzoate and 17 beta-nandrolone laureate were established by monitoring 17 beta-estradiol, 17 alpha-estradiol, estrone and 17 beta-nandrolone, 17 alpha-nandrolone, 19-noretiocholanolone, 19-norandrostenedione, respectively. All animals demonstrated homogeneous patterns of elimination both from a qualitative (metabolite profile) and quantitative point of view (elimination kinetics in urine). Most abundant metabolites were 17 alpha-estradiol and 17 alpha-nandrolone (> 20 and 2 mg L-1, respectively after 17 beta-estradiol 3-benzoate and 17 beta-nandrolone laureate administration) whereas 17 beta-estradiol, estrone, 17 beta-nandrolone, 19-noretiocholanolone and 19-norandrostenedione were found as secondary metabolites at concentration values up to the mu g L-1 level. No significant difference was observed between male and female animals. The effect of several consecutive injections on elimination profiles was studied and revealed a tendency toward a decrease in the biotransformation of administered steroid 17 beta form. (c) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Semicarbazide (SEM), the marker residue for the banned nitrofuran veterinary antibiotic nitrofurazone (NFZ), has been detected regularly in foods (47% of recent nitrofuran EU Rapid Alerts involve SEM). However, the validity of SEM as a definitive marker for NFZ has been undermined by SEM arising from other sources including azodicarbonamide, a plastics blowing agent and flour treatment additive. An inexpensive screening test for SEM in food matrices is needed-all SEM testing currently uses expensive LC-MS/MS instrumentation. We now report the first production of antibodies against derivatised SEM. A novel carboxyphenyl SEM derivative was used to raise a polyclonal antibody that has been incorporated into a semi-quantitative microtitre plate ELISA, validated according to the criteria set out in Commission Decision 2002/657/EC, for use with chicken muscle. The antibody is highly specific for derivatised SEM, cross-reactivity being 1.7% with NFZ and negligible with a wide range of other nitrofurans and poultry drugs. Samples are derivatised with o-nitrobenzaldehyde and simultaneously protease digested before extraction by cation exchange SPE. The ELISA has a SEM detection capability (CC beta) of 0.25 mu g kg(-1) when a threshold of 0.21 mu g kg(-1) is applied to the selection of samples for confirmation (lowest observed 0.25 mu g kg(-1) fortified sample, n = 20), thus satisfying the EU nitrofurans' minimum required performance limit of 1 mu g kg(-1). N-FZ-incurred muscles (12) containing SEM at 0.5-5.0 mu g kg(-1) by LC-MS/MS, all screened positive by this ELISA protocol which is also applicable to egg and chicken liver. (C) 2007 Elsevier BN. All rights reserved.
Resumo:
Furazolidone, a nitrofuran antibiotic, is banned from use in food animal production within the European Union. Increasingly, compliance with this ban is monitored by use of analytical methods to detect a stable tissue-bound metabolite, 3-amino-2-oxazolidinone (AOZ). Widespread use of furazolidone in poultry and prawns imported into Europe highlighted the urgent need for development of nitrofuran immunoassay screening tests. The first enzyme-linked immunoabsorbant assay for detection of AOZ residues in prawns (shrimps) is now described. Prawn samples were derivatized with o-nitrobenzaldehyde, extracted into ethyl acetate, washed with hexane and applied to a competitive enzyme immunoassay based on a rabbit polyclonal antiserum. Assay limit of detection (LOD) (mean+3 s) calculated from the analysis of 20 known negative cold and warm water prawn samples was 0.1 mug kg(-1). Intra- and interassay relative standard deviations were determined as 18.8 and 38.2%, respectively, using a negative prawn fortified at 0.7 mug kg(-1). The detection capability (CCbeta), defined as the concentration of AOZ at which 20 different fortified samples yielded results above the LOD, was achieved at fortification between 0.4 and 0.7 mug kg(-1). Incurred prawn samples (n=8) confirmed by liquid chromatography coupled with tandem mass spectrometry detection to contain AOZ concentrations between 0.4 and 12.7 mug kg(-1) were all screened positive by this enzyme-linked immunoabsorbant assay. Further data are presented and discussed with regard to calculating assay LOD based on accepting a 5% false-positive rate with representative negative prawn samples. Such an acceptance improves the sensitivity of an ELISA and in this case permitted an LOD of 0.05 mug kg(-1) and a CCbeta of below 0.4 mug kg(-1).
Resumo:
The means to detect the irradiation of food has been investigated for many years. In recent times radiolytic products, termed 2-alkylcyclobutanones (2-CBs), have been identified as excellent markers of irradiation in lipid-containing foods. An ELISA test was developed, which was capable of detecting a number of these compounds in irradiated chicken meat. A polyclonal antiserum was raised to a 2-CB containing a terminal carboxyl group conjugated to a carrier protein. This antiserum was highly specific for cyclobutanones containing C-10 and C-12 side chains. During assay validation the limit of detection of the assay was calculated to be 0.064 pg of 2-CB per gram of fat, within- and between-assay variations ranged from 6.7 to 18%. During experimental studies, chicken meat irradiated at doses ranging from 2.5 to 10 kGy were assayed and correctly identified as being treated. Quantitative comparisons between the ELISA and CC-MS revealed a good correlation (r(2) = 0.913) between the two methodologies in concentrations of 2-CB detected in irradiated samples.
Resumo:
Monensin, a carboxylic acid ionophore, is commonly fed to poultry to control coccidiosis. A method for the detection and quantification of monensin residues in liver has been developed, Samples (3 g) were extracted with acetonitrile-water and applied to a competitive enzyme immunoassay using a polyclonal antiserum raised against a monensin-transferrin conjugate, The limit of detection (mean + 3s) calculated from the analysis of 12 known negative samples was 2.91 ng g(-1). Intra- and inter-assay RSD were determined as 8.5 and 10.6%, respectively, using a liver sample fortified with 20 ng g(-1) monensin, A pharmacokinetic study in which 70 six week old broilers were fed monensin at a rate of 120 mg kg(-1) in their feed for 14 d resulted in mean monensin liver residues of 102 ng g(-1). However these had fallen below the limit of detection of the assay within the 3 d withdrawal period recommended by the manufacturer.
Resumo:
Ivermectin, a member of the avermectin group, is frequently used to control parasites in many food producing animal species. A method for the detection and quantification of ivermectin residues in bovine liver has been developed. Liver samples (4 g) were extracted with acetonitrile and applied to a competitive enzyme immunoassay using a polyclonal antiserum raised in rabbits against an ivermectin-transferrin conjugate, The limit of detection of the assay (mean +/- 3s) calculated from the analysis of 24 known negative samples was 1.6 ng g(-1), Intra- and inter-assay RSDs were determined as 8.8 and 14.6%, respectively, using a negative bovine liver sample fortified with 100 ng g(-1) of ivermectin. Four Friesian steers were treated with a pour-on application of ivermectin at a dose rate of 0.5 mg kg(-1) body mass then withdrawn and killed at 7, 14, 21 and 28 d, Livers mere removed and ivermectin residue concentrations determined using the proposed immunoassay procedure, Seven days post-treatment the ivermectin liver concentration was determined as 52.7 ng g(-1), decreasing to 4.1 ng(-1) at 28 d, All immunoassay results were confirmed using high-performance liquid chromatography (HPLC), The immunoassay and HPLC results for invermectin ranged from 1 to 58 ng g(-1) and were in close correlation (r = 0.99).
Resumo:
A new competitive enzyme immunoassay technique has been developed for the determination of concentrations of the trypanocidal drug isometamidium chloride (Samorin) in bovine serum. The method has been shown to be highly repeatable and reproducible, and it has several advantages over previous immunoassay techniques for the drug. There are fewer incubation steps overall; microtitre plates may be of coated in batches and stored frozen for future use; and the competition incubation is overnight and is followed only by a brief colour development stage of 10 min. Coefficients of variation (CVs) of duplicate samples were similar to 5%, and mean response variances of untreated cattle (n = 57) were small (CV, 10%). Partitioning of variance showed 77% of this variability to be intrinsic to the samples, and the remaining 23% was due to the procedure. The limit of detection was approximately 0.5 ng ml(-1), which was considered to be satisfactory for the intended use of the method. The drug could be detected in serum of treated cattle for up to 10 weeks following treatment, and determinations showed a high level of reproducibility.
Resumo:
The performance of three conventional enzyme and radioimmunoassays routinely used to detect residues of anabolic steroids in cattle sera were compared with dissociation enhanced lanthanide fluorescence immunoassay (DELFIA) kits designed for the hospital market. Slight modifications to the kit reagents were required for the analysis of bovine sera. Owing to the large sample volumes used in conventional assays, detection limits were generally better than those obtained with DELFIA kits, however, assay reproducibility was enhanced using the DELFIA technology. Comparison of sera obtained from cattle implanted with anabolic steroids revealed a good correlation between alternate methods (r(2) from 0.91 to 0.97). The DELFIA kits offer a faster method for measuring estradiol, progesterone and testosterone with adequate sensitivity and in a safer environment than that encountered using radioimmunoassays.
Resumo:
Objective: To investigate the association between angiotensin-converting enzyme inhibitors (ACEIs) and angiotensin receptor blockers (ARBs) and disease progression and survival in cancer patients.
Methods: Using terms for cancer and ACEIs/ARBs, MEDLINE, EMBASE and Web of Science were systematically searched for observational/interventional studies that used clinically relevant outcomes for cancer progression and survival.
Results: Ten studies met the inclusion criteria. Two studies showed a significant improvement in overall survival (OS) with ACEI/ARB use among patients with advanced pancreatic (HR 0.52, 95% CI 0.29–0.88) and non-small cell lung cancer (HR 0.56, 95% CI 0.33–0.95). An improvement in progression-free survival (PFS) was also reported for pancreatic cancer patients (HR 0.58, 95% CI 0.34–0.95) and patients with renal cell carcinoma (HR 0.54, p = 0.02). ACEI/ARB use was protective against breast cancer recurrence (HR 0.60, 95% CI 0.37–0.96), colorectal cancer distant metastasis (OR 0.22, 95% CI 0.08–0.65) and prostate specific antigen (PSA) failure in prostate cancer patients (p = 0.034). One study observed a worse OS (HR 2.01, 95% CI 1.00–4.05) and PFS in ACEI users with multiple myeloma (p = 0.085) while another reported an increased risk of breast cancer recurrence (HR = 1.56, 95% CI 1.02–2.39).
Conclusion: There is some evidence to suggest that ACEI or ARB use may be associated with improved outcomes in cancer patients. Larger, more robust studies are required to explore this relationship further.
Resumo:
The chromium bearing wastewater in this study was used to simulate the low concentration discharge from a major aerospace manufacturing facility in the UK. Removal of chromium ions from aqueous solutions using raw dolomite was achieved using batch adsorption experiments. The effect of; initial Cr(VI) concentration, amount of adsorbent, solution temperature, dolomite particle size and shaking speed was studied. Maximum chromium removal was found at pH 2.0. A kinetic study yielded an optimum equilibrium time of 96 h with an adsorbent dose of 1 g/L Sorption studies were conducted over a concentration range of 5-50 mg/L Cr(VI) removal decreased with an increase in temperature (q(max): 20 degrees C = 10.01 mg/g; 30 degrees C = 8.385 mg/g; 40 degrees C = 6.654 mg/g; and 60 degrees C = 5.669 mg/g). Results suggest that the equilibrium adsorption was described by the Freundlich model. The kinetic processes of Cr(VI) adsorption onto dolomite were described in order to provide a more clear interpretation of the adsorption rate and uptake mechanism. The overall kinetic data was acceptably explained by a pseudo first-order rate model. Evaluated Delta G degrees and Delta H degrees specify the spontaneous and exothermic nature of the reaction. The adsorption takes place with a decrease in entropy (Delta S degrees is negative). (C) 2011 Elsevier B.V. All rights reserved.