920 resultados para Dispute settlement procedure
Resumo:
Transcatheter aortic valve implantation (TAVI) for the treatment of symptomatic severe aortic stenosis has emerged as an effective treatment for high risk patients. In 2002 TAVI was performed for the first time in a human by Alain Cribier, using an antegrade access approach via the femoral vein, crossing the intra-atrial septum after puncture and passing the native aortic valve in the direction of blood flow. This technically demanding approach was subsequently replaced by retrograde transfemoral arterial access. For patients with severe peripheral vascular disease or inadequately sized femoral arteries, the transapical route provides an alternative route with antegrade access to the aortic valve via puncture of the anterolateral wall of the left ventricle. The transsubclavian access approach using most frequently the left subclavian artery and direct transaortic access have been introduced more recently and attest to the versatility of TAVI in terms of access site. This article will focus on the different access site options available to operators, provide a step-by-step guide through the procedure, and a detailed description of the technological evolution of transcatheter heart valve systems.
Resumo:
The expansion of agriculture in the Near East during the middle Holocene significantly altered the physical landscape. However, the relationship between the scale of agriculture and the magnitude and timing of the environmental impacts is not well known. The Gordion Regional Survey provides a novel dataset to compare settlement density during archaeological periods to rates of environmental disruption. Sediment samples from alluvial cores directly date the environmental disruption, which can be matched to period-specific settlement intensities in the watershed as constructed from archaeological survey ceramics. Degradation rates rose sharply within a millennium of the earliest Chalcolithic occupation. Early Bronze Age (EBA) land use induced the greatest rates of environmental degradation, although settlement density was relatively low on the landscape. The degradation rate subsequently decreased to one-third its early peak by the Iron Age, even as settlement intensity climbed. This trajectory reveals how complex interaction effects can amplify or subdue the responses of the landscape-land use system. Prior to settlement, landscape soil reservoirs were highly vulnerable, easily tipped by early agricultural expansion. Subsequent reduced rates of erosion are tied both to changes in sociopolitical organization and to depletion of the vulnerable soil supply.
Resumo:
The value of the sentinel lymph node (SLN) procedure in colon cancer patients remains a matter of debate. The objective of this prospective, multicenter trial was 3-fold: to determine the identification rate and accuracy of the SLN procedure in patients with resectable colon cancer; to evaluate the learning curve of the SLN procedure; and to assess the extent of upstaging due to the SLN procedure.
Resumo:
BACKGROUND: The rigorous test to which homeopathy was subject in our recent double-blind clinical trail of homeopathic treatment of attention deficit hyperactivity disorder (ADHD) necessitated optimized treatment meeting the highest standards. METHODS: Optimization was performed in three steps: (1) In successfully treated children, prescriptions leading to an insufficient response were analysed by a general questionnaire to identify unreliable symptoms. (2) Polarity analysis, a further development of Bönninghausen's concept of contraindications, was introduced in response to the frequently one-sided symptoms. This enabled us to use few but specific symptoms to identify the medicine whose genius symptoms exhibit the closest match to the patient's characteristic symptoms. (3) We investigated the influence of the primary perception symptoms on the result of the repertorization. Perception symptoms are not normally recorded during a patient interview even though they are among the most reliable facts related by the patients. At the same time we were able to improve the continuity of improvement of ADHD symptoms using liquid Q-potencies. RESULTS: Introducing the questionnaire, polarity analysis, and including perception symptoms, lead to an improvement in the success rate of the first prescription from 21% to 54%, of the fifth prescription from 68% to 84%.
Nonparametric Inference Procedure For Percentiles of the Random Effect Distribution in Meta Analysis
Resumo:
BACKGROUND: Treatment of patients with attention deficit hyperactivity disorder (ADHD) with homeopathy is difficult. The Swiss randomised, placebo controlled, cross-over trial in ADHD patients (Swiss ADHD trial) was designed with an open-label screening phase prior to the randomised controlled phase. During the screening phase, the response of each child to successive homeopathic medications was observed until the optimal medication was identified. Only children who reached a predefined level of improvement participated in the randomised, cross-over phase. Although the randomised phase revealed a significant beneficial effect of homeopathy, the cross-over caused a strong carryover effect diminishing the apparent difference between placebo and verum treatment. METHODS: This retrospective analysis explores the screening phase data with respect to the risk of failure to demonstrate a specific effect of a randomised controlled trial (RCT) with randomisation at the start of the treatment. RESULTS: During the screening phase, 84% (70/83) of the children responded to treatment and reached eligibility for the randomised trial after a median time of 5 months (range 1-18), with a median of 3 different medications (range 1-9). Thirteen children (16%) did not reach eligibility. Five months after treatment start, the difference in Conners Global Index (CGI) rating between responders and non-responders became highly significant (p = 0.0006). Improvement in CGI was much greater following the identification of the optimal medication than in the preceding suboptimal treatment period (p < 0.0001). CONCLUSIONS: Because of the necessity of identifying an optimal medication before response to treatment can be expected, randomisation at the start of treatment in an RCT of homeopathy in ADHD children has a high risk of failure to demonstrate a specific treatment effect, if the observation time is shorter than 12 months.
Resumo:
Pulmonary embolism is very rarely reported early after cardiac surgery, most probably due to full heparinisation during cardiopulmonary bypass. We report a 66-year-old man without thromboembolic history who presented three days after a coronary artery bypass grafting procedure with acute dyspnoea and haemodynamic instability. A CT scan confirmed paracentral bilateral pulmonary embolism requiring an urgent and successful embolectomy. Review of the literature confirms that pulmonary embolism may occur in up to 3% of post-cardiopulmonary bypass patients. The possibility of pulmonary embolism must be taken into consideration in post-cardiopulmonary bypass patients with acute onset of chest pain and respiratory insufficiency.
Resumo:
Percutaneous valve replacement for severe aortic stenosis has shown to be an alternative treatment option for non-surgical candidates. We report on the first successful valve in valve procedure in an 80-year-old patient with a severe regurgitation of a degenerated aortic bioprosthesis using the Corevalve Revalving system.
Resumo:
OBJECTIVE: The Ross operation remains a controversially discussed procedure, because concern exists regarding late dilatation of the neoaortic root and progressive regurgitation of the autograft valve. We present our early experience with an external reinforcement of the autograft, which is inserted into a prosthetic Dacron graft with an artificial aortic root configuration. This detail should help to prevent neoaortic root dilatation. PATIENTS AND METHODS: Between 2006 and 2007, 12 patients (mean age 16 +/- 38 years; range 15-38 years) underwent a Ross procedure by this technique. Indications were aortic regurgitation (n = 2), aortic stenosis (n = 5), and combined aortic stenosis and insufficiency (n = 5). A bicuspid aortic valve was present in 9 patients. Balloon valvuloplasty had been performed in 7 patients. Follow-up was performed by clinical and echocardiographic examinations. RESULTS: No early or late deaths occurred in this small series, and freedom from reoperation is 100%. Echocardiographic follow-up confirmed absence of aortic insufficiency in 11 patients after a mean of 11 months (range 2-30 months). In 1 patient, a small asymmetric regurgitation jet was already observed at discharge echocardiography. As expected, no neoaortic root dilatation was observed during follow-up. All patients are in New York Heart Association class I. CONCLUSIONS: The present technique is a simple and reproducible technical step that does not require significant additional time. Inclusion of the autograft within a root prosthesis may be especially indicated in situations known for late autograft dilatation, namely, bicuspid aortic valve, predominant aortic insufficiency, and ascending aortic enlargement.
Resumo:
For the past sixty years, waveguide slot radiator arrays have played a critical role in microwave radar and communication systems. They feature a well-characterized antenna element capable of direct integration into a low-loss feed structure with highly developed and inexpensive manufacturing processes. Waveguide slot radiators comprise some of the highest performance—in terms of side-lobe-level, efficiency, etc. — antenna arrays ever constructed. A wealth of information is available in the open literature regarding design procedures for linearly polarized waveguide slots. By contrast, despite their presence in some of the earliest published reports, little has been presented to date on array designs for circularly polarized (CP) waveguide slots. Moreover, that which has been presented features a classic traveling wave, efficiency-reducing beam tilt. This work proposes a unique CP waveguide slot architecture which mitigates these problems and a thorough design procedure employing widely available, modern computational tools. The proposed array topology features simultaneous dual-CP operation with grating-lobe-free, broadside radiation, high aperture efficiency, and good return loss. A traditional X-Slot CP element is employed with the inclusion of a slow wave structure passive phase shifter to ensure broadside radiation without the need for performance-limiting dielectric loading. It is anticipated this technology will be advantageous for upcoming polarimetric radar and Ka-band SatCom systems. The presented design methodology represents a philosophical shift away from traditional waveguide slot radiator design practices. Rather than providing design curves and/or analytical expressions for equivalent circuit models, simple first-order design rules – generated via parametric studies — are presented with the understanding that device optimization and design will be carried out computationally. A unit-cell, S-parameter based approach provides a sufficient reduction of complexity to permit efficient, accurate device design with attention to realistic, application-specific mechanical tolerances. A transparent, start-to-finish example of the design procedure for a linear sub-array at X-Band is presented. Both unit cell and array performance is calculated via finite element method simulations. Results are confirmed via good agreement with finite difference, time domain calculations. Array performance exhibiting grating-lobe-free, broadside-scanned, dual-CP radiation with better than 20 dB return loss and over 75% aperture efficiency is presented.