923 resultados para Diode parameters
Resumo:
An experiment was carried out to establish mean bone quality values of the tibiae and femora of ostriches and to evaluate these bones. The right leg bones of 10 males and 10 female African Black ostriches were evaluated. Birds were radiographed immediately after slaughter (during bleeding), with the aid of a portable X-ray apparatus. The obtained radiographs were scanned and bone mineral density means were obtained using software. Bone strength, Seedor index, and dry matter percentage were evaluated and correlated to weight gain during the finishing period (3-13 months of age). Mean values of the evaluated bone quality traits, not previously found in literature, were established. There were no significant differences between males and females in performance or bone quality parameters. It was concluded that male and female ostriches present similar performance and bone quality at slaughter age.
Resumo:
Two experiments evaluated milk production, serum progesterone and insulin, and reproductive performance of lactating Holstein cows receiving or not receiving Ca salts of polyunsaturated fatty acids (PUFA), or receiving Ca salts of PUFA at different daily frequencies. In experiment 1, 1,125 cows randomly distributed in 10 freestall barns were enrolled. Barns were assigned randomly to receive a high-concentrate diet containing (PI?) or not containing (control, CON) 1.1% (dry matter basis) Ca salts of PUPA. Diets were offered 6 times daily, whereas the Ca salts of PUFA were included in the PF treatment in the first feeding of the day. In experiment 2, 1,572 cows were randomly distributed in 10 freestall barns, which were assigned randomly to receive a diet similar to PF, but with Ca salts of PUFA included only in the first feeding of the day (PF1X), or equally distributed across all 6 feedings (PF6X). During both experiments, cows were artificially inseminated 12 h after the onset of estrus. Once per month, cows that did not conceive to artificial insemination were assigned to a fixed-time embryo transfer protocol. Pregnancy was determined via transrectal ultrasonography 28 and 60 d after expected ovulation. Pregnancy loss was considered in cows that were pregnant on d 28 but nonpregnant on d 60. During both experiments, feed intake, milk yield, and milk protein and fat content were recorded weekly. Blood samples were collected concurrently with embryo transfer. During experiment 1, feed intake was similar between treatments. Compared with CON, PF cows had greater milk yield (37.8 vs. 35.3 kg/d), and reduced milk fat content (3.41 vs. 3.55%). However, PF cows had reduced pregnancy losses per service compared with CON (12.6 vs. 18.3%). Serum progesterone was greater and serum insulin tended to be greater in primiparous cows receiving PF compared with CON cohorts (4.50 vs. 3.67 ng of progesterone/mL, and 10.4 vs. 7.5 mu UI of insulin/mL). During experiment 2, no treatment effects were detected for feed intake, milk yield, or milk fat, whereas PF1X cows tended to have reduced pregnancy losses per service compared with PF6X (14.4 vs. 18.4%). In summary, feeding Ca salts of PUFA to dairy cows increased milk production, did not alter feed intake, and reduced pregnancy losses per service. Further, the total daily amount of Ca salts of RITA should be fed during the first feeding of the day to optimize its benefits on pregnancy maintenance of dairy cows.
Resumo:
Three semen samples were collected at 48 It intervals from 20 mature research dogs previously conditioned to manual semen collection. Vasectomy was performed in all dogs, and 15 days after surgery, another three ejaculates were similarly collected. The semen was evaluated, and centrifuged to obtain seminal plasma for measurement of pH, and concentrations of total proteins (TP), total chlorides (Cl), calcium (Ca), potassium (K), and sodium (Na). The seminal plasma protein profile was evaluated by SDS-PAGE; molecular weights and the integrated optical density (IOD) of each band were estimated. There was a negative correlation between K concentration and progressive motility (r = -0.49, P = 0.027), sperm vigor (r = -0.60, P = 0.0053), and plasma integrity, evaluated by both the hypo-osmotic swelling test (r = -0.50, P = 0.026) and a fluorescent stain (r = -0.45, P = 0.046). Positive correlations between Na and K pre- and post-vasectomy (r = 0.88, P < 0.001; r = 0.56, P < 0.01, respectively) were verified. There were a total of 37 bands pre-vasectomy and 35 post-vasectomy (range, 100.6-3.6 kDa). Bands B9 and B13 (42.6 and 29.2 kDa) were not present post-vasectomy. The IOD of band B3 (73.5 kDa) was higher (P 0.03) pre-vasectomy, compared to post-vasectomy; conversely, the IODs of bands B29 and B37 (7.8 and 3.6 kDa) increased (P 0.026 and 0.047). Pre-vasectomy, there was a positive correlation (r = 0.49, P = 0.029) between band B37 band (3.6 kDa) and the Na:K ratio. In conclusion, K appeared to be involved in sperm motility in dogs and could be a tool to evaluate sperm function. The prostate contributed several elements to canine seminal plasma. Vasectomy changed Ca concentrations and the protein profile of the seminal plasma. Further studies must be performed to clarify the function of these elements on the in vivo fertility of dogs. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Combining the data from conventional semen analysis with oocyte penetration assays should improve the assessment of the fertilizing ability of a semen sample. Thus, the objective of the present study was to evaluate the prognostic value of various semen parameters on the in vitro interactions between frozen-thawed canine sperm and homologous oocytes. Ten ejaculates from five stud dogs (two ejaculates/dog) were collected by digital manipulation. Semen samples were evaluated, extended in Tris-egg yolk-glycerol, frozen and stored in liquid nitrogen, and thawed several weeks later. Samples were evaluated for motility and sperm populations by computer-aided semen analysis (CASA), plasma membrane integrity (carboxy-fluorescein diacetate and propidium iodide), and sperm morphology (Bengal Rose). Thawed spermatozoa were also incubated with homologous oocytes for 18 h in an atmosphere of 5% CO2 and 95% air at 38 degrees C and sperm-oocyte interactions were evaluated. Simple linear regression models were calculated, with sperm parameters as independent variables and sperm-oocyte interactions as the dependent variable. There were significant associations between: percentage of oocytes bound to spermatozoa and beat cross frequency (BCF; R-2 = 63%); percentage of oocytes that interacted with spermatozoa and BCF (R-2 = 73%); and number of penetrated spermatozoa and velocity average pathway (VAP; R-2 = 64%) and velocity straight line (VSL; R-2 = 64%). Although plasma membrane integrity and sperm morphology had little prognostic value for in vitro interactions between canine frozen-thawed sperm and homologous oocytes, some motility patterns (evaluated by CASA) were predictive of in vitro sperm-oocyte interactions. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: The purpose of this study was to evaluate the effect of low-level laser therapy (LLLT) on wound healing process and pain levels after premolar extraction in adolescents. Background data: The advantage of using LLLT in oral surgeries is the reduction of inflammation and postoperative discomfort; however, the optimal dosing parameters and treatment effects in surgical procedures are inconclusive. Methods: A double-blind, randomized, controlled clinical trial was conducted with 14 patients who were to undergo surgical removal of premolars. Patients were randomly allocated to the LLLT (test) group and placebo (control) group. Patients in the test group received 5.1 J (60 J/cm(2)) of energy density of a gallium-aluminum-arsenide (GaAlAs) diode laser (wavelength, 830 nm; output power, 0.1 W) at three different points intraorally, 1 cm from the target tissue immediately and at 48 and 72 h after the surgical procedure. For patients in the placebo group, the laser device was applied to the same points without activating the hand piece. The wound healing process was evaluated by an independent examiner by visual inspection with the support of digital photographs at baseline and 2, 7, and 15 days postoperatively. Patients recorded the degree of pain using the visual analogue scale (VAS). Results: Compared with the placebo group, the test group showed a lower intensity of pain, but this difference was not statistically significant at any time point. The wound healing process was similar in both groups. Conclusions: Within the limitations of this study, the LLLT parameters used neither increased the wound healing process nor significantly decreased pain intensity after premolar extraction in adolescents.
Resumo:
Objectives: the aim of this study was to evaluate in vitro, by scanning electron microscopy (SEM), the adhesion of blood components on root surfaces irradiated with Er:YAG (2.94 mu m) and GaAlAs Diode (808 nm) lasers and the effects on the morphology of irradiated root surfaces.Methods: One hundred samples of human teeth were obtained. They were previously planed and scaled with manual instruments and divided into five groups of 20 samples each: G1 (control group) - absence of treatment; G2 - Er:YAG laser (7.6 J/cm(2)); G3 - Er:YAG laser (12.9 J/cm(2)); G4 - Diode laser (90 J/cm(2)) and G5 - Diode laser (108 J/cm(2)). After these treatments, 10 samples of each group received a blood tissue but the remaining 10 did not. After laboratory treatments, the samples were obtained by SEM, the photomicrographs were analysed by the score of adhesion of blood components and the results were statistically analysed (Kruskall-Wallis and Mann-Whitney test).Results: In relation to the adhesion of blood components, the study showed no significant differences between the control group and the groups treated with Er:YAG laser (p = 0.9633 and 0.6229). Diode laser radiation was less effective than control group and Er:YAG laser radiation (p < 0.01).Conclusion: None of the proposed treatments increased the adhesion of blood components in a significant way when compared to the control group. Although the Er:YAG laser did not interfere in the adhesion of blood components, it caused more changes on the root surface, whereas the Diode laser inhibited the adhesion.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Dentin hipersensitivity (DH) is a relatively common clinical condition, especially in periodontal patients after treatment. In this study it was evaluated 28 teeth who presented dentin hypersensitivity. The teeth were subjected to clinical and radiographic exams and were divided into groups following the treatment and the time of examination after application proposed: GI: PO 3% (Potassium Oxalate-group control)/Baseline; GII: PO 3%/3 days after first session; GIII: PO 3%/6 days; GIV: PO 3%/30 days; GV: PO 3%/60 days; GVI: PO 3%/90 days; GVII: Laser (Low-level diode laser with 110 mW/cm(2))/Baseline; GVIII: Laser/7 days after first session; GIX: Laser/14 days; GX: Laser/30 days; GXI: Laser/60 days; and GXII: Laser/90 days. The groups I-VI, the teeth were subjected to 3 applications (GI-GIII) of desensitizing agent at regular intervals of seven days. The Groups VII-XI, each tooth was subjected to three applications (GVII GIX) in three different points (mesial, meddle and distal surfaces) with an interval of 72 h. The time of application in each point was of 33 s and the patients from both groups were followed up to 90 days. The nonparametric test Friedman (alpha = 0.05) was applied and the test of Mann Whitney (alpha = 0.05) was used to compare the time of examination between groups. The application of Laser was effective 6 days after first session and to PO was 30 days. It was observed that both treatments were effective for the reduction of dentin hypersensitivity, however the laser presented better effectiveness.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)