997 resultados para Delayed diagnosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acquired hemophilia A (AHA) is a rare bleeding disorder characterized by autoantibodies directed against circulating coagulation factor (F) VIII. Typically, patients with no prior history of a bleeding disorder present with spontaneous bleeding and an isolated prolonged aPTT. AHA may, however, present without any bleeding symptoms, therefore an isolated prolonged aPTT should always be investigated further irrespective of the clinical findings. Control of acute bleeding is the first priority, and we recommend first-line therapy with bypassing agents such as recombinant activated FVII or activated prothrombin complex concentrate. Once the diagnosis has been achieved, immediate autoantibody eradication to reduce subsequent bleeding risk should be performed. We recommend initial treatment with corticosteroids or combination therapy with corticosteroids and cyclophosphamide and suggest second-line therapy with rituximab if first-line therapy fails or is contraindicated. In contrast to congenital hemophilia, no comparative studies exist to support treatment recommendations for patients with AHA, therefore treatment guidance must rely on the expertise and clinical experience of specialists in the field. The aim of this document is to provide a set of international practice guidelines based on our collective clinical experience in treating patients with AHA and contribute to improved care for this patient group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laboratory diagnosis of intestinal schistosomiasis mansoni can be accomplished through various methods of stool examination to detect parasites, ranging from the most classic tests (Kato-Katz) to several methods that are still undergoing validation. This study was conducted to assess two new parasite identification methods for diagnosing schistosomiasis mansoni in residents of a low endemic area in the municipality of Maranguape, in the state of Ceará, Brazil using the Kato-Katz method as a reference and serology (enzyme-linked immunosorbent assay) for the screening of patients. The Kato-Katz, the saline gradient method and the Helmintex® method parasite identification methods were employed only in subjects who exhibited positive serologic tests. The test results were then analysed and treatment of positive individuals was subsequently performed. After comparing the test results, we observed that the saline gradient method and the Helmintex® method were more effective in diagnosing schistosomiasis mansoni in the study area compared with the Kato-Katz method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Niterói, state of Rio de Janeiro, dengue virus type 4 (DENV-4) was isolated for the first time in March 2011. We analysed the laboratory findings of the first cases and evaluated the use of molecular techniques for the detection of DENV-4 in Aedes aegypti that were field-caught. Conventional reverse transcriptase-polymerase chain reaction (RT-PCR) and SimplexaTM Dengue real-time RT-PCR confirmed DENV-4 infection in all cases. Additionally, DENV-4 was confirmed in a female Ae. aegypti with 1.08 x 10³ copies/mL of virus, as determined by quantitative real-time RT-PCR. This is the first time the SimplexaTM Dengue real-time assay has been used for the classification of cases of infection and for entomological investigations. The use of these molecular techniques was shown to be important for the surveillance of dengue in humans and vectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performances of two rapid tests and a standard serological test for the diagnosis of visceral leishmaniasis (VL) were compared using sera from 193 patients with VL and 85 controls. The Kala-Azar Detect®, IT-LEISH® and IFI-LH® assays showed sensitivities of 88.1%, 93.3% and 88.6%, respectively, and specificities of 90.6%, 96.5% and 80%, respectively. The sensitivity values were similar for both rapid tests, but the specificity and positive predictive values of IT-LEISH® were higher than the corresponding values for IFI-LH®. Both rapid tests showed satisfactory performances and can be used in primary health care settings; however, IT-LEISH® permits the use of whole blood, making this assay more suitable for bedside diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The detection of anti-hepatitis A virus (HAV) antibody levels by diagnostic kits in the convalescent period of disease generally use immunoglobulin G (IgG), which is expensive. An alternative to IgG is immunoglobulin Y (IgY), an immunoglobulin antibody encountered in birds and reptiles. The aim of this study was to develop a competitive immunoenzymatic assay to measure total anti-HAV antibody levels using anti-HAV IgY as the capture and conjugated immunoglobulins. For this purpose, anti-HAV IgY was conjugated to horseradish peroxidase (HRP) and the optimal dilution of HRP-conjugated antibodies was evaluated to establish the competitive immuneenzymatic assay. The results obtained from our "in-house" assay were plotted on a receiver operator curve, which showed a sensitivity of 95% and a specificity of 98.8%, demonstrating that a competitive anti-HAV IgY immunoenzymatic assay developed "in house" could be used as an alternative to commercial assays that utilise IgG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cerebrospinal fluid (CSF) samples from clinically diagnosed patients with detectable Angiostrongylus canto-nensis-specific antibodies (n = 10), patients with clinically suspected cases that tested negative for A. cantonensis-an-tibodies (n = 5) and patients with cerebral gnathostomiasis (n = 2) and neurocysticercosis (n = 2) were examined by a single-step polymerase chain reaction (PCR) method using the AC primers for the 66-kDa native protein gene. The PCR method detected A. cantonensis DNA in CSF samples from four of 10 serologically confirmed angiostrongyliasis cases. The PCR results were negative for the remaining CSF samples. The nucleotide sequences of three positive CSF-PCR samples shared 98.8-99.2% similarity with the reference sequence of A. cantonensis. These results indicate the potential application of this PCR assay with clinical CSF samples for additional support in the confirmation of eosinophilic meningitis due to A. cantonensis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this study was to demonstrate the usefulness of an enzyme-linked immunosorbent assay (ELISA) for the serodiagnosis of pulmonary tuberculosis (PTB) and extrapulmonary TB (EPTB). This assay used 20 amino acid-long, non-overlapped synthetic peptides that spanned the complete Mycobacterium tuberculosis ESAT-6 and Ag85A sequences. The validation cohort consisted of 1,102 individuals who were grouped into the following five diagnostic groups: 455 patients with PTB, 60 patients with EPTB, 40 individuals with non-EPTB, 33 individuals with leprosy and 514 healthy controls. For the PTB group, two ESAT-6 peptides (12033 and 12034) had the highest sensitivity levels of 96.9% and 96.2%, respectively, and an Ag85A-peptide (29878) was the most specific (97.4%) in the PTB groups. For the EPTB group, two Ag85A peptides (11005 and 11006) were observed to have a sensitivity of 98.3% and an Ag85A-peptide (29878) was also the most specific (96.4%). When combinations of peptides were used, such as 12033 and 12034 or 11005 and 11006, 99.5% and 100% sensitivities in the PTB and EPTB groups were observed, respectively. In conclusion, for a cohort that consists entirely of individuals from Venezuela, a multi-antigen immunoassay using highly sensitive ESAT-6 and Ag85A peptides alone and in combination could be used to more rapidly diagnose PTB and EPTB infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate ultrasonographic (US) cross-sectional areas (CSAs) of peripheral nerves, indexes of the differences between CSAs at the same point (∆CSAs) and between tunnel (T) and pre-tunnel (PT) ulnar CSAs (∆TPTs) in leprosy patients (LPs) and healthy volunteers (HVs). Seventy-seven LPs and 49 HVs underwent bilateral US at PT and T ulnar points, as well as along the median (M) and common fibular (CF) nerves, to calculate the CSAs, ∆CSAs and ∆TPTs. The CSA values in HVs were lower than those in LPs (p < 0.0001) at the PT (5.67/9.78 mm2) and T (6.50/10.94 mm2) points, as well as at the M (5.85/8.48 mm2) and CF (8.17/14.14 mm2) nerves. The optimum CSA- receiver operating characteristic (ROC) points and sensitivities/specificities were, respectively, 6.85 mm2 and 68-85% for the PT point, 7.35 mm2 and 71-78% for the T point, 6.75 mm2 and 62-75% for the M nerve and 9.55 mm2 and 81-72% for the CF nerve. The ∆CSAs of the LPs were greater than those of the HVs at the PT point (4.02/0.85; p = 0.007), T point (3.71/0.98; p = 0.0005) and CF nerve (2.93/1.14; p = 0.015), with no difference found for the M nerve (1.41/0.95; p = 0.17). The optimum ∆CSA-ROC points, sensitivities, specificities and p-values were, respectively, 1.35, 49%, 80% and 0.003 at the PT point, 1.55, 55-85% and 0.0006 at the T point, 0.70, 58-50% and 0.73 for the M nerve and 1.25, 54-67% and 0.022 for the CF nerve. The ∆TPT in the LPs was greater than that in the HVs (4.43/1.44; p <0.0001). The optimum ∆TPT-ROC point was 2.65 (90% sensitivity/41% specificity, p < 0.0001). The ROC analysis of CSAs showed the highest specificity and sensitivity at the PT point and CF nerve, respectively. The PT and T ∆CSAs had high specificities (> 80%) and ∆TPT had the highest specificity (> 90%). New sonographic peripheral nerve measurements (∆CSAs and ∆TPT) provide an important methodological improvement in the detection of leprosy neuropathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Schistosomiasis diagnosis is based on the detection of eggs in the faeces, which is laborious and lacks sensitivity, especially for patients with a low parasite burden. Immunological assays for specific antibody detection are available, but they usually demonstrate low sensitivity and/or specificity. In this study, two simple immunological assays were evaluated for the detection of soluble Schistosoma mansoni adult worm preparation (SWAP) and egg-specific IgGs. These studies have not yet been evaluated for patients with low parasite burdens. Residents of an endemic area in Brazil donated sera and faecal samples for our study. The patients were initially diagnosed by a rigorous Kato-Katz analysis of 18 thick smears from four different stool samples. The ELISA-SWAP was successful for human diagnosis with 90% sensitivity and specificity, confirming the Kato-Katz diagnosis with nearly perfect agreement, as seen by the Kappa index (0.85). Although the ELISA-soluble S. mansoni egg antigen was 85% sensitive, it exhibited low specificity (80%; Kappa index: 0.75) and was more susceptible to cross-reactivity. We believe that immunological assays should be used in conjunction with Kato-Katz analysis as a supplementary tool for the diagnosis of schistosomiasis for patients with low infection burdens, which are usually hard to detect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amoxicillin, a low-molecular-weight compound, is able to interact with dendritic cells inducing semi-maturation in vitro. Specific antigens and TLR ligands can synergistically interact with dendritic cells (DC), leading to complete maturation and more efficient T-cell stimulation. The aim of the study was to evaluate the synergistic effect of amoxicillin and the TLR2, 4 and 7/8 agonists (PAM, LPS and R848, respectively) in TLR expression, DC maturation and specific T-cell response in patients with delayed-type hypersensitivity (DTH) reactions to amoxicillin. Monocyte-derived DC from 15 patients with DTH to amoxicillin and 15 controls were cultured with amoxicillin in the presence or absence of TLR2, 4 and 7/8 agonists (PAM, LPS and R848, respectively). We studied TLR1-9 gene expression by RT-qPCR, and DC maturation, lymphocyte proliferation and cytokine production by flow cytometry. DC from both patients and controls expressed all TLRs except TLR9. The amoxicillin plus TLR2/4 or TLR7/8 ligands showed significant differences, mainly in patients: AX+PAM+LPS induced a decrease in TLR2 and AX+R848 in TLR2, 4, 7 and 8 mRNA levels. AX+PAM+LPS significantly increased the percentage of maturation in patients (75%) vs. controls (40%) (p=0.036) and T-cell proliferation (80.7% vs. 27.3% of cases; p=0.001). Moreover, the combinations AX+PAM+LPS and AX+R848 produced a significant increase in IL-12p70 during both DC maturation and T-cell proliferation. These results indicate that in amoxicillin-induced maculopapular exanthema, the presence of different TLR agonists could be critical for the induction of the innate and adaptive immune responses and this should be taken into account when evaluating allergic reactions to these drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Pollen is one of the main causes of allergic sensitization. It is not easy to make an etiological diagnosis of pollen-allergic patients because of the wide variety of sensitizing pollens, association with food allergy, and increasing incidence of polysensitization, which may result from the presence of allergens that are common to different species, as is the case of panallergens. OBJECTIVE To compare the results of skin prick tests (SPT) using whole pollen extract with specific immunoglobulin (Ig) E determination for several allergens (purified panallergens included) in the diagnosis of polysensitized pollen-allergic patients. METHODS The study sample comprised 179 pollen-sensitized patients who underwent SPT with pollen extract and allergen-specific IgE determination against different allergens. RESULTS The level of concordance between the traditional diagnostic test (SPT) and IgE determination was low, especially in patients sensitized to the panallergens profilin and polcalcin. In the case of SPT, the results demonstrated that patients who are sensitized to either of these panallergens present a significantly higher number of positive results than patients who are not. However, IgE determination revealed that while patients sensitized to polcalcins are sensitized to allergens from a higher number of pollens than the rest of the sample, this is not the case in patients sensitized to profilins. On the other hand, sensitization to profilin or lipid transfer proteins was clearly associated with food allergy. CONCLUSIONS Sensitization to panallergens could be a confounding factor in the diagnosis of polysensitized pollen-allergic patients as well as a marker for food allergy. However, more studies are required to further investigate the role of these molecules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Functional brain images such as Single-Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) have been widely used to guide the clinicians in the Alzheimer's Disease (AD) diagnosis. However, the subjectivity involved in their evaluation has favoured the development of Computer Aided Diagnosis (CAD) Systems. METHODS It is proposed a novel combination of feature extraction techniques to improve the diagnosis of AD. Firstly, Regions of Interest (ROIs) are selected by means of a t-test carried out on 3D Normalised Mean Square Error (NMSE) features restricted to be located within a predefined brain activation mask. In order to address the small sample-size problem, the dimension of the feature space was further reduced by: Large Margin Nearest Neighbours using a rectangular matrix (LMNN-RECT), Principal Component Analysis (PCA) or Partial Least Squares (PLS) (the two latter also analysed with a LMNN transformation). Regarding the classifiers, kernel Support Vector Machines (SVMs) and LMNN using Euclidean, Mahalanobis and Energy-based metrics were compared. RESULTS Several experiments were conducted in order to evaluate the proposed LMNN-based feature extraction algorithms and its benefits as: i) linear transformation of the PLS or PCA reduced data, ii) feature reduction technique, and iii) classifier (with Euclidean, Mahalanobis or Energy-based methodology). The system was evaluated by means of k-fold cross-validation yielding accuracy, sensitivity and specificity values of 92.78%, 91.07% and 95.12% (for SPECT) and 90.67%, 88% and 93.33% (for PET), respectively, when a NMSE-PLS-LMNN feature extraction method was used in combination with a SVM classifier, thus outperforming recently reported baseline methods. CONCLUSIONS All the proposed methods turned out to be a valid solution for the presented problem. One of the advances is the robustness of the LMNN algorithm that not only provides higher separation rate between the classes but it also makes (in combination with NMSE and PLS) this rate variation more stable. In addition, their generalization ability is another advance since several experiments were performed on two image modalities (SPECT and PET).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some sites of extrapulmonary tuberculosis and focal complications of brucellosis are very difficult to differentiate clinically, radiologically, and even histopathologically. Conventional microbiological methods for the diagnosis of extrapulmonary tuberculosis and complicated brucellosis not only lack adequate sensitivity, they are also time consuming, which could lead to an unfavourable prognosis. The aim of this work was to develop a multiplex real-time PCR assay based on SYBR Green I to simultaneously detect Brucella spp and Mycobacterium tuberculosis complex and evaluate the efficacy of the technique with different candidate genes. The IS711, bcsp31 and omp2a genes were used for the identification of Brucella spp and the IS6110, senX3-regX3 and cfp31 genes were targeted for the detection of the M. tuberculosis complex. As a result of the different combinations of primers, nine different reactions were evaluated. A test was defined as positive only when the gene combinations were capable of co-amplifying both pathogens in a single reaction tube and showed distinguishable melting temperatures for each microorganism. According to the melting analysis, only three combinations of amplicons (senX3-regX3+bcsp31, senX3-regX3+IS711 and IS6110+IS711) were visible. Detection limits of senX3-regX3+bcsp31 and senX3-regX3+IS711 were of 2 and 3 genome equivalents for M. tuberculosis complex and Brucella while for IS6110+IS711 they were of 200 and 300 genome equivalents, respectively. The three assays correctly identified all the samples, showing negative results for the control patients. The presence of multicopy elements and GC content were the components most influencing the efficiency of the test; this should be taken into account when designing a multiplex-based SYBR Green I assay. In conclusion, multiplex real time PCR assays based on the targets senX3-regX3+bcsp31 and senX3-regX3+IS711 using SYBR Green I are highly sensitive and reproducible. This may therefore be a practical approach for the rapid differential diagnosis between extrapulmonary tuberculosis and complicated brucellosis.