920 resultados para Cost control


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We introduce multiple-control fuzzy vaults allowing generalised threshold, compartmented and multilevel access structure. The presented schemes enable many useful applications employing multiple users and/or multiple locking sets. Introducing the original single control fuzzy vault of Juels and Sudan we identify several similarities and differences between their vault and secret sharing schemes which influence how best to obtain working generalisations. We design multiple-control fuzzy vaults suggesting applications using biometric credentials as locking and unlocking values. Furthermore we assess the security of our obtained generalisations for insider/ outsider attacks and examine the access-complexity for legitimate vault owners.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presentation provided to a PhD Colloquium between two Australian and one Malaysian University providing the opportunity to inform and critique progress of students concerning their selected topic. This presentation essentially involves "The conceptualisation, sensitivity and measurement of holding costs and other selected elements impacting housing affordability" as provided by Gary Owen Garner of QUT, with research objectives thus: 1. To establish the nature and composition of holding costs over time, as related to residential property in Australia, and internationally. 2. To examine the linkages that may exist between various planning instruments, the length of regulatory assessment periods, and housing affordability. 3. To develop a model that quantifies the impact of holding costs on housing affordability in Australia, with a particular focus on the consequences of extended assessment periods as a component of holding costs. Thus, provide clarification as to the impact of holding costs on overall housing affordability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-output boost (MOB) converter is a novel DC-DC converter unlike the regular boost converter, has the ability to share its total output voltage and to have different series output voltage from a given duty cycle for low and high power applications. In this paper, discrete voltage control with inner hysteresis current control loop has been proposed to keep the simplicity of the control law for the double-output MOB converter, which can be implemented by a combination of analogue and logical ICs or simple microcontroller to constrain the output voltages of MOB converter at their reference voltages against variation in load or input voltage. The salient features of the proposed control strategy are simplicity of implementation and ease to extend to multiple outputs in the MOB converter. Simulation and experimental results are presented to show the validity of control strategy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims & Rationale/Objectives: With the knowledge that overweight is a major public health concern in Australia, that a multidisciplinary team approach to the management of lifestyle-related conditions is supported, and that the Australian Government recently recognised the role of the exercise physiologist (EP) in reducing the health burden of disease by their inclusion for reimbursement under the Medicare Plus scheme, this study sought to undertake a pilot RCT to compare GP and EP interventions to reduce primary cardiovascular risk in the overweight general practice population. Methods and Measures: Overweight patients recruited by a convenience sample of GPs were randomised into one of three arms: the control group, or the GP or EP intervention group (in which patients received either five GP or five EP consultations over 24 weeks). Patients had baseline, 12- and 24-week measures of body composition and cardio-respiratory fitness, and completed baseline and end-of-study surveys, fasting lipids and glucose. GPs and EPs completed an end-of-study survey. Results:Sixty-seven patients attended the baseline assessment. Overall retention rate was 67%. Patients were generally satisfied with the effectiveness of the interventions and their weight reduction. Favourable trends in BMI, weight, glucose and exercise levels for GP and EP intervention groups and in physical activity levels for all groups Conclusions: This study supports the feasibility of a RCT of GP and EP interventions for decreasing primary cardiovascular risk in the overweight general practice population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper shows how the power quality can be improved in a microgrid that is supplying a nonlinear and unbalanced load. The microgrid contains a hybrid combination of inertial and converter interfaced distributed generation units where a decentralized power sharing algorithm is used to control its power management. One of the distributed generators in the microgrid is used as a power quality compensator for the unbalanced and harmonic load. The current reference generation for power quality improvement takes into account the active and reactive power to be supplied by the micro source which is connected to the compensator. Depending on the power requirement of the nonlinear load, the proposed control scheme can change modes of operation without any external communication interfaces. The compensator can operate in two modes depending on the entire power demand of the unbalanced nonlinear load. The proposed control scheme can even compensate system unbalance caused by the single-phase micro sources and load changes. The efficacy of the proposed power quality improvement control and method in such a microgrid is validated through extensive simulation studies using PSCAD/EMTDC software with detailed dynamic models of the micro sources and power electronic converters

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multilevel inverters provide an attractive solution for power electronics when both reduced harmonic contents and high voltages are required. In this paper, a novel predictive current control technique is proposed for a three-phase multilevel inverter, which controls the capacitors voltages and load currents with low switching losses. The advantage of this contribution is that the technique can be applied to more voltage levels without significantly changing the control circuit. The three-phase three-level inverter with a pure inductive load has been implemented to track reference currents using analogue circuits and programmable logic device.