915 resultados para Contamination by Pb
Resumo:
Endocrine disruptors and pharmaceuticals are considered to be concerning environmental contaminants. During the last two decades, studies dealing with the occurrence and fate of these emerging contaminants in the aquatic environment have raised attention and its number is constantly increasing. The presence of these contaminants in the environment is particularly important since they are known to induce adverse effects in the ecosystems even at extremely low concentrations. Estrogens and antibiotics, in particular, are identified as capable of induce endocrine disruption and contribute for the appearance of multi-resistant bacteria, respectively. A better assessment and understanding of the real impact of these contaminants in the aquatic environment implies the evaluation of their occurrence and fate, which is the main aim of this Thesis. Two estrogens (17-estradiol and 17-ethinylestradiol) and an antibiotic (sulfamethoxazole) were the contaminants under study and their occurrence in surface and waste waters was assessed by the implementation of enzyme linked immunosorbent assays (ELISAs). The assays were optimized in order to accomplish two important aspects: to analyze complex water samples, giving special attention to matrix effects, and to increase the sensitivity. Since the levels of these contaminants in the environment are extremely low, a pre-concentration methodology was also object of study in this Thesis. Dispersive liquid-liquid microextraction (DLLME) was developed for the preconcentration of E2 and EE2, subsequently quantified by either highperformance liquid chromatography (HPLC) and the previously optimized ELISAs. Moreover, the use of anthropogenic markers, i.e. indicators of human presence or activity, has been discussed as a tool to track the origin and type of contamination. An ELISA for the quantification of caffeine, as an anthropogenic marker, was also developed in order to assess the occurrence of human domestic pollution in Portuguese surface waters. Finally, photodegradation is considered to be one of the most important pathways contributing for the mitigation of pollutants’ presence in the aquatic environment. Both direct and indirect photodegradation of E2 and EE2 were evaluated. Since the presence of humic substances (HS) is known to have a noticeable influence on the photodegradation of pollutants and in order to mimic the real aquatic environment, special attention was given to the influence of the presence and concentration of different fractions of HS on the photodegradation of both hormones.
Resumo:
Dissertação de mest., Gestão da Água e da Costa, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2009
Resumo:
Tese de doutoramento, Geologia (Geoquímica), Universidade de Lisboa, Faculdade de Ciências, 2016
Resumo:
Background World Health Organization hand hygiene guidelines state that if electric hand dryers are used, they should not aerosolize pathogens. Previous studies have investigated the dispersal by different hand-drying devices of chemical indicators, fungi and bacteria on the hands. This study assessed the aerosolization and dispersal of virus on the hands to determine any differences between hand-drying devices in their potential to contaminate other occupants of public washrooms and the washroom environment. Methods A suspension of MS2, an Escherichia coli bacteriophage virus, was used to artificially contaminate the hands of participants prior to using three different handdrying devices: jet air dryer, warm air dryer, paper towel dispenser. Virus was detected by plaque formation on agar plates layered with the host bacterium. Vertical dispersal of virus was assessed at a fixed distance (0.4 m) and over a range of different heights (0.0 – 1.8 m) from the floor. Horizontal dispersal was assessed at different distances of up to three metres from the hand-drying devices. Virus aerosolization and dispersal was also assessed at different times up to 15 minutes after use by means of air sampling at two distances (0.1 and 1.0 m) and at a distance behind and offset from each of the hand-drying devices. Results Over a range of heights, the jet air dryer was shown to produce over 60 times greater vertical dispersal of virus from the hands than a warm air dryer and over 1300 times greater than paper towels; the maximum being detected between 0.6 and 1.2 metres from the floor. Horizontal dispersal of virus by the jet air dryer was over 20 times greater than a warm air dryer and over 190 times greater than paper towels; virus being detected at distances of up to three metres. Air sampling at three different positions from the hand-drying devices 15 minutes after use showed that the jet air dryer produced over 50-times greater viral contamination of the air than a warm air dryer and over 110-times greater than paper towels. Conclusions Due to their high air speed, jet air dryers aerosolize and disperse more virus over a range of heights, greater distances, and for longer times than other hand drying devices. If hands are inadequately washed, they have a greater potential to contaminate other occupants of a public washroom and the washroom environment. Main messages: Jet air dryers with claimed air speeds of over 600 kph have a greater potential than warm air dryers or paper towels to aerosolize and disperse viruses on the hands of users. The choice of hand-drying device should be carefully considered. Jet air dryers may increase the risk of transmission of human viruses, such as norovirus, particularly if hand washing is inadequate.
Resumo:
Background World Health Organization and EU hand hygiene guidelines state that if electric hand dryers are used, they should not aerosolize pathogens. Previous studies have investigated the dispersal by different hand-drying devices of chemical indicators, fungi and bacteria on the hands. This study assessed the aerosolization and dispersal of virus on the hands to determine any differences between hand-drying devices in their potential to contaminate other occupants of public washrooms and the washroom environment. Methods A suspension of MS2, an Escherichia coli bacteriophage virus, was used to artificially contaminate the hands of participants prior to using three different hand-drying devices: jet air dryer, warm air dryer, paper towel dispenser. Virus was detected by plaque formation on agar plates layered with the host bacterium. Vertical dispersal of virus was assessed at a fixed distance (0.4 m) and over a range of different heights (0.0 – 1.8 m) from the floor. Horizontal dispersal was assessed at different distances of up to three metres from the hand-drying devices. Virus aerosolization and dispersal was also assessed at different times up to 15 minutes after use by means of air sampling at two distances (0.1 and 1.0 m) and at a distance behind and offset from each of the hand-drying devices. Results Over a range of heights, the jet air dryer was shown to produce over 60 times greater vertical dispersal of virus from the hands than a warm air dryer and over 1300 times greater than paper towels; the maximum being detected between 0.6 and 1.2 metres from the floor. Horizontal dispersal of virus by the jet air dryer was over 20 times greater than a warm air dryer and over 190 times greater than paper towels; virus being detected at distances of up to three metres. Air sampling at three different positions from the hand-drying devices 15 minutes after use showed that the jet air dryer produced over 50-times greater viral contamination of the air than a warm air dryer and over 110-times greater than paper towels. Conclusions Due to their high air speed, jet air dryers aerosolize and disperse more virus over a range of heights, greater distances, and for longer times than other hand drying devices. If hands are inadequately washed, they have a greater potential to contaminate other occupants of a public washroom and the washroom environment. Main messages: Jet air dryers with claimed air speeds of over 600 kph have a greater potential than warm air dryers or paper towels to aerosolize and disperse viruses on the hands of users. The choice of hand-drying device should be carefully considered. Jet air dryers may increase the risk of transmission of human viruses, such as norovirus, particularly if hand washing is inadequate.
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.
Resumo:
This paper aims to survey metal concentrations in soils in the vicinity of a coal-firedpower plant located in southwest of Portugal. Two annual sampling campaigns were carried out to measure a hypothetical soil contamination around the coal plant. The sampling area was divided into two subareas, both centered in the emission source, delimited by two concentric circles with radius of 6 km and 20 km. About 40 samplings points were defined in the influence area. Metals measurements were performed with a portable analytical X-ray dispersive energy fluorescence spectrometer identifying about 20 different elements in each sampling point. The most relevant elements measured included As, Cu, Fe, Hg, Pb, Ti and Zn in both sampling areas. Considering the results obtained in the first sampling campaign, arsenic is predominantly higher within the 6-20 km sampling area. The second sampling campaign showed that both sampling areas presented relatively similar metal concentrations except for Fe, Mn, Sr and Zn which concentration is higher within the 6-20 km sampling area. Also, As, Fe, Mn and Ti concentrations decreased significantly from the first to the second sampling campaign and their concentration were predominately higher in the NE-E and E-SE directions.
Resumo:
The excessive use of pesticides and fertilisers in agriculture has generated a decrease in groundwater and surface water quality in many regions of the EU, constituting a hazard for human health and the environment. Besides, on-site sewage disposal is an important source of groundwater contamination in urban and peri-urban areas. The assessment of groundwater vulnerability to contamination is an important tool to fulfil the demands of EU Directives. The purpose of this study is to assess the groundwater vulnerability to contamination related mainly to agricultural activities in a peri-urban area (Vila do Conde, NW Portugal). The hydrogeological framework is characterised mainly by fissured granitic basement and sedimentary cover. Water samples were collected and analysed for temperature, pH, electrical conductivity, chloride, phosphate, nitrate and nitrite. An evaluation of groundwater vulnerability to contamination was applied (GOD-S, Pesticide DRASTIC-Fm, SINTACS and SI) and the potential nitrate contamination risk was assessed, both on a hydrogeological GIS-based mapping. A principal component analysis was performed to characterised patterns of relationship among groundwater contamination, vulnerability, and the hydrogeological setting assessed. Levels of nitrate above legislation limits were detected in 75 % of the samples analysed. Alluvia units showed the highest nitrate concentrations and also the highest vulnerability and risk. Nitrate contamination is a serious problem affecting groundwater, particularly shallow aquifers, especially due to agriculture activities, livestock and cesspools. GIS-based cartography provided an accurate way to improve knowledge on water circulation models and global functioning of local aquifer systems. Finally, this study highlights the adequacy of an integrated approach, combining hydrogeochemical data, vulnerability assessments and multivariate analysis, to understand groundwater processes in peri-urban areas.
Resumo:
Proceedings of the 13th International UFZ-Deltares Conference on Sustainable Use and Management of Soil, Sediment and Water Resources - 9–12 June 2015 • Copenhagen, Denmark
Resumo:
The present work has as objective to contribute for the elucidation of the mechanism associated with Pb detoxification, using the yeast Saccharomyces cerevisiae as a model organism. The deletion of GTT1 or GTT2 genes, coding for functional glutathione transferases (GST) enzymes in S. cerevisiae, caused an increased susceptibility to high Pb concentrations (500-1000 μmol L(-1)). These results suggest that the formation of glutathione-Pb conjugate (GS-Pb), dependent of GSTs, is important in Pb detoxification. The involvement of ATP-binding cassette (ABC) vacuolar transporters, belonging to class C subfamily (ABCC) in vacuolar compartmentalization of Pb, was evaluated. For this purpose, mutant strains disrupted in YCF1, VMR1, YBT1 or BPT 1 genes were used. All mutants tested, without vacuolar ABCC transporters, presented an increased sensitivity to 500-1000 μmol L(-1) Pb comparative to wild-type strain. Taken together, the obtained results suggest that Pb detoxification, by vacuolar compartmentalization, can occur as a result of the concerted action of GSTs and vacuolar ABCC transporters. Pb is conjugated with glutathione, catalysed by glutathione transferases and followed to the transport of GS-Pb conjugate to the vacuole by ABCC transporters.
Resumo:
Clenbuterol is a β2 agonist agent with anabolic properties given by the increase in the muscular mass in parallel to the decrease of the body fat. For this reason, the use of clenbuterol is forbidden by the World Anti-Doping Agency (WADA) in the practice of sport. This compound is of particular interest for anti-doping authorities and WADA-accredited laboratories due to the recent reporting of risk of unintentional doping following the eating of meat contaminated with traces of clenbuterol in some countries. In this work, the development and the validation of an ultra-high pressure liquid chromatography coupled to electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS) method for the quantification of clenbuterol in human urine is described. The analyte was extracted from urine samples by liquid-liquid extraction (LLE) in basic conditions using tert butyl-methyl ether (TBME) and analyzed by UHPLC-MS/MS with a linear gradient of acetonitrile in 9min only. The simple and rapid method presented here was validated in compliance with authority guidelines and showed a limit of quantification at 5pg/mL and a linearity range from 5pg/mL to 300pg/mL. Good trueness (85.8-105%), repeatability (5.7-10.6% RSD) and intermediate precision (5.9-14.9% RSD) results were obtained. The method was then applied to real samples from eighteen volunteers collecting urines after single oral doses administration (1, 5 and 10μg) of clenbuterol-enriched yogurts.
Resumo:
The Railroad Avenue groundwater contamination site (the site) is in West Des Moines, Polk County, Iowa. Located on approximately 120 acres. The site comprises mixed residential, industrial and commercial properties. Underneath the site, chlorinated volatile organic compounds (VOCs) have contaminatcd the shallow (i.e., 30-50 feet deep) groundwater. These compounds have compromised several shallow wells within the West Des Moines water works system. A contamination source, however, has not yet been identified. In 1993, routine water analysis by the City of West Des Moines identified 1, 2 cis-dichlorocthylcne (1, 2 cis-DCE) at a concentration of 1.2 μg/L (micrograms) per liter of water) in the water supply. Subsequently. several shallow municipal wells were found to be contaminated by VOCs, including 1. 2 cis-DCE, trichloroethylene (TCE), tetrachloroethylene (PCE) and benzene. Five of these wells have been taken out of service. Because of the impact on the West Des Moines water supply, the U.S. Environmental Protection Agency (USEPA) has assigned the site to the National Priorities List. Surface water und sediment at the site have not been impacted by the VOCs. Testing for VOCs in surface soils has not revealed any significant VOC contamination. Subsurface soils -- generally 8 feet or greater in depth -- are contaminated with VOCs, but at levels which should not present a health hazard. The past, present, and future health hazard category chosen for this site is no apparent public health hazard. This category is used when exposure to toxins might be occurring or might have occurrcd in the past, but at levels below any known health hazard. Analysis of available environmental data has not revealed that residental or commercial water customers are or have been exposed to VOCs at concentrations that might cause any adverse health effects.
Resumo:
A flow injection hydride generation direct current plasma atomic emission spectrometric (FI-HG-DCP-AES) method was developed for the determination of lead at ng.ml-l level. Potassium ferricyanide (K3Fe(CN)6) was used along with sodium tetrahydroborate(III) (NaBH4) to produce plumbane (PbH4) in an acid medium. The design of a gas-liquid separator (hydride generator) was tested and the parameters of the flow injection system were optimized to achieve a good detection limit and sample throughput. The technique developed gave a detection limit of 0.7 ng.ml-l(3ob). The precision at 20 ng.ml"* level was 1.6 % RSD with 1 1 measurements (n=l 1). Volume of sample loop was 500 |J.l. A sample throughput of 120 h"^ was achieved. The transition elements, Fe(II), FeOH), Cd(n), Co(II), Mn(n), Ni(II) and Zn(n) do not interfere in this method but 1 mg,l'l Cu(II) will suppress 50 % of the signal from a sample containing 20 ng.ml'l Pb. This method was successfully applied to determine lead in a calcium carbonate (CaC03) matrix of banded coral skeletons from Si-Chang Island in Thailand.
Resumo:
Microwave digestions of mercury in Standards Reference Material (SRM) coal samples with nitric acid and hydrogen peroxide in quartz vessels were compared with Teflon® vessel digestion by using flow injection cold vapor atomic absorption spectrometry. Teflon® vessels gave poor reproducibiUty and tended to deliver high values, while the digestion results from quartz vessel show good agreement with certificate values and better standard deviations. Trace level elements (Ag, Ba, Cd, Cr, Co, Cu, Fe, Mg, Mn, Mo, Pb, Sn, Ti, V and Zn) in used oil and residual oil samples were determined by inductively coupled plasma-optical emission spectrometry. Different microwave digestion programs were developed for each sample and most of the results are in good agreement with certified values. The disagreement with values for Ag was due to the precipitation of Ag in sample; while Sn, V and Zn values had good recoveries from the spike test, which suggests that these certified values might need to be reconsidered. Gold, silver, copper, cadmium, cobalt, nickel and zinc were determined by continuous hydride generation inductively coupled plasma-optical emission spectrometry. The performance of two sample introduction systems: MSIS™ and gas-liquid separator were compared. Under the respective optimum conditions, MSIS^"^ showed better sensitivity and lower detection limits for Ag, Cd, Cu, Co and similar values for Au, Ni and Zn to those for the gas-liquid separator.