949 resultados para Constant Loading Rate
Resumo:
There are presently over 182 RBC plants, treating domestic wastewater, in the Republic of Ireland, 136 of which have been installed since 1986. The use of this treatment plant technology, although not new, is becoming increasingly popular. The aim of this research was to assess the effects that a household detergent has on rotating biological contractor treatment plant efficiency. Household detergents contribute phosphorus to the surrounding environment and can also remove beneficial biomass from the disc media. A simple modification was made to a conventional flat disc unit to increase the oxygen transfer of the process. The treatment efficiency of the modified RBC (with aeration cups attached) was assessed against a parallel conventional system, with and without degergent loading. The parameters monitored were chemical oxygen demand (COD), bio-chemical oxygen demand (BOD), nitrates, phosphates, dissolved oxygen, the motors power consumption, pH, and temperature. Some microscopic analysis of the biofilm was also to be carried out. The treatment efficiency of both units was compared, based on COD/BOD removal. The degree of nitrification achievable by both units was also assessed with any fluctuations in pH noted. Monitoring of the phosphorus removal capabilities of both units was undertaken. Relationships between detergent concentrations and COD removal efficiencies were also analysed.
Resumo:
Magdeburg, Univ., Diss., Med. Fak., 2011
Resumo:
Background: When performing the Valsalva maneuver (VM), adults and preadolescents produce the same expiratory resistance values. Objective: To analyze heart rate (HR) in preadolescents performing VM, and propose a new method for selecting expiratory resistance. Method: The maximal expiratory pressure (MEP) was measured in 45 sedentary children aged 9-12 years who subsequently performed VM for 20 s using an expiratory pressure of 60%, 70%, or 80% of MEP. HR was measured before, during, and after VM. These procedures were repeated 30 days later, and the data collected in the sessions (E1, E2) were analyzed and compared in periods before, during (0-10 and 10-20 s), and after VM using nonparametric tests. Results: All 45 participants adequately performed VM in E1 and E2 at 60% of MEP. However, only 38 (84.4%) and 25 (55.5%) of the participants performed the maneuver at 70% and 80% of MEP, respectively. The HR delta measured during 0-10 s and 10-20 s significantly increased as the expiratory effort increased, indicating an effective cardiac autonomic response during VM. However, our findings suggest the VM should not be performed at these intensities. Conclusion: HR increased with all effort intensities tested during VM. However, 60% of MEP was the only level of expiratory resistance that all participants could use to perform VM. Therefore, 60% of MEP may be the optimal expiratory resistance that should be used in clinical practice.
Resumo:
Background: Heart rate variability (HRV) is a marker of autonomic dysfunction severity. The effects of physical training on HRV indexes in Chagas heart disease (CHD) are not well established. Objective: To evaluate the changes in HRV indexes in response to physical training in CHD. Methods: Patients with CHD and left ventricular (LV) dysfunction, physically inactive, were randomized either to the intervention (IG, N = 18) or control group (CG, N = 19). The IG participated in a 12-week exercise program consisting of 3 sessions/week. Results: Mean age was 49.5 ± 8 years, 59% males, mean LVEF was 36.3 ± 7.8%. Baseline HRV indexes were similar between groups. From baseline to follow-up, total power (TP): 1653 (IQ 625 - 3418) to 2794 (1617 - 4452) ms, p = 0.02) and very low frequency power: 586 (290 - 1565) to 815 (610 - 1425) ms, p = 0.047) increased in the IG, but not in the CG. The delta (post - pre) HRV indexes were similar: SDNN 11.5 ± 30.0 vs. 3.7 ± 25.1 ms. p = 0.10; rMSSD 2 (6 - 17) vs. 1 (21 - 9) ms. p = 0.43; TP 943 (731 - 3130) vs. 1780 (921 - 2743) Hz. p = 0.46; low frequency power (LFP) 1.0 (150 - 197) vs. 60 (111 - 146) Hz. p = 0.85; except for high frequency power, which tended to increase in the IG: 42 (133 - 92) vs. 79 (61 - 328) Hz. p = 0.08). Conclusion: In the studied population, the variation of HRV indexes was similar between the active and inactive groups. Clinical improvement with physical activity seems to be independent from autonomic dysfunction markers in CHD.
Resumo:
Background: Ivabradine is a novel specific heart rate (HR)-lowering agent that improves event-free survival in patients with heart failure (HF). Objectives: We aimed to evaluate the effect of ivabradine on time domain indices of heart rate variability (HRV) in patients with HF. Methods: Forty-eight patients with compensated HF of nonischemic origin were included. Ivabradine treatment was initiated according to the latest HF guidelines. For HRV analysis, 24-h Holter recording was obtained from each patient before and after 8 weeks of treatment with ivabradine. Results: The mean RR interval, standard deviation of all normal to normal RR intervals (SDNN), the standard deviation of 5-min mean RR intervals (SDANN), the mean of the standard deviation of all normal-to-normal RR intervals for all 5-min segments (SDNN index), the percentage of successive normal RR intervals exceeding 50 ms (pNN50), and the square root of the mean of the squares of the differences between successive normal to normal RR intervals (RMSSD) were low at baseline before treatment with ivabradine. After 8 weeks of treatment with ivabradine, the mean HR (83.6 ± 8.0 and 64.6 ± 5.8, p < 0.0001), mean RR interval (713 ± 74 and 943 ± 101 ms, p < 0.0001), SDNN (56.2 ± 15.7 and 87.9 ± 19.4 ms, p < 0.0001), SDANN (49.5 ± 14.7 and 76.4 ± 19.5 ms, p < 0.0001), SDNN index (24.7 ± 8.8 and 38.3 ± 13.1 ms, p < 0.0001), pNN50 (2.4 ± 1.6 and 3.2 ± 2.2 %, p < 0.0001), and RMSSD (13.5 ± 4.6 and 17.8 ± 5.4 ms, p < 0.0001) substantially improved, which sustained during both when awake and while asleep. Conclusion: Our findings suggest that treatment with ivabradine improves HRV in nonischemic patients with HF.
Resumo:
Background:Autonomic dysfunction (AD) is highly prevalent in hemodialysis (HD) patients and has been implicated in their increased risk of cardiovascular mortality.Objective:To correlate heart rate variability (HRV) during exercise treadmill test (ETT) with the values obtained when measuring functional aerobic impairment (FAI) in HD patients and controls.Methods:Cross-sectional study involving HD patients and a control group. Clinical examination, blood sampling, transthoracic echocardiogram, 24-hour Holter, and ETT were performed. A symptom-limited ramp treadmill protocol with active recovery was employed. Heart rate variability was evaluated in time domain at exercise and recovery periods.Results:Forty-one HD patients and 41 controls concluded the study. HD patients had higher FAI and lower HRV than controls (p<0.001 for both). A correlation was found between exercise HRV (SDNN) and FAI in both groups. This association was independent of age, sex, smoking, body mass index, diabetes, and clonidine or beta-blocker use, but not of hemoglobin levels.Conclusion:No association was found between FAI and HRV on 24-hour Holter or at the recovery period of ETT. Of note, exercise HRV was inversely correlated with FAI in HD patients and controls. (Arq Bras Cardiol. 2015; [online]. ahead print, PP.0-0)
Resumo:
Background:Diabetes affects approximately 250 million people in the world. Cardiovascular autonomic neuropathy is a common complication of diabetes that leads to severe postural hypotension, exercise intolerance, and increased incidence of silent myocardial infarction.Objective:To determine the variability of heart rate (HR) and systolic blood pressure (SBP) in recently diagnosed diabetic patients.Methods:The study included 30 patients with a diagnosis of type 2 diabetes of less than 2 years and 30 healthy controls. We used a Finapres® device to measure during five minutes beat-to-beat HR and blood pressure in three experimental conditions: supine position, standing position, and rhythmic breathing at 0.1 Hz. The results were analyzed in the time and frequency domains.Results:In the HR analysis, statistically significant differences were found in the time domain, specifically on short-term values such as standard deviation of NN intervals (SDNN), root mean square of successive differences (RMSSD), and number of pairs of successive NNs that differ by more than 50 ms (pNN50). In the BP analysis, there were no significant differences, but there was a sympathetic dominance in all three conditions. The baroreflex sensitivity (BRS) decreased in patients with early diabetes compared with healthy subjects during the standing maneuver.Conclusions:There is a decrease in HR variability in patients with early type 2 diabetes. No changes were observed in the BP analysis in the supine position, but there were changes in BRS with the standing maneuver, probably due to sympathetic hyperactivity.
Lowering Pulmonary Wedge Pressure after Heart Transplant: Pulmonary Compliance and Resistance Effect
Resumo:
AbstractBackground:Right ventricular (RV) afterload is an important risk factor for post-heart transplantation (HTx) mortality, and it results from the interaction between pulmonary vascular resistance (PVR) and pulmonary compliance (CPA). Their product, the RC time, is believed to be constant. An exception is observed in pulmonary hypertension because of elevated left ventricular (LV) filling pressures.Objective:Using HTx as a model for chronic lowering of LV filling pressures, our aim was to assess the variations in RV afterload components after transplantation.Methods:We retrospectively studied 159 patients with right heart catheterization before and after HTx. The effect of Htx on hemodynamic variables was assessed.Results:Most of the patients were male (76%), and the mean age was 53 ± 12 years. HTx had a significant effect on the hemodynamics, with normalization of the LV and RV filling pressures and a significant increase in cardiac output and heart rate (HR). The PVR decreased by 56% and CPA increased by 86%. The RC time did not change significantly, instead of increasing secondary to pulmonary wedge pressure (PWP) normalization after HTx as expected. The expected increase in RC time with PWP lowering was offset by the increase in HR (because of autonomic denervation of the heart). This effect was independent from the decrease of PWP.Conclusion:The RC time remained unchanged after HTx, notwithstanding the fact that pulmonary capillary wedge pressure significantly decreased. An increased HR may have an important effect on RC time and RV afterload. Studying these interactions may be of value to the assessment of HTx candidates and explaining early RV failure after HTx.
Resumo:
Abstract Background: Recent studies have shown changes in cardiac autonomic control of obese preadolescents. Objective: To assess the heart rate responses and cardiac autonomic modulation of obese preadolescents during constant expiratory effort. Methods: This study assessed 10 obese and 10 non-obese preadolescents aged 9 to 12 years. The body mass index of the obese group was between the 95th and 97th percentiles of the CDC National Center for Health Statistics growth charts, while that of the non-obese group, between the 5th and 85th percentiles. Initially, they underwent anthropometric and clinical assessment, and their maximum expiratory pressures were obtained. Then, the preadolescents underwent a constant expiratory effort of 70% of their maximum expiratory pressure for 20 seconds, with heart rate measurement 5 minutes before, during and 5 minutes after it. Heart rate variability (HRV) and heart rate values were analyzed by use of a software. Results: The HRV did not differ when compared before and after the constant expiratory effort intra- and intergroup. The heart rate values differed (p < 0.05) during the effort, being the total variation in non-obese preadolescents of 18.5 ± 1.5 bpm, and in obese, of 12.2 ± 1.3 bpm. Conclusion: The cardiac autonomic modulation did not differ between the groups when comparing before and after the constant expiratory effort. However, the obese group showed lower cardiovascular response to baroreceptor stimuli during the effort, suggesting lower autonomic baroreflex sensitivity.
Resumo:
Abstract Background: Studies have questioned the downward trend in mortality from cardiovascular diseases (CVD) in Brazil in recent years. Objective: to analyze recent trends in mortality from ischemic heart disease (IHD) and stroke in the Brazilian population. Methods: Mortality and population data were obtained from the Brazilian Institute of Geography and Statistics and the Ministry of Health. Risk of death was adjusted by the direct method, using as reference the world population of 2000. We analyzed trends in mortality from CVD, IHD and stroke in women and men in the periods of 1980-2006 and 2007-2012. Results: there was a decrease in CVD mortality and stroke in women and men for both periods (p < 0.001). Annual mortality variations for periods 1980-2006 and 2007-2012 were, respectively: CVD (total): -1.5% and -0.8%; CVD men: -1.4% and -0.6%; CVD women: -1.7% and -1.0%; DIC (men): -1.1% and 0.1%; stroke (men): -1.7% and -1.4%; DIC (women): -1.5% and 0.4%; stroke (women): -2.0% and -1.9%. From 1980 to 2006, there was a decrease in IHD mortality in men and women (p < 0.001), but from 2007 to 2012, changes in IHD mortality were not significant in men [y = 151 + 0.04 (R2 = 0.02; p = 0.779)] and women [y = 88-0.54 (R2 = 0.24; p = 0.320). Conclusion: Trend in mortality from IHD stopped falling in Brazil from 2007 to 2012.
Resumo:
This paper devotes to evaluation of performance bottlenecks and algorithm deficiencies in the area of contemporary reliable multicast networking. Hereby, the impact of packet delay jitter on the end-to-end performance of multicast IP data transport is investigated. A series of tests with two most significant open-source implementations of reliable multicast is performed and analyzed. These are: UDP-based File Transfer Protocol (UFTP) and NACK-oriented Reliable multicast (NORM). Tests were targeted to simulate scenario of content distribution in WAN – sized Content Delivery Networks (CDN). Then, results were grouped and averaged, by round trip time and packet losses. This enabled us to see jitter influence independently on round trip time(RTT) and packet loss rates. Revealed jitter influence for different network conditions. Confirmed, that appearance of even small jitter causes significant data rate reduction.
Resumo:
Nowadays a huge attention of the academia and research teams is attracted to the potential of the usage of the 60 GHz frequency band in the wireless communications. The use of the 60GHz frequency band offers great possibilities for wide variety of applications that are yet to be implemented. These applications also imply huge implementation challenges. Such example is building a high data rate transceiver which at the same time would have very low power consumption. In this paper we present a prototype of Single Carrier -SC transceiver system, illustrating a brief overview of the baseband design, emphasizing the most important decisions that need to be done. A brief overview of the possible approaches when implementing the equalizer, as the most complex module in the SC transceiver, is also presented. The main focus of this paper is to suggest a parallel architecture for the receiver in a Single Carrier communication system. This would provide higher data rates that the communication system canachieve, for a price of higher power consumption. The suggested architecture of such receiver is illustrated in this paper,giving the results of its implementation in comparison with its corresponding serial implementation.
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2015