874 resultados para Computer Supported Cooperative Work (CSCW)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Loss, grief and other problems are events that most of people experience them during their Life. The earthquake is a disaster that makes people experience loss, grief and problems simultaneously. This crisis affects on survivors as much as they face to dangers in their lives. Thus, most of them need to being supported until they can solve their problems, be relaxed and do their daily activities. We know that the profession of social workers is to assist individuals who are seeking help. But there is a Problem, how do they help the clients efficiently? Especially, those clients who have suffered earthquake. Generally, the role of social workers in helping the survivors of earthquake is significant. To this end, the present paper tries to describe the process of social casework and those skills required for social workers to help the survivors. These skills include: situational supporting, hopefulness making, consoling, assuring, concentrating, solutions developing and refer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article addresses the issue of kriging-based optimization of stochastic simulators. Many of these simulators depend on factors that tune the level of precision of the response, the gain in accuracy being at a price of computational time. The contribution of this work is two-fold: first, we propose a quantile-based criterion for the sequential design of experiments, in the fashion of the classical expected improvement criterion, which allows an elegant treatment of heterogeneous response precisions. Second, we present a procedure for the allocation of the computational time given to each measurement, allowing a better distribution of the computational effort and increased efficiency. Finally, the optimization method is applied to an original application in nuclear criticality safety. This article has supplementary material available online. The proposed criterion is available in the R package DiceOptim.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There has been significant interest in indirect measures of attitudes like the Implicit Association Test (IAT), presumably because of the possibility of uncovering implicit prejudices. The authors derived a set of qualitative predictions for people's performance in the IAT on the basis of random walk models. These were supported in 3 experiments comparing clearly positive or negative categories to nonwords. They also provided evidence that participants shift their response criterion when doing the IAT. Because of these criterion shifts, a response pattern in the IAT can have multiple causes. Thus, it is not possible to infer a single cause (such as prejudice) from IAT results. A surprising additional result was that nonwords were treated as though they were evaluated more negatively than obviously negative items like insects, suggesting that low familiarity items may generate the pattern of data previously interpreted as evidence for implicit prejudice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To compare the precision of fit of full-arch implant-supported screw-retained computer-aided designed and computer-aided manufactured (CAD/CAM) titanium-fixed dental prostheses (FDP) before and after veneering. The null-hypothesis was that there is no difference in vertical microgap values between pure titanium frameworks and FDPs after porcelain firing. MATERIALS AND METHODS Five CAD/CAM titanium grade IV frameworks for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI tooth positions 15, 13, 11, 21, 23, 25) were fabricated after digitizing the implant platforms and the cuspid-supporting framework resin pattern with a laser scanner (CARES(®) Scan CS2; Institut Straumann AG, Basel, Switzerland). A bonder, an opaquer, three layers of porcelain, and one layer of glaze were applied (Vita Titankeramik) and fired according to the manufacturer's preheating and fire cycle instructions at 400-800°C. The one-screw test (implant 25 screw-retained) was applied before and after veneering of the FDPs to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from interproximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS All vertical microgaps were clinically acceptable with values <90 μm. No statistically significant pairwise difference (P = 0.98) was observed between the relative effects of vertical microgap of unveneered (median 19 μm; 95% CI 13-35 μm) and veneered FDPs (20 μm; 13-31 μm), providing support for the null-hypothesis. Analysis within the groups showed significantly different values between the five implants of the FDPs before (P = 0.044) and after veneering (P = 0.020), while a monotonous trend of increasing values from implant 23 (closest position to screw-retained implant 25) to 15 (most distant implant) could not be observed (P = 0.169, P = 0.270). CONCLUSIONS Full-arch CAD/CAM titanium screw-retained frameworks have a high accuracy. Porcelain firing procedure had no impact on the precision of fit of the final FDPs. All implant microgap measurements of each FDP showed clinically acceptable vertical misfit values before and after veneering. Thus, the results do not only show accurate performance of the milling and firing but show also a reproducible scanning and designing process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Task-oriented, repetitive and intensive arm training can enhance arm rehabilitation in patients with paralyzed upper extremities due to lesions of the central nervous system. There is evidence that the training duration is a key factor for the therapy progress. Robot-supported therapy can improve the rehabilitation allowing more intensive training. This paper presents the kinematics, the control and the therapy modes of the arm therapy robot ARMin. It is a haptic display with semi-exoskeleton kinematics with four active and two passive degrees of freedom. Equipped with position, force and torque sensors the device can deliver patient-cooperative arm therapy taking into account the activity of the patient and supporting him/her only as much as needed. The haptic display is combined with an audiovisual display that is used to present the movement and the movement task to the patient. It is assumed that the patient-cooperative therapy approach combined with a multimodal display can increase the patient's motivation and activity and, therefore, the therapeutic progress.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We review our recent work on protein-ligand interactions in vitamin transporters of the Sec-14-like protein. Our studies focused on the cellular-retinaldehyde binding protein (CRALBP) and the alpha-tocopherol transfer protein (alpha-TTP). CRALBP is responsible for mobilisation and photo-protection of short-chain cis-retinoids in the dim-light visual cycle or rod photoreceptors. alpha-TTP is a key protein responsible for selection and retention of RRR-alpha-tocopherol, the most active isoform of vitamin E in superior animals. Our simulation studies evidence how subtle chemical variations in the substrate can lead to significant distortion in the structure of the complex, and how these changes can either lead to new protein function, or be used to model engineered protein variants with tailored properties. Finally, we show how integration of computational and experimental results can contribute in synergy to the understanding of fundamental processes at the biomolecular scale.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The aim of this case series was to introduce a complete digital workflow for the production of monolithic implant crowns. MATERIAL AND METHODS Six patients were treated with implant-supported crowns made of resin nano ceramic (RNC). Starting with an intraoral optical scan (IOS), and following a CAD/CAM process, the monolithic crowns were bonded either to a novel prefabricated titanium abutment base (group A) or to a CAD/CAM-generated individualized titanium abutment (group B) in premolar or molar sites on a soft tissue level dental implant. Economic analyses included clinical and laboratory steps. An esthetic evaluation was performed to compare the two abutment-crown combinations. RESULTS None of the digitally constructed RNC crowns required any clinical adaptation. Overall mean work time calculations revealed obvious differences for group A (65.3 min) compared with group B (86.5 min). Esthetic analysis demonstrated a more favorable outcome for the prefabricated bonding bases. CONCLUSIONS Prefabricated or individualized abutments on monolithic RNC crowns using CAD/CAM technology in a model-free workflow seem to provide a feasible and streamlined treatment approach for single-edentulous space rehabilitation in the posterior region. However, RNC as full-contour material has to be considered experimental, and further large-scale clinical investigations with long-term follow-up observation are necessary.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To evaluate technical complications and failures of zirconia-based fixed prostheses supported by implants. MATERIALS AND METHODS Consecutive patients received zirconia-based single crowns (SCs) and fixed dental prostheses (FDPs) on implants in a private clinical setting between 2005 and 2010. One dentist performed all surgical and prosthetic procedures, and one master technician performed and coordinated all laboratory procedures. One-piece computer-aided design/ computer-assisted manufacture technology was used to fabricate abutments and frameworks, which were directly connected at the implant level, where possible. All patients were involved in a recall maintenance program and were finally reviewed in 2012. Data on framework fractures, chipping of veneering ceramics, and other technical complications were recorded. The primary endpoint was failure of the prostheses, ie, the need for a complete remake. A life table analysis was calculated. RESULTS A total of 289 implants supported 193 zirconia-based prostheses (120 SCs and 73 FDPs) in 127 patients (51 men, 76 women; average age: 62.5 ± 13.4 years) who were reviewed in 2012. Twenty-five (13%) prostheses were cemented on 44 zirconia abutments and 168 (87%) prostheses were screw-retained directly at the implant level. Fracture of 3 frameworks (1 SC, 2 FDPs) was recorded, and significant chipping resulted in the remake of 3 prostheses (1 SC, 2 FDPs). The 7-year cumulative survival rate was 96.4% ± 1.99%. Minor complications comprised 5 loose screws (these were retightened), small chips associated with 3 prostheses (these were polished), and dislodgement of 3 prostheses (these were recemented). Overall, 176 prostheses remained free of technical problems. CONCLUSIONS Zirconia-based prostheses screwed directly to implants are clinically successful in the short and medium term.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective The individual placement and support model of supported employment has been shown to be more effective than other vocational approaches in improving competitive work over 1-2 years in persons with severe mental illness. The authors evaluated the longer-term effects of the model compared with traditional vocational rehabilitation over 5 years. Method A randomized controlled trial compared supported employment to traditional vocational rehabilitation in 100 unemployed persons with severe mental illness. Competitive work and hospital admissions were tracked for 5 years, and interviews were conducted at 2 and 5 years to assess recovery attitudes and quality of life. A cost-benefit analysis compared program and total treatment costs to earnings from competitive employment. Results The beneficial effects of supported employment on work at 2 years were sustained over the 5-year follow-up period. Participants in supported employment were more likely to obtain competitive work than those in traditional vocational rehabilitation (65% compared with 33%), worked more hours and weeks, earned more wages, and had longer job tenures. Reliance on supported employment services for retaining competitive work decreased from 2 years to 5 years for participants in supported employment. Participants were also significantly less likely to be hospitalized, had fewer psychiatric hospital admissions, and spent fewer days in the hospital. The social return on investment was higher for supported employment participants, whether calculated as the ratio of work earnings to vocational program costs or of work earnings to total vocational program and mental health treatment costs. Conclusions The results demonstrate that the greater effectiveness of supported employment in improving competitive work outcomes is sustained beyond 2 years and suggest that supported employment programs contribute to reduced hospitalizations and produce a higher social return on investment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE The objective of this study was to evaluate stiffness, strength, and failure modes of monolithic crowns produced using computer-aided design/computer-assisted manufacture, which are connected to diverse titanium and zirconia abutments on an implant system with tapered, internal connections. MATERIALS AND METHODS Twenty monolithic lithium disilicate (LS2) crowns were constructed and loaded on bone level-type implants in a universal testing machine under quasistatic conditions according to DIN ISO 14801. Comparative analysis included a 2 × 2 format: prefabricated titanium abutments using proprietary bonding bases (group A) vs nonproprietary bonding bases (group B), and customized zirconia abutments using proprietary Straumann CARES (group C) vs nonproprietary Astra Atlantis (group D) material. Stiffness and strength were assessed and calculated statistically with the Wilcoxon rank sum test. Cross-sections of each tested group were inspected microscopically. RESULTS Loaded LS2 crowns, implants, and abutment screws in all tested specimens (groups A, B, C, and D) did not show any visible fractures. For an analysis of titanium abutments (groups A and B), stiffness and strength showed equally high stability. In contrast, proprietary and nonproprietary customized zirconia abutments exhibited statistically significant differences with a mean strength of 366 N (Astra) and 541 N (CARES) (P < .05); as well as a mean stiffness of 884 N/mm (Astra) and 1,751 N/mm (CARES) (P < .05), respectively. Microscopic cross-sections revealed cracks in all zirconia abutments (groups C and D) below the implant shoulder. CONCLUSION Depending on the abutment design, prefabricated titanium abutment and proprietary customized zirconia implant-abutment connections in conjunction with monolithic LS2 crowns had the best results in this laboratory investigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To compare time-efficiency in the production of implant crowns using a digital workflow versus the conventional pathway. MATERIALS AND METHODS This prospective clinical study used a crossover design that included 20 study participants receiving single-tooth replacements in posterior sites. Each patient received a customized titanium abutment plus a computer-aided design/computer-assisted manufacture (CAD/CAM) zirconia suprastructure (for those in the test group, using digital workflow) and a standardized titanium abutment plus a porcelain-fused-to-metal crown (for those in the control group, using a conventional pathway). The start of the implant prosthetic treatment was established as the baseline. Time-efficiency analysis was defined as the primary outcome, and was measured for every single clinical and laboratory work step in minutes. Statistical analysis was calculated with the Wilcoxon rank sum test. RESULTS All crowns could be provided within two clinical appointments, independent of the manufacturing process. The mean total production time, as the sum of clinical plus laboratory work steps, was significantly different. The mean ± standard deviation (SD) time was 185.4 ± 17.9 minutes for the digital workflow process and 223.0 ± 26.2 minutes for the conventional pathway (P = .0001). Therefore, digital processing for overall treatment was 16% faster. Detailed analysis for the clinical treatment revealed a significantly reduced mean ± SD chair time of 27.3 ± 3.4 minutes for the test group compared with 33.2 ± 4.9 minutes for the control group (P = .0001). Similar results were found for the mean laboratory work time, with a significant decrease of 158.1 ± 17.2 minutes for the test group vs 189.8 ± 25.3 minutes for the control group (P = .0001). CONCLUSION Only a few studies have investigated efficiency parameters of digital workflows compared with conventional pathways in implant dental medicine. This investigation shows that the digital workflow seems to be more time-efficient than the established conventional production pathway for fixed implant-supported crowns. Both clinical chair time and laboratory manufacturing steps could be effectively shortened with the digital process of intraoral scanning plus CAD/CAM technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Recent technical development allows the digital manufacturing of monolithic reconstructions with high-performance materials. For implant-supported crowns, the fixation requires an abutment design onto which the reconstruction can be bonded. PURPOSE The aim of this laboratory investigation was to analyze stiffness, strength, and failure modes of implant-supported, computer-assisted design and computer-aided manufacturing (CAD/CAM)-generated resin nano ceramic (RNC) crowns bonded to three different titanium abutments. MATERIALS AND METHODS Eighteen monolithic RNC crowns were produced and loaded in a universal testing machine under quasi-static condition according to DIN ISO 14801. With regard to the type of titanium abutment, three groups were defined: (1) prefabricated cementable standard; (2) CAD/CAM-constructed individualized; and (3) novel prefabricated bonding base. Stiffness and strength were measured and analyzed statistically with Wilcoxon rank sum test. Sections of the specimens were examined microscopically. RESULTS Stiffness demonstrated high stability for all specimens loaded in the physiological loading range with means and standard deviations of 1,579 ± 120 N/mm (group A), 1,733 ± 89 N/mm (group B), and 1,704 ± 162 N/mm (group C). Mean strength of the novel prefabricated bonding base (group C) was 17% lower than of the two other groups. Plastic deformations were detectable for all implant-abutment crown connections. CONCLUSIONS Monolithic implant crowns made of RNC seem to represent a feasible and stable prosthetic construction under laboratory testing conditions with strength higher than the average occlusal force, independent of the different abutment designs used in this investigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Implant-overdentures supported by rigid bars provide stability in the edentulous atrophic mandible. However, fractures of solder joints and matrices, and loosening of screws and matrices were observed with soldered gold bars (G-bars). Computer-aided designed/computer-assisted manufactured (CAD/CAM) titanium bars (Ti-bars) may reduce technical complications due to enhanced material quality. PURPOSE To compare prosthetic-technical maintenance service of mandibular implant-overdentures supported by CAD/CAM Ti-bar and soldered G-bar. MATERIALS AND METHODS Edentulous patients were consecutively admitted for implant-prosthodontic treatment with a maxillary complete denture and a mandibular implant-overdenture connected to a rigid G-bar or Ti-bar. Maintenance service and problems with the implant-retention device complex and the prosthesis were recorded during minimally 3-4 years. Annual peri-implant crestal bone level changes (ΔBIC) were radiographically assessed. RESULTS Data of 213 edentulous patients (mean age 68 ± 10 years), who had received a total of 477 tapered implants, were available. Ti-bar and G-bar comprised 101 and 112 patients with 231 and 246 implants, respectively. Ti-bar mostly exhibited distal bar extensions (96%) compared to 34% of G-bar (p < .001). Fracture rate of bars extensions (4.7% vs 14.8%, p < .001) and matrices (1% vs 13%, p < .001) was lower for Ti-bar. Matrices activation was required 2.4× less often in Ti-bar. ΔBIC remained stable for both groups. CONCLUSIONS Implant overdentures supported by soldered gold bars or milled CAD/CAM Ti-bars are a successful treatment modality but require regular maintenance service. These short-term observations support the hypothesis that CAD/CAM Ti-bars reduce technical complications. Fracture location indicated that the titanium thickness around the screw-access hole should be increased.