983 resultados para Compressor valve
Resumo:
CONTEXT: Infection of implantable cardiac devices is an emerging disease with significant morbidity, mortality, and health care costs. OBJECTIVES: To describe the clinical characteristics and outcome of cardiac device infective endocarditis (CDIE) with attention to its health care association and to evaluate the association between device removal during index hospitalization and outcome. DESIGN, SETTING, AND PATIENTS: Prospective cohort study using data from the International Collaboration on Endocarditis-Prospective Cohort Study (ICE-PCS), conducted June 2000 through August 2006 in 61 centers in 28 countries. Patients were hospitalized adults with definite endocarditis as defined by modified Duke endocarditis criteria. MAIN OUTCOME MEASURES: In-hospital and 1-year mortality. RESULTS: CDIE was diagnosed in 177 (6.4% [95% CI, 5.5%-7.4%]) of a total cohort of 2760 patients with definite infective endocarditis. The clinical profile of CDIE included advanced patient age (median, 71.2 years [interquartile range, 59.8-77.6]); causation by staphylococci (62 [35.0% {95% CI, 28.0%-42.5%}] Staphylococcus aureus and 56 [31.6% {95% CI, 24.9%-39.0%}] coagulase-negative staphylococci); and a high prevalence of health care-associated infection (81 [45.8% {95% CI, 38.3%-53.4%}]). There was coexisting valve involvement in 66 (37.3% [95% CI, 30.2%-44.9%]) patients, predominantly tricuspid valve infection (43/177 [24.3%]), with associated higher mortality. In-hospital and 1-year mortality rates were 14.7% (26/177 [95% CI, 9.8%-20.8%]) and 23.2% (41/177 [95% CI, 17.2%-30.1%]), respectively. Proportional hazards regression analysis showed a survival benefit at 1 year for device removal during the initial hospitalization (28/141 patients [19.9%] who underwent device removal during the index hospitalization had died at 1 year, vs 13/34 [38.2%] who did not undergo device removal; hazard ratio, 0.42 [95% CI, 0.22-0.82]). CONCLUSIONS: Among patients with CDIE, the rate of concomitant valve infection is high, as is mortality, particularly if there is valve involvement. Early device removal is associated with improved survival at 1 year.
Resumo:
Lutzomyia longipalpis females received single and mixed infections with Endotrypanum and Leishmania. Two biological parameters were analyzed: the percentage of infected females and the distribution of flagellates in the gut of the females. The principal comparisons were performed between (1) two strains of Endotrypanum, (2) cloned versus primary sample of one strain of Endotrypanum, (3) Endotrypanum versus Leishmania guyanensis, and (4) the pattern of flagellates behaviour by optical microscopy in females with single or mixed infection versus the identification of parasites isolated from digestive tracts by isoenzyme electrophoresis. Flagellates of Endotrypanum showed distinct patterns of infection suggesting that there is variation between and within strains. The distribution of Endotrypanum and L. guyanensis differed significantly in relation to the colonization of the stomodeal valve. In co-infection with L. guyanensis, a large number of flagellates were seen to be plentifully infecting the stomodeal valve in significantly more specimens than in females infected by Endotrypanum only. However, the electrophoretic profiles of isoenzymes of parasites recovered from all co-infected specimens corresponded to Endotrypanum. This suggests that the mere correlation sand fly infection-biochemical analysis of isolates may induce parasitological incorrect consideration.
Resumo:
Rapport de synthèse : Mesures de l'aorte ascendante par scanner synchronisé au rythme cardiaque: une étude pilote pour établir des valeurs normatives dans le cadre des futures thérapies par transcathéter. Objectif : L'objectif de cette étude est d'établir les valeurs morphométriques normatives de l'aorte ascendante à l'aide de l'angiographie par scanner synchronisé au rythme cardiaque, afin d'aider au développement des futurs traitements par transcathéter. Matériels et méthodes : Chez soixante-dix-sept patients (âgé de 22 à 83 ans, âge moyen: 54,7 ans), une angiographie par scanner synchronisé au rythme cardiaque a été réalisée pour évaluation des vaisseaux coronaires. Les examens ont été revus afin d'étudier l'anatomie de la chambre de chasse du ventricule gauche jusqu'au tronc brachio-céphalique droit. A l'aide de programmes de reconstructions multiplanaires et de segmentation automatique, différents diamètres et longueurs considérés comme importants pour les futurs traitements par transcathéter ont été mesurés. Les valeurs sont exprimées en moyennes, médianes, maximums, minimums, écart-types et en coefficients de variation. Les variations de diamètre de l'aorte ascendante durant le cycle cardiaque ont été aussi considérées. Résultats : Le diamètre moyen de la chambre de chasse du ventricule gauche était de 20.3+/-3.4 mm. Au niveau du sinus coronaire de l'aorte, il était de 34.2+/-4.1 mm et au niveau de la jonction sinotubulaire il était de 29.7+/-3.4 mm. Le diamètre moyen de l'aorte ascendante était de 32.7+/-3.8 mm. Le coefficient de variation de ces mesures variait de 12 à 17%. La distance moyenne entre l'insertion proximale des valvules aortiques et le départ du tronc brachio-céphalique droit était de 92.6+/-11.8 mm. La distance moyenne entre l'insertion proximale des valvules aortiques et l'origine de l'artère coronaire proximale était de 12.1+/-3.7 mm avec un coefficient de variation de 31%. La distance moyenne entre les deux ostia coronaires était de 7.2+/-3.1 mm avec un coefficient de variation de 43%. La longueur moyenne du petit arc de l'aorte ascendante entre l'artère coronaire gauche et le tronc brachio-céphalique droit était de 52.9+/-9.5 mm. La longueur moyenne de la continuité fibreuse entre la valve aortique et la valvule mitrale antérieure était de 14.6+/-3.3 mm avec un coefficient de variation de 23%. L'aire moyenne de la valve aortique était de 582.0+/-131.9 mm2. La variation du diamètre antéro-postérieur et transverse de l'aorte ascendante était respectivement de 8.4% et de 7.3%. Conclusion Il existe d'importantes variations inter-individuelles dans les mesures de l'aorte ascendante avec cependant des variations intra-individuelles faibles durant le cycle cardiaque. De ce fait, une approche personnalisée pour chaque patient est recommandée dans la confection des futures endoprothèses de l'aorte ascendante. Le scanner synchronisé au rythme cardiaque jouera un rôle prépondérant dans le bilan préthérapeutique. Abstract : The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3+/-3.4, coronary sinus 34.2+/-4.1, sinotubular junction 29.7+-3.4 and mid ascending aorta 32.7+/-3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6111.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1+/-3.7, and between both coronary ostia 7.2+/-3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 X9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.óf3.3, CV 13-43%. Mean aortic valve area was 582+-131.9 mm2. The variations of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.
Resumo:
OBJECTIVE: Assess the performance of self-expanding venous cannulas for routine use in open-heart surgery. METHODS: Prospective study in 100 unselected consecutive patients undergoing open-heart surgery with either remote or central smart venous cannulation. RESULTS: The study focuses on the 76 consecutive adult patients (mean age 59.2+/-17.3 years; 60 males, 16 females) undergoing surgical procedures with total cardiopulmonary bypass for either valve procedures (42/76 patients=55.3%), ascending aorta and arch repair (20/76 patients=26.3%), coronary artery revascularization (13/76 patients=17.1%) or other procedures (11/76 patients=14.5%) with 14/76 patients (18.4%) undergoing redo surgery and 6/76 patients (7.9%) undergoing small access surgery. The mean pump flow achieved by gravity drainage alone accounted for 5.0+/-0.6l/min (=114% of target) in the entire study population (n=76) as compared to the calculated, theoretical pump flow of 4.4+/-0.5l/min (p<0.0001). For the femoral cannulation sub-group (n=35) pump flow achieved by gravity drainage alone accounted for 4.9+/-0.6l/min (=114% of target) as compared to the calculated theoretical pump flow of 4.3+/-0.4l/min (p<0.0001). The corresponding numbers for trans-subclavian cannulation (n=7) are 5.2+/-0.5l/min (111%) for the pump flow achieved by gravity drainage as compared to the theoretical target flow of 4.7+/-0.4l/min. For the central cannulation sub-group (n=34) mean flow achieved by gravity drainage with a self-expanding venous cannula accounted for 5.1+/-0.7l/min (=116% of target) as compared to the calculated theoretical flow of 4.4+/-0.6l/min (p<0.0001). CONCLUSION: Full or more than target flow was achieved in 97% of the patients studied undergoing CPB with self-expanding venous cannulas and gravity drainage. Remote venous cannulation with self-expanding cannulas provides similar flows as central cannulation. Augmentation of venous return is no longer necessary.
Resumo:
The contribution of respiratory muscle work to the development of the O(2) consumption (Vo(2)) slow component is a point of controversy because it has been shown that the increased ventilation in hypoxia is not associated with a concomitant increase in Vo(2) slow component. The first purpose of this study was thus to test the hypothesis of a direct relationship between respiratory muscle work and Vo(2) slow component by manipulating inspiratory resistance. Because the conditions for a Vo(2) slow component specific to respiratory muscle can be reached during intense exercise, the second purpose was to determine whether respiratory muscles behave like limb muscles during heavy exercise. Ten trained subjects performed two 8-min constant-load heavy cycling exercises with and without a threshold valve in random order. Vo(2) was measured breath by breath by using a fast gas exchange analyzer, and the Vo(2) response was modeled after removal of the cardiodynamic phase by using two monoexponential functions. As anticipated, when total work was slightly increased with loaded inspiratory resistance, slight increases in base Vo(2), the primary phase amplitude, and peak Vo(2) were noted (14.2%, P < 0.01; 3.5%, P > 0.05; and 8.3%, P < 0.01, respectively). The bootstrap method revealed small coefficients of variation for the model parameter, including the slow-component amplitude and delay (15 and 19%, respectively), indicating an accurate determination for this critical parameter. The amplitude of the Vo(2) slow component displayed a 27% increase from 8.1 +/- 3.6 to 10.3 +/- 3.4 ml. min(-1). kg(-1) (P < 0.01) with the addition of inspiratory resistance. Taken together, this increase and the lack of any differences in minute volume and ventilatory parameters between the two experimental conditions suggest the occurrence of a Vo(2) slow component specific to the respiratory muscles in loaded condition.
Resumo:
Despite medical advances, mortality in infective endocarditis (IE) is still very high. Previous studies on prognosis in IE have observed conflicting results. The aim of this study was to identify predictors of in-hospital mortality in a large multicenter cohort of left-sided IE.Methods An observational multicenter study was conducted from January 1984 to December 2006 in seven hospitals in Andalusia, Spain. Seven hundred and five left-side IE patients were included. The main outcome measure was in-hospital mortality. Several prognostic factors were analysed by univariate tests and then by multilogistic regression model. Results.The overall mortality was 29.5% (25.5% from 1984 to 1995 and 31.9% from 1996 to 2006; Odds Ratio 1.25; 95% Confidence Interval: 0.97-1.60; p = 0.07). In univariate analysis, age, comorbidity, especially chronic liver disease, prosthetic valve, virulent microorganism such as Staphylococcus aureus, Streptococcus agalactiae and fungi, and complications (septic shock, severe heart failure, renal insufficiency, neurologic manifestations and perivalvular extension) were related with higher mortality. Independent factors for mortality in multivariate analysis were: Charlson comorbidity score (OR: 1.2; 95% CI: 1.1-1.3), prosthetic endocarditis (OR: 1.9; CI: 1.2-3.1), Staphylococcus aureus aetiology (OR: 2.1; CI: 1.3-3.5), severe heart failure (OR: 5.4; CI: 3.3-8.8), neurologic manifestations (OR: 1.9; CI: 1.2-2.9), septic shock (OR: 4.2; CI: 2.3-7.7), perivalvular extension (OR: 2.4; CI: 1.3-4.5) and acute renal failure (OR: 1.69; CI: 1.0-2.6). Conversely, Streptococcus viridans group etiology (OR: 0.4; CI: 0.2-0.7) and surgical treatment (OR: 0.5; CI: 0.3-0.8) were protective factors.Conclusions Several characteristics of left-sided endocarditis enable selection of a patient group at higher risk of mortality. This group may benefit from more specialised attention in referral centers and should help to identify those patients who might benefit from more aggressive diagnostic and/or therapeutic procedures.
Resumo:
A fish-infecting myxosporean, Henneguya hemiodopsis sp. n., found infecting the gills of Hemiodopsis microlepis and collected from the Poty River near the city of Teresina, Brazil, was described based on ultrastructural studies. The parasite occurred within large whitish polysporic plasmodia (up to 200 μm in diameter) containing asynchronous developmental sporogonic stages, mainly mature spores. The spores measured 19.7 ± 0.9 μm in total length (n = 30) and the ellipsoidal spore body was 10.8 ± 0.5 μm long, 3.3 ± 0.4 μm wide and 2.5 ± 0.5 μm thick. The spores were composed of two equal shell valves adhering together along the straight suture line, with each valve having equal-sized caudal tapering tails measuring 8.7 ± 0.6 μm in length. The spores were surrounded by a thin anastomosed network of microfibrils, more evident on the tails. There were two symmetric elongated bottle-like polar capsules 3.5 ± 0.3 μm long and 1.0 ± 0.2 μm wide, each with a polar filament with five to six coils. Given the morphological and ultrastructural differences from previously described parasites and the specificity of the host species, we propose a new species, named H. hemiodopsis sp. n.
Resumo:
The development of new medical devices, such as aortic valves, requires numerous preliminary studies on animals and training of personnel on cadavers before the devices can be used in patients. Postmortem circulation, a technique used for postmortem angiography, allows the vascular system to be reperfused in a way similar to that in living persons. This technique is used for postmortem investigations to visualize the human vascular system and to make vascular diagnoses. Specific material for reperfusing a human body was developed recently. Our aim was to investigate whether postmortem circulation that imitates in vivo conditions allows for the testing of medical materials on cadavers. We did this by delivering an aortic valve using minimally invasive methods. Postmortem circulation was established in eight corpses to recreate an environment as close as possible to in vivo conditions. Mobile fluoroscopy and a percutaneous catheterization technique were used to deliver the material to the correct place. Once the valve was implanted, the heart and primary vessels were extracted to confirm its position. Postmortem circulation proved to be essential in several of the cadavers because it helped the clinicians to deliver the material and improve their implantation techniques. Due to the intravascular circulation, sites with substantial arteriosclerotic stenosis could be bypassed, which would have been impossible without perfusion. Although originally developed for postmortem investigations, this reperfusion technique could be useful for testing new medical devices intended for living patients.
Resumo:
Hypertension and congenital aortic valve malformations are frequent causes of ascending aortic aneurysms. The molecular mechanisms of aneurysm formation under these circumstances are not well understood. Reference genes for gene activity studies in aortic tissue that are not influenced by aortic valve morphology and its hemodynamic consequences, aortic dilatation, hypertension, or antihypertensive medication are not available so far. This study determines genes in ascending aortic tissue that are independent of these parameters. Tissue specimens from dilated and undilated ascending aortas were obtained from 60 patients (age ≤70 years) with different morphologies of the aortic valve (tricuspid undilated n = 24, dilated n = 11; bicuspid undilated n = 6, dilated n = 15; unicuspid dilated n = 4). Of the studied individuals, 36 had hypertension, and 31 received ACE inhibitors or AT1 receptor antagonists. The specimens were obtained intraoperatively from the wall of the ascending aorta. We analyzed the expression levels of 32 candidate reference genes by quantitative RT-PCR (RT-qPCR). Differential expression levels were assessed by parametric statistics. The expression analysis of these 32 genes by RT-qPCR showed that EIF2B1, ELF1, and PPIA remained constant in their expression levels in the different specimen groups, thus being insensitive to aortic valve morphology, aortic dilatation, hypertension, and medication with ACE inhibitors or AT1 receptor antagonists. Unlike many other commonly used reference genes, the genes EIF2B1, ELF1, and PPIA are neither confounded by aortic comorbidities nor by antihypertensive medication and therefore are most suitable for gene expression analysis of ascending aortic tissue.
Resumo:
Mitral regurgitation (MR) involves systolic retrograde flow from the left ventricle into the left atrium. While trivial MR is frequent in healthy subjects, moderate to severe MR constitutes the second most prevalent valve disease after aortic valve stenosis. Major causes of severe MR in Western countries include degenerative valve disease (myxomatous disease, flail leaflet, annular calcification) and ischaemic heart disease, while rheumatic disease remains a major cause of MR in developing countries. Chronic MR typically progresses insidiously over many years. Once established, however, severe MR portends a poor prognosis. The severity of MR can be assessed by various techniques, Doppler echocardiography being the most widely used. Mitral valve surgery is the only treatment of proven efficacy. It alleviates clinical symptoms and prevents ventricular dilatation and heart failure (or, at least, it attenuates further progression of these abnormalities). Valve repair significantly improves clinical outcomes compared with valve replacement, reducing mortality by approximately 70%. Reverse LV remodelling after valve repair occurs in half of patients with functional MR. Percutaneous, catheter-based to mitral valve repair is a novel approach currently under clinical scrutiny, with encouraging preliminary results. This modality may provide a valuable alternative to mitral valve surgery, especially in critically ill patients.
Resumo:
We present the case studies of two adult patients with tetralogy of Fallot who were scheduled for surgery. After addressing the right ventricular outflow tract obstruction, the aorta was opened and the ventricular septal defect was approached in a straightforward manner as it was located just under the overriding aortic valve. The second patient presented with was a situs inversus, dextroapex Fallot. In this setting, the aortic approach simplified the repair expeditiously. After 2 years, both patients are in New York Heart Association class I, with no residual ventricular septal defect, no aortic regurgitation, and complete relief of right ventricular outflow tract obstruction.
Resumo:
BACKGROUND The purpose of this study was to assess the incidence of neurological complications in patients with infective endocarditis, the risk factors for their development, their influence on the clinical outcome, and the impact of cardiac surgery. METHODS AND RESULTS This was a retrospective analysis of prospectively collected data on a multicenter cohort of 1345 consecutive episodes of left-sided infective endocarditis from 8 centers in Spain. Cox regression models were developed to analyze variables predictive of neurological complications and associated mortality. Three hundred forty patients (25%) experienced such complications: 192 patients (14%) had ischemic events, 86 (6%) had encephalopathy/meningitis, 60 (4%) had hemorrhages, and 2 (1%) had brain abscesses. Independent risk factors associated with all neurological complications were vegetation size ≥3 cm (hazard ratio [HR] 1.91), Staphylococcus aureus as a cause (HR 2.47), mitral valve involvement (HR 1.29), and anticoagulant therapy (HR 1.31). This last variable was particularly related to a greater incidence of hemorrhagic events (HR 2.71). Overall mortality was 30%, and neurological complications had a negative impact on outcome (45% of deaths versus 24% in patients without these complications; P<0.01), although only moderate to severe ischemic stroke (HR 1.63) and brain hemorrhage (HR 1.73) were significantly associated with a poorer prognosis. Antimicrobial treatment reduced (by 33% to 75%) the risk of neurological complications. In patients with hemorrhage, mortality was higher when surgery was performed within 4 weeks of the hemorrhagic event (75% versus 40% in later surgery). CONCLUSIONS Moderate to severe ischemic stroke and brain hemorrhage were found to have a significant negative impact on the outcome of infective endocarditis. Early appropriate antimicrobial treatment is critical, and transitory discontinuation of anticoagulant therapy should be considered.
Resumo:
Dilatation of the ascending aorta (AAD) is a prevalent aortopathy that occurs frequently associated with bicuspid aortic valve (BAV), the most common human congenital cardiac malformation. The molecular mechanisms leading to AAD associated with BAV are still poorly understood. The search for differentially expressed genes in diseased tissue by quantitative real-time PCR (qPCR) is an invaluable tool to fill this gap. However, studies dedicated to identify reference genes necessary for normalization of mRNA expression in aortic tissue are scarce. In this report, we evaluate the qPCR expression of six candidate reference genes in tissue from the ascending aorta of 52 patients with a variety of clinical and demographic characteristics, normal and dilated aortas, and different morphologies of the aortic valve (normal aorta and normal valve n = 30; dilated aorta and normal valve n = 10; normal aorta and BAV n = 4; dilated aorta and BAV n = 8). The expression stability of the candidate reference genes was determined with three statistical algorithms, GeNorm, NormFinder and Bestkeeper. The expression analyses showed that the most stable genes for the three algorithms employed were CDKN1β, POLR2A and CASC3, independently of the structure of the aorta and the valve morphology. In conclusion, we propose the use of these three genes as reference genes for mRNA expression analysis in human ascending aorta. However, we suggest searching for specific reference genes when conducting qPCR experiments with new cohort of samples.
Resumo:
OBJECTIVE To study the factors associated with choice of therapy and prognosis in octogenarians with severe symptomatic aortic stenosis (AS). STUDY DESIGN Prospective, observational, multicenter registry. Centralized follow-up included survival status and, if possible, mode of death and Katz index. SETTING Transnational registry in Spain. SUBJECTS We included 928 patients aged ≥80 years with severe symptomatic AS. INTERVENTIONS Aortic-valve replacement (AVR), transcatheter aortic-valve implantation (TAVI) or conservative therapy. MAIN OUTCOME MEASURES All-cause death. RESULTS Mean age was 84.2 ± 3.5 years, and only 49.0% were independent (Katz index A). The most frequent planned management was conservative therapy in 423 (46%) patients, followed by TAVI in 261 (28%) and AVR in 244 (26%). The main reason against recommending AVR in 684 patients was high surgical risk [322 (47.1%)], other medical motives [193 (28.2%)], patient refusal [134 (19.6%)] and family refusal in the case of incompetent patients [35 (5.1%)]. The mean time from treatment decision to AVR was 4.8 ± 4.6 months and to TAVI 2.1 ± 3.2 months, P < 0.001. During follow-up (11.2-38.9 months), 357 patients (38.5%) died. Survival rates at 6, 12, 18 and 24 months were 81.8%, 72.6%, 64.1% and 57.3%, respectively. Planned intervention, adjusted for multiple propensity score, was associated with lower mortality when compared with planned conservative treatment: TAVI Hazard ratio (HR) 0.68 (95% confidence interval [CI] 0.49-0.93; P = 0.016) and AVR HR 0.56 (95% CI 0.39-0.8; P = 0.002). CONCLUSION Octogenarians with symptomatic severe AS are frequently managed conservatively. Planned conservative management is associated with a poor prognosis.