We report a novel method termed matrix suppressed laser desorption/ionization to improve the analysis of low-mass molecules by MALDI-TOF mass spectrometry. In this method, the surfactant of cetrimonium bromide (CTAB) is added to the conventional matrix of alpha-cyano-4-hydroxycinnamic acid solution to prepare the MALDI samples. During the MALDI process, the presence of CTAB could substantially or even completely suppress the matrix-related ion background. As a result, very clean mass spectra can be routinely obtained in the low-mass range. In addition, the presence of CTAB can significantly improve the mass resolution of low-mass molecules. It is seen that high-quality spectra were routinely obtained at a matrix/CTAB ratio of 1000:1. This method has been successfully used to analyze a variety of low-mass molecules.
Resumo:
“Dissolved” (< 0.4 μm filtered) and “total dissolvable” (unfiltered) trace element samples were collected using “clean” sampling techniques from four vertical profiles in the eastern Atlantic Ocean on the first IOC Trace Metals Baseline expedition. The analytical results obtained by 9 participating laboratories for Mn, Fe, Co, Ni, Cu, Zn, Cd, Pb, and Se on samples from station 4 in the northeast Atlantic have been evaluated with respect to accuracy and precision (intercomparability). The data variability among the reporting laboratories was expressed as 2 × SD for a given element and depth, and was comparable to the 95% confidence interval reported for the NASS seawater reference standards (representing analytical variability only). The discrepancies between reporting laboratories appear to be due to inaccuracies in standardization (analytical calibration), blank correction, and/or extraction efficiency corrections.Several of the sampling bottles used at this station were not adequately pre-cleaned (anomalous Pb results). The sample filtration process did not appear to have been a source of contamination for either dissolved or particulate trace elements. The trace metal profiles agree in general with previously reported profiles from the Atlantic Ocean. We conclude that the sampling and analytical methods we have employed for this effort, while still in need of improvement, are sufficient for obtaining accurate concentration data on most trace metals in the major water masses of the oceans, and to enable some evaluation of the biogeochemical cycling of the metals.
Resumo:
An automated and semi-intelligent voltammetric system is described for trace metal analysis. The system consists of a voltammeter interfaced with a personal computer, a sample changer, 2 peristaltic pumps, a motor burette and a hanging mercury drop electrode. The system carries out fully automatically approximately 5 metal determinations per hour (including at least 3 repetitive scans and calibration by standard addition) at trace levels encountered in clean sea water. The computer program decides what level of standard addition to use and evaluates the data prior to switching to the next sample. Alternatively, the system can be used to carry out complexing ligand titration with copper whilst recording the labile copper concentration; in this mode up to 8 full titrations are carried out per day. Depth profiles for chromium speciation in the Mediterranean Sea and a profile for copper complexing ligand concentrations in the North Atlantic Ocean measured on board-ship with the system are presented. The chromium speciation was determined using a new method to differentiate between Cr(III) and Cr(VI) utilizing adsorption of Cr(III) on silica particles.
Resumo:
Gaseous and particulate semi volatile carbonyls have been measured in urban air using an annular denuder sampling system. Three dicarbonyls, five aliphatic aldehydes and two hydroxy carbonyls were observed. Concentrations of other biogenic and anthropogenic volatile organic compounds (VOCs), SO2, CO, NO2 and particle concentration were also measured. Estimated gas-aerosol equilibrium constants for the carbonyls showed an inverse correlation with the concentrations of anthropogenic pollutants such as benzene, isopentane and SO2. This suggests that the increase in the fraction of non-polar anthropogenic particles in the atmosphere could change the average property of the ambient aerosols and drive the gas particle equilibrium of the carbonyls to the gas phase. This trend is uncommon in remote forest air. In this study, we examined the factors controlling the equilibrium in the polluted atmosphere and show that there is a difference in gas-aerosol partition between polluted and clean air.
Resumo:
在陕北黄土丘陵沟壑区对清耕和问作沙打旺(Astragalus adsurgens)6年、4年、2年仁用杏园0~500cm土层土壤水分、有机质、全氮、全磷、速效氮、速效磷、速效钾含量及树体生长状况进行了测定,结果表明,间作沙打旺,除了在秋季提高了0~100cm土层土壤水分以外,在春季、夏季和秋季均显著降低了0~500cm土层土壤水分,且间作沙打旺年限越长,降低越显著。间作沙打旺提高了0~100cm土层土壤有机质和全氮含量,间作年限越长效果越显著,但对100cm土层以下的土壤有机质和全氮无显著影响。间作沙打旺对土壤全磷含量无显著影响。间作沙打旺显著降低了土壤速效养分含量,其中速效氮降低深度达500cm土层,速效磷、速效钾达300cm土层,且间作年限越长,降低越显著。间作沙打旺显著削弱了树体的长势,降低了坐果率和杏仁产量。间作沙打旺存在着与仁用杏争水争肥的矛盾,黄土丘陵沟壑区仁用杏园不宜间作沙打旺。
Resumo:
通过分析黄土高原生态环境和生态建设的现状 ,进一步理解在中央决定实施西部大开发战略的新形势下 ,朱钅容基总理有关加强生态环境建设指示的重要意义。并以延安 6 5 0 km2 山川秀美示范区建设为例 ,探讨了生态环境建设的阶段、目标、模式及科技试验示范的主要任务
Resumo:
山坡生产型植物路建设带动沟坡开发是人们争取生存空间,缓和土地压力,建设生态农业的重要途径,也是现阶段农村经济发展的基础。根据现阶段农村建设能力和技术经济条件及实现山川秀美现实需求,提出了适合该地区植物路建设勘测设计方法与综合防护技术体系。
Resumo:
Mapping the spatial distribution of contaminants in soils is the basis of pollution evaluation and risk control. Interpolation methods are extensively applied in the mapping processes to estimate the heavy metal concentrations at unsampled sites. The performances of interpolation methods (inverse distance weighting, local polynomial, ordinary kriging and radial basis functions) were assessed and compared using the root mean square error for cross validation. The results indicated that all interpolation methods provided a high prediction accuracy of the mean concentration of soil heavy metals. However, the classic method based on percentages of polluted samples, gave a pollution area 23.54-41.92% larger than that estimated by interpolation methods. The difference in contaminated area estimation among the four methods reached 6.14%. According to the interpolation results, the spatial uncertainty of polluted areas was mainly located in three types of region: (a) the local maxima concentration region surrounded by low concentration (clean) sites, (b) the local minima concentration region surrounded with highly polluted samples; and (c) the boundaries of the contaminated areas. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Layer-controlled hierarchical flowerlike AgIn(MoO4)(2) microstructures with "clean" surfaces using submicroplates as building blocks without introducing any template have been fabricated through a low-cost hydrothermal method. The near-infrared luminescence of lanthanide ion (Nd, Er, and Yb) doped AgIn(MoO4)(2) microstructures, in the 1300-1600 nm region, was discussed and is of particular interest for telecommunication applications. X-ray diffraction, scanning electron microscopy, transmission electron microscopy, electron diffraction, and photoluminescence spectra were used to characterize these materials.
Resumo:
A clean process has been developed for the synthesis of p-menthane-3,8-diols from cyclization of citronellal in CO2-H2O medium without any additives. With the addition of CO2, the reaction rate could be enhanced about 6 times for the cyclization of citronellal in H2O, because CO2 dissolved into water and formed carbonic acid inducing an increase of the acidity. Although, the reaction conversion in CO2-H2O is slightly lower compared to that obtained with sulfuric acid as catalyst, CO2-H2O could replace the sulfuric acid at a relative higher reaction temperature. The reaction kinetics studies showed that the hydration of isopulegols to p-menthane-3,8-diols is a reversible reaction. The equilibrium constant and the maximum equilibrium yield obtained in CO2-H2O at a range of CO2 pressures are similar to that with sulfuric acid catalyst.
Resumo:
BaF2 nanocubes were prepared from quaternary reverse micelles of cetyl trimethyl ammonium bromide (CTAB), n-butanol, n-octane, and water. Interestingly, there are arching sheet-like dendrites growing between two neighbouring sides of these cubes. X-ray powder diffraction (XRD) analysis showed that the products were BaF2 single phase. Scanning electron microscopy (SEM) or transition electron microscopy (TEM) was used to estimate the size of the final products. The results showed that the shape and size of particles were strongly dependent on the reaction conditions, such as the temperature and reaction time. When the reaction temperature was 25 degreesC, we obtained cuboid-like particles with 'clean' surfaces (no dendrites growing on them), and when the temperature was 35 degreesC, we obtained nanocubes with dendrites growing from them between the neighbouring sides. The influence of reaction time at a temperature of 35 degreesC is also discussed.
Resumo:
A new method for the fabrication of an integrated microelectrode for electrochemical detection (ECD) on an electrophoresis microchip is described. The pattern of the microelectrode was directly made on the surface of a microscope slide through an electroless deposition procedure. The surface of the slide was first selectively coated with a thin layer of sodium silicate through a micromolding in capillary technique provided by a poly(dimethylsiloxane) (PDMS) microchannel; this left a rough patterned area for the anchoring of catalytic particles. A metal layer was deposited on the pattern guided by these catalytic particles and was used as the working electrode. Factors influencing the fabrication procedure were discussed. The whole chip was built by reversibly sealing the slide to another PDMS layer with electrophoresis microchannels at room temperature. This approach eliminates the need of clean room facilities and expensive apparatus such as for vacuum deposition or sputtering and makes it possible to produce patterned electrodes suitable for ECD on microchip under ordinary chemistry laboratory conditions. Also once the micropattern is ready, it allows the researchers to rebuild the electrode in a short period of time when an electrode failure occurs. Copper and gold microelectrodes were fabricated by this technique. Glucose, dopamine, and catechol as model analytes were tested.