1000 resultados para CT colonography (virtual colonoscopy)
Resumo:
The following paper introduces the work conducted to create a relative virtual mouse based on the interpretation of head movements and face gesture through a low cost camera and the optical flow of the images. This virtual device is designed specifically as an alternative non-contact pointer for people with mobility impairments in the upper extremities and reduced head control. The proposed virtual device was compared with a conventional mouse, a touchpad and a digital joystick. Validation results show performances close to a digital joystick but far away from a conventional mouse.
Resumo:
Ranskalaisen Pierre Louis Moreau de Maupertuis'n johtama retkikunta selvitti 1736 maapallon muotoa Lapissa kolmiomittauksen avulla. Retkikunta majaili Korteniemen talossa, vaaran laella observatorio. - Digi toitu valokuvasta, joka julkaistu 1993 kirjassa Historiallisia kuvia / R. Knapas & P. Koistinen
Resumo:
Objetivos. Valorar la utilidad de un fórum virtual sobre la discusión de un caso clínico por grupos para la presentación de un trabajo individual. Material y métodos. En uno de los seminarios de la asignatura Enfermedades del Aparato Respiratorio y ORL del grado de Medicina, se creó un fórum virtual para discutir un caso clínico por grupos, antes de presentar un trabajo individual. Se realizaron cuatro grupos (A, B, C y D) y se abrieron cuatro temas. Cada grupo sólo podía participar en uno, pero tenían que observar la evolución de los otros foros. El trabajo individual consistía en contestar a varias preguntas planteadas por el profesor relacionadas con el desarrollo del caso clínico virtual. Para analizar los resultados de la experiencia se valoró: el número de participaciones en el foro, el número de participaciones por grupo, la nota del trabajo individual y la opinión del profesor Resultados. Se realizaron 129 participaciones al foro. El grupo A fue el que más participó (27%). El 78% de los alumnos obtuvo una nota comprendida entre el 7 y el 9. Del análisis cualitativo del trabajo individual se observó que los alumnos contestaban correctamente las preguntas, pero no se basaban en lo que sus compañeros habían desarrollado en el foro. Conclusiones. Los foros virtuales basados en la discusión de casos clínicos pueden facilitar el aprendizaje colaborativo en alumnos del grado de Medicina.
Resumo:
Contexte Lié au vieillissement et à la sédentarisation de la population, ainsi qu'à la chronicisation du cancer, l'emploi de cathéters veineux centraux permanents (CVCP) n'a cessé d'augmenter. La complication majeure de ces dispositifs, induisant de forts taux de morbi-mortalité, est l'infection. Actuellement, le diagnostic de ces infections reste surtout basé sur la clinique et les hémocultures. Lorsque le doute persiste, une ablation chirurgicale suivie de la mise en culture des prélèvements chirurgicaux et du cathéter permettent de poser le diagnostic. En clinique, après ces examens, nous constatons que seule la moitié des cathéters retirés étaient réellement infectés. Alors que la tomographie par émission de positons fusionnée à la tomographie (PET/CT) a montré de bons résultats dans la détection des infections chroniques, la valeur diagnostique du PET/CT au fluorodeoxyglucose marqué au 18F (18F-FDG) pour les infections de CVCP n'a encore jamais été déterminée dans une étude prospective. Objectifs Au travers de cette étude prospective, ouverte et monocentrique, nous chercherons à connaître la valeur diagnostique du PET/CT au 18F-FDG dans la détection d'infections de CVCP et ainsi d'en déterminer son utilité. Nous essaierons aussi de déterminer la différence de valeur diagnostique du PET/CT au 18F-FDG par rapport aux méthodes conventionnelles (paramètres cliniques et culture du liquide d'aspiration), afin de se déterminer sur l'éventuelle utilité diagnostique de celui-ci. Méthodes Cadre : Etude prospective d'au moins 20 patients, avec 2 groupes contrôles d'au moins 10 patients ayant chacun respectivement une faible et une forte probabilité d'infection, soit au moins 40 patients au total. Population : patients adultes avec CVCP devant être retiré. Cette étude prévoit un examen PET/CT au 18F-FDG effectué auprès de patients nécessitant une ablation de CVCP sur suspicion d'infection, sans confirmation possible par les moyens diagnostiques non chirurgicaux. Deux acquisitions seront réalisées 45 et 70 minutes après l'injection de 5,5MBq/Kg de 18F-FDG. Le groupe contrôle à faible probabilité d'infection, sera formé de patients bénéficiant de l'ablation définitive d'un CVCP pour fin de traitement durant le laps de temps de l'étude, et ayant bénéficié au préalable d'un examen PET/CT pour raison X. Après avoir retiré chirurgicalement le CVCP, nous utiliserons la culture microbiologique des deux extrémités du CVCP comme étalon d'or (gold standard) de l'infection. Le groupe contrôle à forte probabilité d'infection sera formé de patients nécessitant une ablation de CVCP sur infection de CVCP confirmée par les moyens diagnostiques non chirurgicaux (culture positive du liquide de l'aspiration). Lors de l'examen PET/CT, ces patients auront aussi deux acquisitions réalisées 45 et 70 minutes après l'injection de 5,5MBq/Kg de 18F-FDG. Les résultats de ces examens seront évalués par deux spécialistes en médecine nucléaire qui détermineront le niveau de suspicion de l'infection sur une échelle de Likert allant de I à V, sur la base du nombre de foyers, de la localisation du foyer, de l'intensité de la captation de 18F-FDG au voisinage du cathéter et du rapport tissu/arrière-plan. Par la suite, nous retirerons chirurgicalement le CVCP. Nous utiliserons la culture microbiologique du pus (si présent), des deux extrémités du CVCP ainsi que l'histologie des tissus formant un tunnel autour du cathéter comme étalon d'or de l'infection. Les résultats seront analysés à l'aide de courbes ROC (Receiver Operating Characteristic) afin de déterminer la valeur diagnostique du PET/CT dans l'infection de CVCP. Les résultats des examens des patients avec suspicion clinique d'infection seront ensuite analysés séparément, afin de déterminer la différence de valeur diagnostique du PET/CT au 18F-FDG par rapport aux méthodes conventionnelles. Résultats escomptés Ce projet veut chercher à savoir si le PET/CT au 18F-FDG peut être un moyen diagnostique valide dans les infections de CVCP, s'avérer utile lorsque les autres moyens diagnostiques sont non conclusifs. Plus-value escomptée Actuellement, lors d'incertitude sur le diagnostic d'infection de CVCP, une opération chirurgicale est effectuée à titre préventif afin d'enlever le cathéter en cause, cependant seulement la moitié de ces cathéters sont réellement infectés en pratique. Le PET/CT au 18F-FDG, grâce à sa sensibilité élevée et probablement une bonne valeur prédictive négative, pourrait éviter à une partie des patients un retrait inutile du cathéter, diminuant ainsi les risques chirurgicaux et les coûts liés à de telles opérations, tout en préservant le capital d'accès vasculaire futur.
Resumo:
PURPOSE: The aim of this study was to compare multidetector CT (MDCT), MRI, and FDG PET/CT imaging for the detection of peritoneal carcinomatosis (PC) in ovarian cancer. PATIENTS AND METHODS: Fifteen women with ovarian cancer and suspected PC underwent MDCT, MRI, and FDG PET/CT, shortly before surgery. Nine abdominopelvic regions were defined according to the peritoneal cancer index. We applied lesion size scores on MDCT and MR and measured FDG PET/CT standard uptake. We blindly read MDCT, MR, and PET/CT before joint review and comparison with histopathology. Receiver operating characteristics analysis was performed. RESULTS: Ten women had PC (67%). Altogether, 135 abdominopelvic sites were compared. Multidetector CT, MRI, and FDG PET/CT had a sensitivity of 96%, 98%, and 95%, and specificity was 92%, 84%, and 96%, respectively. Corresponding receiver operating characteristics area was 0.94, 0.90, and 0.96, respectively, without any significant differences between them (P = 0.12). FDG PET/CT detected supradiaphragmatic disease in 3 women (20%) not seen by MDCT or MRI. CONCLUSIONS: Although MRI had the highest sensitivity and FDG PET/CT had the highest specificity, no significant differences were found between the 3 techniques. Thus, MDCT, as the fastest, most economical, and most widely available modality, is the examination of choice, if a stand-alone technique is required. If inconclusive, PET/CT or MRI may offer additional insights. Whole-body FDG PET/CT may be more accurate for supradiaphragmatic metastatic extension.
Resumo:
BACKGROUND AND PURPOSE: The posterior circulation Acute Stroke Prognosis Early CT Score (pc-APECTS) applied to CT angiography source images (CTA-SI) predicts the functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). We assessed the diagnostic and prognostic impact of pc-ASPECTS applied to perfusion CT (CTP) in the BASICS registry population. METHODS: We applied pc-ASPECTS to CTA-SI and cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) parameter maps of BASICS patients with CTA and CTP studies performed. Hypoattenuation on CTA-SI, relative reduction in CBV or CBF, or relative increase in MTT were rated as abnormal. RESULTS: CTA and CTP were available in 27/592 BASICS patients (4.6%). The proportion of patients with any perfusion abnormality was highest for MTT (93%; 95% confidence interval [CI], 76%-99%), compared with 78% (58%-91%) for CTA-SI and CBF, and 46% (27%-67%) for CBV (P < .001). All 3 patients with a CBV pc-ASPECTS < 8 compared to 6/23 patients with a CBV pc-ASPECTS ≥ 8 had died at 1 month (RR 3.8; 95% CI, 1.9-7.6). CONCLUSION: CTP was performed in a minority of the BASICS registry population. Perfusion disturbances in the posterior circulation were most pronounced on MTT parameter maps. CBV pc-ASPECTS < 8 may indicate patients with high case fatality.
Resumo:
Pregunta de revisión: ¿El tratamiento de doble tarea con la incorporación del sistema de realidad virtual BioTrack favorece el equilibrio en los pacientes que han sufrido un traumatismo craneoencefálico? Objetivo: Determinar si el trabajo de doble tarea cognitivo-motor con la incorporación de realidad virtual favorece el equilibrio de los pacientes con traumatismo craneoencefálico. Metodología: se realizará un diseño de tipo experimental, aleatorio controlado y prospectivo. Se planteará un proyecto de 36 sesiones dividido en seis meses basado en trabajo de doble tarea cognitivo-motor con realidad virtual. Consta de un tratamiento combinado de ejercicios para el equilibrio con el soporte de realidad virtual BioTrack. Al mismo tiempo se trabajará la memoria y la atención para el trabajo cognitivo. Se compara con el grupo control que solo realiza ejercicios con BioTrack. La medida principal es el equilibrio medido con la berg balance scale y la influencia del trabajo cognitivo.
Resumo:
Presentació del projecte de disseny i desenvolupament del nou web de la Biblioteca Virtual, a la Jornada Tècnica de UOC.
Resumo:
We present a case study of the redesign of the organizational presentation and content of the Virtual Library website at the Universitat Oberta de Catalunya (Open University of Catalonia, UOC), based on a user-centered design strategy. The aim of the redesign was to provide users with more intuitive, usable and understandable content (textual content, resources and services) by implementing criteria of customization, transparency and proximity. The study also presents a selection of best practices for applying these criteria to the design of other library websites.
Resumo:
This abstract presents how we redesigned, with user-centred design methods, the way we organize and present the content on the UOC Virtual Library website. The content is now offered in a way that is more intuitive, usable and easy to understand, based on criteria of customization, transparency and proximity.The techniques used to achieve these objectives included benchmarking, interviews and focus groups during the user requirement capture phase and user tests to assess the process and results.
Resumo:
A sign of presence in virtual environments is that people respond to situations and events as if they were real, where response may be considered at many different levels, ranging from unconscious physiological responses through to overt behavior,emotions, and thoughts. In this paper we consider two responses that gave different indications of the onset of presence in a gradually forming environment. Two aspects of the response of people to an immersive virtual environment were recorded: their eye scanpath, and their skin conductance response (SCR). The scenario was formed over a period of 2 min, by introducing an increasing number of its polygons in random order in a head-tracked head-mounted display. For one group of experimental participants (n 8) the environment formed into one in which they found themselves standing on top of a 3 m high column. For a second group of participants (n 6) the environment was otherwise the same except that the column was only 1 cm high, so that they would be standing at normal ground level. For a third group of participants (n 14) the polygons never formed into a meaningful environment. The participants who stood on top of the tall column exhibited a significant decrease in entropy of the eye scanpath and an increase in the number of SCR by 99 s into the scenario, at a time when only 65% of the polygons had been displayed. The ground level participants exhibited a similar decrease in scanpath entropy, but not the increase in SCR. The random scenario grouping did not exhibit this decrease in eye scanpath entropy. A drop in scanpath entropy indicates that the environment had cohered into a meaningful perception. An increase in the rate of SCR indicates the perception of an aversive stimulus. These results suggest that on these two dimensions (scanpath entropy and rate of SCR) participants were responding realistically to the scenario shown in the virtual environment. In addition, the response occurred well before the entire scenario had been displayed, suggesting that once a set of minimal cues exists within a scenario,it is enough to form a meaningful perception. Moreover, at the level of the sympathetic nervous system, the participants who were standing on top of the column exhibited arousal as if their experience might be real. This is an important practical aspect of the concept of presence.
Resumo:
Informe de l'anàlisi realitzat sobre el nou web de la Biblioteca Virtual de la UOC, mitjançant el mètode de test amb usuaris, per tal d'avaluar el grau d'usabilitat de la nova eina. L'anàlisi s'emmarca en el procés de disseny centrat en l'usuari que s'ha utilitzat per al seu disseny.
Resumo:
Informe de l'anàlisi realitzat sobre el nou web de la Biblioteca Virtual de la UOC, per tal d'avaluar el grau d'usabilitat de la nova eina. És el segon test amb usuaris que es realitza del nou web i s'han analitzat els següents aspectes: l'accés a la col·lecció digital, les cinc funcionalitats més utilitzades del web i les cinc funcionalitats menys visibles del web.