987 resultados para CT angiography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This phase II trial aimed to evaluate feasibility and efficacy of a first-line combination of targeted therapies for advanced non-squamous NSCLC: bevacizumab (B) and erlotinib (E), followed by platinum-based CT at disease progression (PD).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Development of novel implants in orthopaedic trauma surgery is based on limited datasets of cadaver trials or artificial bone models. A method has been developed whereby implants can be constructed in an evidence based method founded on a large anatomic database consisting of more than 2.000 datasets of bones extracted from CT scans. The aim of this study was the development and clinical application of an anatomically pre-contoured plate for the treatment of distal fibular fractures based on the anatomical database. 48 Caucasian and Asian bone models (left and right) from the database were used for the preliminary optimization process and validation of the fibula plate. The implant was constructed to fit bilaterally in a lateral position of the fibula. Then a biomechanical comparison of the designed implant to the current gold standard in the treatment of distal fibular fractures (locking 1/3 tubular plate) was conducted. Finally, a clinical surveillance study to evaluate the grade of implant fit achieved was performed. The results showed that with a virtual anatomic database it was possible to design a fibula plate with an optimized fit for a large proportion of the population. Biomechanical testing showed the novel fibula plate to be superior to 1/3 tubular plates in 4-point bending tests. The clinical application showed a very high degree of primary implant fit. Only in a small minority of cases further intra-operative implant bending was necessary. Therefore, the goal to develop an implant for the treatment of distal fibular fractures based on the evidence of a large anatomical database could be attained. Biomechanical testing showed good results regarding the stability and the clinical application confirmed the high grade of anatomical fit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the impact of (18)F-DOPA brain PET/CT on the clinical management of patients with known or suspected brain tumors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many children with sarcomas undergo whole body 2-deoxy-2-((18)F)fluoro-D-glucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) and technetium methylene diphosphonate ((99)Tc-MDP) studies. It is unknown whether the combination of both tests results in more accurate detection of bone lesions than (18)F-FDG- PET/CT alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the accuracy of hypodense regions in non-contrast-enhanced cardiac computed tomography (unenhanced CT) to identify nonviable myocardial scar tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CLINICAL/METHODICAL ISSUE: Skeletal infections are often a diagnostic and clinical challenge. STANDARD RADIOLOGICAL METHODS: Nuclear imaging modalities used in the diagnostic workup of acute and chronic skeletal infections include three-phase bone scintigraphy and scintigraphy with labelled leucocytes. METHODICAL INNOVATIONS: The introduction of hybrid technologies, such as single photon emission computed tomography/computed tomography (SPECT/CT) has dramatically changed nuclear medical imaging of infections. PERFORMANCE: In general SPECT/CT leads to a considerably more accurate diagnosis than planar or SPECT imaging. ACHIEVEMENTS: Given the integrated acquisition of metabolic, functional and morphological information, SPECT/CT has increased in particular the specificity of three-phase skeletal scanning and scintigraphy with labeled leucocytes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Malignant melanoma has become an increasing interdisciplinary public health challenge worldwide. Sentinel lymph node excision (SLNE) is considered the most sensitive and specific staging test for the detection of micrometastatic melanoma in regional lymph nodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BackgroundDespite the increasingly higher spatial and contrast resolution of CT, nodular lesions are prone to be missed on chest CT. Tinted lenses increase visual acuity and contrast sensitivity by filtering short wavelength light of solar and artificial origin.PurposeTo test the impact of Gunnar eyewear, image quality (standard versus low dose CT) and nodule location on detectability of lung nodules in CT and to compare their individual influence.Material and MethodsA pre-existing database of CT images of patients with lung nodules >5 mm, scanned with standard does image quality (150 ref mAs/120 kVp) and lower dose/quality (40 ref mAs/120 kVp), was used. Five radiologists read 60 chest CTs twice: once with Gunnar glasses and once without glasses with a 1 month break between. At both read-outs the cases were shown at lower dose or standard dose level to quantify the influence of both variables (eyewear vs. image quality) on nodule sensitivity.ResultsThe sensitivity of CT for lung nodules increased significantly using Gunnar eyewear for two readers and insignificantly for two other readers. Over all, the mean sensitivity of all radiologist raised significantly from 50% to 53%, using the glasses (P value = 0.034). In contrast, sensitivity for lung nodules was not significantly affected by lowering the image quality from 150 to 40 ref mAs. The average sensitivity was 52% at low dose level, that was even 0.7% higher than at standard dose level (P value = 0.40). The strongest impact on sensitivity had the factors readers and nodule location (lung segments).ConclusionSensitivity for lung nodules was significantly enhanced by Gunnar eyewear (+3%), while lower image quality (40 ref mAs) had no impact on nodule sensitivity. Not using the glasses had a bigger impact on sensitivity than lowering the image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the ability of low-dose CT to detect and characterize the most common CT patterns of pulmonary disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Time-of-flight (ToF) and phase contrast (PC) magnetic resonance angiographies (MRAs) are noninvasive applications to depict the cerebral arteries. Both approaches can image the cerebral vasculature without the administration of intravenous contrast. Therefore, it is used in routine clinical evaluation of cerebrovascular diseases, e.g., aneurysm and arteriovenous malformations. However, subtle microvascular disease usually cannot be resolved with standard, clinical-field-strength MRA. The purpose of this study was to compare the ability of ToF and PC MRA to visualize the cerebral arteries at increasing field strengths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare diagnostic accuracy of multi-station, high-spatial resolution contrast-enhanced MR angiography (CE-MRA) of the lower extremities with digital subtraction angiography (DSA) as the reference standard in patients with symptomatic peripheral arterial occlusive disease. MATERIALS AND METHODS: Of 485 consecutive patients undergoing a run-off CE-MRA, 152 patients (86 male, 66 female; mean age, 71.6 years) with suspected peripheral arterial occlusive disease were included into our Institutional Review Board approved study. All patients underwent MRA and DSA of the lower extremities within 30 days. MRA was performed at 1.5 Tesla with a single bolus of 0.1 mmol/kg body weight of gadobutrol administered at a rate of 2.0 mL/s at three stations. Two readers evaluated the MRA images independently for stenosis grade and image quality. Sensitivity and specificity were derived. RESULTS: Sensitivity and specificity ranged from 73% to 93% and 64% to 89% and were highest in the thigh area. Both readers showed comparable results. Evaluation of good and better quality MRAs resulted in a considerable improvement in diagnostic accuracy. CONCLUSION: Contrast-enhanced MRA demonstrates good sensitivity and specificity in the investigation of the vasculature of the lower extremities. While a minor investigator experience dependence remains, it is standardizable and shows good inter-observer agreement. Our results confirm that the administration of Gadobutrol at a standard dose of 0.1 mmol/kg for contrast-enhanced runoff MRA is able to detect hemodynamically relevant stenoses. Use of contrast-enhanced MRA as an alternative to intra-arterial DSA in the evaluation and therapeutic planning of patients with suspected peripheral arterial occlusive disease is well justified. J. Magn. Reson. Imaging 2013;37:1427-1435. © 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Aim of this study was to compare the utility of susceptibility weighted imaging (SWI) with the established diagnostic techniques CT and fluid attenuated inversion recovery (FLAIR) in their detecting capacity of subarachnoid hemorrhage (SAH), and further to compare the combined SWI/FLAIR MRI data with CT to evaluate whether MRI is more accurate than CT. METHODS: Twenty-five patients with acute SAH underwent CT and MRI within 6 days after symptom onset. Underlying pathology for SAH was head trauma (n=9), ruptured aneurysm (n=6), ruptured arteriovenous malformation (n=2), and spontaneous bleeding (n=8). SWI, FLAIR, and CT data were analyzed. The anatomical distribution of SAH was subdivided into 8 subarachnoid regions with three peripheral cisterns (frontal-parietal, temporal-occipital, sylvian), two central cisterns and spaces (interhemispheric, intraventricular), and the perimesencephalic, posterior fossa, superior cerebellar cisterns. RESULTS: SAH was detected in a total of 146 subarachnoid regions. CT identified 110 (75.3%), FLAIR 127 (87%), and SWI 129 (88.4%) involved regions. Combined FLAIR and SWI identified all 146 detectable regions (100%). FLAIR was sensitive for frontal-parietal, temporal-occipital and Sylvian cistern SAH, while SWI was particularly sensitive for interhemispheric and intraventricular hemorrhage. CONCLUSIONS: By combining SWI and FLAIR, MRI yields a distinctly higher detection rate for SAH than CT alone, particularly due to their complementary detection characteristics in different anatomical regions. Detection strength of SWI is high in central areas, whereas FLAIR shows a better detection rate in peripheral areas.