824 resultados para Building materials - Energy consumption
Resumo:
Finite Difference Time Domain (FDTD) Method and software are applied to obtain diffraction waves from modulated Gaussian plane wave illumination for right angle wedges and Fast Fourier Transform (FFT) is used to get diffraction coefficients in a wideband in the illuminated lit region. Theta and Phi polarization in 3-dimensional, TM and TE polarization in 2-dimensional cases are considered respectively for soft and hard diffraction coefficients. Results using FDTD method of perfect electric conductor (PEC) wedge are compared with asymptotic expressions from Uniform Theory of Diffraction (UTD). Extend the PEC wedges to some homogenous conducting and dielectric building materials for diffraction coefficients that are not available analytically in practical conditions. ^
Resumo:
Electrical energy is an essential resource for the modern world. Unfortunately, its price has almost doubled in the last decade. Furthermore, energy production is also currently one of the primary sources of pollution. These concerns are becoming more important in data-centers. As more computational power is required to serve hundreds of millions of users, bigger data-centers are becoming necessary. This results in higher electrical energy consumption. Of all the energy used in data-centers, including power distribution units, lights, and cooling, computer hardware consumes as much as 80%. Consequently, there is opportunity to make data-centers more energy efficient by designing systems with lower energy footprint. Consuming less energy is critical not only in data-centers. It is also important in mobile devices where battery-based energy is a scarce resource. Reducing the energy consumption of these devices will allow them to last longer and re-charge less frequently. Saving energy in computer systems is a challenging problem. Improving a system's energy efficiency usually comes at the cost of compromises in other areas such as performance or reliability. In the case of secondary storage, for example, spinning-down the disks to save energy can incur high latencies if they are accessed while in this state. The challenge is to be able to increase the energy efficiency while keeping the system as reliable and responsive as before. This thesis tackles the problem of improving energy efficiency in existing systems while reducing the impact on performance. First, we propose a new technique to achieve fine grained energy proportionality in multi-disk systems; Second, we design and implement an energy-efficient cache system using flash memory that increases disk idleness to save energy; Finally, we identify and explore solutions for the page fetch-before-update problem in caching systems that can: (a) control better I/O traffic to secondary storage and (b) provide critical performance improvement for energy efficient systems.
Resumo:
Recently, energy efficiency or green IT has become a hot issue for many IT infrastructures as they attempt to utilize energy-efficient strategies in their enterprise IT systems in order to minimize operational costs. Networking devices are shared resources connecting important IT infrastructures, especially in a data center network they are always operated 24/7 which consume a huge amount of energy, and it has been obviously shown that this energy consumption is largely independent of the traffic through the devices. As a result, power consumption in networking devices is becoming more and more a critical problem, which is of interest for both research community and general public. Multicast benefits group communications in saving link bandwidth and improving application throughput, both of which are important for green data center. In this paper, we study the deployment strategy of multicast switches in hybrid mode in energy-aware data center network: a case of famous fat-tree topology. The objective is to find the best location to deploy multicast switch not only to achieve optimal bandwidth utilization but also to minimize power consumption. We show that it is possible to easily achieve nearly 50% of energy consumption after applying our proposed algorithm.
Resumo:
In recent years, as part of the expansion process of its activities, the Instituto Federal de Educação, Ciência e Tecnologia do Rio Grande do Norte – IFRN (Federal Institute for Education, Science and Technology of the State of Rio Grande do Norte – IFRN) detected the need to hire more employees for the institution. This expansion process, a policy of the Federal Government, together with the increase of human resources, required the construction of an adequate facility in the municipality of São Gonçalo do Amarante-RN, for training and qualification and as a means of better enabling its personnel. Along with this policy, the Federal Government is also deeply concerned that its buildings be environmentally friendly. This study deals with this subject matter, as it develops an architectural design of a public building with an emphasis upon the reduction of energy consumption, through the study of energy performance factors such as defined by Carneiro (1988) and adapted by the author of the present study. It is known that residential, commercial and public buildings represent about 45 % of energy consumption in Brazil. That is why it is necessary to consider the reduction of such consumption in buildings, as well as the role that professionals, especially architects, play in this issue. The most effective participation in this regard in the field of architecture occurs in the design phase. However, the architectural solution proposed here goes beyond the energy performance factors, since it also involves other aspects, such as the definition of the concept, the parti and the spatial solution itself. In this sense, the architectural project of the Centro de Treinamento dos Servidores do IFRN - CTSIFRN (Training Center for IFRN Personnel – CTSFIRN) is particularly fitting as a subject for research at the Professional Master Program at PPGAU/UFRN, which is devoted to research on architecture, design and the environment.
Resumo:
The textile effluents are a complex mixture of many pollutants that contain high organic loads, severe color and toxic compounds. The high concentration of the textile effluent may cause increased chemical demand (COD) and biochemical (BOD) of oxygen, elevated temperature, acidity or alkalinity, causing damage and environmental problems. In addition to representing a serious threat to human health such effluent is also quite toxic to most aquatic organisms. And for this reason, one must meet the concentration limits for emission sources and sewage system. This study aimed to investigate the performance of electrochemical treatment of a textile effluent for the removal of color, turbidity, dissolved oxygen (DO) and dissolved organic matter by investigating the influence of experimental parameters such as the electrocatalyst materials (Ti/Pt and Ti/Pt-SnSb) and current density in order to compare their efficiency, energy consumption and cost. The dye Novacron Blue CD (NB) was employed in synthetic solution, while the dyes Remazol Yellow 3RS (RY 3RS) Remazol Red RR Gran (RR-RR Gran) and Navy Blue CL-R (NB CL-R) were used to generate simulated textile effluent laboratory. The results showed that the application of electrochemical oxidation process favors the elimination of color effectively independent the electrocatalytic material and current used, as well as treated effluent. However, the influence of electrocatalytic material was crucial to reduction of the organic matter in all cases.
Resumo:
Through this paper we will look at links between architecture education, research and practice, using a current project as a vehicle to cover aspects of building, pilot and live project. The first aspect, the building project consists of the refurbishment and extension of a Parnell Cottage for a private client and is located near Cloyne, in East Cork, Ireland. The pilot project falls within the NEES Project, investigating the use of materials and services based on natural or recycled materials to improve the energy performance of new and existing buildings. The live project aims to hold a series of on site workshops and seminars for students of Architecture, Architects and interested parties, demonstrating the integration of the NEES best practice materials and techniques within the built project. The workshops, seminars and key project documents will be digitally recorded for dissemination through a web based publication. The small scale of the building project allowed for flexibility in the early conceptual design stages and the integration of the research and educational aspects.
Resumo:
Wireless sensor networks (WSNs) have shown wide applicability to many fields including monitoring of environmental, civil, and industrial settings. WSNs however are resource constrained by many competing factors that span their hardware, software, and networking. One of the central resource constrains is the charge consumption of WSN nodes. With finite energy supplies, low charge consumption is needed to ensure long lifetimes and success of WSNs. This thesis details the design of a power system to support long-term operation of WSNs. The power system’s development occurs in parallel with a custom WSN from the Queen’s MEMS Lab (QML-WSN), with the goal of supporting a 1+ year lifetime without sacrificing functionality. The final power system design utilizes a TPS62740 DC-DC converter with AA alkaline batteries to efficiently supply the nodes while providing battery monitoring functionality and an expansion slot for future development. Testing tools for measuring current draw and charge consumption were created along with analysis and processing software. Through their use charge consumption of the power system was drastically lowered and issues in QML-WSN were identified and resolved including the proper shutdown of accelerometers, and incorrect microcontroller unit (MCU) power pin connection. Controlled current profiling revealed unexpected behaviour of nodes and detailed current-voltage relationships. These relationships were utilized with a lifetime projection model to estimate a lifetime between 521-551 days, depending on the mode of operation. The power system and QML-WSN were tested over a long term trial lasting 272+ days in an industrial testbed to monitor an air compressor pump. Environmental factors were found to influence the behaviour of nodes leading to increased charge consumption, while a node in an office setting was still operating at the conclusion of the trail. This agrees with the lifetime projection and gives a strong indication that a 1+ year lifetime is achievable. Additionally, a light-weight charge consumption model was developed which allows charge consumption information of nodes in a distributed WSN to be monitored. This model was tested in a laboratory setting demonstrating +95% accuracy for high packet reception rate WSNs across varying data rates, battery supply capacities, and runtimes up to full battery depletion.
Resumo:
Natural pozzolans are raw materials from geological deposits with a range of chemical compositions that when combined with suitable alkali activators can be converted to geopolymer cement for concrete production. In this paper the concept of adding mineral additives to enhance the properties of geopolymer cement is introduced. Taftan andesite, a natural Iranian pozzolan, was used to study the effect of adding mineral additives such as kaolinite, lime and other calcined pozzolans on the compressive strength of geopolymer cement under both normal and autoclave curing. Scanning electron microscopy (SEM)/energy dispersive X-ray (EDX) was used to determine the composition of the gel phase in both alkali-activated Taftan pozzolan with and without mineral additions. The work has shown that deficiencies in SiO2, Al2O3 and CaO content in the raw natural pozzolan can be compensated for by adding mineral additives for enhanced properties.
Resumo:
The article is focused on analysis of global efficiency of new mold for rotational molding of plastic parts, being directly heated by thermal fluid. The overall efficiency is based on several items such as reduction of cycle time, better uniformity of heating-cooling and low energy consumption. The new tool takes advantage of additive fabrication and electroforming for making the optimal manifold and cavity shell of the mold. Experimental test of a prototype mold was carried out on an experimental rotational molding machine, developed for this purpose, measuring wall temperature, and internal air temperature, with and without plastic material inside. Results were compared with conventional mold heated into an oven and to theoretical simulations done by Computational Fluid Dynamic software (CFD). The analysis represents considerable improvement of cycle time related to conventional methods (heated by oven) and better thermal uniformity to conventional procedures by direct heating of oil with external channels. In addition to thermal analysis an energetic efficiency study was done. POLYM. ENG. SCI., 52:1998-2005, 2012. © 2012 Society of Plastics Engineers Copyright © 2012 Society of Plastics Engineers.
Resumo:
PEDRINI, Aldomar; SZOKOLAY, Steven. Recomendações para o desenvolvimento de uma ferramenta de suporte às primeiras decisões projetuais visando ao desempenho energético de edificações de escritório em clima quente. Ambiente Construído, Porto Alegre, v. 5, n. 1, p.39-54, jan./mar. 2005. Trimestral. Disponível em:
Resumo:
Hotel chains have access to a treasure trove of “big data” on individual hotels’ monthly electricity and water consumption. Benchmarked comparisons of hotels within a specific chain create the opportunity to cost-effectively improve the environmental performance of specific hotels. This paper describes a simple approach for using such data to achieve the joint goals of reducing operating expenditure and achieving broad sustainability goals. In recent years, energy economists have used such “big data” to generate insights about the energy consumption of the residential, commercial, and industrial sectors. Lessons from these studies are directly applicable for the hotel sector. A hotel’s administrative data provide a “laboratory” for conducting random control trials to establish what works in enhancing hotel energy efficiency.
Resumo:
Several studies have been undertaken or attempted by industry and academe to address the need for lodging industry carbon benchmarking. However, these studies have focused on normalizing resource use with the goal of rating or comparing all properties based on multivariate regression according to an industry-wide set of variables, with the result that data sets for analysis were limited. This approach is backward, because practical hotel industry benchmarking must first be undertaken within a specific location and segment.1 Therefore, the CHSB study’s goal is to build a representative database providing raw benchmarks as a base for industry comparisons.2 These results are presented in the CHSB2016 Index, through which a user can obtain the range of benchmarks for energy consumption, water consumption, and greenhouse gas emissions for hotels within specific segments and geographic locations.
Resumo:
The evolution of wireless communication systems leads to Dynamic Spectrum Allocation for Cognitive Radio, which requires reliable spectrum sensing techniques. Among the spectrum sensing methods proposed in the literature, those that exploit cyclostationary characteristics of radio signals are particularly suitable for communication environments with low signal-to-noise ratios, or with non-stationary noise. However, such methods have high computational complexity that directly raises the power consumption of devices which often have very stringent low-power requirements. We propose a strategy for cyclostationary spectrum sensing with reduced energy consumption. This strategy is based on the principle that p processors working at slower frequencies consume less power than a single processor for the same execution time. We devise a strict relation between the energy savings and common parallel system metrics. The results of simulations show that our strategy promises very significant savings in actual devices.
Resumo:
Le bois subit une demande croissante comme matériau de construction dans les bâtiments de grandes dimensions. Ses qualités de matériau renouvelable et esthétique le rendent attrayant pour les architectes. Lorsque comparé à des produits fonctionnellement équivalents, il apparait que le bois permet de réduire la consommation d’énergie non-renouvelable. Sa transformation nécessite une quantité d’énergie inférieure que l’acier et le béton. Par ailleurs, par son origine biologique, une structure en bois permet de stocker du carbone biogénique pour la durée de vie du bâtiment. Maintenant permis jusqu’à six étages de hauteur au Canada, les bâtiments de grande taille en bois relèvent des défis de conception. Lors du dimensionnement des structures, les zones des connecteurs sont souvent les points critiques. Effectivement, les contraintes y sont maximales. Les structures peuvent alors apparaitre massives et diminuer l’innovation architecturale. De nouvelles stratégies doivent donc être développées afin d’améliorer la résistance mécanique dans les zones de connecteurs. Différents travaux ont récemment porté sur la création ou l’amélioration de types d’assemblage. Dans cette étude, l’accent est mis sur le renforcement du bois utilisé dans la région de connexion. L’imprégnation a été choisie comme solution de renfort puisque la littérature démontre qu’il est possible d’augmenter la dureté du bois avec cette technique. L’utilisation de cette stratégie de renfort sur l’épinette noire (Picea Mariana (Mill.) BSP) pour une application structurale est l’élément de nouveauté dans cette recherche. À défaut d’effectuer une imprégnation jusqu’au coeur des pièces, l’essence peu perméable de bois employée favorise la création d’une mince couche en surface traitée sans avoir à utiliser une quantité importante de produits chimiques. L’agent d’imprégnation est composé de 1,6 hexanediol diacrylate, de triméthylopropane tricacrylate et d’un oligomère de polyester acrylate. Une deuxième formulation contenant des nanoparticules de SiO2 a permis de vérifier l’effet des nanoparticules sur l’augmentation de la résistance mécanique du bois. Ainsi, dans ce projet, un procédé d’imprégnation vide-pression a servi à modifier un nouveau matériau à base de bois permettant des assemblages plus résistants mécaniquement. Le test de portance locale à l’enfoncement parallèle au fil d’un connecteur de type tige a été réalisé afin de déterminer l’apport du traitement sur le bois utilisé comme élément de connexion. L’effet d’échelle a été observé par la réalisation du test avec trois diamètres de boulons différents (9,525 mm, 12,700 mm et 15,875 mm). En outre, le test a été effectué selon un chargement perpendiculaire au fil pour le boulon de moyen diamètre (12,700 mm). La corrélation d’images numériques a été utilisée comme outil d’analyse de la répartition des contraintes dans le bois. Les résultats ont démontré une portance du bois plus élevée suite au traitement. Par ailleurs, l’efficacité est croissante lorsque le diamètre du boulon diminue. C’est un produit avec une valeur caractéristique de la portance locale parallèle au fil de 79% supérieure qui a été créé dans le cas du test avec le boulon de 9,525 mm. La raideur du bois a subi une augmentation avoisinant les 30%. Suite au traitement, la présence d’une rupture par fissuration est moins fréquente. Les contraintes se distribuent plus largement autour de la région de connexion. Le traitement n’a pas produit d’effet significatif sur la résistance mécanique de l’assemblage dans le cas d’un enfoncement du boulon perpendiculairement au fil du bois. De même, l’effet des nanoparticules en solution n’est pas ressorti significatif. Malgré une pénétration très faible du liquide à l’intérieur du bois, la couche densifiée en surface créée suite au traitement est suffisante pour produire un nouveau matériau plus résistant dans les zones de connexion. Le renfort du bois dans la région des connecteurs doit influencer le dimensionnement des structures de grande taille. Avec des éléments de connexion renforcés, il sera possible d’allonger les portées des poutres, multipliant ainsi les possibilités architecturales. Le renfort pourra aussi permettre de réduire les sections des poutres et d’utiliser une quantité moindre de bois dans un bâtiment. Cela engendrera des coûts de transport et des coûts reliés au temps d’assemblage réduits. De plus, un connecteur plus résistant permettra d’être utilisé en moins grande quantité dans un assemblage. Les coûts d’approvisionnement en éléments métalliques et le temps de pose sur le site pourront être revus à la baisse. Les avantages d’un nouveau matériau à base de bois plus performant utilisé dans les connexions permettront de promouvoir le bois dans les constructions de grande taille et de réduire l’impact environnemental des bâtiments.