975 resultados para Biodegradable Medical Devices


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The advent of retrievable caval filters was a game changer in the sense, that the previously irreversible act of implanting a medical device into the main venous blood stream of the body requiring careful evaluation of the pros and cons prior to execution suddenly became a "reversible" procedure where potential hazards in the late future of the patient lost most of their weight at the time of decision making. This review was designed to assess the rate of success with late retrieval of so called retrievable caval filters in order to get some indication about reasonable implant duration with respect to relatively "easy" implant removal with conventional means, i.e., catheters, hooks and lassos. A PubMed search (www.pubmed.gov) was performed with the search term "cava filter retrieval after 30 days clinical", and 20 reports between 1994 and 2013 dealing with late retrieval of caval filters were identified, covering approximately 7,000 devices with 600 removed filters. The maximal duration of implant reported is 2,599 days and the maximal implant duration of removed filters is also 2,599 days. The maximal duration reported with standard retrieval techniques, i.e., catheter, hook and/or lasso, is 475 days, whereas for the retrievals after this period more sophisticated techniques including lasers, etc. were required. The maximal implant duration for series with 100% retrieval accounts for 84 days, which is equivalent to 12 weeks or almost 3 months. We conclude that retrievable caval filters often become permanent despite the initial decision of temporary use. However, such "forgotten" retrievable devices can still be removed with a great chance of success up to three months after implantation. Conventional percutaneous removal techniques may be sufficient up to sixteen months after implantation whereas more sophisticated catheter techniques have been shown to be successful up to 83 months or more than seven years of implant duration. Tilting, migrating, or misplaced devices should be removed early on, and replaced if indicated with a device which is both, efficient and retrievable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: A number of medical journals have developed policies for accelerated publication of articles judged by the authors, the editors or the peer reviewers to be of special importance. However, the validity of these judgements is unknown. We therefore compared the importance of articles published on a "fast track" with those published in the usual way. METHODS: We identified 12 "case" articles--6 articles from the New England Journal of Medicine that were prereleased on the journal's Web site before publication in print and 6 "fast-tracked" articles from The Lancet. We then identified 12 "control" articles matched to the case articles according to journal, disease or procedure of focus, theme area and year of publication. Forty-two general internists rated the articles, using 10-point scales, on dimensions addressing the articles' importance, ease of applicability and impact on health outcomes. RESULTS: For each dimension, the mean score for the case articles was significantly higher than the mean score for the control articles: importance to clinical practice 7.6 v. 7.1 respectively (p = 0.001), importance from a public health perspective 6.5 v. 6.0 (p < 0.001), contribution to advancement of medical knowledge 6.2 v. 5.8 (p < 0.001), ease of applicability in practice 7.0 v. 6.5 (p < 0.001), potential impact on health outcomes 6.5 v. 5.9 (p < 0.001). Despite these general findings, in 5 of the 12 matched pairs of articles the control article had a higher mean score than the case article across all the dimensions. INTERPRETATION: The accelerated publication practices of 2 leading medical journals targeted articles that, on average, had slightly higher importance scores than similar articles published in the usual way. However, our finding of higher importance scores for control articles in 5 of the 12 matched pairs shows that current journal practices for selecting articles for expedited publication are inconsistent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The objective of this study was to evaluate the long-term safety and pharmacokinetic profile of a dexamethasone-loaded poly-epsilon-caprolactone (PCL) intravitreous implant. METHODS: The PCL devices were prepared by compression and were inserted into the vitreous of pigmented rabbits. At different time points, vitreous samples were retrieved, and dexamethasone concentration was analyzed by high-performance liquid chromatography. The biodegradation of the implants was evaluated by scanning electron microscopy, and the dexamethasone remaining was evaluated at the end of follow-up. Clinical and histologic examinations were performed to evaluate the implant's tolerance. RESULTS: The PCL implant allows for a controlled and prolonged delivery of dexamethasone in rabbits eyes since it released the drug within the therapeutic range for at least 55 weeks. At 55 weeks approximately 79% of the drug was still present in the implant. Biodegradation study showed that PCL implants degradation is very slow. Clinical and histologic observations showed that the devices were very well tolerated in the rabbit eye. CONCLUSIONS: This study demonstrates the feasibility and tolerance of intravitreous PCL drug delivery systems, which can offer a wide range of applications for intraocular drug delivery because of their controlled and prolonged release over months or even years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article examines, in two Swiss cantons, the interdependence from a medical care point of view of various regions (health planning zones in one canton, political districts in the other). The volume and the destination of patient referrals prescribed by physicians in ambulatory practice are analyzed. The available data (on 1609 referrals) were gathered by the practitioners themselves, during a National Ambulatory Medical Care Survey type study in February-March 1981, in which 203 physicians participated. Several indicators are proposed (including an integration coefficient and an attraction coefficient for each zone); they show marked differences among the regions. This dynamic approach, based on the effective behavior of physicians, appears to be of major interest for health planning purposes (as compared with the frequent practice to use mainly parameters in relation with the availability of care services--the "supply"--numbers of professionals and/or health facilities).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this project, we have investigated new ways of modelling and analysis of human vasculature from Medical images. The research was divided in two main areas: cerebral vasculature analysis and coronary arteries modeling. Regarding cerebral vasculature analysis, we have studed cerebral aneurysms, internal carotid and the Circle of Willis (CoW). Aneurysms are abnormal vessel enlargements that can rupture causing important cerebral damages or death. The understanding of this pathology, together with its virtual treatment, and image diagnosis and prognosis, includes identification and detailed measurement of the aneurysms. In this context, we have proposed two automatic aneurysm isolation method, to separate the abnormal part of the vessel from the healthy part, to homogenize and speed-up the processing pipeline usually employed to study this pathology, [Cardenes2011TMI, arrabide2011MedPhys]. The results obtained from both methods have been also compared and validatied in [Cardenes2012MBEC]. A second important task here the analysis of the internal carotid [Bogunovic2011Media] and the automatic labelling of the CoW, Bogunovic2011MICCAI, Bogunovic2012TMI]. The second area of research covers the study of coronary arteries, specially coronary bifurcations because there is where the formation of atherosclerotic plaque is more common, and where the intervention is more challenging. Therefore, we proposed a novel modelling method from Computed Tomography Angiography (CTA) images, combined with Conventional Coronary Angiography (CCA), to obtain realistic vascular models of coronary bifurcations, presented in [Cardenes2011MICCAI], and fully validated including phantom experiments in [Cardene2013MedPhys]. The realistic models obtained from this method are being used to simulate stenting procedures, and to investigate the hemodynamic variables in coronary bifurcations in the works submitted in [Morlachi2012, Chiastra2012]. Additionally, another preliminary work has been done to reconstruct the coronary tree from rotational angiography, and published in [Cardenes2012ISBI].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En els darrers anys, els sistemes de telemetria per a aplicacions mèdiques han crescut significativament en el diagnòstic i en la monitorització de, per exemple, la glucosa, la pressió de la sang, la temperatura, el ritme cardíac... Els dispositius implantats amplien les aplicacions en medicina i incorpora una millora de qualitat de vida per a l’usuari. Per aquest motiu, en aquest projecte s’estudien dues de les antenes més comuns, com son l’antena dipol i el patch, aquesta última és especialment utilitzada en aplicacions implantades. En l’anàlisi d’aquestes antenes s’han parametritzat característiques relacionades amb l’entorn de l’aplicació, així com també de la pròpia antena, explicant el comportament que, a diferencia amb l’espai lliure, les antenes presenten a canvis d’aquests paràmetres. Al mateix temps, s’ha implementat una configuració per a la mesura d’antenes implantades basat en el model del cos humà d’una capa. Comparant amb els resultats de les simulacions realitzades mitjançant el software FEKO, s’ha obtingut gran correspondència en la mesura empírica d’adaptació i de guany de les antenes microstrip. Gràcies a l’anàlisi paramètric, aquest projecte també presenta diversos dissenys de les antenes optimitzant el guany realitzable amb l’objectiu d’aconseguir la millor comunicació possible amb el dispositiu extern o estació base.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Taking the Royal College of Barcelona (1760 -1843) as a case study this paper shows the development of modern surgery in Spain initiated by Bourbon Monarchy founding new kinds of institutions through their academic activities of spreading scientific knowledge. Antoni Gimbernat was the most famousinternationally recognised Spanish surgeon. He was trained as a surgeon at the Royal College of Surgery in Cadiz and was later appointed as professor of theAnatomy in the College of Barcelona. He then became Royal Surgeon of King Carlos IV and with that esteemed position in Madrid he worked resiliently to improve the quality of the Royal colleges in Spain. Learning human bodystructure by performing hands-on dissections in the anatomical theatre has become a fundamental element of modern medical education. Gimbernat favoured the study of natural sciences, the new chemistry of Lavoisier and experimental physics in the academic programs of surgery. According to the study of a very relevant set of documents preserved in the library, the so-called “juntas literarias”, among the main subjects debated in the clinical sessions was the concept of human beings and diseases in relation to the development of the new experimental sciences. These documents showed that chemistry andexperimental physics were considered crucial tools to understand the unexplained processes that occurred in the diseased and healthy human bodyand in a medico-surgical context. It is important to stress that through these manuscripts we can examine the role and the reception of the new sciences applied to healing arts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives Medical futility at the end of life is a growing challenge to medicine. The goals of the authors were to elucidate how clinicians define futility, when they perceive life-sustaining treatment (LST) to be futile, how they communicate this situation and why LST is sometimes continued despite being recognised as futile. Methods The authors reviewed ethics case consultation protocols and conducted semi-structured interviews with 18 physicians and 11 nurses from adult intensive and palliative care units at a tertiary hospital in Germany. The transcripts were subjected to qualitative content analysis. Results Futility was identified in the majority of case consultations. Interviewees associated futility with the failure to achieve goals of care that offer a benefit to the patient's quality of life and are proportionate to the risks, harms and costs. Prototypic examples mentioned are situations of irreversible dependence on LST, advanced metastatic malignancies and extensive brain injury. Participants agreed that futility should be assessed by physicians after consultation with the care team. Intensivists favoured an indirect and stepwise disclosure of the prognosis. Palliative care clinicians focused on a candid and empathetic information strategy. The reasons for continuing futile LST are primarily emotional, such as guilt, grief, fear of legal consequences and concerns about the family's reaction. Other obstacles are organisational routines, insufficient legal and palliative knowledge and treatment requests by patients or families. Conclusion Managing futility could be improved by communication training, knowledge transfer, organisational improvements and emotional and ethical support systems. The authors propose an algorithm for end-of-life decision making focusing on goals of treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, we present the current state of our work on a linguistically-motivated model for automatic summarization of medical articles in Spanish. The model takes into account the results of an empirical study which reveals that, on the one hand, domain-specific summarization criteria can often be derived from the summaries of domain specialists, and, on the other hand, adequate summarization strategies must be multidimensional, i.e., cover various types of linguistic clues. We take into account the textual, lexical, discursive, syntactic and communicative dimensions. This is novel in the field of summarization. The experiments carried out so far indicate that our model is suitable to provide high quality summarizations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: There is a growing use of mobile devices to access the Internet. We examined whether participants who used a mobile device to access a brief online survey were quicker to respond to the survey but also, less likely to complete it than participants using a traditional web browser. FINDINGS: Using data from a recently completed online intervention trial, we found that participants using mobile devices were quicker to access the survey but less likely to complete it compared to participants using a traditional web browser. More concerning, mobile device users were also less likely to respond to a request to complete a six week follow-up survey compared to those using traditional web browsers. CONCLUSIONS: With roughly a third of participants using mobile devices to answer an online survey in this study, the impact of mobile device usage on survey completion rates is a concern. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01521078.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Port-a-Cath© (PAC) are totally implantable devices that offer an easy and long term access to venous circulation. They have been extensively used for intravenous therapy administration and are particularly well suited for chemotherapy in oncologic patients. Previous comparative studies have shown that these devices have the lowest catheter-related bloodstream infection rates among all intravascular access systems. However, bloodstream infection (BSI) still remains a major issue of port use and epidemiology data for PAC-associated BSI (PABSI) rates differ strongly depending on studies. Also, current literature about PABSI risk factors is scarce and sometimes controversial. Such heterogeneity may depend on type of studied population and local factors. Therefore, the aim of this study was to describe local epidemiology and risk factors for PABSI in adult patients in our tertiary- care university hospital. We conducted a retrospective cohort study in order to describe local epidemiology. We also performed a nested case-control study to identify local risk factors of PABSI. We analyzed medical files of adult patients who had a PAC implanted between January 1st, 2008 and December 31st, 2009 and looked for PABSI occurrence before May 1st, 2011 to define cases. Thirty nine PABSI occurred in this population with an attack rate of 5.8%. We estimated an incidence rate of 0.08/1000 PAC-days using the case-control study. PABSI causative agents were mainly Gram positive cocci (62%). We identified three predictive factors of PABSI by multivariate statistical analysis: neutropenia on outcome date (Odds Ratio [OR]: 4.05; 95% confidence interval [CI]:1.05- 15.66; p=0.042), diabetes (OR: 11.53; 95% CI: 1.07-124.70; p=0.044) and having another infection than PABSI on outcome date (OR: 6.35; 95% CI: 1.50-26.86; p=0.012). Patients suffering from acute or renal failure (OR: 4.26; 95% CI: 0.94-19.21; p=0.059) or wearing another invasive device (OR: 2.99; 95%CI:0.96-9.31; p=0.059) did not have a statistically increased risk for developing a PABSI according to classical threshold (p<0.05) but nevertheless remained close to significance. Our study demonstrated that local epidemiology and microbiology of PABSI in our institution was similar to previous reports. A larger prospective study is required to confirm our results or to test preventive measures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monitoring of posture allocations and activities enables accurate estimation of energy expenditure and may aid in obesity prevention and treatment. At present, accurate devices rely on multiple sensors distributed on the body and thus may be too obtrusive for everyday use. This paper presents a novel wearable sensor, which is capable of very accurate recognition of common postures and activities. The patterns of heel acceleration and plantar pressure uniquely characterize postures and typical activities while requiring minimal preprocessing and no feature extraction. The shoe sensor was tested in nine adults performing sitting and standing postures and while walking, running, stair ascent/descent and cycling. Support vector machines (SVMs) were used for classification. A fourfold validation of a six-class subject-independent group model showed 95.2% average accuracy of posture/activity classification on full sensor set and over 98% on optimized sensor set. Using a combination of acceleration/pressure also enabled a pronounced reduction of the sampling frequency (25 to 1 Hz) without significant loss of accuracy (98% versus 93%). Subjects had shoe sizes (US) M9.5-11 and W7-9 and body mass index from 18.1 to 39.4 kg/m2 and thus suggesting that the device can be used by individuals with varying anthropometric characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The objectives were to identify the social and medical factors associated with emergency department (ED) frequent use and to determine if frequent users were more likely to have a combination of these factors in a universal health insurance system. METHODS: This was a retrospective chart review case-control study comparing randomized samples of frequent users and nonfrequent users at the Lausanne University Hospital, Switzerland. The authors defined frequent users as patients with four or more ED visits within the previous 12 months. Adult patients who visited the ED between April 2008 and March 2009 (study period) were included, and patients leaving the ED without medical discharge were excluded. For each patient, the first ED electronic record within the study period was considered for data extraction. Along with basic demographics, variables of interest included social (employment or housing status) and medical (ED primary diagnosis) characteristics. Significant social and medical factors were used to construct a logistic regression model, to determine factors associated with frequent ED use. In addition, comparison of the combination of social and medical factors was examined. RESULTS: A total of 359 of 1,591 frequent and 360 of 34,263 nonfrequent users were selected. Frequent users accounted for less than a 20th of all ED patients (4.4%), but for 12.1% of all visits (5,813 of 48,117), with a maximum of 73 ED visits. No difference in terms of age or sex occurred, but more frequent users had a nationality other than Swiss or European (n = 117 [32.6%] vs. n = 83 [23.1%], p = 0.003). Adjusted multivariate analysis showed that social and specific medical vulnerability factors most increased the risk of frequent ED use: being under guardianship (adjusted odds ratio [OR] = 15.8; 95% confidence interval [CI] = 1.7 to 147.3), living closer to the ED (adjusted OR = 4.6; 95% CI = 2.8 to 7.6), being uninsured (adjusted OR = 2.5; 95% CI = 1.1 to 5.8), being unemployed or dependent on government welfare (adjusted OR = 2.1; 95% CI = 1.3 to 3.4), the number of psychiatric hospitalizations (adjusted OR = 4.6; 95% CI = 1.5 to 14.1), and the use of five or more clinical departments over 12 months (adjusted OR = 4.5; 95% CI = 2.5 to 8.1). Having two of four social factors increased the odds of frequent ED use (adjusted = OR 5.4; 95% CI = 2.9 to 9.9), and similar results were found for medical factors (adjusted OR = 7.9; 95% CI = 4.6 to 13.4). A combination of social and medical factors was markedly associated with ED frequent use, as frequent users were 10 times more likely to have three of them (on a total of eight factors; 95% CI = 5.1 to 19.6). CONCLUSIONS: Frequent users accounted for a moderate proportion of visits at the Lausanne ED. Social and medical vulnerability factors were associated with frequent ED use. In addition, frequent users were more likely to have both social and medical vulnerabilities than were other patients. Case management strategies might address the vulnerability factors of frequent users to prevent inequities in health care and related costs.