999 resultados para Acoustic index


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode Division Multiplexing is performed over 2km and 8km of 50μm graded-index multimode fibre using (de)multiplex phase masks based around optical vortex modes to transmit 2x56Gbps QPSK signals without MIMO equalization. © 2013 OSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multilevel PAM is investigated for a LED-based SI-POF link. Using PAM-8, transmission at a record 3 Gbit/s is demonstrated for a maximum length of 25 m step index POF with offline post-receiver processing. © 2013 OSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we develop a linear technique that predicts how the stability of a thermo-acoustic system changes due to the action of a generic passive feedback device or a generic change in the base state. From this, one can calculate the passive device or base state change that most stabilizes the system. This theoretical framework, based on adjoint equations, is applied to two types of Rijke tube. The first contains an electrically-heated hot wire and the second contains a diffusion flame. Both heat sources are assumed to be compact so that the acoustic and heat release models can be decoupled. We find that the most effective passive control device is an adiabatic mesh placed at the downstream end of the Rijke tube. We also investigate the effects of a second hot wire and a local variation of the cross-sectional area but find that both affect the frequency more than the growth rate. This application of adjoint sensitivity analysis opens up new possibilities for the passive control of thermo-acoustic oscillations. For example, the influence of base state changes can be combined with other constraints, such as that the total heat release rate remains constant, in order to show how an unstable thermo-acoustic system should be changed in order to make it stable. Copyright © 2013 by ASME.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Planar plasmonic devices are becoming attractive for myriad applications, owing to their potential compatibility with standard microelectronics technology and the capability for densely integrating a large variety of plasmonic devices on a chip. Mitigating the challenges of using plasmonics in on-chip configurations requires precise control over the properties of plasmonic modes, in particular their shape and size. Here we achieve this goal by demonstrating a planar plasmonic graded-index lens focusing surface plasmons propagating along the device. The plasmonic mode is manipulated by carving subwavelength features into a dielectric layer positioned on top of a uniform metal film, allowing the local effective index of the plasmonic mode to be controlled using a single binary lithographic step. Focusing and divergence of surface plasmons is demonstrated experimentally. The demonstrated approach can be used for manipulating the propagation of surface plasmons, e.g., for beam steering, splitting, cloaking, mode matching, and beam shaping applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We experimentally demonstrate a frequency modulation locked servo loop, locked to a resonance line of an on-chip microdisk resonator in a silicon nitride platform. By using this approach, we demonstrate real-time monitoring of refractive index variations with a precision approaching 10(-7) RIU, using a moderate Q factor of 10(4). The approach can be applied for intensity independent, dynamic and precise index of refraction monitoring for biosensing applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study has developed an improved subjective approach of classification in conjunction with Step wise DFA analysis to discriminate Chinese sturgeon signals from other targets. The results showed that all together 25 Chinese sturgeon echo-signals were detected in the spawning ground of Gezhouba Dam during the last 3 years, and the identification accuracy reached 90.9%. In Stepwise DFA, 24 out of 67 variables were applied in discrimination and identification. PCA combined with DFA was then used to ensure the significance of the 24 variables and detailed the identification pattern. The results indicated that we can discriminate Chinese sturgeon from other fish species and noise using certain descriptors such as the behaviour variables, echo characteristics and acoustic cross-section characteristics. However, identification of Chinese sturgeon from sediments is more difficult and needs a total of 24 variables. This is due to the limited knowledge about the acoustic-scattering properties of the substrate regions. Based on identified Chinese sturgeon individuals, 18 individuals were distributed in the region between the site of Gezhouba Dam and Miaozui reach, with a surface area of about 3.4 km(2). Seven individuals were distributed in the region between Miaozui and Yanshouba reach, with a surface area of about 13 km(2).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We experimentally demonstrate the planar focusing of Surface Plasmon Polaritons using space variant PMMA subwavelength features on top of a metallic film. Focusing is obtained by creating an effective graded refractive index profile. © 2012 OSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vibration and acoustic analysis at higher frequencies faces two challenges: computing the response without using an excessive number of degrees of freedom, and quantifying its uncertainty due to small spatial variations in geometry, material properties and boundary conditions. Efficient models make use of the observation that when the response of a decoupled vibro-acoustic subsystem is sufficiently sensitive to uncertainty in such spatial variations, the local statistics of its natural frequencies and mode shapes saturate to universal probability distributions. This holds irrespective of the causes that underly these spatial variations and thus leads to a nonparametric description of uncertainty. This work deals with the identification of uncertain parameters in such models by using experimental data. One of the difficulties is that both experimental errors and modeling errors, due to the nonparametric uncertainty that is inherent to the model type, are present. This is tackled by employing a Bayesian inference strategy. The prior probability distribution of the uncertain parameters is constructed using the maximum entropy principle. The likelihood function that is subsequently computed takes the experimental information, the experimental errors and the modeling errors into account. The posterior probability distribution, which is computed with the Markov Chain Monte Carlo method, provides a full uncertainty quantification of the identified parameters, and indicates how well their uncertainty is reduced, with respect to the prior information, by the experimental data. © 2013 Taylor & Francis Group, London.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cetaceans produce sound signals frequently. Usually, acoustic localization of cetaceans was made by cable hydrophone arrays and multichannel recording systems. In this study, a simple and relatively inexpensive towed acoustic system consisting of two miniature stereo acoustic data-loggers is described for localization and tracking of finless porpoises in a mobile survey. Among 204 porpoises detected acoustically, 34 individuals (similar to 17%) were localized, and 4 of the 34 localized individuals were tracked. The accuracy of the localization is considered to be fairly high, as the upper bounds of relative distance errors were less than 41% within 173 m. With the location information, source levels of finless porpoise clicks were estimated to range from 180 to 209 dB re 1 mu Pa pp at 1 m with an average of 197 dB (N=34), which is over 20 dB higher than that estimated previously from animals in enclosed waters. For the four tracked porpoises, two-dimensional swimming trajectories relative to the moving survey boat, absolute swimming speed, and absolute heading direction are deduced by assuming the animal movements are straight and at constant speed in the segment between two consecutive locations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the Simrad EY60 split-beam echosounder, the spawning aggregation of Megalobrama hoffmanni was observed at the Luopang spawning grounds in the Pearl River, China, from April 19 to 22 2006. With the boat anchored, the transducer was stationary and was aimed horizontally to monitor the migration of the fish. Using fishery information, the echoes of M. hoffmanni were identified. The results showed that the spawning aggregation of M. hoffmanni at Luopang was obvious and easy to discriminate. The target strength of M hoffmanni in situ ranged from -33.8 dB to -52.3 dB (average 42.2dB). The aggregation of M. hoffmanni was obviously affected by light. With a speed of -0.31 m/s, 88.9% of the spawning stocks migrated upstream. Most M hoffmanni were recorded moving near the bottom. Their distinctive acoustic signature demonstrated the suitability of the stationary acoustic observation for M. hoffmanni identification and discrimination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper the acoustic characterization of a layer of carbon nanotubes (CNT) deposited on AlN solidly mounted resonators is described. The structure of the CNT layer is analyzed by scanning electron microscopy and Raman spectroscopy. The electrical sheet resistance is derived from 4 point probe measurements and from the fitting of the electrical response of the resonators. Values of sheet resistance around 100 Ω/□ are measured. The longitudinal acoustic velocity is derived from the fitting of the electrical response of the resonators using Mason's model, by adjusting the overtones produced in the CNT layer. A mean value of 62000 m·s-1 is obtained, although some devices show values around 90000 m·s -1, close to the theoretical value of 100000 m·s-1. Some results on the deposition of CNT layers on metallic top electrodes and their influence on the performance of the resonator are also presented. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We experimentally demonstrate the planar focusing of Surface Plasmon Polaritons using space variant PMMA subwavelength features on top of a metallic film. Focusing is obtained by creating an effective graded refractive index profile. © OSA 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The detection performance regarding stationary acoustic monitoring of Yangtze finless porpoises Neophocaena phocaenoides asiaeorientalis was compared to visual observations. Three stereo acoustic data loggers (A-tag) were placed at different locations near the confluence of Poyang Lake and the Yangtze River, China. The presence and number of porpoises were determined acoustically and visually during each 1-min time bin. On average, porpoises were acoustically detected 81.7 +/- 9.7% of the entire effective observation time, while the presence of animals was confirmed visually 12.7 +/- 11.0% of the entire time. Acoustic monitoring indicated areas of high and low porpoise densities that were consistent with visual observations. The direction of porpoise movement was monitored using stereo beams, which agreed with visual observations at all monitoring locations. Acoustic and visual methods could determine group sizes up to five and ten individuals, respectively. While the acoustic monitoring method had the advantage of high detection probability, it tended to underestimate group size due to the limited resolution of sound source bearing angles. The stationary acoustic monitoring method proved to be a practical and useful alternative to visual observations, especially in areas of low porpoise density for long-term monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a chip-scale microbubble-based biosensing platform. An encapsulated microbubble oscillates acoustically in liquid when exposed to an ultrasound field with its resonant frequency set by shell parameters. Changes in the resonant frequency of the microbubble can be used to monitor analyte-binding events on the shell. A device concept is proposed where ultrasonic transducers are integrated within a microfluidic channel, inside which electrodes are patterned for differential measurements of microbubble impedance. This device enables simultaneous measurements of the acoustic and electrical response of the microbubble, from which both mechanical and electrical parameters can be extracted. These parameters are used to provide a signature of the analyte. This paper presents acoustic and electrical models of the microbubbles, with the effect of shell parameters being thoroughly discussed. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the design and modelling of an integrated device for acoustic resonance spectroscopy (ARS). Miniaturisation of such platforms can be achieved using MEMS technology thereby enabling scaling of device dimensions to investigate smaller specimens while simultaneously operating at higher frequencies. We propose an integrated device where the transducers are mounted in close proximity with the specimen to be analysed (e.g. by integrating ultrasound transducers within a microfluidic channel). A finite element (FE) model and a simplified analytical model have been constructed to predict the acoustic response of a sample embedded in such a device configuration. A FE simulation is performed in COMSOL by embedding the piezoelectric transducers in representative fluid media. Resonant frequencies associated with the measurement can be extracted from this data. The response of various media modelled through FEA matches with analytical predictions for a range of biological media. A variety of biological media may be identified by using the measured resonant frequencies as a signature of relevant physical characteristics. The paper establishes the modelling basis of an integrated acoustic resonant spectrometer that is then applied to examine the impact of geometrical scaling on system resolution. © 2013 IEEE.