1000 resultados para 90° holographic recording geometry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A systematic computational fluid dynamics (CFD) approach has been applied to design the geometry of the channels of a three-dimensional (thick-walled) screen comprising upstream and downstream sets of elongated channels positioned at an angle of 90 degrees with respect to each other. Such a geometry of the thick-wall screen can effectively drop the ratio of the maximum flow velocity to mean flow velocity below 1.005 in a downstream microstructured reactor at low Reynolds numbers. In this approach the problem of flow equalization reduces to that of flow equalization in the first and second downstream channels of the thick-walled screen. In turn, this requires flow equalization in the corresponding cross-sections of the upstream channels. The validity of the proposed design method was assessed through a case study. The effect of different design parameters on the flow non-uniformity in the downstream channels has been established. The design equation is proposed to calculate the optimum values of the screen parameters. The CFD results on flow distribution were experimentally validated by Laser Doppler Anemometry measurements in the range of Reynolds numbers from 6 to 113. The measured flow non-uniformity in the separate reactor channels was below 2%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report what is to our knowledge the first demonstration of a transient x-ray laser pumped by a 350-fs pulse in a traveling-wave irradiation geometry. For a 500-fs pump pulse the traveling-wave irradiation was found to have a strong effect on enhancing the Ni-like silver 4d-4p lasing emission at 13.9 nm. The signal enhancement was significantly less when the pulse duration was lengthened to 1.7 ps. The experimental observations are well reproduced by a simple model when the duration of gain is taken of the order of 15-20 ps. For the 500-fs pulse a gain coefficient of 14.5 cm(-1) was measured for plasma lengths up to 7 mm. Refraction of the amplified photons is believed to be the main cause of the limitation of the effective amplification length. (C) 2000 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aluminium thin films were deposited by a laser ablation technique from solid cylindrical targets rotated on a lead screw. Both smooth-surfaced targets and targets with screw threads cut into the area to he irradiated were used. The targets were irradiated with a focused circular spot size of 2.5 mm in diameter, at a power density equal to 5.4 +/- 0.2 x 10(8) W cm(-2). The polar distribution of the ablated atomic material was found to vary as a function of the target screw thread pitch, with the exponent n, in the polar distribution f(theta) = cos(n) theta, varying from 13.5 +/- 1.3 for no pitch to a minimum of 5 +/- 0.7 for a screw thread pitch of 0.2 mm. The use of such novel target geometries forms a possible basis for increasing thickness uniformity during the pulsed laser deposition of thin films.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The spatial coherence of a nanosecond pulsed germanium collisionally excited x-ray laser is measured experimentally for three target configurations. The diagnostic is based on Young's slit interference fringes with a dispersing element to resolve the 23.2- and 23.6-nm spectral lines. Target configurations include a double-slab target, known as the injector, and geometries in which the injector image is image relayed to seed either an additional single-slab target or a second double-slab target. A special feature of this study is the observation of the change in the apparent source size with angle of refraction across the diverging laser beam. Source sizes derived with a Gaussian source model decrease from 44 mu m for the injector target by a variable factor of as much as 2, according to target configuration, for beams leaving the additional amplifiers after strong refraction in the plasma. (C) 1998 Optical Society of America [S0740-3224(98)00810-8].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a PW (0.5 ps/500J) laser system to demonstrate fast heating of imploded core plasmas using a hollow cone shell target. Significant enhancement of thermal neutron yield has been realized with PW-laser heating, confirming that the high heating efficiency is maintained as the short-pulse laser power is substantially increased to a value nearly equivalent to the ignition condition. It appears that the efficient heating is realized by the guiding of the PW laser pulse energy within the hollow cone and by self-organized relativistic electron transport. Based on the experimental results, we are developing a 10kJ-PW laser system to study the fast heating physics of high-density plasmas at an ignition-equivalent temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Activating mutations of the FMS-like tyrosine kinase 3 gene (FLT3) occur in approximately one-third of patients with acute myeloid leukaemia (AML) and predict for a poor outcome. Heat shock protein 90 (Hsp90) is a molecular chaperone that is frequently used by cancer cells to stabilise mutant oncoproteins. Mutant FLT3 is chaperoned by Hsp90 in primary AML blasts whereas unmutated FLT3 is not, making Hsp90 inhibitors potentially useful therapeutically. The present study showed that inhibition of Hsp90 by 17-allylamino-17-demethoxygeldanamycin (17-AAG) was cytotoxic to primary AML cells expressing mutant FLT3. Inhibition of Hsp90 results in altered downstream signalling effects in primary AML cells with disruption of Janus kinase-signal transducer and activator of transcription (JAK-STAT), mitogen-activated protein kinase and phosphatidylinositol 3/AKT signalling pathways. Co-treatment of blasts with 17-AAG and cytarabine resulted in a synergistic or additive effect in approximately 50% of AML cases tested. Our results confirm that Hsp90 is a valid molecular target in the therapy of AML. Inhibition of Hsp90 in parallel with conventional AML therapies may have particular benefit in those patients with the poor prognostic FLT3 mutant disease.