994 resultados para 500 MHZ


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: to address the social aspects of pregnancy and the views of pregnant women regarding prenatal assistance in Brazil. Design: this qualitative study was focused on describing the Social Representations of prenatal care held by pregnant women. The discourse of the collective subject (DCS) framework was used to analyse the data collected, within the theoretical background of social representations, as proposed and developed by Serge Moscovici. Participants and setting: 21 pregnant women who were users of the publicly funded Brazilian unified health-care system and resided in the area served by its family health programme in a low- to middle-income neighbourhood on the outskirts of Campo Grande, the capital of the state of Mato Grosso do Sul, in southwestern Brazil. Data were collected by conducting in-depth, face-to-face interviews from January to October 2006. Findings: all participants were married. Formal education of the participants was less than five years in four cases, between five and eight years in six cases, and greater than 11 years in 10 cases. Nine participants had informal jobs and earned up to US$ 200 per month, four paricipants had administrative jobs and earned over US$ 500 per month, and eight participants did not work. No specific racial/ethnic background predominated. Lack of adherence to prenatal care allowed for the identification of two DCS themes: `organisation of prenatal care services` and `lifestyle features`. Key conclusions: the respondents were found to have negative feelings about pregnancy which manifest as many fears, including the fear of harming their children`s health, of being punished during labour, and of being reprimanded by health-care professionals for overlooking their prenatal care, in addition to the insecurity felt towards the infant and self. Implications for practice: the findings reveal that communication between pregnant women and healthcare professionals has been ineffective and that prenatal care has not been effective for the group interviewed-features that are likely to be found among other low- to middle-income groups living elsewhere in Brazil. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Considering the difficulties in finding good-quality images for the development and test of computer-aided diagnosis (CAD), this paper presents a public online mammographic images database free for all interested viewers and aimed to help develop and evaluate CAD schemes. The digitalization of the mammographic images is made with suitable contrast and spatial resolution for processing purposes. The broad recuperation system allows the user to search for different images, exams, or patient characteristics. Comparison with other databases currently available has shown that the presented database has a sufficient number of images, is of high quality, and is the only one to include a functional search system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An investigation was performed regarding the application of a mechanically stirred anaerobic sequencing batch biofilm reactor containing immobilized biomass on inert polyurethane foam (AnSBBR) to the treatment of soluble metalworking fluids to remove organic matter and produce methane. The effect of increasing organic matter and reactor fill time, as well as shock load, on reactor stability and efficiency have been analyzed. The 5-L AnSBBR was operated at 30 A degrees C in 8-h cycles, agitation of 400 rpm, and treated 2.0 L effluent per cycle. Organic matter was increased by increasing the influent concentration (500, 1,000, 2,000, and 3,000 mg chemical oxygen demand (COD)/L). Fill times investigated were in the batch mode (fill time 10 min) and fed-batch followed by batch (fill time 4 h). In the batch mode, organic matter removal efficiencies were 87%, 86%, and 80% for influent concentrations of 500, 1,000, and 2,000 mgCOD/L (1.50, 3.12, and 6.08 gCOD/L.d), respectively. At 3,000 mgCOD/L (9.38 gCOD/L.d), operational stability could not be achieved. The reactor managed to maintain stability when a shock load twice as high the feed concentration was applied, evidencing the robustness of the reactor to potential concentration variations in the wastewater being treated. Increasing the fill time to 4 h did not improve removal efficiency, which was 72% for 2,000 mgCOD/L. Thus, gradual feeding did not improve organic matter removal. The concentration of methane formed at 6.08 gCOD/L was 5.20 mmolCH(4), which corresponded to 78% of the biogas composition. The behavior of the reactor during batch and fed-batch feeding could be explained by a kinetic model that considers organic matter consumption, production, and consumption of total volatile acids and methane production.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The removal of sulfate and organic matter was assessed in an ASBR, which treated wastewater containing 500 mg COD L(-1) (3 g COD L(-1) d(-1)) in 8 h-cycles at 30 degrees C. The wastewater was enriched with sulfate at [COD/SO(4)(2-]) ratios of 1.34, 0.67 and 0.34 (8.8,4.5 and 2.2 gSO(4)(2-) L(-1) d(-1)). For each COD/[SO(4)(2-)] ratio fill times used were: 10 min (batch), 3 and 6 h (fed-batch), achieving sulfate reduction of 30%, 72% and 72% (COD/[SO(4)(2-)] of 1.34); 25%, 58% and 55% (COD/[SO(4)(2-)] of 0.67) and 23%, 37% and 27% (COD/[SO(4)(2-)] of 0.34), respectively, and organic matter removal of 87%, 68% and 80% (COD/[SO(4)(2-)] of 1.34); 78%, 75% and 69% (COD/[SO(4)(2-)] of 0.67) and 85%, 84% and 83% (COD/[SO(4)(2-)] of 0.34), respectively. The results showed that fed-batch operation improved sulfate reduction, whereas organic matter removals were similar for batch and fed-batch operation. In addition, increase in sulfate loading in the fed-batch operation improved organic matter removal. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study evaluated the degradation of formaldehyde in a bench-scale anaerobic sequencing batch reactor, which contained biomass immobilized in polyurethane foam matrices. The reactor was operated for 212 days at 35 C with 8 h sequential cycles, under different affluent formaldehyde concentrations ranging from 31.6 to 1104.4 mg/L (formaldehyde loading rates from 0.08 to 2.78 kg/m(3) day). The results indicate excellent reactor stability and over 99% efficiency in formaldehyde removal, with average effluent formaldehyde concentration of 3.6 + 1.7 mg/L. Formaldehyde degradation rates increased from 204.9 to 698.3 mg/L h as the initial concentration of formaldehyde was increased from around 100 to around 1100 mg/L. However, accumulation of organic matter was observed in the effluent (chemical oxygen demand (COD) values above 500 mg/L) due to the presence of non-degraded organic acids, especially acetic and propionic acids, This observation poses an important question regarding the anaerobic route of formaldehyde degradation, which might differ Substantially from that reported in the literature. The anaerobic degradation pathway can be associated with the formation of long-chain oligomers from formaldehyde. Such long- or short-chain polymers are probably the precursors of organic acid formation by means of acidogenic anaerobic microorganisms. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An investigation was performed on the effect of temperature and organic load on the stability and efficiency of a 1.8-L fluidized-bed anaerobic sequencing batch reactor (ASBR), containing granulated biomass. Assays were carried out employing superficial up How velocity of 7 m/h, total cycle length of 6 h and synthetic wastewater volume of 1.3 L per cycle. The fluidized-bed ASH was operated at 15, 20, 25 and 30 degrees C with influent organic matter concentrations of 500 and 1000 mgCOD/L The system showed stability under all conditions and presented filtered samples removal efficiency ranging from 79 to 86%. A first-order kinetic model could be fitted to the experimental values of the organic matter concentration profiles. The specific kinetic parameter values of this model ranged from 0.0435 to 0.2360 L/(gTVS h) at the implemented operation conditions. in addition, from the slope of an Arrhenius plot, the activation energy values were calculated to be 16,729 and 12,673 cal/mol for operation with 500 and 1000 mgCOD/L, respectively. These results show that treatment of synthetic wastewater. with concentration of 500 mgCOD/L, was more sensitive to temperature variations than treatment of the same residue with concentration of 1000 mgCOD/L. Comparing the activation energy value for operation at 500 mgCOD/L with the value obtained by Agibert et al. (S.A. Agibert, M.B. Moreira, S.M. Ratusznei, J.A.D. Rodrigues, M. Zaiat, E. Foresti. Influence of temperature on performance of an ASBBR with circulation applied to treatment of low-strength wastewater. journal of Applied Biochemistry and Biotechnology, 136 (2007) 193-206) in an ASBBR treating the same wastewater at the same concentration, the value obtained in the fluidized-bed ASBR showed to be superior, indicating that treatment of synthetic wastewater in a reactor containing granulated biomass was more sensitive to temperature variations than the treatment using immobilized biomass. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to estimate the first-order intrinsic kinetic constant (k(1)) and the liquid-phase mass transfer coefficient (k(c)) in a bench-scale anaerobic sequencing batch biofilm reactor (ASBBR) fed with glucose. A dynamic heterogeneous mathematical model, considering two phases (liquid and solid), was developed through mass balances in the liquid and solid phases. The model was adjusted to experimental data obtained from the ASBBR applied for the treatment of glucose-based synthetic wastewater with approximately 500 mg L-1 of glucose, operating in 8 h batch cycles, at 30 degrees C and 300 rpm. The values of the parameters obtained were 0.8911 min(-1) for k(1) and 0.7644 cm min(-1) for kc. The model was validated utilizing the estimated parameters with data obtained from the ASBBR operating in 3 h batch cycles, with a good representation of the experimental behavior. The solid-phase mass transfer flux was found to be the limiting step of the overall glucose conversion rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Safe application of the anaerobic sequencing biofilm batch reactor (ASBBR) still depends on deeper insight into its behavior when faced with common operational problems in wastewater treatments such as tolerance to abrupt variations in influent concentration, so called shock loads. To this end the current work shows the effect of organic shock loads on the performance of an ASBBR, with a useful volume of 5 L, containing 0.5-cm polyurethane cubes and operating at 30 degrees C with mechanical stirring of 500 rpm. In the assays 2 L of two types of synthetic wastewater were treated in 8-h cycles. Synthetic wastewater I was based on sucrose-amide-cellulose with concentration of 500 mg COD/L and synthetic wastewater II was based on volatile acids with concentration ranging from 500 to 2000 mg COD/L. Organic shock loads of 2-4 times the operation concentration were applied during one and two cycles. System efficiency was monitored before and after application of the perturbation. When operating with concentrations from 500 to 1000 mg COD/L and shock loads of 2-4 times the influent concentration during one or two cycles the system was able to regain stability after one cycle and the values of organic matter, total and intermediate volatile acids, bicarbonate alkalinity and pH were similar to those prior to the perturbations. At a concentration of 2000 mg COD/L the reactor appeared to be robust, regaining removal efficiencies similar to those prior to perturbation at shock loads twice the operation concentration lasting one cycle and stability was recovered after two cycles. However, for shock loads twice the operation concentration during two cycles and shock loads four times the operation concentration during one or two cycles filtered sample removal efficiency decreased to levels different from those prior to perturbation, on an average of 90-80%, approximately, yet the system managed to attain stability within two cycles after shock application. Therefore, this investigation envisions the potential of full scale application of this type of bioreactor which showed robustness to organic shock loads, despite discontinuous operation and the short times available for treating total wastewater volume. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An investigation has been performed on the effect of liquid phase recirculation velocity and increasing influent concentration on the stability and efficiency of an anaerobic sequencing batch reactor (ASBR) containing granular biomass. The reactor treated 1.3 L synthetic wastewater at 30 degrees C in 6 h cycles. Initially the effect of recirculation velocity was investigated employing velocities of 5, 7 and 10 m/h and influent concentration of 500 mg COD/L. At these velocities, filtered sample organic matter removal efficiencies were 83, 85 and 84%, respectively. A first order kinetic model could also be fitted to the experimental organic matter concentration profiles. The kinetic parameter values of this model were 1.35, 2.36 and 1.00 h(-1) at the recirculation velocities of 5, 7 and 10 m/h, respectively. The recirculation velocity of 7 m/h was found to be the best operating strategy and this value was maintained while the influent concentration was altered in order to verify system efficiency and stability at increasing organic load. Influent concentration of 1000 mg COD/L resulted in filtered sample organic matter removal efficiency of 80%, and a first order kinetic parameter value of 1.14 h(-1), whereas the concentration of 1500 mg COD/L resulted in an efficiency of 82% and a kinetic parameter value of 1.31 h(-1). (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The superiority of superaustenitic stainless steel (SASS) lies in its good weldability and great resistance to stress corrosion and pitting, because of its higher chromium, molybdenum, and nitrogen contents, when compared to general stainless steels. However, some of its applications are limited by very poor wear behavior. Plasma-nitriding is a very effective treatment for producing wear resistant and hard surface layers on stainless steels without compromising the corrosion resistance. In this work, UNS S31254 SASS samples were plasma-nitrided at three different temperatures (400, 450, and 500 degrees C), under a pressure of 500 Pa, for 5 h, in order to verify the influence of the temperature on the morphology, wear, and corrosion behavior of the modified surface layers. The plasma-nitrided samples were analyzed by means of optical microscopy, micro-hardness. X-ray diffraction, wear, and corrosion tests. Wear tests were conducted in a fixed ball micro-wear machine and corrosion behavior was carried out in natural sea water by means of potentiodynamic polarization curves. For the sample which was plasma-nitrided at 400 degrees C, only the expanded austenite phase was observed, and for the treatments performed at 450 and 500 degrees C, chromium nitrides (CrN and Cr(2)N) were formed in addition to the expanded austenite. Wear volume and Knoop surface hardness increased as the plasma-nitriding temperature increased. Higher wear rates were observed at high temperatures, probably due to the increment on layer fragility. The sample modified at 400 degrees C exhibited the best corrosion behavior among all the plasma-nitriding conditions. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the frequent use of stepping motors in robotics, automation, and a variety of precision instruments, they can hardly be found in rotational viscometers. This paper proposes the use of a stepping motor to drive a conventional constant-shear-rate laboratory rotational viscometer to avoid the use of velocity sensor and gearbox and, thus, simplify the instrument design. To investigate this driving technique, a commercial rotating viscometer has been adapted to be driven by a bipolar stepping motor, which is controlled via a personal computer. Special circuitry has been added to microstep the stepping motor at selectable step sizes and to condition the torque signal. Tests have been carried out using the prototype to produce flow curves for two standard Newtonian fluids (920 and 12 560 mPa (.) s, both at 25 degrees C). The flow curves have been obtained by employing several distinct microstep sizes within the shear rate range of 50-500 s(-1). The results indicate the feasibility of the proposed driving technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A laboratory scale activated sludge sequencing batch reactor was operated in order to obtain total removal of influent ammonia (200; 300 and 500 mg NH(3)-N.L(-1)) with sustained nitrite accumulation at the end of the aerobic stages with phenol (1,000 mg C(6)H(5)OH.L(-1)) as the carbon source for denitrifying microorganisms during the anoxic stages. Ammonia removal above 95% and ratios of (NO(2)(-)-N / (NO(2)(-)-N + NO(3)(-)-N)) ranging from 89 to 99% were obtained by controlling the dissolved oxygen concentration (1.0 mg O(2).L(-1)) and the pH value of 8.3 during the aerobic stages. Phenol proved to be an adequate source of carbon for nitrogen removal via nitrite with continuous feeding throughout part of the anoxic stage. Nitrite concentrations greater than 70.0 mg NO(2)(-)-N.L(-1) inhibited the biological denitritation process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Austenitic stainless steels cannot be conventionally surface treated at temperatures close to 550 degrees C due to intense precipitation of nitrides or carbides. Plasma carburizing allows introducing carbon in the steel at temperatures below 500 degrees C without carbide precipitation. Plasma carburizing of AISI 316L was carried out at 480 degrees C and 400 degrees C, during 20 h, using CH(4) as carbon carrier gas. The results show that carbon expanded austenite (gamma(c)), 20 mu m in depth, was formed on the surface after the 480 degrees C treatment. Carbon expanded austenite (gamma(c)), 8 mu m in depth, was formed on the surface after the 400 degrees C treatment. DRX results showed that the austenitic FCC lattice parameter increases from 0.358 nm to 0.363 nm for the 400 degrees C treatment and to 0.369 nm for the 480 degrees C treatment, giving an estimation of circa 10 at.% carbon content for the latter. Lattice distortion, resulting from the expansion and the associated compressive residual stresses increases the surface hardness to 1040 HV(0.025). Micro-scale tensile tests were conducted on specimens prepared with the conditions selected above, which has indicated that the damage imposed to the expanded austenite layer was more easily related to each separated grain than to the overall macro-scale stresses imposed by the tensile test. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The therapeutic ultrasound (US) is one of the resources mostly used by physiotherapists; however the use of uncalibrated equipments results in inefficient or even harmful therapies to the patient. In this direction, the objective of this study was to evaluate the performance and the procedures of utilization and maintenance of US in use in clinics and Physical-therapy offices. A questionnaire with questions related to the procedures applied in service during the use of therapeutic ultrasound was applied to physiotherapists. The performance of 31 equipments of 6 different brands and 13 different models was evaluated according to the IEC 61689 norm. The parameters measured were: acoustic power; effective radiating area (AER); non-uniformity ratio of the beam (RBN); maximum effective intensity; acoustic frequency of operation, modulation factor and wave form on pulsate mode. As for the questionnaires, it was evident that the professionals are not concerned about the calibration of the equipment. The results demonstrated that only 32.3% of the equipments were in accordance with the norms for the variables power and effective radiation area. The frequency analysis indicated that 20% of the 3 MHz transducers and 12.5% of the 1 MHz contemplated the norms. In the pulsate mode, 12.7% presented relation rest/duration inside allowed limits. A great variation of the ultrasonic field was observed on the obtained images, which presented beams not centered, sometimes with bifurcation of its apex. The results allow concluding that, although used in therapeutic sessions with the population, none of the equipments presents all the analyzed variables inside technical norms. (C) 2010 Elsevier B. V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Real-time viscosity measurement remains a necessity for highly automated industry. To resolve this problem, many studies have been carried out using an ultrasonic shear wave reflectance method. This method is based on the determination of the complex reflection coefficient`s magnitude and phase at the solid-liquid interface. Although magnitude is a stable quantity and its measurement is relatively simple and precise, phase measurement is a difficult task because of strong temperature dependence. A simplified method that uses only the magnitude of the reflection coefficient and that is valid under the Newtonian regimen has been proposed by some authors, but the obtained viscosity values do not match conventional viscometry measurements. In this work, a mode conversion measurement cell was used to measure glycerin viscosity as a function of temperature (15 to 25 degrees C) and corn syrup-water mixtures as a function of concentration (70 to 100 wt% of corn syrup). Tests were carried out at 1 MHz. A novel signal processing technique that calculates the reflection coefficient magnitude in a frequency band, instead of a single frequency, was studied. The effects of the bandwidth on magnitude and viscosity were analyzed and the results were compared with the values predicted by the Newtonian liquid model. The frequency band technique improved the magnitude results. The obtained viscosity values came close to those measured by the rotational viscometer with percentage errors up to 14%, whereas errors up to 96% were found for the single frequency method.