994 resultados para voltage level


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distribution companies are facing numerous challenges in the near future. Regulation defines correlation between power quality and revenue cap. Companies have to take measures for reliability increase to successfully compete in modern conditions. Most of the failures seen by customers originate in medium voltage networks. Implementation of network automation is the very effective measure to reduce duration and number of outages, and consequently, outage costs. Topic of this diploma work is study of automation investments effect on outage costs and other reliability indices. Calculation model have been made to perform needed reliability calculations. Theoretical study of different automation scenarios has been done. Case feeder from actual distribution company has been studied and various renovation plans have been suggested. Network automation proved to be effective measure for increasing medium voltage network reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Technical analysis of Low Voltage Direct Current (LVDC) distribution systems shows that in LVDC transmission the customer voltage quality is higher. One of the problems in LVDC distribution networks that converters both ends of the DC line are required. Because of the converters produce not pure DC voltage, but some fluctuations as well, the huge electrolytic capacitors are required to reduce voltage distortions in the DC-side. This thesis master’s thesis is focused on calculating required DC-link capacitance for LVDC transmission and estimation of the influence of different parameters on the voltage quality. The goal is to investigate the methods of the DC-link capacitance estimation and location in the transmission line.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Virtual Reality environments that reproduce typical contexts associated with tobacco use may be useful for aiding smoking cessation. The main objective of this study was to assess the capacity of eight environments to produce the craving to smoke and determine the relation of craving to nicotine dependence and level of presence. The results show that all the environments were able to generate the desire to smoke; a direct relation was found between sense of presence and craving.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electron transport in a self-consistent potential along a ballistic two-terminal conductor has been investigated. We have derived general formulas which describe the nonlinear current-voltage characteristics, differential conductance, and low-frequency current and voltage noise assuming an arbitrary distribution function and correlation properties of injected electrons. The analytical results have been obtained for a wide range of biases: from equilibrium to high values beyond the linear-response regime. The particular case of a three-dimensional Fermi-Dirac injection has been analyzed. We show that the Coulomb correlations are manifested in the negative excess voltage noise, i.e., the voltage fluctuations under high-field transport conditions can be less than in equilibrium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A mathematical model of the voltage drop which arises in on-chip power distribution networks is used to compare the maximum voltage drop in the case of different geometric arrangements of the pads supplying power to the chip. These include the square or Manhattan power pad arrangement, which currently predominates, as well as equilateral triangular and hexagonal arrangements. In agreement with the findings in the literature and with physical and SPICE models, the equilateral triangular power pad arrangement is found to minimize the maximum voltage drop. This headline finding is a consequence of relatively simple formulas for the voltage drop, with explicit error bounds, which are established using complex analysis techniques, and elliptic functions in particular.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Invertteritekniikalla voidaan toteuttaa nykyaikainen, monipuolinen ja tehokas pääteaste moneen eri käyttötarkoitukseen. Tässä työssä suunnitellaan invertteripääteaste mittalaite- ja virtalähdesovelluksiin. Suunnittelussa otetaan huomioon muunneltavuus, valmistuskustannukset ja mitat. Näiden kriteerien lisäksi pääteaste suunnitellaan niin, että se täyttää mittalaite- ja virtalähdesovelluksien vaatimat standardit. Pääteasteen teho rajoittuu 500 VA:iin, mutta vaatimukset lähtöjännitteen erimuotoisuudelle aiheuttavat suunnittelulle omat vaikeutensa. Työssä täytyy tutkia, minkälainen tuloaste, invertteri, suodin ja lähtöaste sopivat parhaiten pääteasteen toteutukseen. Sopivien topologioiden löydyttyä pääteaste simuloidaan tietokoneella, jonka jälkeen voidaan suunnitella prototyyppi käytännön testauksia varten. Suunnittelussa päädyttiin seuraaviin topologioihin: Tuloasteeksi valittiin PFC-piiri, joka on nykyaikana pakollinen invertterikäytössä, koska verkkoon palaavat harmoniset yliaaltokomponentit täytyy suodattaa. Invertteritopologiaksi valittiin kokosiltainvertteri, jolla saadaan parhaiten muutettua lähtöjännitteen taajuutta ja amplitudia. Suodintopologiaksi valittiin LC-suodin, jolla saadaan tehokkaasti suodatettua invertterin aiheuttamat harmoniset yliaallot. Lähtöön sijoitetaan muuntaja, jonka muuntosuhdetta muuntamalla saadaan lähtöjännite halutuksi eri käyttötarkoituksia varten.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chromium(III) at the ng L-1 level was extracted using partially silylated MCM-41 modified by a tetraazamacrocyclic compound (TAMC) and determined by inductively coupled plasma optical emision spectrometry (ICP OES). The extraction time and efficiency, pH and flow rate, type and minimum amount of stripping acid, and break- through volume were investigated. The method's enrichment factor and detection limit are 300 and 45.5 pg mL-1, respectively. The maximum capacity of the 10 mg of modified silylated MCM-41 was found to be 400.5±4.7 µg for Cr(III). The method was applied to the determination of Cr(III) and Cr(VI) in the wastewater of the chromium electroplating industry and in environmental and biological samples (black tea, hot and black pepper).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämä diplomityö tutkii korroosionestoa polymeerin ekstruusiolinjalla. Kirjallisuusosassa käsitellään ekstruusiolinjaa, linjalla valmistettavia tuotteita ja niiden jatkojalostusta. Lisäksi kirjallisuusosassa käydään läpi linjalla ilmeneviä korroosiotyyppejä, korroosiota eri prosessilaitteissa, korroosionestossa käytettäviä inhibiittoreita ja eri materiaalien korroosiokestävyyden kartoitusta. Kokeellisessa osassa tutkittiin perushartsin kuivauksen vaikutusta ekstruuderin kaasutilan metanoli-, happi- ja kosteuspitoisuuksiin. Kokeellisessa osassa tutkittiin myös korroosioinhibiittorien I1 ja I2 vaikutusta korroosionestoon, seuraamalla korrodoivalla alueella olleiden ruuvielementtien painohäviöitä. Kaapelitestauksessa selvitettiin inhibiittorien käytön vaikutukset matalajännitekaapelin laatuun. Kuivauksella ei todettu olevan vaikutusta korroosionestoon. Metanolipitoisuus pysyi korkeana ja happipitoisuuden aleneminen ei ollut merkittävää. Kosteuspitoisuuden suuruusluokka selvitettiin. Kuivauksesta huolimatta se pysyi korkeana. Inhibiittorien käytöstä huolimatta ruuvielementit korrodoituivat, mutta inhibiittoria I2 käytettäessä tutkittujen ruuvielementtien painohäviöt olivat pienempiä referenssiajoon verrattuna. Inhibiittori I2:lla ei todettu olevan negatiivisia vaikutuksia matalajännitekaapelin laatuun suoritetuissa ikääntymis- sähköominaisuus- ja ristisilloittumisnopeustesteissä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research around performance measurement and management has focused mainly on the design, implementation and use of performance measurement systems. However, there is little evidence about the actual impacts of performance measurement on the different levels of business and operations of organisations, as well as the underlying factors that lead to a positive impact of performance measurement. The study thus focuses on this research gap, which can be considered both important and challenging to cover. The first objective of the study was to examine the impacts of performance measurement on different aspects of management, leadership and the quality of working life, after which the factors that facilitate and improve performance and performance measurement at the operative level of an organisation were examined. The second objective was to study how these factors operate in practice. The third objective focused on the construction of a framework for successful operative level performance measurement and the utilisation of the factors in the organisations. The research objectives have been studied through six research papers utilising empirical data from three separate studies, including two sets of interview data and one of quantitative data. The study applies mainly the hermeneutical research approach. As a contribution of the study, a framework for successful operative level performance measurement was formed by matching the findings of the current study and performance measurement theory. The study extents the prior research regarding the impacts of performance measurement and the factors that have a positive effect on operative level performance and performance measurement. The results indicate that under suitable circumstances, performance measurement has positive impacts on different aspects of management, leadership, and the quality of working life. The results reveal that for example the perception of the employees and the management of the impacts of performance measurement on leadership style differ considerably. Furthermore, the fragmented literature has been reorganised into six factors that facilitate and improve the performance of the operations and employees, and the use of performance measurement at the operative level of an organisation. Regarding the managerial implications of the study, managers who operate around performance measurement can utilise the framework for example by putting the different phases of the framework into practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The contamination level of silicon oil used as insulation liquid in high-voltage transformers by ascarel (PCBs) is above those permitted by the Brazilian law. Thus new techniques able to detect ascarel, with low operational costs, are very attractive. The present work proposes an analysis of the contamination levels of silicon oil using the following techniques: naphthalene anion radical reaction for ascarel dechlorination; and potentiometry with an ion-selective electrode for chloride ion determination. The data obtained with the proposed methodology agree well with those from the official methodology, (method IEC 61619).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Design: Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Data sources and study selection: Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. Primary outcomes: The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. Results: The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. Conclusions: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The productivity, quality and cost efficiency of welding work are critical for metal industry today. Welding processes must get more effective and this can be done by mechanization and automation. Those systems are always expensive and they have to pay the investment back. In this case it is really important to optimize the needed intelligence and this way needed automation level, so that a company will get the best profit. This intelligence and automation level was earlier classified in several different ways which are not useful for optimizing the process of automation or mechanization of welding. In this study the intelligence of a welding system is defined in a new way to enable the welding system to produce a weld good enough. In this study a new way is developed to classify and select the internal intelligence level of a welding system needed to produce the weld efficiently. This classification contains the possible need of human work and its effect to the weld and its quality but does not exclude any different welding processes or methods. In this study a totally new way is developed to calculate the best optimization for the needed intelligence level in welding. The target of this optimization is the best possible productivity and quality and still an economically optimized solution for several different cases. This new optimizing method is based on grounds of product type, economical productivity, the batch size of products, quality and criteria of usage. Intelligence classification and optimization were never earlier made by grounds of a made product. Now it is possible to find the best type of welding system needed to welddifferent types of products. This calculation process is a universal way for optimizing needed automation or mechanization level when improving productivity of welding. This study helps the industry to improve productivity, quality and cost efficiency of welding workshops.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An oscillating overvoltage has become a common phenomenon at the motor terminal in inverter-fed variable-speed drives. The problem has emerged since modern insulated gate bipolar transistors have become the standard choice as the power switch component in lowvoltage frequency converter drives. Theovervoltage phenomenon is a consequence of the pulse shape of inverter output voltage and impedance mismatches between the inverter, motor cable, and motor. The overvoltages are harmful to the electric motor, and may cause, for instance, insulation failure in the motor. Several methods have been developed to mitigate the problem. However, most of them are based on filtering with lossy passive components, the drawbacks of which are typically their cost and size. In this doctoral dissertation, application of a new active du/dt filtering method based on a low-loss LC circuit and active control to eliminate the motor overvoltages is discussed. The main benefits of the method are the controllability of the output voltage du/dt within certain limits, considerably smaller inductances in the filter circuit resulting in a smaller physical component size, and excellent filtering performance when compared with typical traditional du/dt filtering solutions. Moreover, no additional components are required, since the active control of the filter circuit takes place in the process of the upper-level PWM modulation using the same power switches as the inverter output stage. Further, the active du/dt method will benefit from the development of semiconductor power switch modules, as new technologies and materials emerge, because the method requires additional switching in the output stage of the inverter and generation of narrow voltage pulses. Since additional switching is required in the output stage, additional losses are generated in the inverter as a result of the application of the method. Considerations on the application of the active du/dt filtering method in electric drives are presented together with experimental data in order to verify the potential of the method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Strategic development of distribution networks plays a key role in the asset management in electricity distribution companies. Owing to the capital-intensive nature of the field and longspan operations of companies, the significance of a strategy is emphasised. A well-devised strategy combines awareness of challenges posed by the operating environment and the future targets of the distribution company. Economic regulation, ageing infrastructure, scarcity of resources and tightening supply requirements with challenges created by the climate change put a pressure on the strategy work. On the other hand, technology development related to network automation and underground cabling assists in answering these challenges. This dissertation aims at developing process knowledge and establishing a methodological framework by which key issues related to network development can be addressed. Moreover, the work develops tools by which the effects of changes in the operating environment on the distribution business can be analysed in the strategy work. To this end, the work discusses certain characteristics of the distribution business and describes the strategy process at a principle level. Further, the work defines the subtasks in the strategy process and presents the key elements in the strategy work and long-term network planning. The work delineates the factors having either a direct or indirect effect on strategic planning and development needs in the networks; in particular, outage costs constitute an important part of the economic regulation of the distribution business, reliability being thus a key driver in network planning. The dissertation describes the methodology and tools applied to cost and reliability analyses in the strategy work. The work focuses on determination of the techno-economic feasibility of different network development technologies; these feasibility surveys are linked to the economic regulation model of the distribution business, in particular from the viewpoint of reliability of electricity supply and allowed return. The work introduces the asset management system developed for research purposes and to support the strategy work, the calculation elements of the system and initial data used in the network analysis. The key elements of this asset management system are utilised in the dissertation. Finally, the study addresses the stages of strategic decision-making and compilation of investment strategies. Further, the work illustrates implementation of strategic planning in an actual distribution company environment.