982 resultados para vertebre, anterior, wedge, fracture, FEM, LVDT, estensimetri
Resumo:
A numerical method is developed to simulate complex two-dimensional crack propagation in quasi-brittle materials considering random heterogeneous fracture properties. Potential cracks are represented by pre-inserted cohesive elements with tension and shear softening constitutive laws modelled by spatially varying Weibull random fields. Monte Carlo simulations of a concrete specimen under uni-axial tension were carried out with extensive investigation of the effects of important numerical algorithms and material properties on numerical efficiency and stability, crack propagation processes and load-carrying capacities. It was found that the homogeneous model led to incorrect crack patterns and load–displacement curves with strong mesh-dependence, whereas the heterogeneous model predicted realistic, complicated fracture processes and load-carrying capacity of little mesh-dependence. Increasing the variance of the tensile strength random fields with increased heterogeneity led to reduction in the mean peak load and increase in the standard deviation. The developed method provides a simple but effective tool for assessment of structural reliability and calculation of characteristic material strength for structural design.
Resumo:
Purpose. To determine the agreement between observers in estimating the configuration of the human anterior chamber angle (ACA) using ultrasound biomicroscopy (UBM). Methods. Two masked clinicians used UBM images to estimate, in 41 eyes, the configuration of the ACA, especially (1) the position of contact between the peripheral iris and the inside of the eye wall, (2) the angularity of the approach to the ACA, and (3) the curvature of the peripheral iris. Agreement between observers was evaluated by the kappa statistic. Results. Inter-observer agreement in assessing the iris insertion (kappa = 0.79), angular width (Kappa = 0.95), and the peripheral iris curvature (kappa = 0.84) was high. Conclusions. The agreement between observers in evaluating the anterior chamber angle configuration by UBM was excellent.
Resumo:
Purpose: A peripheral iridotomy (PI) is the treatment of choice for pupillary block. In this study we investigated the effect of enlarging the size of a small PI on the anterior chamber angle in patients with angle closure using ultrasound biomicroscopy (UBM). Patients and Methods: Patients who had been treated with laser peripheral iridotomy for angle closure and were identified to have a small patent PI (<100 µm) with still appositionally closed anterior chamber angle were selected prospectively. The anterior chamber angle was assessed using UBM. The angle opening distance 500 µm from the scleral spur (AOD500) as well as the anterior and posterior chamber depth (ACD and PCD) 1000 µm from the scleral spur was measured. In addition, the ACD/PCD ratio was calculated. Afterwards, the PI was enlarged using an Nd: YAG laser and the UBM measurements were repeated as described above. Results: Six eyes of six patients were examined. After the enlargement of the PI the average AOD500 increased from 109 µm (±36) to 147 µm (±40) (p
Resumo:
Background - The study of corneal endothelium, by specular microscopy, in patients with anterior uveitis has largely been restricted to observations on the endothelial cells. In this prospective study 'keratic precipitates' (KP) in different types of uveitis were examined in different stages of the disease process and the endothelial changes occurring in the vicinity of the KP were evaluated in comparison with the endothelium of the uninvolved eye. Methods - 13 patients with active unilateral uveitis were recruited. The mean age was 42.9 years (range 20-76 years). A Tomey-1100 contact wide field specular (x10) microscope was used to capture endothelial images and KP until the resolution of uveitis. Data regarding type of uveitis, number, size, and nature of KP were recorded. Automated morphometric analysis was done for cell size, cell density and coefficient of variation, and statistical comparisons of cell size and cell density were made (Student's t test) between the endothelium in the vicinity of fresh and resolving KP, fresh KP and normal endothelium, and resolving KP and normal endothelium. Results - On specular microscopy, fresh KP were seen as dense, white glistening deposits occupying 5-10 endothelial cells in diameter and fine KP were widely distributed and were one or two endothelial cells in diameter. The KP in Posner-Schlossman syndrome had a distinct and different morphology. With clinical remission of uveitis, the KP were observed to undergo characteristic morphological changes and old KP demonstrated a large, dark halo surrounding a central white deposit and occasionally a dark shadow or a 'lacuna' replaced the site of the original KP. Endothelial blebs were noted as dark shadows or defects in the endothelial mosaic in patients with recurrent uveitis. There was significant statistical difference in the mean cell size and cell density of endothelial cells in the vicinity of fresh KP compared with normal endothelium of the opposite eye. Conclusion - This study elucidated the different specular microscopic features of KP in anterior uveitis. Distinct morphological features of large and fine KP were noted. These features underwent dramatic changes on resolution of uveitis. The endothelium was abnormal in the vicinity of KP, which returned to near normal values on resolution of uveitis.
Resumo:
Purpose: To determine the intra- and interobserver agreement in assessing the configuration of the human anterior chamber angle using ultrasound biomicroscopy (UBM). Methods: Two masked clinicians used ubm images to estimate, in 41 eyes, (a) the position of contact between the peripheral iris and the inside of the eye wall, (b) the angular size of the anterior chamber angle (ACA), and (c) the curvature of the peripheral iris. Both observers, masked to the previous results, examined the same images in a second session. Agreement was evaluated using the unweighted ? statistic. Results: Intraobserver agreement in assessing the iris insertion, angular width, and the iris curvature was high (range of ? values, 0.83-0.92). Interobserver agreement in evaluating the level of iris insertion (? = 0.79), the angular width (? = 0.95), and the iris curvature (? = 0.84) was also high. Conclusion: The agreement within the same observer and between observers in evaluating the ACA configuration by UBM was excellent.
Resumo:
This report describes the implantation of a standard posterior chamber intraocular lens (IOL) in a patient with bilateral cataract and anterior megalophthalmos. After extracapsular cataract extraction, the IOL was sutured to the posterior surface of the iris and anterior capsule. Different types of IOLs were used in each eye, and the surgical technique was adapted to the characteristics of the IOL. No complications were noted. Visual rehabilitation was successful. Extracapsular cataract extraction with a posterior chamber IOL sutured to the posterior surface of the iris and anterior capsule is a useful option in patients with anterior megalophthalmos and cataract.
Resumo:
A novel approach for introducing aligned multi-walled carbon nanotubes (MWCNTs) in a carbon-fibre composite pre-impregnated (prepreg) laminate, to improve the through-thickness fracture toughness, is presented. Carbon nanotube (CNT) 'forests' were grown on a silicon substrate with a thermal oxide layer, using a chemical vapour deposition (CVD) process. The forests were then transferred to a pre-cured laminate interface, using a combination of pressure and heat, while maintaining through-thickness CNT alignment. Standard Mode I and four-point bend end-notched flexure Mode II tests were undertaken on a set of specimens and compared with pristine specimens. Mode I fracture toughness for T700/M21 laminates was improved by an average of 31% while for T700/SE84LV specimens, an improvement of 61% was observed. Only T700/M21 specimens were tested in Mode II which yielded an average fracture toughness improvement of 161%. Scanning Electron Microscopy (SEM) showed good wetting of the CNT forest as well as evidence of penetration of the forest into the adjacent plies. © 2013 Elsevier Ltd.