892 resultados para surface thermal lens


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of stainless steel, glass, zirconium and titanium enamel surfaces on the thermal and photooxidative toughening mechanism of dehydrated castor oil films deposited on these surfaces was investigated using different analytical and spectroscopic methods. The conjugated and non-conjugated double bonds were identified and quantified using both Raman spectroscopy and 1D and 2D NMR spectroscopy. The disappearance of the double bonds in thermally oxidised oil-on-surface films was shown to be concomitant with the formation of hydroperoxides (determined by iodometric titration). The type of the surface had a major effect on the rate of thermal oxidation of the oil, but all of the surfaces examined had resulted in a significantly higher rate of oxidation compared to that of the neat oil. The highest effect was exhibited by the stainless steel surface followed by zirconium enamel, titanium enamel and glass. The rate of thermal oxidation of the oil-on-steel surface (at 100 °C, based on peroxide values) was more than five times faster than that of oil-on-glass and more than 21 times faster than the neat oil when compared under similar thermal oxidative conditions. The rate of photooxidation at 60 °C of oil-on-steel films was found to be about one and half times faster than their rate of thermal oxidation at the same temperature. Results from absorbance reflectance infrared microscopy with line scans taken across the depth of thermally oxidised oil-on-steel films suggest that the thermal oxidative toughening mechanism of the oil occurs by two different reaction pathways with the film outermost layers, i.e. furthest away from the steel surface, oxidising through a traditional free radical oxidation process involving the formation of various oxygenated products formed from the decomposition of allylic hydroperoxides, whereas, in the deeper layers closer to the steel surface, crosslinking reactions predominate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Soft contact lenses for continuous wear require the use of cleaning regimes which utilise hydrogen peroxide systems or multipurpose cleaning solutions (MPS). The compositions of MPS are becoming increasingly complex and often include disinfectants, cleaning agents, preservatives, wetting agents, demulcents, chelating and buffering agents. Recent research on solution–lens interactions has focused on specific ocular parameters such as corneal staining. However the effect of a solution on the lens, particularly silicone hydrogel lenses, itself has received less attention. The purpose of this work was to establish and understand the effects that care solutions have on selected bulk and surface material properties. Methods: Selected bulk and surface properties of each material (etafilcon A, vifilcon A, balafilcon A, senofilcon A, lotrafilcon A and lotrafilcon B, galyfilcon A) were measured after a 24 h soak in a variety of care solutions. Additionally the lenses were soaked for 24 h in hyperosmolar (680 mOsm L-1) and hyposmolar (170 mOsm L-1) PBS. A bulk property parameter the total diameter (TD) was measured using an Optimec contact lens analyser. The surface property related CoF of soaked lenses was measured on a nano-tribometer with conditions of load 30 mN, at a distance of 20 mm and speed 30 mm/min. Results: In terms of bulk properties, change is related to the EWC of the lens, the higher the EWC of the lens the greater the TD changes. Silicone hydrogel lenses have EWCs of <47% and little or no TD changes were observed; lotrafilcon A exhibited no change irrespective of the cleaning solution. Conventional contact lenses have higher EWCs (58% for etafilcon A and 55% for vifilcon A) and the TD was seen to change to a greater extent, for example the etafilcon A material in ReNu MPS had an increase to 14.45± 0.07 mm from the cited 14.2 mm. Other lenses increased or decreased in TD depending on the solution used. The osmolarity of the solution although important is not the only factor governing change in the TD, for example soaking senofilcon A in hyperosmolar PBS (680 mOsm L-1) for 24 h increased the TD of the lens (+0.25 ± 0.07 mm), however when the same lens type was soaked for 24 h in a MPS with a lower osmolarity there was a similar effect. Biotribology measurements demonstrated that some solution–lens combinations can reduce the CoF by 55%, when compared with biotribology with the native packing solution. An increase in the CoF was observed for other solution–lens combinations. Conclusions: There is a dramatic difference in bulk and surface performance of specific lens materials with particular care solutions. Individual components of the care solutions have effects on the bulk and surface properties of contact lenses. The affects are not as great with the silicone hydrogel as compared with conventional hydrogels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the initial launch of silicone hydrogel lenses, there has been a considerable broadening in the range of available commercial material properties. The very mobile silicon–oxygen bonds convey distinctive surface and mechanical properties on silicone hydrogels, in which advantages of enhanced oxygen permeability, reduced protein deposition, and modest frictional interaction are balanced by increased lipid and elastic response. There are now some 15 silicone hydrogel material variants available to practitioners; arguably, the changes that have taken place have been strongly influenced by feedback based on clinical experience. Water content is one of the most influential properties, and the decade has seen a progressive rise from lotrafilcon-A (24%) to efrofilcon-A (74%). Moduli have decreased over the same period from 1.4 to 0.3 MPa, but not solely as a result of changes in water content. Surface properties do not correlate directly with water content, and ingenious approaches have been used to achieve desirable improvements (e.g., greater lubricity and lower contact angle hysteresis). This is demonstrated by comparing the hysteresis value of the earliest (lotrafilcon-A, >40°) and most recent (delefilcon-A, <10°) coated silicone hydrogels. Although wettability is important, it is not of itself a good predictor of ocular response because this involves a much wider range of physicochemical and biochemical factors. The interference of the lens with ocular dynamics is complex leading separately to tissue–material interactions involving anterior and posterior lens surfaces. The biochemical consequences of these interactions may hold the key to a greater understanding of ocular incompatibility and end of day discomfort.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Internally heated fluids are found across the nuclear fuel cycle. In certain situations the motion of the fluid is driven by the decay heat (i.e. corium melt pools in severe accidents, the shutdown of liquid metal reactors, molten salt and the passive control of light water reactors) as well as normal operation (i.e. intermediate waste storage and generation IV reactor designs). This can in the long-term affect reactor vessel integrity or lead to localized hot spots and accumulation of solid wastes that may prompt local increases in activity. Two approaches to the modeling of internally heated convection are presented here. These are based on numerical analysis using codes developed in-house and simulations using widely available computational fluid dynamics solvers. Open and closed fluid layers at around the transition between conduction and convection of various aspect ratios are considered. We determine optimum domain aspect ratio (1:7:7 up to 1:24:24 for open systems and 5:5:1, 1:10:10 and 1:20:20 for closed systems), mesh resolutions and turbulence models required to accurately and efficiently capture the convection structures that evolve when perturbing the conductive state of the fluid layer. Note that the open and closed fluid layers we study here are bounded by a conducting surface over an insulating surface. Conclusions will be drawn on the influence of the periodic boundary conditions on the flow patterns observed. We have also examined the stability of the nonlinear solutions that we found with the aim of identifying the bifurcation sequence of these solutions en route to turbulence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Approximately half of current contact lens wearers suffer from dryness and discomfort, particularly towards the end of the day. Contact lens practitioners have a number of dry eye tests available to help them to predict which of their patients may be at risk of contact lens drop out and advise them accordingly. This thesis set out to rationalize them to see if any are of more diagnostic significance than others. This doctorate has found: (1) The Keratograph, a device which permits an automated, examiner independent technique for measuring non invasive tear break up time (NITBUT) measured NITBUT consistently shorter than measurements recorded with the Tearscope. When measuring central corneal curvature the spherical equivalent power of the cornea was measured as being significantly flatter than with a validated automated keratometer. (2) Non-invasive and invasive tear break-up times significantly correlated to each other, but not the other tear metrics. Symptomology, assessed using the OSDI questionnaire, correlated more with those tests indicating possible damage to the ocular surface (including LWE, LIPCOF and conjunctival staining) than with tests of either tear volume or stability. Cluster analysis showed some statistically significant groups of patients with different sign and symptom profiles. The largest cluster demonstrated poor tear quality with both non-invasive and invasive tests, low tear volume and more symptoms. (3) Care should be taken in fitting patients new to contact lenses if they have a NITBUT less than 10s or an OSDI comfort rating greater than 4.2 as they are more likely to drop-out within the first 6 months. Cluster analysis was not found to be beneficial in predicting which patients will succeed with lenses and which will not. A combination of the OSDI questionnaire and a NITBUT measurement was most useful both in diagnosing dry eye and in predicting contact lens drop out.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

What is meant by the term ‘specialist contact lens fitting’? Or put another way, what would be considered non-specialist contact lens fitting? Is there such a thing as routine contact lens fitting? Soft or silicone hydrogel fitting for daily wear would probably be considered as routine contact lens fitting, but would extended or flexible wear remain in the same category or would they be considered a specialist fit? Different eras will classify different products as being ‘specialist’. Certainly twenty years ago soft toric contact lenses were considered as being speciality lenses but today would be thought of as routine lenses. Conversely, gas permeable lenses were thought of as mainstream twenty years ago but now are considered as speciality lenses. Although this would not be the same globally, as in some countries (such as Netherlands, France and Japan) gas permeable lens fitting remains popular and is not on the decline as in other countries (Canada, Australia and Sweden) [1]. Bandage soft lenses applied after surface laser refractive procedures would be considered as therapeutic lenses but in reality they are just plano thin hydrogel lenses worn constantly for 3–4 days to allow the underlying epithelium to convalesce and are then removed [2]. Some patients find that wearing hydrogel lenses during periods when they suffer from seasonal allergies actually improves their ocular comfort as the contact lens acts as a barrier to the allergen [3] and [4]. Scleral lenses have long been considered speciality lenses, apart from a time when they were the only lenses available but at that time all contact lens work would have been considered speciality practice! Nowadays we see the advent of mini-scleral designs and we see large diameter gas permeable lenses too. It is possible that these lenses increase the popularity of gas permeable lenses again and they become more main stream. So it would seem that the lines between routine and speciality contact lens fitting are not clear. Whether a lens is classed a specialist fit or not would depend on the lens type, why it was fitted, where in the world the fitting was being done and even the era in which it was fitted. This begs the question as to what would be considered entry level knowledge in contact lens fitting. This may not be an issue for most BCLA members or CLAE readers but certainly would be for bodies such as the College of Optometrists (UK) or the Association of British Dispensing Opticians when they are planning the final registration examinations for budding practitioners or when planning the level of higher level qualifications such as College Certificates or Diplomas. Similarly for training institutions when they are planning their course content. This becomes even trickier when trying to devise a qualification that spans across many countries, like the European Diploma in Optometry and Optics. How do we know if the training and examination level is correct? One way would be to analyse things when they go wrong and if patterns of malpractice are seen then maybe that could be used as an indicator to more training being needed. There were 162 Fitness to Practice Hearing at the General Optical Council between 2001 and 2010. Forty-seven of these were clinically related case, 39 fraud related, and 76 others. Of the clinical ones only 3 were contact lens related. So it would appear that as whole, in the profession, contact lens clinical skills are not being questioned too often (although it seems a few of us can’t keep our hands out the cookie jar!).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Biochemical changes brought about by the influence of the contact lens on the tear film are conveniently split into two categories. Firstly, the lens can remove or reduce the levels of specific components in the tear film, and secondly, the lens can augment the tear film, by stimulating the influx of new components or increasing the level of existing components. The most obvious tear film components for study in this context are lipids, proteins, mucins and electrolytes. The interactions are affected by the properties of the lens, the characteristics of the individual wearer and the wear schedule. An additional complicating factor is the fact that the lens is many times thicker than the tear film and any immobilised tear components will be more extensively exposed to oxygen and UV radiation than is the case in the absence of a lens. It is arguably the lipoidal components that are most markedly affected by lens wear, since their immobilisation on the lens surface markedly increases their susceptibility to autoxidative degradation. The limited information that is available highlights the importance of subject specificity and suggests that lipid oxidation phenomena are potentially important in contributing to the 'end of day' discomfort of symptomatic contact lens patients. It is clear that tear lipids, although regarded as relatively inert for many years, are now seen as a reactive and potentially important family of compounds in the search for understanding of contact lens-induced discomfort. The influence of the lens on tear proteins shows the greatest range of complexity. Deposition and denaturation can stimulate immune response, lower molecular weight proteins can be extensively absorbed into the lens matrix and the lens can stimulate cascade or upregulation processes leading either to the generation of additional proteins and peptides or an increase in concentration of existing components. Added to this is the stimulating influence of the lens on vascular leakage leading to the influx of plasma proteins such as albumin. The evidence from studies of mucin expression in tears is not consistent and conclusive. This is in part because sample sources, lens materials and methods of analysis vary considerably, and in some cases the study population numbers are low. Expression levels show mucin and material specificity but clear patterns of behaviour are elusive. The electrolyte composition of tears is significantly different from that of other body fluids. Sodium and potassium dominate but potassium ion concentrations in tears are much higher than in serum levels. Calcium and magnesium concentrations in tears are lower than in serum but closer to interstitial fluids. The contact lens provides the potential for increased osmolarity through enhanced evaporation and differential electrolyte concentrations between the anterior and posterior tear films. Since the changes in ocular biochemistry consequent upon contact lens wear are known to be subject-dependent - as indeed is wearer response to the lens - pre-characterisation of individual participant tear chemistry in clinical studies would enhance understanding of these complex effects. © 2013 Elsevier Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE. To examine the relation between ocular surface temperature (OST) assessed by dynamic thermal imaging and physical parameters of the anterior eye in normal subjects. METHODS. Dynamic ocular thermography (ThermoTracer 7102MX) was used to record body temperature and continuous ocular surface temperature for 8 s after a blink in the right eyes of 25 subjects. Corneal thickness, corneal curvature, and anterior chamber depth (ACD) were assessed using Orbscan II; noninvasive tear break-up time (NIBUT) was assessed using the tearscope; slit lamp photography was used to record tear meniscus height (TMH) and objective bulbar redness. RESULTS. Initial OST after a blink was significantly correlated only with body temperature (r = 0.80, p < 0.0005), NIBUT (r = -0.68, p < 0.005) and corneal curvature (r = -0.40, p = 0.05). A regression model containing all the variables accounted for 70% (p = 0.002) of the variance in OST, of which NIBUT (29%, p = 0.004), and body temperature (18%, p = 0.005) contributed significantly. CONCLUSIONS. The results support previous theoretical models that OST radiation is principally related to the tear film; and demonstrate that it is less related to other characteristics such as corneal thickness, corneal curvature, and anterior chamber depth. © 2007 American Academy of Optometry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To show that the limited quality of surfaces produced by one model of excimer laser systems can degrade visual performance with a polymethylmethacrylate (PMMA) model. METHODS: A range of lenses of different powers was ablated in PMMA sheets using five DOS-based Nidek EC-5000 laser systems (Nidek Technologies, Gamagori, Japan) from different clinics. Surface quality was objectively assessed using profilometry. Contrast sensitivity and visual acuity were measured through the lenses when their powers were neutralized with suitable spectacle trial lenses. RESULTS: Average surface roughness was found to increase with lens power, roughness values being higher for negative lenses than for positive lenses. Losses in visual contrast sensitivity and acuity measured in two subjects were found to follow a similar pattern. Findings are similar to those previously published with other excimer laser systems. CONCLUSIONS: Levels of surface roughness produced by some laser systems may be sufficient to degrade visual performance under some circumstances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The selective oxidation of crotyl alcohol to crotonaldehyde over ultrathin Au overlayers on Pd(1 1 1) and Au/Pd(1 1 1) surface alloys has been investigated by time-resolved X-ray photoelectron spectroscopy (XPS) and mass spectrometry. Pure gold is catalytically inert towards crotyl alcohol which undergoes reversible adsorption. In contrast, thermal processing of a 3.9 monolayer (ML) gold overlayer allows access to a range of AuPd surface alloy compositions, which are extremely selective towards crotonaldehyde production, and greatly reduce the extent of hydrocarbon decomposition and eventual carbon laydown compared with base Pd(1 1 1). XPS and CO titrations suggest that palladium-rich surface alloys offer the optimal balance between alcohol oxidative dehydrogenation activity while minimising competitive decomposition pathways, and that Pd monomers are not the active surface ensemble for such selox chemistry over AuPd alloys. Crown Copyright © 2008.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we investigated the effect of hydrogen termination on the electrical properties and impedance spectra of detonation nanodiamond. The impedance spectra revealed that the hydrogen-termination process increases the electrical conductivity by four orders of magnitude at room temperature. An equivalent circuit has been proposed to correlate with the conduction mechanism. Arrhenius plot showed that there were two different activation energy levels located at 0.089 eV and 0.63 eV between 50 °C and 400 °C. The possible physical mechanism corresponding to these activation energy levels has been discussed. Hydrogen-terminated detonation nanodiamond has been further annealed at different temperatures prior to FTIR and XPS measurements in order to understand their thermal stability. The results demonstrated that the surface oxidization occurred between 100 °C and 150 °C. However, the C-H bonds could partially survive when the temperature reaches 400 °C in air. © 2013 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aging responses of 2124 Al-SiC p metal matrix composite (MMC) and unreinforced matrix alloy are studied and related to variations in tensile properties. The MMC is aged from Wo starting conditions: (i) stretched and naturally aged and (ii) re-solution treated. Accelerated aging occurs in both MMC conditions compared with unreinforced alloy. Tensile strengths and elastic moduli are improved in the MMC compared with the alloy, but ductility is reduced. Stretched MMC exhibits higher strength but lower ductility and modulus than re-solutioned MMC. The re-solutioned MMC fails by microvoid coalescence in low aging conditions, and by void nucleation and shear in high aging conditions. Failure of the stretched MMC initiates at the surface at specimen shoulders, illustrating the increased notch sensitivity of this condition, and propagates via a zigzag shear fracture mode. Zigzag facet size increases on gross aging. Particle fracture occurs during tensile failure, but also before testing as a result of the manufacturing process. © 1995 The Institute of Materials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate lenses produced by excimer laser ablation of poly(methyl methacrylate) (PMMA) plates. Setting: University research laboratory. Methods: Two Nidek EC-5000 scanning-slit excimer laser systems were used to ablate plane-parallel plates of PMMA. The ablated lenses were examined by focimetry, interferometry, and mechanical surface profiling. Results: The spherical optical powers of the lenses matched the expected values, but the cylindrical powers were generally lower than intended. Interferometry revealed marked irregularity in the surface of negative corrections, which often had a positive “island” at their center. Positive corrections were generally smoother. These findings were supported by the results of mechanical profiling. Contrast sensitivity measurements carried out when observing through ablated lenses whose power had been neutralized with a suitable spectacle lens of opposite sign confirmed that the surface irregularities of the ablated lenses markedly reduced contrast sensitivity over a range of spatial frequencies. Conclusion: Improvements in beam delivery systems seem desirable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lipids play a vital role in the body at many interfaces. Examples include the lubrication of articulating joints by synovial fluid, the coating of the lung by pulmonary surfactant and the functions of the tear film in the protection of the anterior eye. The role of the lipids is similar at each site - acting as boundary lubricants and reducing surface and interfacial tension. This review focuses on how and why contact lens wear can disrupt the normal function of lipids within the tear film and explains how the otherwise advantageous presence and function of tear lipids can become disadvantageous, causing problems for the wearer. Because the contact lens is some ten times thicker than the tear film, lipids deposited on the anterior surface become immobilised, reducing lipid turnover and thus leading to prolonged exposure to oxygen and light with consequent generation of degradation products. These degraded lipids reduce lens wettability and have additionally been linked to problems of contact lens discomfort and intolerance. Lipid problems are influenced by the thickness of the lens, the material, surface modification, mode of wear and ultimately the subject. The most influential of these variables is frequently the subject. © 2012.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hierarchical nanowires (HNWs) exhibit unique properties and have wide applications, while often suffering from imperfect structure. Herein, we report a facile strategy toward ultrathin CdS HNWs with monocrystal structure, where a continuous-wave (CW) Nd:YAG laser is employed to irradiate an oleic acid (OA) solution containing precursors and a light absorber. The high heating rate and large temperature gradient generated by the CW laser lead to the rapid formation of tiny zinc-blende CdS nanocrystals which then line up into nanowires with the help of OA molecules. Next, the nanowires experience a phase transformation from zinc-blende to wurtzite structure, and the transformation-induced stress creates terraces on their surface, which promotes the growth of side branches and eventually results in monocrystal HNWs with an ultrathin diameter of 24 nm. The one-step synthesis of HNWs is conducted in air and completes in just 40 s, thus being very simple and rapid. The prepared CdS HNWs display photocatalytic performance superior to their nanoparticle counterparts, thus showing promise for catalytic applications in the future.