912 resultados para side illumination fluorescence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Langmuir films have been fabricated from poly[(2-methoxy-5-n-hexyloxy)-p-phenylenevinylene] (OC1OC6-PPV). The stability and the area per monomer for condensed films indicate the formation of true monolayers with a very small extent of aggregation, which is unusual for polymer films. This is attributed to the linearity of the alkyl side chain. The Y-type Langmuir-Blodgett (LB) films produced from Langmuir films of OC1OC6-PPV have distinctive features compared to those of cast films, probably due to the organization in the LB films whereas the molecules are randomly oriented in cast films. Infrared absorption spectra recorded for both transmission and reflection modes indicate that OC1OC6-PPV molecules are anchored to the substrate by the lateral groups. This is confirmed by the Raman spectrum, in which a distortion of the vinylene group was observed, and by surface enhanced fluorescence (SEF) on an LB monolayer deposited onto Ag nanoparticles. The more homogeneous nature of the LB films in comparison with the case of cast films was demonstrated by optical microscopy and fluorescence measurements where the emission spectra were essentially the same for different regions of an LB film but showed dispersion in cast films. The LB films also displayed reversible photoconductivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The capacitor-commutated converter (CCC) has frequently been used in the conception of HVDC systems connected to busbars with low short circuit level. This alternative arrangement, in substitution to the conventional ones, guarantees less sensitive operational conditions to problems related with the commutation failure in the inverters besides supplying part of the reactive energy to be compensated. Studies related with its performance in steady and transient states have been presented in several works, however its behavior as harmonic source is still little explored. This work presents preliminary studies focusing the generation of characteristic harmonics by this type of converter. Subjects related with the amplification of the harmonic magnitudes are investigated and compared considering similar arrangements of conventional static converters (LCC) and CCC schemes. It is also analyzed the harmonic generation on the dc side of the installation and its influence on the ac side harmonics. The results are obtained from simulations in the time domain in PSpice environment and they clearly illustrate the operational differences between the L CC and the CCC schemes with regard to characteristic harmonic generation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Comparar a reinervação muscular com enxerto de nervo em um e dois tempos operatórios, utilizando a neurorrafia término-lateral (NTL) sem lesão do nervo doador. MÉTODOS: Vinte ratos foram distribuídos em quatro grupos. O grupo 1 (G1), um estágio, recebeu o enxerto que foi suturado ao nervo tibial (NT), por meio de NTL, e seu coto livre foi suturado por NTL ao coto distal do nervo peroneal (NP), seccionado a um centímetro do NT, na mesma cirurgia. O grupo 2 (G2), dois estágios, recebeu o enxerto de nervo na primeira cirurgia, como já descrito. Dois meses depois, na segunda cirurgia, o NP foi seccionado e seu coto distal ligado ao coto distal do enxerto como em G1. O grupo controle de normalidade (Gn) recebeu o enxerto da mesma forma, apenas. E o grupo controle de denervação (Gd), além de receber o enxerto, teve o NP seccionado e seus cotos sepultados na musculatura adjacente, com a finalidade de denervar o músculo tibial cranial (MTC), alvo deste estudo. Os parâmetros utilizados para avaliar a reinervação do MTC foram massa muscular, diâmetro mínimo da fibra muscular e área. RESULTADOS: O grupo G2 apresentou superioridade (p<0,0001) em relação ao G1 na massa do MTC, no diâmetro mínimo e na área das fibras musculares. Na comparação entre os quatro grupos, estes mesmos parâmetros tiveram sua expressão máxima em Gn e mínima em Gd, como era esperado. CONCLUSÃO: A reinervação muscular em dois estágios apresenta melhor resultado quando comparada à técnica em um tempo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Comparar dois novos métodos com o método tradicional da neurorrafia término-lateral. MÉTODOS: Os ratos foram separados em quatro grupos. No grupo A-E o nervo peroneal foi seccionado e o coto distal foi suturado à lateral do nervo tibial com dois pontos de nylon 10-0. No grupo A-D duas abas de epi-perineuro abraçaram o nervo doador. No grupo B-D foi realizada sutura com um único ponto abraçando o nervo doador. O grupo B-E foi o controle. Após seis meses foram observados massa do músculo tibial cranial e morfometria do coto distal do nervo peroneal. RESULTADOS: Foi encontrada menor massa muscular nos grupos A-D, A-E e B-D quando comparados com o grupo B-E (p<0.0001) e mesma massa quando comparados entre si (p>0,05). Os grupos A-D, A-E e B-D apresentaram menor número de fibras nervosas quando comparados ao grupo B-E (p=0,0155; p=0,016; p=0,0021) e mesmo número quando comparados entre si. CONCLUSÃO: Os três tipos de neurorrafia não apresentaram diferenças relacionadas à massa muscular e número de fibras nervosas sugerindo que a sutura abraçante com apenas um ponto apresente grande potencial em áreas cirúrgicas mais profundas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare visual inspection (VI), radiographic examination (RX) and the laser fluorescence device DIAGNOdent (L), as well as their combinations in vitro regarding treatment decisions for occlusal surfaces. Methods: 72 extracted human permanent teeth (molars and premolars) were used. Treatment decisions were recorded by three calibrated examiners, and the options available were fissure sealant and conservative restoration. For validation of treatment decisions, the teeth were sectioned and examined in a stereomicroscope. Thereafter, dental slices were scanned and the images were edited to facilitate classification of existing carious lesions. Intra and inter-examiner reproducibility for the determination of treatment plans were calculated using Cohen's kappa test (95%-CI). Sensitivity, specificity, positive and negative predictive values, and the area under the ROC curve were also calculated. Results: VI and L provided on average the greatest intra- and inter-examiner reproducibility, respectively. Although the combination of diagnostic methods may decrease both intra- and inter examiners reproducibility, combination of VI, L and RX resulted in the greatest sensitivity, being statistically superior to RX and L. There was more inter-examiner agreement for the option of restorative treatment, while the use of sealants as a treatment option yielded the lowest values. Negative predictive values were numerically inferior to positive predictive values, indicating that the examiners preferred not to restore a carious tooth than to proceed operatively in an intact tooth. The combination of the three methods studied showed the best results in determining treatment plans for occlusal surfaces, when compared to the other types of exams. on the other hand, radiographic examination and laser fluorescence were less efficient when used alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to evaluate laser fluorescence (LF) for monitoring the initial stage of subsurface de- and remineralization (<150 mu m depth). Ninety-six sound blocks of bovine enamel, selected according to surface hardness (SH) and LF were used in two experimental studies, in vitro and in situ. In vitro, blocks were exposed to a demineralizing solution, then remineralized by pH cycling for 6 days. In situ, 10 volunteers wore acrylic palatal appliances, each containing 4 dental enamel blocks that were demineralized for 14 days by exposure to 20% sucrose solution. Following this treatment, blocks were submitted to remineralization for 1 week with fluoride dentifrice (1,100 mu g F/g). In both experiments, SH and LH were measured after demineralization and after remineralization. Further, enamel blocks were selected after the demineralization/remineralization steps for measurement of cross-sectional hardness and integrated loss of subsurface hardness (Delta KHN). SH and Delta KHN showed significant differences among the phases in each study. LF values for sound, demineralized and remineralized enamel were: 5.2 +/- 1.1, 8.1 +/- 1.2 and 5.6 +/- 0.8, respectively, in the in vitro study, and 5.3 +/- 0.3, 16.5 +/- 4.7 and 6.5 +/- 2.5, respectively, in the in situ study, values for demineralized enamel being significantly higher than for sound and remineralized enamel in both studies. However, LF was correlated with Delta KHN only in situ. LF was capable of monitoring de- and remineralization in early lesions in situ, when bacteria are presumably present in the caries lesion body, but is not correlated with mineral changes in bacteria-free systems. Copyright (C) 2009 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the in situ and in vitro performances of a laser fluorescence (LF) device (DIAGNOdent 2095) with visual inspection for the detection of occlusal caries in permanent teeth. Sixty-four sites were selected, and visual inspection and LF assessments were carried out, in vitro, three times by two independent examiners, with a 1-week interval between evaluations. Afterwards, the occlusal surfaces were mounted on the palatal portion of removable acrylic orthodontic appliances and placed in six volunteers. Assessments were repeated and validated by histological analysis of the tooth sections under a stereomicroscope. For both examiners, the highest intra-examiner values were observed for the visual inspection when in vitro and in situ evaluations were compared. The inter-examiner reproducibility varied from 0.61 to 0.64, except for the in vitro assessment using LF, which presented a lower value (0.43). The methods showed high specificity at the D(1) threshold (considering enamel and dentin caries as disease). In vitro evaluations showed the highest values of sensitivity for both methods when compared to the in situ evaluations at D(1) and D(2) (considering only dentinal caries as the disease) thresholds. For both methods, the results of sensitivity (at D(1) and D(2)) and accuracy (at D(1)) showed significant differences between in vitro and in situ conditions. However, the sensitivity (at D(1) and D(2)), specificity and accuracy (both at D(1)) of the methods were not significantly different when the same condition was considered. It can be concluded that visual inspection and LF showed better performance in vitro than in situ.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this in vivo study was to evaluate the performance of laser fluorescence (LF) comparing different cut-off limits for occlusal caries detection. One hundred and thirty first permanent molars were selected. Visual examination and LF assessments were performed independently. The extent of caries was assessed after operative intervention. New cut-off limits were established and compared with those proposed by the manufacturer and by Lussi et al. (Eur J Oral Sci 109:14-19, 2001). Similar sensitivity and higher specificity was found at D(2) (considering as disease only dentin caries) when the LF cut-off limits proposed by Lussi et al. and the new one were compared. At the D(3) threshold (considering as disease only deep dentin caries), no statistically significant difference among the cut-off limits for sensitivity was found. However, the new cut-off limits showed higher specificity. The LF device provided good ability to detect dentin caries lesions. Furthermore, the new cut-off limits and the values proposed by Lussi et al. could be suggested for the in vivo detection of occlusal caries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this in vitro study was to evaluate the influence of pit and fissure sealants on fluorescence readings using lasers. We selected 166 permanent molars and randomly divided them into 4 groups which were each treated with a different sealant (a commercially available clear sealant, 2 opaque sealants and an experimental nanofilled clear sealant). The teeth were independently measured twice by 2 experienced dentists using conventional laser fluorescence (LF) and a laser fluorescence pen device (LFpen), before and after sealing, and again after thermocycling to simulate the thermal stressing between the tooth and the dental materials. Friedman test showed no statistically significant changes using LF and LFpen for the commercial clear sealant group, although values tended to increase after sealing. However, the values increased significantly after thermocycling. There was a statistically significant decrease in fluorescence after application of opaque sealants. After application of the experimental nanofilled clear sealant, LF values increased only after thermocycling, whereas the LFpen values increased after sealing and after thermocycling as well. The intraclass correlation coefficient ranged from 0.87 to 0.96 for interexaminer and 0.82 to 0.94 for intraexaminer reproducibility. It was shown that pit and fissure sealants influence LF and LFpen readings, with the values increasing or decreasing according to the material used. In conclusion, both laser fluorescence devices could be useful as an adjunct to detect occlusal caries under unfilled clear sealants. Nevertheless, surfaces sealed with clear nanofilled material could be assessed using only the LF device. Copyright (C) 2008 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the performance of fluorescence-based methods, radiographic examination, and International Caries Detection and Assessment System (ICDAS) II on occlusal surfaces. One hundred and nineteen permanent human molars were assessed twice by 2 experienced dentists using the laser fluorescence (LF and LFpen) and fluorescence camera (FC) devices, ICDAS II and bitewing radiographs (BW). After measuring, the teeth were histologically prepared and assessed for caries extension. The sensitivities for dentine caries detection were 0.86 (FC), 0.78 (LFpen), 0.73 (ICDAS II), 0.51 (LF) and 0.34 (BW). The specificities were 0.97 (BW), 0.89 (LF), 0.65 (ICDAS II), 0.63 (FC) and 0.56 (LFpen). BW presented the highest values of likelihood ratio (LR)+ (12.47) and LR- (0.68). Rank correlations with histology were 0.53 (LF), 0.52 (LFpen), 0.41 (FC), 0.59 (ICDAS II) and 0.57 (BW). The area under the ROC curve varied from 0.72 to 0.83. Inter- and intraexaminer intraclass correlation values were respectively 0.90 and 0.85 (LF), 0.93 and 0.87 (LFpen) and 0.85 and 0.76 (FC). The ICDAS II kappa values were 0.51 (interexaminer) and 0.61 (intraexaminer). The BW kappa values were 0.50 (interexaminer) and 0.62 (intraexaminer). The Bland and Altman limits of agreement were 46.0 and 38.2 (LF), 55.6 and 40.0 (LFpen) and 1.12 and 0.80 (FC), for intra- and interexaminer reproducibilities. The posttest probability for dentine caries detection was high for BW and LF. In conclusion, LFpen, FC and ICDAS II presented better sensitivity and LF and BW better specificity. ICDAS II combined with BW showed the best performance and is the best combination for detecting caries on occlusal surfaces. Copyright (C) 2008 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)