929 resultados para quadrature mirror filter


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present fundamental knowledge of fluid turbulence has been established primarily from hot- and cold-wire measurements. Unfortunately, however, these measurements necessarily suffer from contamination by noise since no certain method has previously been available to optimally filter noise from the measured signals. This limitation has impeded our progress of understanding turbulence profoundly. We address this limitation by presenting a simple, fast-convergent iterative scheme to digitally filter signals optimally and find Kolmogorov scales definitely. The great efficacy of the scheme is demonstrated by its application to the instantaneous velocity measured in a turbulent jet.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This essay is presented as a Benjaminian work site. The juxtaposition of apparently distant figures in brusque and surprising relations may well cause puzzlement. But the affinities are revealing. In the whirlpools of Michael Taussig`s studies, I search for a theoretical composition in counterpoint: on one side, Victor Turner and Clifford Geertz, whose writings possibly lead us to think of a kind of paradigm of the dramatic theatre in anthropology, and, on the other, two figures on the margins of anthropology and the dramatic theatre - Walter Benjamin and Bertolt Brecht. The essay`s gravitational force is located on these margins, especially the fragmented work of Benjamin. In short, this is an essay towards a Benjaminian anthropology, organized around three allegories: (1) magic mirror; (2) shattering; and (3) flashes of light. In some ways, the journey suggests the form of an unusual rite of passage: the passage towards a passing condition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Some patients are no longer able to communicate effectively or even interact with the outside world in ways that most of us take for granted. In the most severe cases, tetraplegic or post-stroke patients are literally `locked in` their bodies, unable to exert any motor control after, for example, a spinal cord injury or a brainstem stroke, requiring alternative methods of communication and control. But we suggest that, in the near future, their brains may offer them a way out. Non-invasive electroencephalogram (EEG)-based brain-computer interfaces (BCD can be characterized by the technique used to measure brain activity and by the way that different brain signals are translated into commands that control an effector (e.g., controlling a computer cursor for word processing and accessing the internet). This review focuses on the basic concepts of EEG-based BC!, the main advances in communication, motor control restoration and the down-regulation of cortical activity, and the mirror neuron system (MNS) in the context of BCI. The latter appears to be relevant for clinical applications in the coming years, particularly for severely limited patients. Hypothetically, MNS could provide a robust way to map neural activity to behavior, representing the high-level information about goals and intentions of these patients. Non-invasive EEG-based BCIs allow brain-derived communication in patients with amyotrophic lateral sclerosis and motor control restoration in patients after spinal cord injury and stroke. Epilepsy and attention deficit and hyperactive disorder patients were able to down-regulate their cortical activity. Given the rapid progression of EEG-based BCI research over the last few years and the swift ascent of computer processing speeds and signal analysis techniques, we suggest that emerging ideas (e.g., MNS in the context of BC!) related to clinical neuro-rehabilitation of severely limited patients will generate viable clinical applications in the near future.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Entrapment of guidewires by inferior vena cava filters can occur during the blind insertion of a jugular or a subclavian central venous catheter. Recently, few case reports have been published in the radiology literature. In addition, others have described endovascular techniques aimed at removing entrapped guidewires, avoiding the possibility of vena cava rupture. Given that a temporary hemodialysis venous catheter is frequently used as a first access, the possibility of entrapping the dialysis catheter guidewire should not be neglected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: Lung hyperinflation may be assessed by computed tomography (CT). As shown for patients with emphysema, however, CT image reconstruction affects quantification of hyperinflation. We studied the impact of reconstruction parameters on hyperinflation measurements in mechanically ventilated (MV) patients. Design: Observational analysis. Setting: A University hospital-affiliated research Unit. Patients: The patients were MV patients with injured (n = 5) or normal lungs (n = 6), and spontaneously breathing patients (n = 5). Interventions: None. Measurements and results: Eight image series involving 3, 5, 7, and 10 mm slices and standard and sharp filters were reconstructed from identical CT raw data. Hyperinflated (V-hyper), normally (V-normal), poorly (V-poor), and nonaerated (V-non) volumes were calculated by densitometry as percentage of total lung volume (V-total). V-hyper obtained with the sharp filter systematically exceeded that with the standard filter showing a median (interquartile range) increment of 138 (62-272) ml corresponding to approximately 4% of V-total. In contrast, sharp filtering minimally affected the other subvolumes (V-normal, V-poor, V-non, and V-total). Decreasing slice thickness also increased V-hyper significantly. When changing from 10 to 3 mm thickness, V-hyper increased by a median value of 107 (49-252) ml in parallel with a small and inconsistent increment in V-non of 12 (7-16) ml. Conclusions: Reconstruction parameters significantly affect quantitative CT assessment of V-hyper in MV patients. Our observations suggest that sharp filters are inappropriate for this purpose. Thin slices combined with standard filters and more appropriate thresholds (e.g., -950 HU in normal lungs) might improve the detection of V-hyper. Different studies on V-hyper can only be compared if identical reconstruction parameters were used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Calcium is one of the triggers involved in ischemic neuronal death. Because hypotension is a strong predictor of outcome in traumatic brain injury (TBI), we tested the hypothesis that early fluid resuscitation blunts calcium influx in hemorrhagic shock associated to TBI. Methods: Fifteen ketamine-halothane anesthetized mongrel dogs (18.7 kg +/- 1.4 kg) underwent unilateral cryogenic brain injury. Blood was shed in 5 minutes to a target mean arterial pressure of 40 mm Hg to 45 mm Hg and maintained at these levels for 20 minutes (shed blood volume = 26 mL/kg +/- 7 mL/kg). Animals were then randomized into three groups: CT (controls, no fluid resuscitation), HS (7.5% NaCl, 4 mL/kg, in 5 minutes), and LR (lactate Ringer`s, 33 mL/kg, in 15 minutes). Twenty minutes later, a craniotomy was performed and cerebral biopsies were obtained next to the lesion (""clinical penumbra"") and from the corresponding contralateral side (""lesion`s mirror"") to determine intracellular calcium by fluorescence signals of Fura-2-loaded cells. Results: Controls remained hypotensive and in a low-flow state, whereas fluid resuscitation improved hemodynamic profile. There was a significant increase in intracellular calcium in the injured hemisphere in CT (1035 nM +/- 782 nM), compared with both HS (457 nM +/- 149 nM, p = 0.028) and LR (392 nM +/- 178 nM, p = 0.017), with no differences between HS and LR (p = 0.38). Intracellular calcium at the contralateral, uninjured hemisphere was 438 nM +/- 192 nM in CT, 510 nM +/- 196 nM in HS, and 311 nM +/- 51 nM in LR, with no significant differences between them. Conclusion: Both small volume hypertonic saline and large volume lactated Ringer`s blunts calcium influx in early stages of TBI associated to hemorrhagic shock. No fluid resuscitation strategy promotes calcium influx and further neural damage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We identify a test of quantum mechanics versus macroscopic local realism in the form of stochastic electrodynamics. The test uses the steady-state triple quadrature correlations of a parametric oscillator below threshold.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We consider the case of two cavity modes of the electromagnetic field, which are coupled via the action of a parametric amplifier. The fields are allowed to leak from the cavity and homodyne measurement is performed on one of the modes. Because of the correlations between the modes, this leads to a reduction of the variance in a quadrature of the other mode, although no measurement is performed on it directly. We discuss how this relates to the Einstein-Podolky-Rosen Gedankenexperiment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Smoking is a serious worldwide public health problem. Animal models act as a bridge between laboratory and human studies. The models applied are difficult to reproduce because of the use of different types of inhalation chambers and mainly because of the lack of continuous monitoring of smoke concentration. Objective: To develop an inhalation chamber for rats (with only the nose exposed) in which the amount of carbon monoxide (CO) can be maintained and monitored constantly. Material and methods: Male Wistar rats weighing 250 g were exposed to 50 ppm CO produced by the smoke from a filter-free cigarette. The animals were submitted to a single 2-h exposure and then sacrificed at 0, 4, 24 and 48 h. The control group was left restrained inside the small perpendicular chambers, receiving only 5 L/min of compressed air. Results: The model was able to increase HbCO levels immediately after the end of exposure (p < 0.001). with a decrease being observed from 2 h onwards when compared to the levels of the control group. Plasma cotinine increased immediately after exposure, and showed still detectable levels at 2 and 4 h (p < 0.05). Conclusion: We conclude that the presented inhalation chamber system is able to maintain a controlled CO concentration in a model in which small animals are exposed to the inhalation of cigarette smoke, permitting well-controlled studies, as well as investigations involving other toxic gases and air pollutants. (C) 2008 SEPAR. Published by Elsevier Espana, S.L. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study aimed to verify the time course of the effects of environmental levels of urban air pollution toxicity on lung arterioles. BALB/c mice (n = 56) were continuously exposed to selective chambers equipped with (filtered, F) or without (non-filtered, NF) filter devices for particles and toxic gases for 24 h/day, over 14, 21, 30 or 45 days. After exposure, we evaluated the lumen-wall relationship (an estimator of arteriolar narrowing), endothelial nitric oxide synthase (eNOS) and endothelin type A receptor (ETAr) expression in the vascular wall and inflammatory influx of the peribronchiolar area. Concentrations of fine particulate matter (PM <= 2.5 mu g/m(3)), nitrogen dioxide (NO(2)), black smoke (BS), humidity and temperature in both the environment and inside the chambers were measured daily. Filters cleared 100% of BS and 97% of PM inside the F chamber. The arteriole wall of the lungs of mice from NF chamber had an increased ETAr expression (p <= 0.042) concomitant to a decrease in the lumen/wall ratio (p = 0.02) on the early days of exposure, compared to controls. They also presented a progressive increment of inflammatory influx in the peribronchiolar area during the study (p = 0.04) and decrement of the eNOS expression on the 45th day of exposure in both vascular layers (p <= 0.03). We found that after 14 days of exposure, the ambient levels of air pollutants in Sao Paulo induced vasoconstriction that was associated with an increase in ETAr expression. These vascular results do not appear to be coupled to the progressive inflammatory influx in lung tissue, suggesting a down-regulation of vasoconstrictive mechanisms through an imbalance in the cytokines network. It is likely that these responses are protective measures that decrease tissue damage brought about by continuous exposure to air pollutants. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When linear equality constraints are invariant through time they can be incorporated into estimation by restricted least squares. If, however, the constraints are time-varying, this standard methodology cannot be applied. In this paper we show how to incorporate linear time-varying constraints into the estimation of econometric models. The method involves the augmentation of the observation equation of a state-space model prior to estimation by the Kalman filter. Numerical optimisation routines are used for the estimation. A simple example drawn from demand analysis is used to illustrate the method and its application.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A straightforward method is proposed for computing the magnetic field produced by a circular coil that contains a large number of turns wound onto a solenoid of rectangular cross section. The coil is thus approximated by a circular ring containing a continuous constant current density, which is very close to the real situation when sire of rectangular cross section is used. All that is required is to evaluate two functions, which are defined as integrals of periodic quantities; this is done accurately and efficiently using trapezoidal-rule quadrature. The solution can be obtained so rapidly that this procedure is ideally suited for use in stochastic optimization, An example is given, in which this approach is combined with a simulated annealing routine to optimize shielded profile coils for NMR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have previously shown that H-1 pulsed-field-gradient (PFG) NMR spectroscopy provides a facile method for monitoring protein self-association and can be used, albeit with some caveats, to measure the apparent molecular mass of the diffusant [Dingley et al. (1995) J. Biomol. NMR, 6, 321-328]. In this paper we show that, for N-15-labelled proteins, selection of H-1-N-15 multiple-quantum (MQ) coherences in PFG diffusion experiments provides several advantages over monitoring H-1 single-quantum (SQ) magnetization. First, the use of a gradient-selected MQ filter provides a convenient means of suppressing resonances from both the solvent and unlabelled solutes. Second, H-1-N-15 zero-quantum coherence dephases more rapidly than H-1 SQ coherence under the influence of a PFG. This allows the diffusion coefficients of larger proteins to be measured more readily. Alternatively, the gradient length and/or the diffusion delay may be decreased, thereby reducing signal losses from relaxation. In order to extend the size of macromolecules to which these experiments can be applied, we have developed a new MQ PFG diffusion experiment in which the magnetization is stored as longitudinal two-spin order for most of the diffusion period, thus minimizing sensitivity losses due to transverse relaxation and J-coupling evolution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Brazil, sugarcane fields are often burned to facilitate manual harvesting, and this burning causes environmental pollution from the large amounts of soot released into the atmosphere. This material contains numerous organic compounds such as PAHs. In this study, the concentrations of PAHs in two particulate-matter fractions (PM(2.5) and PM(10)) in the city of Araraquara (SE Brazil, with around 200,000 inhabitants and surrounded by sugarcane plantations) were determined during the sugarcane harvest (HV) and non-harvest (NHV) seasons in 2008 and 2009. The sampling strategy included four campaigns, with 60 samples in the NHV season and 220 samples in the HV season. The PM(2.5) and PM(10) fractions were collected using a dichotomous sampler (10 L min(-1), 24 h) with Teflon (TM) filters. The filter sets were extracted (ultrasonic bath with hexane/acetone (1:1 v/v)) and analyzed by HPLC/Fluorescence. The median concentration for total PAHs (PM(2.5) in 2009) was 0.99 ng m(-3) (NHV) and 3.3 ng m(-3) (HV). In the HV season, the total concentration of carcinogenic PAHs (benz(a)anthracene, benzo(b)fluoranthene, benzo(k)fluoranthene, and benzo(a)pyrene) was 5 times higher than in the NHV season. B(a)P median concentrations were 0.017 ng m(-3) and 0.12 ng m(-3) for the NHV and HV seasons, respectively. The potential cancer risk associated with exposure through inhalation of these compounds was estimated based on the benzo[a]pyrene toxic equivalence (BaP(eq)), where the overall toxicity of a PAR mixture is defined by the concentration of each compound multiplied by its relative toxic equivalence factor (TEF). BaP(eq) median (2008 and 2009 years) ranged between 0.65 and 1.0 ng m(-3) and 1.2-1.4 ng m(-3) for the NHV and HV seasons, respectively. Considering that the maximum permissible BaPeq in ambient air is 1 ng m(-3), related to the increased carcinogenic risk, our data suggest that the level of human exposure to PAHs in cities surrounded by sugarcane crops where the burning process is used is cause for concern. (C) 2010 Published by Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Some Latin American countries have plans for total control and/or eradication of Chagas disease by the main vector (Triatoma infestans) and by blood transfusion. To achieve this, patients with Chagas disease must be identified. A Western blotting test, TESAcruzi, is described as a supplemental test for diagnosis of Chagas disease using samples collected from children <5 years living in different states of Brazil. Blood samples collected by finger prick on filter paper were sent to the test laboratory by a central laboratory to confirm results obtained previously. Ten percent of negative samples, all doubtful and all positive samples were received. Commercial reagents, IgG indirect immunofluorescence, enzyme immunoassay, and a recently introduced TESAcruzi test were used. From 8788 samples, 163 (1.85%) were reactive by IgG-ELISA and 312 (3.55%) by IgG IIF. From these, 77 (0.87%) were reactive in the TESAcruzi test. The results had high clinical value to identify those truly infected. (C) 2010 Elsevier B.V. All rights reserved.