832 resultados para precision difference


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a measurement of the mass difference between t and t̄ quarks in lepton+jets final states of tt̄ events in 1fb-1 of data collected with the D0 detector from Fermilab Tevatron Collider pp̄ collisions at s=1.96TeV. The measured mass difference of 3.8±3.7GeV is consistent with the equality of t and t̄ masses. This is the first direct measurement of a mass difference between a quark and its antiquark partner. © 2009 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effectiveness of 3 solvents (eucalyptol, orange oil, and xylol) on 2 types of gutta-percha (conventional and thermoplastic) and Resilon. Specimens (10 mm diameter × 1 mm thick; n=7 per condition) were prepared and maintained at 37°C for 48 h. Each specimen was weighed on a precision scale every 24 h until its mass was stable, at which time the initial mass was determined. Specimens (n=7) were then immersed in the solvent solutions and, after 48 h at 37°C, they were reweighed at 24- h intervals, until stabilization (final mass). The difference between the final and the initial mass determined the solvent capacity of each solvent. Data were subjected to analysis of variance and Tukey's test at 5% significance level. The results demonstrated that xylol was the most effective, especially on conventional gutta-percha and Resilon (p<0.05). Eucalyptol and orange oil were more effective on thermoplastic gutta-percha than the other materials (p<0.05). It was concluded that all evaluated substances presented solvent action, but xylol was the most effective on both gutta-percha or Resilon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: There is little information considering the framework association between cast clasps and attachments. The aim of this study was to evaluate the retention strength of frameworks match circumferential clasps and extra resilient attachment cast in three different alloys (cobalt-chromium, nickel-chromium titanium and commercially pure titanium), using two undercut (0.25 and 0.75 mm) and considering different period of time (0, 1/2, 1, 2, 3, 4 and 5 years). Methods: Using two metallic matrices, representing a partially edentulous mandibular right hemiarch with the first molar crown, canine root and without premolars, 60 frameworks were fabricated. Three groups (n = 20) of each metal were cast and each group was divided into two subgroups (n = 10), corresponding the molar undercut of 0.25 mm and 0.75 mm. The nylon male was positioned at the matrix and attached to the acrylic resin of the prosthetic base. The samples were subjected to an insertion and removal test under artificial saliva environment. Results: The data were analyzed and compared with ANOVAs and Tukey's test at 95% of probability. The groups cast in cobaltchromium and nickel-chromium-titanium had the highest mean retention strength (5.58 N and 6.36 N respectively) without significant difference between them, but statistically different from the group cast in commercially pure titanium, which had the lowest mean retention strength in all the periods (3.46 N). The association frameworks using nickel-chromium-titanium and cobalt-chromium could be used with 0.25 mm and 0.75 mm of undercut, but the titanium samples seems to decrease the retention strength, mainly in the 0.75 mm undercut. The circumferential clasps cast in commercially pure titanium used in 0.75 mm undercuts have a potential risk of fractures, especially after the 2nd year of use. Conclusion: This in vitro study showed that the framework association between cast clasp and an extra resilient attachment are suitable to the three metals evaluated, but strongly suggest extra care with commercially pure titanium in undercut of 0.75 mm. Clinical significance: Frameworks fabricated in Cp Ti tend to decrease in retentive strength over time and have a potential risk of fracture in less than 0.75 mm of undercut.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of the present study was to evaluate the tissue dissolving capacity of various concentrations of sodium hypochlorite either alone or in combination with 17% EDTA. Methods: Eighty bovine pulp fragments were prepared, and their weight was determined using a precision balance. Each pulp fragment was immersed for 2 hours in a solution/mixture that was based on the following groups: G1-saline solution; G2-0.5% NaOCl; G3-1.0% NaOCl; G4-2.5% NaOCl; G5-17% EDTA; G6-0.5% NaOCl+17% EDTA; G7-1.0% NaOCl+ 17% EDTA; and G8-2.5% NaOCl+17% EDTA. The final weight was measured, and the weight loss was calculated. A statistical analysis was performed using either the Student's t-test for paired samples or an ANOVA and Tukey tests (P<0.05 was considered to be significant). Results: We measured a significant difference between the sample weight before and after treatment for each of the tested groups (P<0.05). The 2.5% sodium hypochlorite solution (G4) completely dissolved the pulp tissue within the test period. NaOCl+EDTA was less effective than sodium hypochlorite alone at dissolving the pulp tissue (P<0.05), and EDTA alone (G5) did not markedly dissolve the pulp tissue. Conclusion: Using EDTA together with NaOCl reduced the tissue dissolving properties compared with NaOCl alone, regardless of the concentration of NaOCl that was used. © 2011 Só et al.; licensee EDIPUCRS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New Galileo signals have great potential for pseudorange-based surveying and mapping in both optimal open-sky conditions and suboptimal under-canopy environments. This article reviews the main features of Galileo's E5 AItBO( and El (BOC signals, describes generation of realistic E5 and El pseudoranges with and without multipath sources, and presents anticipated horizontal positioning accuracy results, ranging from 4 centimeters (open-sky) to 14 centimeters (under-canopy) for E5/El.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A current trend in the agricultural area is the development of mobile robots and autonomous vehicles for precision agriculture (PA). One of the major challenges in the design of these robots is the development of the electronic architecture for the control of the devices. In a joint project among research institutions and a private company in Brazil a multifunctional robotic platform for information acquisition in PA is being designed. This platform has as main characteristics four-wheel propulsion and independent steering, adjustable width, span of 1,80m in height, diesel engine, hydraulic system, and a CAN-based networked control system (NCS). This paper presents a NCS solution for the platform guidance by the four-wheel hydraulic steering distributed control. The control strategy, centered on the robot manipulators control theory, is based on the difference between the desired and actual position and considering the angular speed of the wheels. The results demonstrate that the NCS was simple and efficient, providing suitable steering performance for the platform guidance. Even though the simplicity of the NCS solution developed, it also overcame some verified control challenges in the robot guidance system design such as the hydraulic system delay, nonlinearities in the steering actuators, and inertia in the steering system due the friction of different terrains. Copyright © 2012 Eduardo Pacincia Godoy et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to develop and evaluate a mathematical model used to estimate the daily amino acid requirements of individual growing-finishing pigs. The model includes empirical and mechanistic model components. The empirical component estimates daily feed intake (DFI), BW, and daily gain (DG) based on individual pig information collected in real time. Based on DFI, BW, and DG estimates, the mechanistic component uses classic factorial equations to estimate the optimal concentration of amino acids that must be offered to each pig to meet its requirements. The model was evaluated with data from a study that investigated the effect of feeding pigs with a 3-phase or daily multiphase system. The DFI and BW values measured in this study were compared with those estimated by the empirical component of the model. The coherence of the values estimated by the mechanistic component was evaluated by analyzing if it followed a normal pattern of requirements. Lastly, the proposed model was evaluated by comparing its estimates with those generated by the existing growth model (InraPorc). The precision of the proposed model and InraPorc in estimating DFI and BW was evaluated through the mean absolute error. The empirical component results indicated that the DFI and BW trajectories of individual pigs fed ad libitum could be predicted 1 d (DFI) or 7 d (BW) ahead with the average mean absolute error of 12.45 and 1.85%, respectively. The average mean absolute error obtained with the InraPorc for the average individual of the population was 14.72% for DFI and 5.38% for BW. Major differences were observed when estimates from InraPorc were compared with individual observations. The proposed model, however, was effective in tracking the change in DFI and BW for each individual pig. The mechanistic model component estimated the optimal standardized ileal digestible Lys to NE ratio with reasonable between animal (average CV = 7%) and overtime (average CV = 14%) variation. Thus, the amino acid requirements estimated by model are animal- and time-dependent and follow, in real time, the individual DFI and BW growth patterns. The proposed model can follow the average feed intake and feed weight trajectory of each individual pig in real time with good accuracy. Based on these trajectories and using classical factorial equations, the model makes it possible to estimate dynamically the AA requirements of each animal, taking into account the intake and growth changes of the animal. © 2012 American Society of Animal Science. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a practical experimentation for comparing reactive/non-active energy measures, considering three-phase four-wire non-sinusoidal and unbalanced circuits, involving five different commercial electronic meters. The experimentation set provides separately voltage and current generation, each one with any waveform involving up to fifty-first harmonic components, identically compared with acquisitions obtained from utility. The experimental accuracy is guaranteed by a class A power analyzer, according to IEC61000-4-30 standard. Some current and voltage combination profiles are presented and confronted with two different references of reactive/non-active calculation methodologies; instantaneous power theory and IEEE 1459-2010. The first methodology considers the instantaneous power theory, present into the advanced mathematical internal algorithm from WT3000 power analyzer, and the second methodology, accomplish with IEEE 1459-2010 standard, uses waveform voltage and current acquisition from WT3000 as input data for a virtual meter developed on Mathlab/Simulink software. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Jacobian singularities of differential operators in curvilinear coordinates occur when the Jacobian determinant of the curvilinear-to-Cartesian mapping vanishes, thus leading to unbounded coefficients in partial differential equations. Within a finite-difference scheme, we treat the singularity at the pole of polar coordinates by setting up complementary equations. Such equations are obtained by either integral or smoothness conditions. They are assessed by application to analytically solvable steady-state heat-conduction problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new method to estimate hole diameters and surface roughness in precision drilling processes, using coupons taken from a sandwich plate composed of a titanium alloy plate (Ti6Al4V) glued onto an aluminum alloy plate (AA 2024T3). The proposed method uses signals acquired during the cutting process by a multisensor system installed on the machine tool. These signals are mathematically treated and then used as input for an artificial neural network. After training, the neural network system is qualified to estimate the surface roughness and hole diameter based on the signals and cutting process parameters. To evaluate the system, the estimated data were compared with experimental measurements and the errors were calculated. The results proved the efficiency of the proposed method, which yielded very low or even negligible errors of the tolerances used in most industrial drilling processes. This pioneering method opens up a new field of research, showing a promising potential for development and application as an alternative monitoring method for drilling processes. © 2012 Springer-Verlag London Limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to identify the boundary of submaximal speed zones (i.e., exercise intensity domains) between maximal aerobic speed (S-400) and lactate threshold (LT) in swimming. A 400-m all-out test, a 7 × 200 m incremental step test, and two to four 30-minute submaximal tests were performed by 12 male endurance swimmers (age = 24.5 ± 9.6 years; body mass = 71.3 ± 9.8 kg) to determine S-400, speed corresponding to LT, and maximal lactate steady state (MLSS). S-400 was 1.30 ± 0.09 m·s -1 (400 m-5:08 minutes:seconds). The speed at LT (1.08 ± 0.02 m·s-1; 83.1 ± 2.2 %S-400) was lower than the speed at MLSS (1.14 ± 0.02 m·s-1; 87.5 ± 1.9 %S-400). Maximal lactate steady state occurred at 26 ± 10% of the difference between the speed at LT and S-400. Mean blood lactate values at the speeds corresponding to LT and MLSS were 2.45 ± 1.13 mmol·L-1 and 4.30 ± 1.32 mmol·L-1, respectively. The present findings demonstrate that the range of intensity zones between LT and MLSS (i.e., heavy domain) and between MLSS and S-400 (i.e., severe domain) are very narrow in swimming with LT occurring at 83% S-400 in trained swimmers. Precision and sensitivity of the measurement of aerobic indexes (i.e., LT and MLSS) should be considered when conducting exercise training and testing in swimming. © 2013 National Strength and Conditioning Association.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The precision agriculture technologies such as the spatial variability of soil attributes have been widely studied mostly with sugarcane. Among these technologies have been recently highlighted the use of the vegetation index derived from remote sensing products, such as powerful tools indicating the development of vegetation. This study aimed to analyze the spatial variability of clay content, pH and phosphorus in an Oxisol in an area with sugarcane production, and correlate with the Normalized Difference Vegetation Index (NDVI). The georeferenced grid was created for the soil properties (clay, phosphorus and pH) and generated the maps of spatial variability. For these same sites were calculated the NDVI, in addition to mapping of this ratio, the evaluation of the spatial correlation between this and other studied properties. The clay and phosphorus content showed positive spatial correlation with the NDVI, while no spatial correlation was observed between NDVI and pH. The satellite images from the sensor ETM + Landsat were used to correlate to NDVI to observe the spatial variability of the studied attributes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La exactitud de las mediciones de las variables a partir de las encuestas de hogares, depende de la precision de las estimaciones o errores de muestreo de los estimadores y de la presencia de sesgos o errores sistematicos, tanto en la seleccion de la muestra como en la medicion de las caracteristicas investigadas. La eleccion del diseno muestral depende de la informacion requerida, del personal de campo disponible y de otros factores. La representatividad y tamano de la muestra se relacionan con los objetivos de la investigacion y los errores de muestreo deben ser calculados para determinar la exactitud del procedimiento y de ahi fijar limites a la interpretacion de los resultados. En este sentido, se discuten los problemas asociados a la estimacion de las tasas de actividad, de desempleo y de distribucion del ingreso