973 resultados para polarization multiplexing holographic recording
Resumo:
Routine milk recording data, often covering many years, are available for approximately half the dairy herds of England and Wales. In addition to milk yield and quality, these data include production events that can be used to derive objective Key Performance Indicators (KPI) describing a herd's fertility and production. Recent developments in information systems give veterinarians and other technical advisers access to these KPIs on-line. In addition to reviewing individual herd performance, advisers can establish local benchmark groups to demonstrate the relative performance of similar herds in the vicinity. The use of existing milk recording data places no additional demands on farmer's time or resources. These developments could also readily be exploited by universities to introduce veterinary undergraduates to the realities of commercial dairy production.
Resumo:
Cashew (Anacardium occidentale L.) is the most economically important tropical nut crop in the world, and yet there are no sequence tagged site (STS) markers available for its study. Here we use an automated, high-throughput system to isolate cashew microsatellites from a non-enriched genomic library blotted onto membranes at high density for screening. Sixty-five sequences contained a microsatellite array, of which 21 proved polymorphic among a closely related seed garden population of 49 genotypes. Twelve markers were suitable for multiplex analysis. Of these, 10 amplified in all three related tropical tree species tested: Anacardium microcarpum, Anacardium pumilum and Anacardium nanum.
Resumo:
We investigate the processes involved in writing real-time holographic gratings in a photorefractive polymer (PRP) that incorporates an azo-dye. In such systems there may be gratings due to mechanisms associated with trans–cis isomerization (angular hole burning (AHB) and/or angular redistribution), which appear in addition to those arising from the photorefractive (PR) effect. The work presented here helps to understand the interactions which may occur between these different gratings. The formation of local gratings due to mechanisms associated with photoisomerization is studied, in a new PRP based on the photoconductor poly(N-vinylcarbazole):2, 4, 7-trinitro-9-fluorenone, plasticized with N-ethylcarbazole. The polymer includes the azo-dye 4-nitro-4'-pentyloxy-azobenzene and we observe both PR and photoisomerization gratings. The gratings are shown to be both polarization-sensitive and reversible. The presence of the photoisomerization gratings (which diffract almost as strongly as the PR gratings) significantly affects the field-dependent diffractive behaviour of the composite. A measurement of the lifetime of the cis state is made (τcis = 38 s) using photoinduced dichroism. This is close to the decay time constant of the local gratings (τdecay = 42 s), and it is suggested that the local grating mechanism is AHB of the azo-dye. This is the first time (to the knowledge of the authors) that a local grating due to AHB has been demonstrated in a PRP.
Resumo:
An experiment published in this Journal has been revisited and it is found that the curve pattern of the anodic polarization curve for iron repeats itself successively when the potential scan is repeated. It is surprising that this observation has not been reported previously in the literature because it immediately brings into question the long accepted and well-known explanations involving a passive film. A qualitative and plausible explanation is provided from surprisingly simple principles for this new finding. Some important pedagogic conclusions have been derived from this work. It is noteworthy that the somewhat complicated phenomenon can be simply explained, thus providing two important lessons to students. First, even well-accepted scientific work studying simple processes may be incomplete and worthy of further study, and second, such processes may be explained simply at the undergraduate level. The contents of the paper also confirm that presenting curricular contents in a new and more correct manner is beneficial, interesting, and that research in curricular contents represents one of the important forms of educational research.
Resumo:
Infrared polarization and intensity imagery provide complementary and discriminative information in image understanding and interpretation. In this paper, a novel fusion method is proposed by effectively merging the information with various combination rules. It makes use of both low-frequency and highfrequency images components from support value transform (SVT), and applies fuzzy logic in the combination process. Images (both infrared polarization and intensity images) to be fused are firstly decomposed into low-frequency component images and support value image sequences by the SVT. Then the low-frequency component images are combined using a fuzzy combination rule blending three sub-combination methods of (1) region feature maximum, (2) region feature weighting average, and (3) pixel value maximum; and the support value image sequences are merged using a fuzzy combination rule fusing two sub-combination methods of (1) pixel energy maximum and (2) region feature weighting. With the variables of two newly defined features, i.e. the low-frequency difference feature for low-frequency component images and the support-value difference feature for support value image sequences, trapezoidal membership functions are proposed and developed in tuning the fuzzy fusion process. Finally the fused image is obtained by inverse SVT operations. Experimental results of visual inspection and quantitative evaluation both indicate the superiority of the proposed method to its counterparts in image fusion of infrared polarization and intensity images.
Resumo:
This article discusses the international legal obligation to identify and record every casualty of armed conflict that finds its basis in the treaties and customs of international humanitarian law and international human rights law. The article applies the various facets of the legal obligation to the armed conflicts in Iraq and Sri Lanka and argues that the parties in these conflicts failed in their international legal responsibility to civilians.
Resumo:
Neuroprostheses interfaced with transected peripheral nerves are technological routes to control robotic limbs as well as convey sensory feedback to patients suffering from traumatic neural injuries or degenerative diseases. To maximize the wealth of data obtained in recordings, interfacing devices are required to have intrafascicular resolution and provide high signal-to-noise ratio (SNR) recordings. In this paper, we focus on a possible building block of a three-dimensional regenerative implant: a polydimethylsiloxane (PDMS) microchannel electrode capable of highly sensitive recordings in vivo. The PDMS 'micro-cuff' consists of a 3.5 mm long (100 µm × 70 µm cross section) microfluidic channel equipped with five evaporated Ti/Au/Ti electrodes of sub-100 nm thickness. Individual electrodes have average impedance of 640 ± 30 kΩ with a phase angle of −58 ± 1 degrees at 1 kHz and survive demanding mechanical handling such as twisting and bending. In proof-of-principle acute implantation experiments in rats, surgically teased afferent nerve strands from the L5 dorsal root were threaded through the microchannel. Tactile stimulation of the skin was reliably monitored with the three inner electrodes in the device, simultaneously recording signal amplitudes of up to 50 µV under saline immersion. The overall SNR was approximately 4. A small but consistent time lag between the signals arriving at the three electrodes was observed and yields a fibre conduction velocity of 30 m s−1. The fidelity of the recordings was verified by placing the same nerve strand in oil and recording activity with hook electrodes. Our results show that PDMS microchannel electrodes open a promising technological path to 3D regenerative interfaces.
Resumo:
We are reporting on the fabrication and electrical characterization of a novel elastomer based micro-cuff neural interface. Electrodes are gold (Au) tracks of sub-100nm thickness and are thermally evaporated on a 0.5 mm thick polydimethylsiloxane (PDMS) substrate. We investigate how electrode area and immersion in phosphate buffered saline (PBS) at 37°C influence electrode impedance. A microfluidic channel is bonded to the electrode array to form the cuff. In an acute, in-vivo, proof-of-principle recording, the device is capable of detecting light stroking and pinch of a hind leg of an anaesthetized rat.
Resumo:
We have fabricated a compliant neural interface to record afferent nerve activity. Stretchable gold electrodes were evaporated on a polydimethylsiloxane (PDMS) substrate and were encapsulated using photo-patternable PDMS. The built-in microstructure of the gold film on PDMS allows the electrodes to twist and flex repeatedly, without loss of electrical conductivity. PDMS microchannels (5mm long, 100μm wide, 100μm deep) were then plasma bonded irreversibly on top of the electrode array to define five parallel-conduit implants. The soft gold microelectrodes have a low impedance of ~200kΩ at the 1kHz frequency range. Teased nerves from the L6 dorsal root of an anaesthetized Sprague Dawley rat were threaded through the microchannels. Acute tripolar recordings of cutaneous activity are demonstrated, from multiple nerve rootlets simultaneously. Confinement of the axons within narrow microchannels allows for reliable recordings of low amplitude afferents. This electrode technology promises exciting applications in neuroprosthetic devices including bladder fullness monitors and peripheral nervous system implants.