980 resultados para modified FCI test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mesophilic Anaerobic Digestion treating sewage sludge was investigated at five full-scale sewage treatment plants in Ireland. The anaerobic digestion plants are compared and evaluated in terms of design, equipment, operation, monitoring and management. All digesters are cylindrical, gas mixed and heated Continuously Stirred Tank Reactors (CSTR), varying in size from 130m3 to 800m3. Heat exchanger systems heat all digesters. Three plants reported difficulties with the heating systems ranging from blockages to insufficient insulation and design. Exchangers were modified and replaced within one year of operation at two plants. All but one plant had Combined Heat and Power (CHP) systems installed. Parameter monitoring is a problem at all plants mainly due to a lack of staff and knowledge. The plant operators consider pH and temperature the most important parameters to be measured in terms of successful monitoring of an anaerobic digester. The short time taken and the ease at which pH and temperature can be measured may favour these parameters. Three laboratory scale pilot anaerobic digesters were operated using a variety of feeds over at 144-day period. Two of the pilots were unmixed and the third was mechanically mixed. As expected the unmixed reactors removed more COD by retention of solids in the digesters but also produced greater quantities of biogas than the mixed digester, especially when low solids feed such as whey was used. The mixed digester broke down more solids due to the superior contact between the substrate and the biomass. All three reactors showed good performance results for whey and sewage solids. Scum formation occurred giving operational problems for mixed and unmixed reactors when cattle slurry was used as the main feed source. The pilot test was also used to investigate which parameters were the best indicators of process instability. These trials clearly indicated that total Volatile Fatty Acid (VFA) concentrations was the best parameter to show signs of early process imbalance, while methane composition in the biogas was good to indicate possible nutrient deficiencies in the feed and oxygen shocks. pH was found to be a good process parameter only if the wastewater being treated produced low bicarbonate alkalinities during treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O teste de inclinação (TI) é muito utilizado para a investigação de síncopes e pré-síncopes, pois possibilita o diagnóstico de diferentes tipos de disautonomias. A principal causa de síncope é a Síndrome Vasovagal, cujo diagnóstico é o mais frequente entre as indicações de TI. O exame é utilizado há cerca de 20 anos, mas muitos médicos desconhecem a metodologia. São importantes a indicação apropriada, após exclusão de causas cardíacas de síncope, e a orientação do paciente para garantir a tranquilidade e a segurança do teste. Existem controvérsias na literatura sobre a capacidade diagnóstica e a confiabilidade dos resultados. Os estudos com protocolos diversos podem explicar a variabilidade dos resultados. Nesta revisão, são colocadas as indicações e a metodologia recomendadas pelas diretrizes, complicações, limitações e perspectivas desse exame.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Studies have demonstrated the diagnostic accuracy and prognostic value of physical stress echocardiography in coronary artery disease. However, the prediction of mortality and major cardiac events in patients with exercise test positive for myocardial ischemia is limited. Objective: To evaluate the effectiveness of physical stress echocardiography in the prediction of mortality and major cardiac events in patients with exercise test positive for myocardial ischemia. Methods: This is a retrospective cohort in which 866 consecutive patients with exercise test positive for myocardial ischemia, and who underwent physical stress echocardiography were studied. Patients were divided into two groups: with physical stress echocardiography negative (G1) or positive (G2) for myocardial ischemia. The endpoints analyzed were all-cause mortality and major cardiac events, defined as cardiac death and non-fatal acute myocardial infarction. Results: G2 comprised 205 patients (23.7%). During the mean 85.6 ± 15.0-month follow-up, there were 26 deaths, of which six were cardiac deaths, and 25 non-fatal myocardial infarction cases. The independent predictors of mortality were: age, diabetes mellitus, and positive physical stress echocardiography (hazard ratio: 2.69; 95% confidence interval: 1.20 - 6.01; p = 0.016). The independent predictors of major cardiac events were: age, previous coronary artery disease, positive physical stress echocardiography (hazard ratio: 2.75; 95% confidence interval: 1.15 - 6.53; p = 0.022) and absence of a 10% increase in ejection fraction. All-cause mortality and the incidence of major cardiac events were significantly higher in G2 (p < 0. 001 and p = 0.001, respectively). Conclusion: Physical stress echocardiography provides additional prognostic information in patients with exercise test positive for myocardial ischemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Physiological reflexes modulated primarily by the vagus nerve allow the heart to decelerate and accelerate rapidly after a deep inspiration followed by rapid movement of the limbs. This is the physiological and pharmacologically validated basis for the 4-s exercise test (4sET) used to assess the vagal modulation of cardiac chronotropism. Objective: To present reference data for 4sET in healthy adults. Methods: After applying strict clinical inclusion/exclusion criteria, 1,605 healthy adults (61% men) aged between 18 and 81 years subjected to 4sET were evaluated between 1994 and 2014. Using 4sET, the cardiac vagal index (CVI) was obtained by calculating the ratio between the duration of two RR intervals in the electrocardiogram: 1) after a 4-s rapid and deep breath and immediately before pedaling and 2) at the end of a rapid and resistance-free 4-s pedaling exercise. Results: CVI varied inversely with age (r = -0.33, p < 0.01), and the intercepts and slopes of the linear regressions between CVI and age were similar for men and women (p > 0.05). Considering the heteroscedasticity and the asymmetry of the distribution of the CVI values according to age, we chose to express the reference values in percentiles for eight age groups (years): 18–30, 31–40, 41–45, 46–50, 51–55, 56–60, 61–65, and 66+, obtaining progressively lower median CVI values ranging from 1.63 to 1.24. Conclusion: The availability of CVI percentiles for different age groups should promote the clinical use of 4sET, which is a simple and safe procedure for the evaluation of vagal modulation of cardiac chronotropism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractBackground:Myocardial perfusion scintigraphy (MPS) in patients not reaching 85% of the maximum predicted heart rate (MPHR) has reduced sensitivity.Objectives:In an attempt to maintain diagnostic sensitivity without losing functional exercise data, a new exercise and dipyridamole combined protocol (EDCP) was developed. Our aim was to evaluate the feasibility and safety of this protocol and to compare its diagnostic sensitivity against standard exercise and dipyridamole protocols.Methods:In patients not reaching a sufficient exercise (SE) test and with no contraindications, 0.56 mg/kg of dipyridamole were IV administered over 1 minute simultaneously with exercise, followed by 99mTc-MIBI injection.Results:Of 155 patients, 41 had MPS with EDCP, 47 had a SE test (≥ 85% MPHR) and 67 underwent the dipyridamole alone test (DIP). They all underwent coronary angiography within 3 months. The three stress methods for diagnosis of coronary lesions had their sensitivity compared. For stenosis ≥ 70%, EDCP yielded 97% sensitivity, SE 90% and DIP 95% (p = 0.43). For lesions ≥ 50%, the sensitivities were 94%, 88% and 95%, respectively (p = 0.35). Side effects of EDCP were present in only 12% of the patients, significantly less than with DIP (p < 0.001).Conclusions:The proposed combined protocol is a valid and safe method that yields adequate diagnostic sensitivity, keeping exercise prognostic information in patients unable to reach target heart rate, with fewer side effects than the DIP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Familial amyloidotic polyneuropathy (FAP) is a rare disease diagnosed in Brazil and worldwide. The frequency of cardiovascular involvement in Brazilian FAP patients is unknown.Objective:Detect the frequency of cardiovascular involvement and correlate the cardiovascular findings with the modified polyneuropathy disability (PND) score.Methods:In a national reference center, 51 patients were evaluated with clinical examination, electrocardiography (ECG), echocardiography (ECHO), and 24-hour Holter. Patients were classified according to the modified PND score and divided into groups: PND 0, PND I, PND II, and PND > II (which included PND IIIa, IIIb, and IV). We chose the classification tree as the statistical method to analyze the association between findings in cardiac tests with the neurological classification (PND).Results:ECG abnormalities were present in almost 2/3 of the FAP patients, whereas ECHO abnormalities occurred in around 1/3 of them. All patients with abnormal ECHO also had abnormal ECG, but the opposite did not apply. The classification tree identified ECG and ECHO as relevant variables (p < 0.001 and p = 0.08, respectively). The probability of a patient to be allocated to the PND 0 group when having a normal ECG was over 80%. When both ECG and ECHO were abnormal, this probability was null.Conclusions:Brazilian patients with FAP have frequent ECG abnormalities. ECG is an appropriate test to discriminate asymptomatic carriers of the mutation from those who develop the disease, whereas ECHO contributes to this discrimination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Informatik, Diss., 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: Recent studies have shown changes in cardiac autonomic control of obese preadolescents. Objective: To assess the heart rate responses and cardiac autonomic modulation of obese preadolescents during constant expiratory effort. Methods: This study assessed 10 obese and 10 non-obese preadolescents aged 9 to 12 years. The body mass index of the obese group was between the 95th and 97th percentiles of the CDC National Center for Health Statistics growth charts, while that of the non-obese group, between the 5th and 85th percentiles. Initially, they underwent anthropometric and clinical assessment, and their maximum expiratory pressures were obtained. Then, the preadolescents underwent a constant expiratory effort of 70% of their maximum expiratory pressure for 20 seconds, with heart rate measurement 5 minutes before, during and 5 minutes after it. Heart rate variability (HRV) and heart rate values were analyzed by use of a software. Results: The HRV did not differ when compared before and after the constant expiratory effort intra- and intergroup. The heart rate values differed (p < 0.05) during the effort, being the total variation in non-obese preadolescents of 18.5 ± 1.5 bpm, and in obese, of 12.2 ± 1.3 bpm. Conclusion: The cardiac autonomic modulation did not differ between the groups when comparing before and after the constant expiratory effort. However, the obese group showed lower cardiovascular response to baroreceptor stimuli during the effort, suggesting lower autonomic baroreflex sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: The kinetics of high-sensitivity troponin T (hscTnT) release should be studied in different situations, including functional tests with transient ischemic abnormalities. Objective: To evaluate the release of hscTnT by serial measurements after exercise testing (ET), and to correlate hscTnT elevations with abnormalities suggestive of ischemia. Methods: Patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary angioplasty were referred for ET 3 months after infarction. Blood samples were collected to measure basal hscTnT immediately before (TnT0h), 2 (TnT2h), 5 (TnT5h), and 8 hours (TnT8h) after ET. The outcomes were peak hscTnT, TnT5h/TnT0h ratio, and the area under the blood concentration-time curve (AUC) for hscTnT levels. Log-transformation was performed on hscTnT values, and comparisons were assessed with the geometric mean ratio, along with their 95% confidence intervals. Statistical significance was assessed by analysis of covariance with no adjustment, and then, adjusted for TnT0h, age and sex, followed by additional variables (metabolic equivalents, maximum heart rate achieved, anterior wall STEMI, and creatinine clearance). Results: This study included 95 patients. The highest geometric means were observed at 5 hours (TnT5h). After adjustments, peak hscTnT, TnT5h/TnT0h and AUC were 59% (p = 0.002), 59% (p = 0.003) and 45% (p = 0.003) higher, respectively, in patients with an abnormal ET as compared to those with normal tests. Conclusion: Higher elevations of hscTnT may occur after an abnormal ET as compared to a normal ET in patients with STEMI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wireless mesh networks present an attractive communication solution for various research and industrial projects. However, in many cases, the appropriate preliminary calculations which allow predicting the network behavior have to be made before the actual deployment. For such purposes, network simulation environments emulating the real network operation are often used. Within this paper, a behavior comparison of real wireless mesh network (based on 802.11s amendment) and the simulated one has been performed. The main objective of this work is to measure performance parameters of a real 802.11s wireless mesh network (average UDP throughput and average one-way delay) and compare the derived results with characteristics of a simulated wireless mesh network created with the NS-3 network simulation tool. Then, the results from both networks are compared and the corresponding conclusion is made. The corresponding results were derived from simulation model and real-worldtest-bed, showing that the behavior of both networks is similar. It confirms that the NS-3 simulation model is accurate and can be used in further research studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Das Prozessleitsystem PCS 7 beinhaltet softwaretechnische Lösungen für alle Hierarchieebenen der industriellen Automatisierung von der Unternehmensleitebene bis zur Anlagenfeldebene. Mit der Simulationssoftware WinMOD können Komponenten,Signale und Prozesse einer Industrieanlage nachgebildet werden. Zudem bietet WinMOD Schnittstellenlösungen für gängige Speicherprogrammierbare Steuerungen und eignet sich somit für den Factory Acceptance Test (FAT) von Prozessleitsystemen. Die FATs sollen sich hauptsächlich auf die Überprüfung von Signaladressierungen und von Ursache und Wirkung konzentrieren. Im Rahmen der vorliegenden Arbeit wurden ausgewählte PCS 7–Projekte untersucht und auf deren Grundlage Aussagen getroffen wie zukünftig Simulationen effektiv erstellt werden können. Hierzu wurden mithilfe von WinMOD Simulationsmodule angelegt - welche reale Komponenten des Anlagenfeldes ersetzen – , ihr Aufbau beschrieben und in einer Bibliothek zusammengefasst. Im Anschluss wird auf die Verwendung der Bibliothek für verschiedene Anwendungsfälle eingegangen und eine Lösung präsentiert, welche das Erstellen einer Simulation für spezifische Projekte optimiert. Das Ergebnis zeigt auf, dass WinMOD sowohl neue Möglichkeiten der Durchführung für einen FAT liefert, wobei die Simulationserstellung nur einen geringen Mehraufwand bedeutet und sich die Durchführung der Simulation ergonomischer und kürzer gestaltet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies have been carried out on the method of Britton and Silvette modified by Reinecke and Kendall, for the evaluation of cortico-adrenal extracts, based on the deposition of glycogen in the liver of adrenaletomized rats. The test was performed in a total of 180 normal and adrenalectomized rats. The extracts tested were: a) an aqueous extract of cortico-adrenal cortex prepared by the Swingle and Pfiffner technique; b) the same extract added with ascorbic acid (Supracortin Labor); c) desoxycorticosterone acetate (Percortol Ciba and Syncortyl Roussell). Male rats were used, ranging from 40-200g, fed since the 18 th days old with a special diet, in which they were maintained until the day before the injection. Adrenalectomy was performed under urethane anesthesia. The fourth day after operation, food was removed and they were fasted for 24 hours. In the morning of the fifth day, injections of the material to be assayed were given at hourly and two hours intervals, during four to eight hours. One or two hours after the last injection, the animals were sacrified, the livers removed and dropped into a hot 30% solution of potassium hydroxide, and worked by Good, Kramer and Somogyi method. The glycogen was calculated as milligrams per lOOg of body and liver weight. The results obtained are shown in the tables I, II, and III. When several dosages of the same sample of extract were made (5 animals each dose), the amount of glycogen deposited in the liver per lOOg of body and liver weight, was found to be a positive function of the dose injected. The graph 2, shows these results. The synthetic compounds were ineffective. Our results are in agreement with those of Reinecke and Kendall and of Olson et al.