884 resultados para methods of measurement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reliability of measurement refers to unsystematic error in observed responses. Investigations of the prevalence of random error in stated estimates of willingness to pay (WTP) are important to an understanding of why tests of validity in CV can fail. However, published reliability studies have tended to adopt empirical methods that have practical and conceptual limitations when applied to WTP responses. This contention is supported in a review of contingent valuation reliability studies that demonstrate important limitations of existing approaches to WTP reliability. It is argued that empirical assessments of the reliability of contingent values may be better dealt with by using multiple indicators to measure the latent WTP distribution. This latent variable approach is demonstrated with data obtained from a WTP study for stormwater pollution abatement. Attitude variables were employed as a way of assessing the reliability of open-ended WTP (with benchmarked payment cards) for stormwater pollution abatement. The results indicated that participants' decisions to pay were reliably measured, but not the magnitude of the WTP bids. This finding highlights the need to better discern what is actually being measured in VVTP studies, (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite current imperatives to measure client outcomes, social workers have expressed frustration with the ability of traditional forms of quantitative methods to engage with complexity, individuality and meaning. This paper argues that the inclusion of a meaning-based as opposed to a function-based approach to quality of life (QOL) may offer a quantitative means of measurement that is congruent with social-work values and practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The involvement of oxidatively modified low density lipoprotein (LDL) in the development of CHD is widely described. We have produced two antibodies, recognizing the lipid oxidation product malondialdehyde (MDA) on whole LDL or ApoB-100. The antibodies were utilized in the development of an ELISA for quantitation of MDA-LDL in human plasma. Intra- and inter-assay coefficients of variation (% CV) were measured as 4.8 and 7.7%, respectively, and sensitivity of the assay as 0.04 μg/ml MDA-LDL. Recovery of standard MDA-LDL from native LDL was 102%, indicating the ELISA to be specific with no interference from other biomolecules. Further validation of the ELISA was carried out against two established methods for measurement of lipid peroxidation products, MDA by HPLC and F2-isoprostanes by GC-MS. Results indicated that MDA-LDL is formed at a later stage of oxidation than either MDA or F2- isoprostanes. In vivo analysis demonstrated that the ELISA was able to determine steady-state concentrations of plasma MDA-LDL (an end marker of lipid peroxidation). A reference range of 34.3 ± 8.8 μg/ml MDA-LDL was established for healthy individuals. Further, the ELISA was used to show significantly increased plasma MDA-LDL levels in subjects with confirmed ischemic heart disease, and could therefore possibly be of benefit as a diagnostic tool for assessing CHD risk. © 2003 Elsevier Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Intensive Care Unit (ICU) being one of those vital areas of a hospital providing clinical care, the quality of service rendered must be monitored and measured quantitatively. It is, therefore, essential to know the performance of an ICU, in order to identify any deficits and enable the service providers to improve the quality of service. Although there have been many attempts to do this with the help of illness severity scoring systems, the relative lack of success using these methods has led to the search for a form of measurement, which would encompass all the different aspects of an ICU in a holistic manner. The Analytic Hierarchy Process (AHP), a multiple-attribute, decision-making technique is utilised in this study to evolve a system to measure the performance of ICU services reliably. This tool has been applied to a surgical ICU in Barbados; we recommend AHP as a valuable tool to quantify the performance of an ICU. Copyright © 2004 Inderscience Enterprises Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper discusses the use of comparative performance measurement by means of Data Envelopment Analysis in the context of the regulation of English and Welsh water companies. Specifically, the use of Data Envelopment Analysis to estimate potential cost savings in sewerage is discussed as it fed into the price review of water companies carried out by the regulator of water companies in 1994. The application is used as a vehicle for highlighting generic issues in terms of assessing the impact of factors on the ranking of units on performance, the insights gained from using alternative methods to assess comparative performance, and the issue of assessing comparative performance when few in number but highly complex entities are involved. The paper should prove of interest to those interested in regulation and, more generally, in the use of methods of comparative performance measurement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study is concerned with several proposals concerning multiprocessor systems and with the various possible methods of evaluating such proposals. After a discussion of the advantages and disadvantages of several performance evaluation tools, the author decides that simulation is the only tool powerful enough to develop a model which would be of practical use, in the design, comparison and extension of systems. The main aims of the simulation package developed as part of this study are cost effectiveness, ease of use and generality. The methodology on which the simulation package is based is described in detail. The fundamental principles are that model design should reflect actual systems design, that measuring procedures should be carried out alongside design that models should be well documented and easily adaptable and that models should be dynamic. The simulation package itself is modular, and in this way reflects current design trends. This approach also aids documentation and ensures that the model is easily adaptable. It contains a skeleton structure and a library of segments which can be added to or directly swapped with segments of the skeleton structure, to form a model which fits a user's requirements. The study also contains the results of some experimental work carried out using the model, the first part of which tests• the model's capabilities by simulating a large operating system, the ICL George 3 system; the second part deals with general questions and some of the many proposals concerning multiprocessor systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An initial aim of this project was to evaluate the conventional techniques used in the analysis of newly prepared environmentally friendly water-borne automotive coatings and compare them with solvent-borne coatings having comparable formulations. The investigation was carried out on microtuned layers as well as on complete automotive multi-layer paint systems. Methods used included the very traditional methods of gloss and hardness and the commonly used photo-oxidation index (from FTIR spectral analysis). All methods enabled the durability to weathering of the automotive coatings to be initially investigated. However, a primary aim of this work was to develop methods for analysing the early stages of chemical and property changes in both the solvent-borne and water-borne coating systems that take place during outdoor natural weathering exposures and under accelerated artificial exposures. This was achieved by using dynamic mechanical analysis (DMA), in both tension mode on the microtomed films (on all depths of the coating systems from the uppermost clear-coat right down to the electron-coat) and bending mode of the full (unmicrotomed) systems, as well as MALDI-Tof analysis on the movement of the stabilisers in the full systems. Changes in glass transition temperature and relative cross-link density were determined after weathering and these were related to changes in the chemistries of the binder systems of the coatings after weathering. Concentration profiles of the UV-stabilisers (UVA and HALS) in the coating systems were analysed as a consequence of migration in the coating systems in separate microtomed layers of the paint samples (depth profiling) after weathering and diffusion co-efficient and solubility parameters were determined for the UV stabilisers in the coating systems. The methods developed were used to determine the various physical and chemical changes that take place during weathering of the different (water-borne and solvent-borne) systems (photoxidation). The solvent-borne formulations showed less changes after weathering (both natural and accelerated) than the corresponding water-borne formulations due to the lower level of cross-links in the binders of the water-borne systems. The silver systems examined were more durable than the blue systems due to the reflecting power of the aluminium and the lower temperature of the silver coatings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For a Switched Reluctance Motor (SRM), the flux linkage characteristic is the most basic magnetic characteristic, and many other quantities, including the incremental inductance, back emf, and electromagnetic torque can be determined indirectly from it. In this paper, two methods of measuring the flux linkage profile of an SRM from the phase winding voltage and current measurements, with and without rotor locking devices, are presented. Torque, incremental inductance and back emf characteristics of the SRM are then obtained from the flux linkage measurements. The torque of the SRM is also measured directly as a comparison, and the closeness of the calculated and directly measured torque curves suggests the validity of the method to obtain the SRM torque, incremental inductance and back emf profiles from the flux linkage measurements. © 2013 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new experimental technique is presented for making measurements of biaxial residual stress using load and depth sensing indentation (nanoindentation). The technique is based on spherical indentation, which, in certain deformation regimes, can be much more sensitive to residual stress than indentation with sharp pyramidal indenters like the Berkovich. Two different methods of analysis were developed: one requiring an independent measure of the material's yield strength and the other a reference specimen in the unstressed state or other known reference condition. Experiments conducted on aluminum alloys to which controlled biaxial bending stresses were applied showed that the methods are capable of measuring the residual stress to within 10-20% of the specimen yield stress. Because the methods do not require imaging of the hardness impressions, they are potentially useful for making localized measurements of residual stress, as in thin films or small volumes, or for characterization of point-to-point spatial variations of the surface stress.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this work is the development of database of the distributed information measurement and control system that implements methods of optical spectroscopy for plasma physics research and atomic collisions and provides remote access to information and hardware resources within the Intranet/Internet networks. The database is based on database management system Oracle9i. Client software was realized in Java language. The software was developed using Model View Controller architecture, which separates application data from graphical presentation components and input processing logic. The following graphical presentations were implemented: measurement of radiation spectra of beam and plasma objects, excitation function for non-elastic collisions of heavy particles and analysis of data acquired in preceding experiments. The graphical clients have the following functionality of the interaction with the database: browsing information on experiments of a certain type, searching for data with various criteria, and inserting the information about preceding experiments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In dimensional metrology, often the largest source of uncertainty of measurement is thermal variation. Dimensional measurements are currently scaled linearly, using ambient temperature measurements and coefficients of thermal expansion, to ideal metrology conditions at 20˚C. This scaling is particularly difficult to implement with confidence in large volumes as the temperature is unlikely to be uniform, resulting in thermal gradients. A number of well-established computational methods are used in the design phase of product development for the prediction of thermal and gravitational effects, which could be used to a greater extent in metrology. This paper outlines the theory of how physical measurements of dimension and temperature can be combined more comprehensively throughout the product lifecycle, from design through to the manufacturing phase. The Hybrid Metrology concept is also introduced: an approach to metrology, which promises to improve product and equipment integrity in future manufacturing environments. The Hybrid Metrology System combines various state of the art physical dimensional and temperature measurement techniques with established computational methods to better predict thermal and gravitational effects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Passive sampling devices (PS) are widely used for pollutant monitoring in water, but estimation of measurement uncertainties by PS has seldom been undertaken. The aim of this work was to identify key parameters governing PS measurements of metals and their dispersion. We report the results of an in situ intercomparison exercise on diffusive gradient in thin films (DGT) in surface waters. Interlaboratory uncertainties of time-weighted average (TWA) concentrations were satisfactory (from 28% to 112%) given the number of participating laboratories (10) and ultra-trace metal concentrations involved. Data dispersion of TWA concentrations was mainly explained by uncertainties generated during DGT handling and analytical procedure steps. We highlight that DGT handling is critical for metals such as Cd, Cr and Zn, implying that DGT assembly/dismantling should be performed in very clean conditions. Using a unique dataset, we demonstrated that DGT markedly lowered the LOQ in comparison to spot sampling and stressed the need for accurate data calculation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several protocols for isolation of mycobacteria from water exist, but there is no established standard method. This study compared methods of processing potable water samples for the isolation of Mycobacterium avium and Mycobacterium intracellulare using spiked sterilized water and tap water decontaminated using 0.005% cetylpyridinium chloride (CPC). Samples were concentrated by centrifugation or filtration and inoculated onto Middlebrook 7H10 and 7H11 plates and Lowenstein-Jensen slants and into mycobacterial growth indicator tubes with or without polymyxin, azlocillin, nalidixic acid, trimethoprim, and amphotericin B. The solid media were incubated at 32°C, at 35°C, and at 35°C with CO2 and read weekly. The results suggest that filtration of water for the isolation of mycobacteria is a more sensitive method for concentration than centrifugation. The addition of sodium thiosulfate may not be necessary and may reduce the yield. Middlebrook M7H10 and 7H11 were equally sensitive culture media. CPC decontamination, while effective for reducing growth of contaminants, also significantly reduces mycobacterial numbers. There was no difference at 3 weeks between the different incubation temperatures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Protein-energy wasting (PEW) is commonly seen in patients with chronic kidney disease (CKD). The condition is characterised by chronic, systemic low-grade inflammation which affects nutritional status by a variety of mechanisms including reducing appetite and food intake and increasing muscle catabolism. PEW is linked with co-morbidities such as cardiovascular disease, and is associated with lower quality of life, increased hospitalisations and a 6-fold increase in risk of death1. Significant gender differences have been found in the severity and effects of several markers of PEW. There have been limited studies testing the ability of anti-inflammatory agents or nutritional interventions to reduce the effects of PEW in dialysis patients. This thesis makes a significant contribution to the understanding of PEW in dialysis patients. It advances understanding of measurement techniques for two of the key components, appetite and inflammation, and explores the effect of fish oil, an anti-inflammatory agent, on markers of PEW in dialysis patients. The first part of the thesis consists of two methodological studies conducted using baseline data. The first study aims to validate retrospective ratings of hunger, desire to eat and fullness on visual analog scales (VAS) (paper and pen and electronic) as a new method of measuring appetite in dialysis patients. The second methodological study aims to assess the ability of a variety of methods available in routine practice to detect the presence of inflammation. The second part of the thesis aims to explore the effect of 12 weeks supplementation with 2g per day of Eicosapentaenoic Acid (EPA), a longchain fatty acid found in fish oil, on markers of PEW. A combination of biomarkers and psychomarkers of appetite and inflammation are the main outcomes being explored, with nutritional status, dietary intake and quality of life included as secondary outcomes. A lead in phase of 3 months prior to baseline was used so that each person acts as their own historical control. The study also examines whether there are gender differences in response to the treatment. Being an exploratory study, an important part of the work is to test the feasibility of the intervention, thus the level of adherence and factors associated with adherence are also presented. The studies were conducted at the hemodialysis unit of the Wesley Hospital. Participants met the following criteria: adult, stage 5 CKD on hemodialysis for at least 3 months, not expected to receive a transplant or switch to another dialysis modality during the study, absence of intellectual impairment or mental illness impairing ability to follow instructions or complete the intervention. A range of intermediate, clinical and patient-centred outcome measures were collected at baseline and 12 weeks. Inflammation was measured using five biomarkers: c-reactive protein (CRP), interleukin-6 (IL6), intercellular adhesion molecule (sICAM-1), vascular cell adhesion molecule (sVCAM-1) and white cell count (WCC). Subjective appetite was measured using the first question from the Appetite and Dietary Assessment (ADAT) tool and VAS for measurements of hunger, desire to eat and fullness. A novel feature of the study was the assessment of the appetite peptides leptin, ghrelin and peptide YY as biomarkers of appetite. Nutritional status/inflammation was assessed using the Malnutrition-Inflammation Score (MIS) and the Patient-Generated Subjective Global Assessment (PG-SGA). Dietary intake was measured using 3-day records. Quality of life was measured using the Kidney Disease Quality of Life Short Form version 1.3 (KDQOL-SF™ v1.3 © RAND University), which combines the Short-Form 36 (SF36) with a kidney-disease specific module2. A smaller range of these variables was available for analysis during the control phase (CRP, ADAT, dietary intake and nutritional status). Statistical analysis was carried out using SPSS version 14 (SPSS Inc, Chicago IL, USA). Analysis of the first part of the thesis involved descriptive and bivariate statistics, as well as Bland-Altman plots to assess agreement between methods, and sensitivity analysis/ROC curves to test the ability of methods to predict the presence of inflammation. The unadjusted (paired ttests) and adjusted (linear mixed model) change over time is presented for the main outcome variables of inflammation and appetite. Results are shown for the whole group followed by analyses according to gender and adherence to treatment. Due to the exploratory nature of the study, trends and clinical significance were considered as important as statistical significance. Twenty-eight patients (mean age 61±17y, 50% male, dialysis vintage 19.5 (4- 101) months) underwent baseline assessment. Seven out of 28 patients (25%) reported sub-optimal appetite (self-reported as fair, poor or very poor) despite all being well nourished (100% SGA A). Using the VAS, ratings of hunger, but not desire to eat or fullness, were significantly (p<0.05) associated with a range of relevant clinical variables including age (r=-0.376), comorbidities (r=-0.380) nutritional status (PG-SGA score, r=-0.451), inflammatory markers (CRP r=-0.383; sICAM-1 r=-0.387) and seven domains of quality of life. Patients expressed a preference for the paper and pen method of administering VAS. None of the tools (appetite, MIS, PG-SGA, albumin or iron) showed an acceptable ability to detect patients who are inflamed. It is recommended that CRP should be tested more frequently as a matter of course rather than seeking alternative methods of measuring inflammation. 27 patients completed the 12 week intervention. 20 patients were considered adherent based on changes in % plasma EPA, which rose from 1.3 (0.94)% to 5.2 (1.1)%, p<0.001, in this group. The major barriers to adherence were forgetting to take the tablets as well as their size. At 12 weeks, inflammatory markers remained steady apart from the white cell count which decreased (7.6(2.5) vs 7.0(2.2) x109/L, p=0.058) and sVCAM-1 which increased (1685(654) vs 2249(925) ng/mL, p=0.001). Subjective appetite using VAS increased (51mm to 57mm, +12%) and there was a trend towards reduction in peptide YY (660(31) vs 600(30) pg/mL, p=0.078). There were some gender differences apparent, with the following adjusted change between baseline and week 12: CRP (males -3% vs females +17%, p=0.19), IL6 (males +17% vs females +48%, p=0.77), sICAM-1 (males -5% vs females +11%, p=0.07), sVCAM-1 (males +54% vs females +19%, p=0.08) and hunger ratings (males 20% vs females -5%, p=0.18). On balance, males experienced a maintainence or reduction in three inflammatory markers and an improvement in hunger ratings, and therefore appeared to have responded better to the intervention. Compared to those who didn’t adhere, adherent patients maintained weight (mean(SE) change: +0.5(1.6) vs - 0.8(1.2) kg, p=0.052) and fat-free mass (-0.1 (1.6) vs -1.8 (1.8) kg, p=0.045). There was no difference in change between the intervention and control phase for CRP, appetite, nutritional status or dietary intake. The thesis makes a significant contribution to the evidence base for understanding of PEW in dialysis patients. It has advanced knowledge of methods of assessing inflammation and appetite. Retrospective ratings of hunger on a VAS appear to be a valid method of assessing appetite although samples which include patients with very poor appetite are required to confirm this. Supplementation with fish oil appeared to improve subjective appetite and dampen the inflammatory response. The effectiveness of the intervention is influenced by gender and adherence. Males appear to be more responsive to the primary outcome variables than females, and the quality of response is improved with better adherence. These results provide evidence to support future interventions aimed at reducing the effects of PEW in dialysis patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Motor vehicles are a major source of gaseous and particulate matter pollution in urban areas, particularly of ultrafine sized particles (diameters < 0.1 µm). Exposure to particulate matter has been found to be associated with serious health effects, including respiratory and cardiovascular disease, and mortality. Particle emissions generated by motor vehicles span a very broad size range (from around 0.003-10 µm) and are measured as different subsets of particle mass concentrations or particle number count. However, there exist scientific challenges in analysing and interpreting the large data sets on motor vehicle emission factors, and no understanding is available of the application of different particle metrics as a basis for air quality regulation. To date a comprehensive inventory covering the broad size range of particles emitted by motor vehicles, and which includes particle number, does not exist anywhere in the world. This thesis covers research related to four important and interrelated aspects pertaining to particulate matter generated by motor vehicle fleets. These include the derivation of suitable particle emission factors for use in transport modelling and health impact assessments; quantification of motor vehicle particle emission inventories; investigation of the particle characteristic modality within particle size distributions as a potential for developing air quality regulation; and review and synthesis of current knowledge on ultrafine particles as it relates to motor vehicles; and the application of these aspects to the quantification, control and management of motor vehicle particle emissions. In order to quantify emissions in terms of a comprehensive inventory, which covers the full size range of particles emitted by motor vehicle fleets, it was necessary to derive a suitable set of particle emission factors for different vehicle and road type combinations for particle number, particle volume, PM1, PM2.5 and PM1 (mass concentration of particles with aerodynamic diameters < 1 µm, < 2.5 µm and < 10 µm respectively). The very large data set of emission factors analysed in this study were sourced from measurement studies conducted in developed countries, and hence the derived set of emission factors are suitable for preparing inventories in other urban regions of the developed world. These emission factors are particularly useful for regions with a lack of measurement data to derive emission factors, or where experimental data are available but are of insufficient scope. The comprehensive particle emissions inventory presented in this thesis is the first published inventory of tailpipe particle emissions prepared for a motor vehicle fleet, and included the quantification of particle emissions covering the full size range of particles emitted by vehicles, based on measurement data. The inventory quantified particle emissions measured in terms of particle number and different particle mass size fractions. It was developed for the urban South-East Queensland fleet in Australia, and included testing the particle emission implications of future scenarios for different passenger and freight travel demand. The thesis also presents evidence of the usefulness of examining modality within particle size distributions as a basis for developing air quality regulations; and finds evidence to support the relevance of introducing a new PM1 mass ambient air quality standard for the majority of environments worldwide. The study found that a combination of PM1 and PM10 standards are likely to be a more discerning and suitable set of ambient air quality standards for controlling particles emitted from combustion and mechanically-generated sources, such as motor vehicles, than the current mass standards of PM2.5 and PM10. The study also reviewed and synthesized existing knowledge on ultrafine particles, with a specific focus on those originating from motor vehicles. It found that motor vehicles are significant contributors to both air pollution and ultrafine particles in urban areas, and that a standardized measurement procedure is not currently available for ultrafine particles. The review found discrepancies exist between outcomes of instrumentation used to measure ultrafine particles; that few data is available on ultrafine particle chemistry and composition, long term monitoring; characterization of their spatial and temporal distribution in urban areas; and that no inventories for particle number are available for motor vehicle fleets. This knowledge is critical for epidemiological studies and exposure-response assessment. Conclusions from this review included the recommendation that ultrafine particles in populated urban areas be considered a likely target for future air quality regulation based on particle number, due to their potential impacts on the environment. The research in this PhD thesis successfully integrated the elements needed to quantify and manage motor vehicle fleet emissions, and its novelty relates to the combining of expertise from two distinctly separate disciplines - from aerosol science and transport modelling. The new knowledge and concepts developed in this PhD research provide never before available data and methods which can be used to develop comprehensive, size-resolved inventories of motor vehicle particle emissions, and air quality regulations to control particle emissions to protect the health and well-being of current and future generations.