947 resultados para method comparison
Resumo:
A new and simple fabrication technique is reported for the UV inscription of intrinsically apodized chirped fibre gratings at an arbitrary Bragg wavelength employing a single chirped phase-mask in a scanning Talbot interferometer set-up. Chirped gratings have been successfully produced over a large wavelength range and with bandwidths up to 5 nm. These gratings exhibit the time-delay response of a small ripple effect. In the present paper a comparison with previously reported fabrication methods is given, showing the advantages and disadvantages of the different methods.
Resumo:
Background and Objective: Clozapine has been available since the early 1990s. Studies continue to demonstrate its superior efficacy in treatment-resistant schizophrenia. Despite this, numerous studies show under-utilisation, delayed access and reluctance by psychiatrists to prescribe clozapine. This retrospective cross-sectional study compared the prescribing of clozapine in two adult cohorts under the care of large public mental health services in Auckland (New Zealand) and Birmingham (United Kingdom) on 31 March 2007. Method: Time from first presentation to clozapine initiation, prior antipsychotics trialled and antipsychotic co-prescribing were compared. Data included demographics, psychiatric diagnosis, co-morbid conditions, year of first presentation, admissions and pharmacological treatment (clozapine dose, start date, prior antipsychotics, co-prescribed antipsychotic). Results: Overall, 664 people were prescribed clozapine (402 Auckland; 262 Birmingham); mean daily dose of 384 mg (Auckland) and 429 mg (Birmingham). 53 % presented after 1990 and the average duration of time before starting clozapine was significantly longer in the Birmingham cohort (6.5 vs. 5.3 years) but this reduced in both cohorts to a 1-year mean in those presenting within the last 3 years. The average number of antipsychotics trialled pre-clozapine for those presenting since 1990 was significantly higher in the Birmingham cohort (4.3 vs. 3.1) but in both cohorts this similarly reduced in those presenting within the last 3 years. Antipsychotic co-prescribing was significantly higher in the Birmingham cohort (22.9 vs. 10.7 %). Conclusions: There is evidence that access to clozapine has improved over time in both cohorts, with a reduction in the duration between presentation and initiation of clozapine and number of different antipsychotics trialled pre-clozapine. These are very positive findings in terms of optimising outcomes with clozapine and are possibly due to the impact of guideline recommendations, increasing clinician, consumer and carer knowledge, and experience with clozapine and funding changes. © 2014 Springer International Publishing.
Resumo:
Usually, data mining projects that are based on decision trees for classifying test cases will use the probabilities provided by these decision trees for ranking classified test cases. We have a need for a better method for ranking test cases that have already been classified by a binary decision tree because these probabilities are not always accurate and reliable enough. A reason for this is that the probability estimates computed by existing decision tree algorithms are always the same for all the different cases in a particular leaf of the decision tree. This is only one reason why the probability estimates given by decision tree algorithms can not be used as an accurate means of deciding if a test case has been correctly classified. Isabelle Alvarez has proposed a new method that could be used to rank the test cases that were classified by a binary decision tree [Alvarez, 2004]. In this paper we will give the results of a comparison of different ranking methods that are based on the probability estimate, the sensitivity of a particular case or both.
Resumo:
Clogging is the main operational problem associated with horizontal subsurface flow constructed wetlands (HSSF CWs). The measurement of saturated hydraulic conductivity has proven to be a suitable technique to assess clogging within HSSF CWs. The vertical and horizontal distribution of hydraulic conductivity was assessed in two full-scale HSSF CWs by using two different in situ permeameter methods (falling head (FH) and constant head (CH) methods). Horizontal hydraulic conductivity profiles showed that both methods are correlated by a power function (FH= CH 0.7821, r 2=0.76) within the recorded range of hydraulic conductivities (0-70 m/day). However, the FH method provided lower values of hydraulic conductivity than the CH method (one to three times lower). Despite discrepancies between the magnitudes of reported readings, the relative distribution of clogging obtained via both methods was similar. Therefore, both methods are useful when exploring the general distribution of clogging and, specially, the assessment of clogged areas originated from preferential flow paths within full-scale HSSF CWs. Discrepancy between methods (either in magnitude and pattern) aroused from the vertical hydraulic conductivity profiles under highly clogged conditions. It is believed this can be attributed to procedural differences between the methods, such as the method of permeameter insertion (twisting versus hammering). Results from both methods suggest that clogging develops along the shortest distance between water input and output. Results also evidence that the design and maintenance of inlet distributors and outlet collectors appear to have a great influence on the pattern of clogging, and hence the asset lifetime of HSSF CWs. © Springer Science+Business Media B.V. 2011.
Resumo:
Purpose: To assess the inter and intra observer variability of subjective grading of the retinal arterio-venous ratio (AVR) using a visual grading and to compare the subjectively derived grades to an objective method using a semi-automated computer program. Methods: Following intraocular pressure and blood pressure measurements all subjects underwent dilated fundus photography. 86 monochromatic retinal images with the optic nerve head centred (52 healthy volunteers) were obtained using a Zeiss FF450+ fundus camera. Arterio-venous ratios (AVR), central retinal artery equivalent (CRAE) and central retinal vein equivalent (CRVE) were calculated on three separate occasions by one single observer semi-automatically using the software VesselMap (ImedosSystems, Jena, Germany). Following the automated grading, three examiners graded the AVR visually on three separate occasions in order to assess their agreement. Results: Reproducibility of the semi-automatic parameters was excellent (ICCs: 0.97 (CRAE); 0.985 (CRVE) and 0.952 (AVR)). However, visual grading of AVR showed inter grader differences as well as discrepancies between subjectively derived and objectively calculated AVR (all p < 0.000001). Conclusion: Grader education and experience leads to inter-grader differences but more importantly, subjective grading is not capable to pick up subtle differences across healthy individuals and does not represent true AVR when compared with an objective assessment method. Technology advancements mean we no longer rely on opthalmoscopic evaluation but can capture and store fundus images with retinal cameras, enabling us to measure vessel calibre more accurately compared to visual estimation; hence it should be integrated in optometric practise for improved accuracy and reliability of clinical assessments of retinal vessel calibres. © 2014 Spanish General Council of Optometry.
Resumo:
We present experimental studies and numerical modeling based on a combination of the Bidirectional Beam Propagation Method and Finite Element Modeling that completely describes the wavelength spectra of point by point femtosecond laser inscribed fiber Bragg gratings, showing excellent agreement with experiment. We have investigated the dependence of different spectral parameters such as insertion loss, all dominant cladding and ghost modes and their shape relative to the position of the fiber Bragg grating in the core of the fiber. Our model is validated by comparing model predictions with experimental data and allows for predictive modeling of the gratings. We expand our analysis to more complicated structures, where we introduce symmetry breaking; this highlights the importance of centered gratings and how maintaining symmetry contributes to the overall spectral quality of the inscribed Bragg gratings. Finally, the numerical modeling is applied to superstructure gratings and a comparison with experimental results reveals a capability for dealing with complex grating structures that can be designed with particular wavelength characteristics.
Resumo:
Theoretical developments on pinning control of complex dynamical networks have mainly focused on the deterministic versions of the model dynamics. However, the dynamical behavior of most real networks is often affected by stochastic noise components. In this paper the pinning control of a stochastic version of the coupled map lattice network with spatiotemporal characteristics is studied. The control of these complex dynamical networks have functional uncertainty which should be considered when calculating stabilizing control signals. Two feedback control methods are considered: the conventional feedback control and modified stochastic feedback control. It is shown that the typically-used conventional control method suffers from the ignorance of model uncertainty leading to a reduction and potentially a collapse in the control efficiency. Numerical verification of the main result is provided for a chaotic coupled map lattice network. © 2011 IEEE.
Resumo:
A new 3D implementation of a hybrid model based on the analogy with two-phase hydrodynamics has been developed for the simulation of liquids at microscale. The idea of the method is to smoothly combine the atomistic description in the molecular dynamics zone with the Landau-Lifshitz fluctuating hydrodynamics representation in the rest of the system in the framework of macroscopic conservation laws through the use of a single "zoom-in" user-defined function s that has the meaning of a partial concentration in the two-phase analogy model. In comparison with our previous works, the implementation has been extended to full 3D simulations for a range of atomistic models in GROMACS from argon to water in equilibrium conditions with a constant or a spatially variable function s. Preliminary results of simulating the diffusion of a small peptide in water are also reported.
Resumo:
Some species of crustose lichens, such as Ochrolechia parella (L.) Massal., exhibit concentric marginal rings, which may represent an alternative technique of measuring growth rates and potentially, a new lichenometric dating method. To examine this hypothesis, the agreement and correlation between ring widths and directly measured annual radial growth rates (RaGR, mm a-1) were studied in 24 thalli of O. parella in north Wales, UK, using digital photography and image analysis. Variation in ring width was observed at different locations around a thallus, between thalli, and from year to year. The best agreement and correlation between ring width and lichen growth rates was between mean width of the outer two rings (measured in 2011) and mean RaGR (in 2009/10). The O. parella data suggest that mean width of the youngest two growth rings, averaged over a sample of thalli, is a predictor of recent growth rates and therefore could be used in lichenometry. Potential applications include as a convenient method of comparing lichen growth rates on surfaces in different environmental settings; and as an alternative method of constructing lichen growth-rate curves, without having to revisit the same lichen thalli over many years. However, care is needed when using growth rings to estimate growth rates as: growth ring widths may not be stable; ring widths exhibit spatial and temporal variation; rings may not represent 1-year's growth in all thalli; and adjacent rings may not always represent successive year's growth.
Resumo:
This paper details work carried out to verify the dimensional measurement performance of the Indoor GPS (iGPS) system; a network of Rotary-Laser Automatic Theodolites (R-LATs). Initially tests were carried out to determine the angular uncertainties on an individual R-LAT transmitter-receiver pair. A method is presented of determining the uncertainty of dimensional measurement for a three dimensional coordinate measurement machine. An experimental procedure was developed to compare three dimensional coordinate measurements with calibrated reference points. The reference standard used to calibrate these reference points was a fringe counting interferometer with the multilateration technique employed to establish three dimensional coordinates. This is an extension of the established technique of comparing measured lengths with calibrated lengths. The method was found to be practical and able to establish that the expanded uncertainty of the basic iGPS system was approximately 1 mm at a 95% confidence level. Further tests carried out on a highly optimized version of the iGPS system have shown that the coordinate uncertainty can be reduced to 0.25 mm at a 95% confidence level.
Resumo:
External metrology systems are increasingly being integrated with traditional industrial articulated robots, especially in the aerospace industries, to improve their absolute accuracy for precision operations such as drilling, machining and jigless assembly. While currently most of the metrology assisted robotics control systems are limited in their position update rate, such that the robot has to be stopped in order to receive a metrology coordinate update, some recent efforts are addressed toward controlling robots using real-time metrology data. The indoor GPS is one of the metrology systems that may be used to provide real-time 6DOF data to a robot controller. Even if there is a noteworthy literature dealing with the evaluation of iGPS performance, there is, however, a lack of literature on how well the iGPS performs under dynamic conditions. This paper presents an experimental evaluation of the dynamic measurement performance of the iGPS, tracking the trajectories of an industrial robot. The same experiment is also repeated using a laser tracker. Besides the experiment results presented, this paper also proposes a novel method for dynamic repeatability comparisons of tracking instruments. © 2011 Springer-Verlag London Limited.
Resumo:
This paper details a method of estimating the uncertainty of dimensional measurement for a three-dimensional coordinate measurement machine. An experimental procedure was developed to compare three-dimensional coordinate measurements with calibrated reference points. The reference standard used to calibrate these reference points was a fringe counting interferometer with a multilateration-like technique employed to establish three-dimensional coordinates. This is an extension of the established technique of comparing measured lengths with calibrated lengths. Specifically a distributed coordinate measurement device was tested which consisted of a network of Rotary-Laser Automatic Theodolites (R-LATs), this system is known commercially as indoor GPS (iGPS). The method was found to be practical and was used to estimate that the uncertainty of measurement for the basic iGPS system is approximately 1 mm at a 95% confidence level throughout a measurement volume of approximately 10 m × 10 m × 1.5 m. © 2010 IOP Publishing Ltd.
Resumo:
PURPOSE: To compare the Parr-Hubbard and Knudtson formulas to calculate retinal vessel calibers and to examine the effect of omitting vessels on the overall result. METHODS: We calculated the central retinal arterial equivalent (CRAE) and central retinal venular equivalent (CRVE) according to the formulas described by Parr-Hubbard and Knudtson including the six largest retinal arterioles and venules crossing through a concentric ring segment (measurement zone) around the optic nerve head. Once calculated, we removed one arbitrarily selected artery and one arbitrarily selected vein and recalculated all outcome parameters again for (1) omitting one artery only, (2) omitting one vein only, and (3) omitting one artery and one vein. All parameters were compared against each other. RESULTS: Both methods showed good correlation (r for CRAE = 0.58; r for CRVE = 0.84), but absolute values for CRAE and CRVE were significantly different from each other when comparing both methods (p < 0.000001): CRAE had higher values for the Parr-Hubbard (165 [±16] μm) method compared with the Knudtson method (148 [±15] μm). In addition, CRAE and CRVE values dropped for both methods when omitting one arbitrarily selected vessel each (all p < 0.000001). Arteriovenous ratio (AVR) calculations showed a similar change for both methods when omitting one vessel each: AVR decreased when omitting one arteriole whereas it increased when omitting one venule. No change, however, was observed for AVR calculated with six or five vessel pairs each. CONCLUSIONS: Although the absolute value for CRAE and CRVE is changing significantly depending on the number of vessels included, AVR appears to be comparable as long as the same number of arterioles and venules is included.
Resumo:
We demonstrate an accurate BER estimation method for QPSK CO-OFDM transmission based on the probability density function of the received QPSK symbols. Using a 112Gbs QPSK CO-OFDM transmission as an example, we show that this method offers the most accurate estimate of the system's performance in comparison with other known approaches.
Resumo:
An iterative method for computing the channel capacity of both discrete and continuous input, continuous output channels is proposed. The efficiency of new method is demonstrated in comparison with the classical Blahut - Arimoto algorithm for several known channels. Moreover, we also present a hybrid method combining advantages of both the Blahut - Arimoto algorithm and our iterative approach. The new method is especially efficient for the channels with a priory unknown discrete input alphabet.