936 resultados para mercury preconcentration
Resumo:
Fluvoxamine (FVX) can be reduced at a mercury- drop electrode, with a maximum peak current intensity being obtained at a potential of -0.7 V vs. Ag/ AgCl, in an aqueous electrolyte solution of pH 2. The compound was determined in a pharmaceutical product and in spiked human serum by square-wave adsorptivestripping voltammetry (SWAdSV) after accumulation at the electrode surface, under batch conditions. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine FVX in the pharmaceutical product by use of a flow-injection analysis (FIA) system with SWAdSV detection. The methods developed were validated and successfully applied to the quantification of FVX in a pharmaceutical product. Recoveries between 76 and 89% were obtained in serum analysis. The FIA– SWAdSV method enabled analysis of up to 120 samples per hour at reduced cost, implying the possibility of competing with the chromatographic methods usually used for this analysis.
Resumo:
Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with SWAdSV detection (FIA-SWAdSV) were developed for the determination of paroxetine (PRX). The methods were based on the reduction of PRX at a mercury drop electrode at −1.55V versus Ag/AgCl, in a borate buffer of pH 8.8, and the possibility of accumulating the compound at the electrode surface. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine PRX using FIASWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs. Both methods developed were validated and successfully applied to the quantification of PRX in pharmaceutical products.
Resumo:
Studies were undertaken to determine the adsorption behavior of α-cypermethrin [R)-α-cyano-3-phenoxybenzyl(1S)-cis- 3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropanecarboxylate, and (S)-α-cyano-3-phenoxybenzyl (1R)-cis-3-(2,2-dichlorovinyl)-2,2- dimethylcyclopropanecarboxylate] in solutions on granules of cork and activated carbon (GAC). The adsorption studies were carried out using a batch equilibrium technique. A gas chromatograph with an electron capture detector (GC-ECD) was used to analyze α-cypermethrin after solid phase extraction with C18 disks. Physical properties including real density, pore volume, surface area and pore diameter of cork were evaluated by mercury porosimetry. Characterization of cork particles showed variations thereby indicating the highly heterogeneous structure of the material. The average surface area of cork particles was lower than that of GAC. Kinetics adsorption studies allowed the determination of the equilibrium time—24 hours for both cork (1–2 mm and 3–4 mm) and GAC. For the studied α-cypermethrin concentration range, GAC revealed to be a better sorbent. However, adsorption parameters for equilibrium concentrations, obtained through the Langmuir and Freundlich models, showed that granulated cork 1–2 mm have the maximum amount of adsorbed α-cypermethrin (qm) (303 μg/g); followed by GAC (186 μg/g) and cork 3-4 mm (136 μg/g). The standard deviation (SD) values, demonstrate that Freundlich model better describes the α-cypermethrin adsorption phenomena on GAC, while α-cypermethrin adsorption on cork (1-2 mm and 3-4 mm) is better described by the Langmuir. In view of the adsorption results obtained in this study it appears that granulated cork may be a better and a cheaper alternative to GAC for removing α-cypermethrin from water.
Resumo:
Aflowinjection squarewave cathodic stripping voltammetric method has been developed for the determination of sertraline in a pharmaceutical preparation. The method shows linearity between peak current intensity and sertraline concentration for the interval between 0.20×10−6 and 1.20×10−6 mol L−1. Limits of detection and quantification were found to be 1.5×10−7 and 5.0×10−7 mol L−1, respectively. Up to 70 samples per hour can be analysed with a good precision (R.S.D. = 2.5%). The proposed method was successfully applied to the determination of sertraline in a commercial product. In the voltammetric determination of sertraline in flow, a high sample rate is obtained at reduced costs, opening the possibility to compete with the chromatographic methods generally used for this analysis.
Resumo:
A detailed study of voltammetric behavior of ethiofencarb (ETF) is reported using glassy carbon electrode (GCE) and hanging mercury drop electrode (HMDE). With GCE, it is possible to verify that the oxidative mechanism is irreversible, independent of pH, and the maximum intensity current was observed at +1.20 V vs. AgCl/Ag at pH 1.9. A linear calibration line was obtained from 1.0x10-4 to 8.0x10-4 mol L-1 with SWV method. To complete the electrochemical knowledge of ETF pesticide, the reduction was also explored with HMDE. A well-defined peak was observed at –1.00V vs. AgCl/Ag in a large range of pH with higher signal at pH 7.0. Linearity was obtained in 4.2x10-6 and 9.4x10-6 mol L-1 ETF concentration range. An immediate alkaline hydrolysis of ETF was executed, producing a phenolic compound (2-ethylthiomethylphenol) (EMP), and the electrochemical activity of the product was examined. It was deduced that it is oxidized on GCE at +0.75V vs. AgCl/Ag with a maximum peak intensity current at pH 3.2, but the compound had no reduction activity on HMDE. Using the decrease of potential peak, a flow injection analysis (FIA) system was developed connected to an amperometric detector, enabling the determination of EMP over concentration range of 1.0x10-7 and 1.0x10-5 mol L-1 at a sampling rate of 60 h-1. The results provided by FIA methodology were performed by comparison with results from high-performance liquid chromatography (HPLC) technique and demonstrated good agreement with relative deviations lower than 4%. Recovery trials were performed and the obtained values were between 98 and 104%.
Resumo:
The ecotoxicological response of the living organisms in an aquatic system depends on the physical, chemical and bacteriological variables, as well as the interactions between them. An important challenge to scientists is to understand the interaction and behaviour of factors involved in a multidimensional process such as the ecotoxicological response.With this aim, multiple linear regression (MLR) and principal component regression were applied to the ecotoxicity bioassay response of Chlorella vulgaris and Vibrio fischeri in water collected at seven sites of Leça river during five monitoring campaigns (February, May, June, August and September of 2006). The river water characterization included the analysis of 22 physicochemical and 3 microbiological parameters. The model that best fitted the data was MLR, which shows: (i) a negative correlation with dissolved organic carbon, zinc and manganese, and a positive one with turbidity and arsenic, regarding C. vulgaris toxic response; (ii) a negative correlation with conductivity and turbidity and a positive one with phosphorus, hardness, iron, mercury, arsenic and faecal coliforms, concerning V. fischeri toxic response. This integrated assessment may allow the evaluation of the effect of future pollution abatement measures over the water quality of Leça River.
Resumo:
Recent studies have shown that, besides the well-recognized T3 and T4 hormones, there are other relevant thyroid hormones circulating in the human body. In particular, this is the case for 3-iodothyronamine (T1AM) and thyronamine (T0AM). One of the reasons for the lack of studies showing their precise importance is the absence of analytical methodologies available. Herein, for the first time, T1AM and T0AM are electrochemically characterized. T0AM was sensed by means of a glassy carbon electrode; furthermore, T1AM was sensed both with a graphitic surface (oxidatively) as well as with mercury (reductively). For both compounds, after oxidation, it was possible to observe the reversible redox reaction concerning the benzoquinone/hydroquinone couple, thus increasing the specificity of the electroanalysis. Therefore, this work provides the basis for an ‘at-point-of-use’ electrochemical strip test for T1AM and T0AM.
Resumo:
Trabalho Final de mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica
Resumo:
O leite é um alimento complexo, pela sua composição rico em água, proteínas, lípidos, vitaminas e minerais. Devido ao seu alto valor nutricional é fundamental para a amamentação de crianças e animais em crescimento, pois fornece componentes fundamentais para o desenvolvimento e manutenção da saúde. Os antimicrobianos são amplamente utilizados como uma medida terapêutica no tratamento de infeções bacterianas, profilaxia e como promotores de crescimento (aditivos). A presença de resíduos de antimicrobianos no leite pode representar riscos para a saúde humana, como reações alérgicas em indivíduos hipersensíveis e resistências. Os objetivos deste estudo são o desenvolvimento de novos métodos de limpeza e de pré-concentração para amostras de leite, por meio de extração em fase sólida (SPE), com a finalidade de realizar uma melhor identificação e quantificação de antimicrobiana por Cromatografia Líquida de Alta Performance (HPLC). Todos os métodos desenvolvidos são de fácil execução, com taxas de recuperação dos agentes antimicrobianos viáveis, com uma percentagem de recuperação a partir de 85%. O método cromatográfico utilizado para a deteção e quantificação (HPLC-DAD) têm os limites de deteção (LD) entre 2.43ng / mL e 1.62ng / mL e os limites de quantificação (LQ) entre 7,36 ng / mL e 4.92 ng / mL, o que significa este método vai de encontro às diretrizes estipuladas pela União Europeia para os agentes antimicrobianos estudados. A combinação dos métodos propostos de limpeza e pré-concentração por SPE e multirresíduo por HPLC-DAD permite, por conseguinte, a deteção e quantificação de resíduos de antibióticos no leite, tornando esta uma alternativa importante e útil no processo de controlo de qualidade para a indústria de alimentos e outras área.
Resumo:
Thesis submitted to Faculdade de Ciências e Tecnologia from Universidade Nova de Lisboa in partial fulfillment of the requirements for the obtention of the degree of Master of Science in Biotechnology
Resumo:
The far infrared reflectance of Sb2Te3 , Sbi.97Vo.o3Te3 and Sbi.94Cr .o6Te3 was measured near normal incidence at different temperatures (between 45K and 300K). The direct current resistivities of the above samples were also measured between the temperatures of 4K and 300K. Also Kramers Kronig (KK) analyses were performed on the reflectance spectra to obtain the optical conductivities. In the doped samples, it was observed that a phonon at 62cm-1 softens to about 55cm-1 on decreasing the temperature from 295K to 45K. Also, it was observed that the plasma frequency of the doped samples is independent of doping. The scattering rate for the vanadium doped sample was seen to be greater than that for the chromium doped sample despite the fact that vanadium impurity density is less than that of chromium. The Drude-Lorentz model fits to the KK optical conductivity show that the samples used in this work are conventional metals. Definitive measurements of the temperature dependence of the scattering rate across the ferromagnetic transition await equipment changes allowing measurements at low temperature using the mercury cadmium telluride (MCT) detector.
Resumo:
Microwave digestions of mercury in Standards Reference Material (SRM) coal samples with nitric acid and hydrogen peroxide in quartz vessels were compared with Teflon® vessel digestion by using flow injection cold vapor atomic absorption spectrometry. Teflon® vessels gave poor reproducibiUty and tended to deliver high values, while the digestion results from quartz vessel show good agreement with certificate values and better standard deviations. Trace level elements (Ag, Ba, Cd, Cr, Co, Cu, Fe, Mg, Mn, Mo, Pb, Sn, Ti, V and Zn) in used oil and residual oil samples were determined by inductively coupled plasma-optical emission spectrometry. Different microwave digestion programs were developed for each sample and most of the results are in good agreement with certified values. The disagreement with values for Ag was due to the precipitation of Ag in sample; while Sn, V and Zn values had good recoveries from the spike test, which suggests that these certified values might need to be reconsidered. Gold, silver, copper, cadmium, cobalt, nickel and zinc were determined by continuous hydride generation inductively coupled plasma-optical emission spectrometry. The performance of two sample introduction systems: MSIS™ and gas-liquid separator were compared. Under the respective optimum conditions, MSIS^"^ showed better sensitivity and lower detection limits for Ag, Cd, Cu, Co and similar values for Au, Ni and Zn to those for the gas-liquid separator.
Resumo:
Modifications to the commercial hydride generator, manufactured by Spectrametrics, resulted in improved operating procedure and enhancement of the arsenic and germanium signals. Experiments with arsenic(III) and arsenic(V) showed that identical reiults could be produced from both oxidation states. However, since arsenic(V) is reduced more slowly than arsenic(III), peak areas and not peak heights must be measured when the arsine is immediately stripped from the system (approximately 5 seconds reaction). When the reduction is allowed to proceed for 20 seconds before the arsine is stripped, peak heights may be used. For a 200 ng/mL solution, the relative standard deviation is 2.8% for As(III) and 3.8% for As(V). The detection limit for arsenic using the modified system is 0.50 ng/mL. Studies performed on As(V) standards show that the interferences from 1000 mg/L of nickel(II), cobalt(II), iron(III), copper(II), cadmium(II), and zinc(II) can be eliminated with the aid of 5 M Hel and 3% L-cystine. Conditions for the reduction of germanium to the corresponding hydride were investigated. The effect of different concentrations of HCl on the reduction of germanium to the covalent hydride in aqueous media by means of NaBH 4 solutions was assessed. Results show that the best response is accomplished at a pH of 1.7. The use of buffer solutions was similarly characterized. In both cases, results showed that the element is best reduced when the final pH of the solution after reaction is almost neutral. In addition, a more sensitive method, which includes the use of (NH4)2S208' has been developed. A 20% increase in the germanium signal is registered when compared to the signal achieved with Hel alone. Moreover, under these conditions, reduction of germanium could be accomplished, even when the solution's pH is neutral. For a 100 ng/mL germanium standard the rsd is 3%. The detection limit for germanium in 0.05 M Hel medium (pH 1.7) is 0.10 ng/mL and 0.09 ng/mL when ammonium persulphate is used in conjunction with Hel. Interferences from 1000 mg/L of iron(III), copper(II), cobalt(II), nickel(II), cadmium(II), lead(II), mercury(II), aluminum(III), tin(IV), arsenic(III), arsenic(V) and zinc(II) were studied and characterized. In this regard, the use of (NH4)ZS20S and Hel at a pH of 1.7 proved to be a successful mixture in the sbppression of the interferences caused by iron, copper, aluminum, tin, lead, and arsenic. The method was applied to the determination of germanium in cherts and iron ores. In addition, experiments with tin(IV) showed that a 15% increase in the tin signal can be accomplished in the presence of 1 mL of (NH4)2S20S 10% (m/V).
Resumo:
Hg(18-Crown-6)C12 and Cd(18-Crown-6)C12 are isostructura1, space group Cl~ Z = 2. For the mercury compound, a = 10.444(2) A° , b = 11. 468(1) A° , c = 7.754(1) A° , a = 90.06(1)°, B = 82.20(1)°, Y = 90.07(1)°, Dobs = 1.87, Dca1c = 1.93, V = 920.05 13, R = 4.66%. For the cadmium compound, 000 a = 10.374(1) A, b = 11.419(2) A, c = 7.729(1) A, a = 89.95(1)°, B = 81.86(2)°, Y = 89.99(1)°, Dobs = 1.61, Dcalc = 1.64, V = 906.4613, R = 3.95%. The mercury and cadmium ions exhibit hexagonal bipyramidal coordination, with the metal ion located on a centre of symmetry in the plane of the oxygen atoms. The main differences between the two structures are an increase in the metal-oxygen distance and a reduction in the metalchloride distance when the central ion changes from Cd2+ to Hg2+. These differences may be explained in terms of the differences in hardness or softness of the metal ions and the donor atoms.
Resumo:
Les agents anti-infectieux sont utilisés pour traiter ou prévenir les infections chez les humains, les animaux, les insectes et les plantes. L’apparition de traces de ces substances dans les eaux usées, les eaux naturelles et même l’eau potable dans plusieurs pays du monde soulève l’inquiétude de la communauté scientifique surtout à cause de leur activité biologique. Le but de ces travaux de recherche a été d’étudier la présence d’anti-infectieux dans les eaux environnementales contaminées (c.-à-d. eaux usées, eaux naturelles et eau potable) ainsi que de développer de nouvelles méthodes analytiques capables de quantifier et confirmer leur présence dans ces matrices. Une méta-analyse sur l’occurrence des anti-infectieux dans les eaux environnementales contaminées a démontré qu’au moins 68 composés et 10 de leurs produits de transformation ont été quantifiés à ce jour. Les concentrations environnementales varient entre 0.1 ng/L et 1 mg/L, selon le composé, la matrice et la source de contamination. D’après cette étude, les effets nuisibles des anti-infectieux sur le biote aquatique sont possibles et ces substances peuvent aussi avoir un effet indirect sur la santé humaine à cause de sa possible contribution à la dissémination de la résistance aux anti-infecteiux chez les bactéries. Les premiers tests préliminaires de développement d’une méthode de détermination des anti-infectieux dans les eaux usées ont montré les difficultés à surmonter lors de l’extraction sur phase solide (SPE) ainsi que l’importance de la sélectivité du détecteur. On a décrit une nouvelle méthode de quantification des anti-infectieux utilisant la SPE en tandem dans le mode manuel et la chromatographie liquide couplée à la spectrométrie de masse en tandem (LC-MS/MS). Les six anti-infectieux ciblés (sulfaméthoxazole, triméthoprime, ciprofloxacin, levofloxacin, clarithromycin et azithromycin) ont été quantifiés à des concentrations entre 39 et 276 ng/L dans les échantillons d’affluent et d’effluent provenant d’une station d’épuration appliquant un traitement primaire et physico- chimique. Les concentrations retrouvées dans les effluents indiquent que la masse moyenne totale de ces substances, déversées hebdomadairement dans le fleuve St. Laurent, était de ~ 2 kg. En vue de réduire le temps total d’analyse et simplifier les manipulations, on a travaillé sur une nouvelle méthode de SPE couplée-LC-MS/MS. Cette méthode a utilisé une technique de permutation de colonnes pour préconcentrer 1.00 mL d’échantillon dans une colonne de SPE couplée. La performance analytique de la méthode a permis la quantification des six anti-infectieux dans les eaux usées municipales et les limites de détection étaient du même ordre de grandeur (13-60 ng/L) que les méthodes basées sur la SPE manuelle. Ensuite, l’application des colonnes de SPE couplée de chromatographie à débit turbulent pour la préconcentration de six anti-infectieux dans les eaux usées a été explorée pour diminuer les effets de matrice. Les résultats obtenus ont indiqué que ces colonnes sont une solution de réchange intéressante aux colonnes de SPE couplée traditionnelles. Finalement, en vue de permettre l’analyse des anti-infectieux dans les eaux de surface et l’eau potable, une méthode SPE couplée-LC-MS/MS utilisant des injections de grand volume (10 mL) a été développée. Le volume de fuite de plusieurs colonnes de SPE couplée a été estimé et la colonne ayant la meilleure rétention a été choisie. Les limites de détection et de confirmation de la méthode ont été entre 1 à 6 ng/L. L’analyse des échantillons réels a démontré que la concentration des trois anti-infectieux ciblés (sulfaméthoxazole, triméthoprime et clarithromycine) était au dessous de la limite de détection de la méthode. La mesure des masses exactes par spectrométrie de masse à temps d’envol et les spectres des ions produits utilisant une pente d’énergie de collision inverse dans un spectromètre de masse à triple quadripôle ont été explorés comme des méthodes de confirmation possibles.