855 resultados para fornos container e retangular


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bookseller's advertisement, [2] pages at end.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Includes "Lettre critique de Mr. de la Mettrie sur L'histoire naturelle de l'ame. A madame la marquise du Chatelet," 12 pages at the end.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-05

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sticky ovitraps (patent pending) were used to sample female Aedes aegypti (L.) weekly in a focus of dengue activity in Cairns, Queensland, Australia. In February 2003, transmission of dengue virus serotype 2 began in the suburb of Parramatta Park, peaking in mid-March 2003. This suburb features many older, unscreened houses with high populations of Ae. aegypti. Highest densities (2-3.5 females per trap per week) were obtained during peak dengue transmission (January and February) before mosquito control was initiated. Beginning in late March, female Ae. aegypti collected in sticky ovitraps were tested for dengue viral RNA by using a TaqMan reverse transcription-polymerase chain reaction assay. Dengue viral RNA was detected in six pools of Ae. aegypti collected in late March. The highest minimum infection rate was 116/1000 mosquitoes. After the initiation of larval control (containers treated with S-methoprene or lambda-cyhalothrin) and adult control (interior harborage sites sprayed with lambda-cyhalothrin) in early March, trap collections dropped to

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many coral reef fish possess ultraviolet (UV) colour patterns. The behavioural significance of these patterns is poorly understood and experiments on this issue have not been reported for free-living reef fish in their natural environment. The damselfish Pomacentrus amboinensis has UV facial patterns, and spectroradiometric ocular media measurements show that it has the potential for UV vision. To test the potential behavioural significance of the UV patterns, I studied the response of males, in natural territories on the reef and in aquaria, to two conspecific intruders, one presented in a UV-transmitting (UV+) container and the other in a UV-absorbing (UV-) one. Territory owners attacked intruders viewed through UV+ filters significantly more often and for longer than intruders viewed through the UV- filter. In general, the results of the field experiment confirmed those of the laboratory experiment. The results support the hypothesis that P. amboinensis males are sensitive to UV light and that reflectance patterns, which appear in high contrast only in UV, modulate the level of aggressive behaviour. A recent survey showed that many predatory fish may not have UV vision and the use of UV colours in select species of reef fish may therefore serve as a 'private communication channel'. (C) 2004 The Association for the Study of Animal Behaviour. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An experimental study of a planar microwave imaging system with step-frequency synthesized pulse for possible use in medical applications is described. Simple phantoms, consisting of a cylindrical plastic container with air or oil imitating fatty tissues and small highly reflective objects emulating tumors, are scanned with a probe antenna over a planar surface in the X-band. Different calibration schemes are considered for successful detection of these objects. (c) 2006 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carbons with slitlike pores can serve as effective host materials for storage of hythane fuel, a bridge between the petrol combustion and hydrogen fuel cells. We have used grand canonical Monte Carlo simulation for the modeling of the hydrogen and methane mixture storage at 293 K and pressure of methane and hydrogen mixture up to 2 MPa. We have found that these pores serve as efficient vessels for the storage of hythane fuel near ambient temperatures and low pressures. We find that, for carbons having optimized slitlike pores of size H congruent to 7 angstrom ( pore width that can accommodate one adsorbed methane layer), and bulk hydrogen mole fraction >= 0.9, the volumetric stored energy exceeds the 2010 target of 5.4 MJ dm(-3) established by the U. S. FreedomCAR Partnership. At the same condition, the content of hydrogen in slitlike carbon pores is congruent to 7% by energy. Thus, we have obtained the composition corresponding to hythane fuel in carbon nanospaces with greatly enhanced volumetric energy in comparison to the traditional compression method. We proposed the simple system with added extra container filled with pure free/adsorbed methane for adjusting the composition of the desorbed mixture as needed during delivery. Our simulation results indicate that light slit pore carbon nanomaterials with optimized parameters are suitable filling vessels for storage of hythane fuel. The proposed simple system consisting of main vessel with physisorbed hythane fuel, and an extra container filled with pure free/adsorbed methane will be particularly suitable for combustion of hythane fuel in buses and passenger cars near ambient temperatures and low pressures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigate the gas-particle dynamics of a device designed for biological pre-clinical experiments. The device uses transonic/supersonic gas flow to accelerate microparticles such that they penetrate the outer skin layers. By using a shock tube coupled to a correctly expanded nozzle, a quasi-one-dimensional, quasi-steady flow (QSF) is produced to uniformly accelerate the microparticles. The system utilises a microparticle cassette (a diaphragm sealed container) that incorporates a jet mixing mechanism to stir the particles prior to diaphragm rupture. Pressure measurements reveal that a QSF exit period - suitable for uniformly accelerating microparticles - exists between 155 and 220 mus after diaphragm rupture. Immediately preceding the QSF period, a starting process secondary shock was shown to form with its (x,t) trajectory comparing well to theoretical estimates. To characterise the microparticle, flow particle image velocimetry experiments were conducted at the nozzle exit, using particle payloads with varying diameter (2.7-48 mu m), density (600-16,800 kg/m(3)) and mass (0.25-10 mg). The resultant microparticle velocities were temporally uniform. The experiments also show that the starting process does not significantly influence the microparticle nozzle exit velocities. The velocity distribution across the nozzle exit was also uniform for the majority of microparticle types tested. For payload masses typically used in pre-clinical drug and vaccine applications (

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A finite difference time domain (FDTD) method is applied to investigate capabilities of an ultra-wide band (UWB) radar system to detect a breast tumor. The first part of the investigations concerns FDTD simulations of a phantom formed by a plastic container with liquid and a small reflecting target. The second part focuses on a three-dimensional numerical breast model with a small tumor. FDTD simulations are carried out assuming a planar incident wave. Various time snap shots of the electromagnetic field are recorded to learn about the physical phenomenon of reflection and scattering in different layers of the phantom.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente estudo visou comparar in vitro o atrito produzido por braquetes convencionais metálicos e estéticos com canaleta metálica e vítrea quando inseridos fios de secções redonda e retangular de diferentes dimensões, simulando situações sem deslocamento, com deslocamento de 2 mm e com simulação do efeito binding 3º. Foram utilizados 125 braquetes de 5 marcas comerciais (Roth Standard, Composite, Elation, Invu e Radiance), sendo 25 braquetes para cada corpo de prova. Para os ensaios laboratoriais, foram colados 5 braquetes simulando uma hemi-arcada superior direita (incisivos central e lateral, canino, primeiro e segundo premolares) em um dispositivo para posicionamento dos braquetes, sendo este acoplado à máquina universal de ensaios EMIC DL2000. Foram empregados os fios 0,016 , 0,018 e 0,017 x 0,025 NiTi para realização dos ensaios sem deslocamento e com deslocamento de 2 mm e os fios de secção 0,017 x 0,025 , 0,019 x 0,025 e 0,021 x 0,025 CrNi para realização dos ensaios com angulação zero grau e 3º. Para a comparação entre os braquetes nos diferentes fios e angulações, foi utilizada a Análise de Variância e o teste de Tukey (p<0,05). Os resultados demonstraram que nos ensaios sem deslocamento o braquete estético de policarbonato Composite apresentou menor atrito em todos os fios avaliados, enquanto o maior atrito em todas as combinações realizadas foi observado no braquete estético cerâmico monocristalino Radiance em relação aos demais braquetes. Nos ensaios com deslocamento de 2 mm e simulação do efeito binding 3º, os resultados foram semelhantes aos observados nos ensaios sem deslocamento. Contudo, houve uma diferença estatisticamente significante entre os cinco corpos de prova, sendo o atrito verificado, respectivamente e de forma crescente, nos braquetes Composite, Roth Standard, Elation, Invu e Radiance. Pôde-se concluir que a resistência friccional teve influência da composição dos braquetes, diâmetro dos fios e tipo de ensaio realizado (deslocamento de 2 mm e angulação de 3º). Além disso, a inserção da canaleta metálica no braquete estético de policarbonato Elation reduziu de forma estatisticamente significante o atrito, porém esse foi maior do que o gerado por um braquete convencional metálico e, por fim, a incorporação da canaleta vítrea no braquete estético cerâmico policristalino Invu ofereceu uma maior lisura de superfície, reduzindo as irregularidades e imperfeições presentes na canaleta o que levou, consequentemente, a uma redução estatisticamente significante no atrito, o que demonstra que a modificação em sua canaleta favoreceu o deslocamento e reduziu de forma efetiva essa resistência à fricção.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo do presente estudo consistiu em comparar in vitro o atrito produzido por braquetes estéticos, convencionais e autoligados quando inseridos fios retangulares de aço inoxidável de diferentes dimensões, nas angulações de zero e três graus entre os braquetes. Foram utilizados 120 braquetes de 6 marcas comerciais (Gemini, Clarity convencional, Transcend, Inspire, Clarity autoligado, Damon autoligado), sendo 20 braquetes de cada marca comercial. Para os ensaios laboratoriais, foram colados dois pares de braquetes de cada marca comercial em uma placa metálica, com uma angulação de zero e três graus entre os braquetes. Foram empregados os fios retangulares de aço inoxidável 0,017 x 0,025 , 0,019 x 0,025 e 0,021 x0,025 em uma máquina de ensaios universal Instron . Para a comparação entre os braquetes nos diferentes fios e angulações, foi utilizada a análise de variância e o teste de Tukey (p<0,05). Os resultados demonstraram que na angulação de zero grau, os braquetes autoligados apresentaram menor atrito em relação aos convencionais em todos os fios avaliados, sendo que, o braquete Clarity autoligado apresentou menor atrito estatisticamente significante que o Damon, exceto no fio 0,021 x 0,025 , em que ambos os braquetes autoligados apresentaram atrito estatisticamente semelhante. O braquete Inspire demonstrou o maior atrito em relação aos demais braquetes nos fios 0,019 x0,025 e 0,021 x0,025 . Na angulação de três graus, observou-se resultados semelhantes aos braquetes posicionados sem angulação comparando os braquetes autoligados em relação aos convencionais. Contudo, verificou-se que o atrito entre os braquetes convencionais ocorreu em ordem crescente sendo braquetes Gemini, Clarity convencional, Transcend e Inspire. Pôde-se concluir que a angulação entre os braquetes aumenta consideravelmente o atrito. Além disso, em ambas as angulações, os braquetes autoligados demonstraram menor atrito em relação aos convencionais, sendo que o braquete Clarity autoligado promoveu menor atrito que o Damon estético, exceto no fio 0,021 x 0,025 .(AU)