800 resultados para film crews


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the feasibility of taking intra-ocular pressure (IOP) readings with Goldmann-type applanation tonometer probe covered with cling film to avoid transmission of Creutzfeldt-Jakob disease (CJD). Methods: Data were collected on two occasions from the right eyes of 30 healthy subjects using a Perkins applanation tonometer. On each occasion, a single tonometry measurement was made with and without cling film covering. Results: Cling film covering brought about a statistically significant IOP bias (-0.8 mmHg on first occasion and -1.17 mmHg on second occasion). The 95% limits of agreement, between readings made with and without cling film covering, were ±3.4 mmHg on first occasion; ±2.5 mmHg on second occasion. A statistically significant reduction of inter-sessional repeatability was observed for readings taken with cling film (±5.2 mmHg) compared to those made without (±3.9 mmHg). Conclusions: Even if the above findings are found to be acceptable, given the known intra-subject variations of this type of tonometry (±4 mmHg), ethical and legal considerations relating to the barrier properties of cling film are likely to prevent its routine use by optometrists. © 2004 The College of Optometrists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the validity of covering a corneal contact transducer probe with cling film as protection against the transmission of Creutzfeldt-Jakob disease (CJD). Methods: The anterior chamber depth, lens thickness and vitreous chamber depth of the right eyes of 10 subjects was recorded, under cycloplegia, with and without cling film covering over the transducer probe of a Storz Omega Compu-scan Biometric Ruler. Measurements were repeated on two occasions. Results: Cling film covering did not influence bias or repeatability. Although the 95% limits of agreement between measurements made with and without cling film covering tended to exceed the intrasessional repeatability, they did not exceed the intersessional repeatability of measurements taken without cling film. Conclusions: The results support the use of cling film as a disposable covering for corneal contact A-scan ultrasonography to avoid the risk of spreading CJD from one subject to another. © 2003 The College of Optometrists.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article examines the multi-layered interrelation between Gerhard Roth’s writing and film. It charts the corresponding relationship of his early books to their accompanying television documentaries. The main focus of this essay however is on the film adaptation of Stille Ozean (1980) and Landäufiger Tod (1984), the two major novels in his cycle Archive des Shweigens. Supplemented by a look at the two radically different adaptations of his volume of topographical essays on Vienna called Eine Reise in das Innere von Wien (1991), the article also provides a summary overview of the seven dramas written by Roth for Austrian television in the 1990s, some of which were directed by his son Thomas. Finally Roth's approach to the medium of film is being discussed by drawing on the 59 reviews he published between 1995 and 1997 as a film critic for the Austrian magazine NEWS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mechanical, physical and chemical changes in the surface of commercial thin film metal evaporated magnetic recording media have been correlated to recording error and signal degradation measurements. Modified and adapted commercial Hi-8 video recorders have been used for sample generation whilst analytical techniques such as SXPS,IMS and SEM have been employed in the surface characterisation. The durability of the media was assessed through stop motion (still frame) and cycling tests, where error growth and signal degradation were measured as a function of running time. The tests were performed under ambient (22°C, 40% RH) and high humidity (22°C, 80% RH) conditions. Characterisation of the lubricant layer on each tape was performed through models based on XPS and angle resolved XPS. The lubricant thickness can significantly affect the durability and signal output level of a thin film tape and thus it is important that reliable quantification can be achieved. Various models were considered for determining the lubricant thickness although ultimately, the most suitable technique was deemed to be a model that assumed a uniform layer structure. In addition to thin film metal evaporated media, equivalent durability tests and surface analysis experiments were performed using a commercial metal particle tape in order that comparisons could be made between the two types of recording media. The signal performance of the thin film metal evaporated media was found to be quite different from that for the metal particle tape since dropout errors and signal degradation increased at a much earlier stage. Extensive surface analyses enabled the mechanisms responsible for media failure and error growth to be identified in the ME and MP tapes and these were found to result from cyclic stressing and fatigue on the immediate substrate of the media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing demand for high capacity data storage requires decreasing the head-to-tape gap and reducing the track width. A problem very often encountered is the development of adhesive debris on the heads at low humidity and high temperatures that can lead to an increase of space between the head and media, and thus a decrease in the playback signal. The influence of stains on the playback signal of reading heads is studied using RAW (Read After Write) tests and their influence on the wear of the heads by using indentation technique. The playback signal has been found to vary and the errors to increase as stains form a patchy pattern and grow in size to form a continuous layer. The indentation technique shows that stains reduce the wear rate of the heads. In addition, the wear tends to be more pronounced at the leading edge of the head compared to the trailing one. Chemical analysis of the stains using ferrite samples in conjunction with MP (metal particulate) tapes shows that stains contain iron particles and polymeric binder transferred from the MP tape. The chemical anchors in the binder used to grip the iron particles now react with the ferrite surface to create strong chemical bonds. At high humidity, a thin layer of iron oxyhydroxide forms on the surface of the ferrite. This soft material increases the wear rate and so reduces the amount of stain present on the heads. The stability of the binder under high humidity and under high temperature as well as the chemical reactions that might occur on the ferrite poles of the heads influences the dynamic behaviour of stains. A model of stain formation taking into account the channels of binder degradation and evolution upon different environmental conditions is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Surfactant proteins A, B, C and D complex with (phospho)lipids to produce surfactants which provide low interfacial tensions. It is likely that similar complexation occurs in the tear film and contributes to its low surface tension. Synthetic protein-phospholipid complexes, with styrene maleic anhydrides (SMAs) as the protein analogue, have been shown to have similarly low surface tensions. This study investigates the potential of modified SMAs and/or SMA-phospholipid complexes, which form under physiological conditions, to supplement natural tear film surfactants. Method: SMAs were modified to provide structural variants which can form complexes under varying conditions. Infrared spectroscopy and Nuclear Magnetic Resonance were used to confirm SMA structure. Interfacial behaviour of the SMA and SMA-phospholipid complexes was studied using Langmuir trough, du Nûoy ring and pulsating bubblemethods. Factors which affect SMA-phospholipid complex formation, such as temperature and pH, were also investigated. Results: Structural manipulation of SMAs allows control over complex formation, including under physiological conditions (e.g. partial SMAesterfication allowed complexation with dimyristoylphosphatidylcholine, at pH7). The low surface tensions of the SMAs (42mN/m for static (du Nûoy ring) and 34mN/m for dynamic (Langmuir) techniques) demonstrate their surface activity at the air-aqueous interface. SMA-phospholipid complexes provide even lower surface tensions (~2 mN/m), approaching that of lung surfactant, as measured by the pulsating bubblemethod. Conclusions: Design of the molecular architecture of SMAs allows control over their surfactant properties. These SMAs could be used as novel tear films supplements, either alone to complex with native tear film phospholipids or delivered as synthetic protein-phospholipid complexes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: With the potential to address evaporative dry eye, a novel spray has been developed in which phospholipid liposomes are delivered to the tear film via the surface of the closed eyelid. This study evaluated the short-term effects of liposomal spray application on the lipid and stability characteristics of the pre-ocular tear film in normal eyes. Methods: Twenty-two subjects (12M, 10F) aged 35.1 ± 7.1 years participated in this prospective, randomised, double-masked investigation in which the liposomal spray was applied to one eye, and an equal volume of saline spray (control) applied to the contralateral eye. Lipid layer grade (LLG), non-invasive tear film stability (NIBUT) and tear meniscus height (TMH) were evaluated at baseline, and at 30, 60, 90 and 135 minutes post-application. Subjective reports of comfort were also compared. Results: Treated and control eyes were not significantly different at baseline (p>0.05). Post-application, LLG increased significantly, at 30 and 60 minutes, only in the treated eyes (p=0.005). NIBUT also increased significantly in the treated eyes only (p<0.001), at 30, 60 and 90 minutes. TMH did not alter significantly (p>0.05). Comfort improved relative to baseline in 46% of treated and 18% of control eyes, respectively, at 30 minutes post-application. Of those expressing a preference in comfort between the eyes, 68% preferred the liposomal spray. Conclusions: Consistent with subjective reports of improved comfort, statistically and clinically significant improvements in lipid layer thickness and tear film stability are observed in normal eyes for at least an hour after a single application of a phospholipid liposomal spray.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contact lenses have become a popular method of vision correction for millions of people globally. As with all devices designed for use within the body, interactions occur between the implanted material and the surrounding biological fluid. A common complaint of lens wearers is that they often experience symptoms of dry eye whilst wearing lenses. This sensation is often heightened towards the end of the day. Through the course of this study, various analytical techniques have been utilised including one dimensional electrophoresis and Western Blotting to study the protein profiles of tear samples. By studying the tears of non-contact lens wearers, it was possible to analyse what could be considered normal, healthy, individuals. A clinical study was also undertaken which followed a population of individuals from the neophyte stage to one whereby they were accustomed lens wearers. Tears were monitored at regular intervals throughout the course of this study and worn contact lenses were also analysed for proteins that had been deposited both on and within the lens. Contact lenses disrupt the tear film in a physical manner by their very presence. They are also thought to cause the normal protein profile to deviate from what would be considered normal. The tear film deposits proteins and lipids onto and within the lens. The lens may therefore be depriving the tear film of certain necessary components. The ultimate aim of this thesis was to discover how, and to what extent, lenses affected tear proteins and if there were any proteins in the tear fluid that had the potential to be used as biochemical markers. Should this be achievable it may be possible to identify those individuals who were more likely to become intolerant lens wearers. This study followed the changes taking place to the tear film as an effect of wearing contact lenses. Twenty-eight patients wore two different types of silicone hydrogel lenses in both a daily wear and a continuous wear regime. The tear protein profiles of the lens-wearers were compared with a control group of non-lens wearing individuals. The considerable amount of data that was generated enabled the clearly observable changes to the four main tear proteins to be monitored.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis attempts to re-examine the work of Jean-Luc Godard and in particular the claims which have been made for it as the starting-point for a revolutionary cinema.This re-examination involves, firstly, a critical summary of the development of Structuralist thinking, from its origins in linguistics, with Saussure, through to its influence on Marxism, with Althusser. It is this `Structural Marxism' which prepared the ground for a view of Godard as a revolutionary film-maker so its influences on film theory in the decade after 1968 is traced in journals such as Cahiers du Cinéma and Screen and in the work of their editors and contributors. Godard's relationship with such theories was a complex one and some of the cross-breeding is revealed in a brief account of his own ideas about his film-making. More important, however is his practice as a committed `political' film-maker between 1968 and 1972 which is analysed in terms of the responses it makes to the cultural opportunities offered in the period after the revolutionary situation of May 1968. The severe problems revealed by that analysis may be partially resolved in Godard's greatest `political' achievement Tout va bien, but a comparative analysis proves that in earlier `a-political' films such as Vivre sa vie, he was creating more meaningful and perhaps even more revolutionary art, whose formal experimentation is more organically linked to its subject and whose ability to communicate ideas far oustrips the later work. In conclusion some indications are suggested of a more fruitful basis for Marxist theories of art than Structural variants, seeking a non-formalist approach in the work of Marx, of Trotsky, of Brecht and Lukacs.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The available literature has been surveyed to determine the parameters affecting fuelling requirements of spark ignition engines and their relation to engine performance and emissions. Theories and experiment relating to two phase and multi-component flows have also been examined and the techniques employed in the measurement of droplet sizes and liquid wall films have been reviewed. Following preliminary steady flow visualisation experiments to examine the trajectories of droplets discharging from the valve port an extensive practical investigation of the spectrum of droplet sizes formed by the break up of the wall film has produced results which have been correlated in terms of the important fuel and airflow parameters. It is concluded that the Sauter mean diameter of droplets formed by the break up of the wall film will vary between 70 and 150 m, depending on the operating conditions of the engine. The spectra of droplet sizes measured show that a significant proportion of the total mass of the wall film breaks into drops which will be too large to burn completely and, by comparison with measurements of unburned hydrocarbon emissions from engines supplied with a homogeneous mixture of air and gaseous hydrocarbons, it is concluded that the droplets from the wall film are likely to increase emissions by 50%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. Standard pharmaceutical capsules are designed to dissolve in the acidic environment of the stomach releasing the encapsulated contents for absorption. When release is required further along the gastrointestinal tract capsules can be coated with acid insoluble polymers to enable passage through the stomach and dissolution in the intestine. This paper describes formulations that have the potential to be used to produce two-piece hard capsules for post-gastric delivery without the requirement of an exterior coat. Methods. The formulation uses three polysaccharides: sodium alginate, hypromellose and gellan gum to provide acid insolubility and the ability to form capsules using standard industrial equipment. Key findings. The rheological profile, on cooling, of the base material, water content and thickness of the films were shown to be comparable with those of commercial capsules. The capsules remained intact for 2 h in 100 mm HCl at pH 1.2, and within 5 min of being removed from the acid and submerged in phosphate-buffered saline at pH 6.8 were ruptured. Conclusions. Selected formulations from this study have potential for use as delayed release capsules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The possible evaporation of lubricant in fluid film bearings has been investigated theoretically and by experiment using a radial flow hydrostatic bearing supplied with liquid refrigerant R114. Good correlation between measured and theoretical values was obtained using a bespoke computational fluid dynamic model in which the flow was assumed to be laminar and adiabatic. The effects of viscous dissipation and vapour generation within the fluid film are fully accounted for by applying a fourth order Runge-Kutta routine to satisfy the radial and filmwise transverse constraints of momentum, energy and mass conservation. The results indicate that the radial velocity profile remains parabolic while the flow remains in the liquid phase and that the radial rate of enthalpy generation is then constant across the film at a given radius. The results also show that evaporation will commence at a radial location determined by geometry and flow conditions and in fluid layers adjacent to the solid boundaries. Evaporation is shown to progress in the radial direction and the load carrying capacity of such a bearing is reduced significantly. Expressions for the viscosity of the liquid/vapour mixture found in the literature survey have not been tested against experimental data. A new formulation is proposed in which the suitable choice of a characteristic constant yields close representation to any of these expressions. Operating constraints imposed by the design of the experimental apparatus limited the extent of the surface over which evaporation could be obtained, and prevented clear identification of the most suitable relationship for the viscosity of the liquid/vapour mixture. The theoretical model was extended to examine the development of two phase flow in a rotating shaft face seal of uniform thickness. Previous theoretical analyses have been based on the assumption that the radial velocity profile of the flow is always parabolic, and that the tangential component of velocity varies linearly from the value at the rotating surface, to zero at the stationary surface. The computational fluid dynamic analysis shows that viscous shear and dissipation in the fluid adjacent to the rotating surface leads to developing evaporation with a consequent reduction in tangential shear forces. The tangential velocity profile is predicted to decay rapidly through the film, exhibiting a profile entirely different to that assumed by previous investigators. Progressive evaporation takes place close to the moving wall and does not occur completely at a single radial location, as has been claimed in earlier work.